Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | ₹24.0 L Quoted ₹25.0 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹27.0 L+₹2.0 L (7.88%)Rejected-AOC | ₹27.0 L+₹2.0 L (7.88%) | L2 | Rejected-AOC Other than lowest |
| 3 | L3₹27.2 L+₹2.2 L (8.77%)Rejected-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | ₹27.2 L+₹2.2 L (8.77%) | L3 | Rejected-AOC Other than lowest |
| 4 | L4₹32.6 L+₹7.6 L (30.3%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹32.6 L+₹7.6 L (30.3%) | L4 | Rejected-AOC Other than lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
7 Oct 2022, 6:00 pmClosed
Lt Col Vikram Singh
GE (U) Chandimandir
GE(U)/CHM-22/2022-23 REPAIRS AND MAINTENANCE OF STREET LIGHT CABLES POLES EARTHING AND OTHER ALLIED WORKS AT VARIOUS OTM ACCN UNDER GE (U) CHANDIMANDIR
2022_MES_551058_1
GE(U)/CHM-22/2022-23
Open Tender
Miscellaneous Works
Item Rate
335 days
GE (U) Chandimandir
Please refer as per tender documents
7 documents required · 7 mandatory
₹500
GE (U) Chandimandir
₹80,000
23 Nov 2022
9 Sept 2022
10 Oct 2022
9 Sept 2022
7 Oct 2022
23 Sept 2022
Amount
Excavation in trenches for foundations, laying / taking out of cables, erecting of poles etc, in any type of soil, not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr in width and getting out, complete all as specified and as directed.
All as per the description of Srl item No 1 herein above but depth exceeding 1.50 metre but not exceeding 3.00 metre
Returning, filling in soils, in trenches, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed
Removing excavated soils to a distance exceeding 50 metres and not exceeding 100 metres and depositing where directed at a level not exceeding 1.50 metre above the starting point.
Cement concrete (1:4:8) type D-2, (using 40mm graded crushed stone aggregates) as in foundations and mass concrete etc complete all as specified and as directed.
Cement concrete (1:3:6) type C-2, (using 40mm graded crushed stone aggregates), in foundation and mass concrete etc complete all as specified and as directed.
Cement concrete (1:2:4) type B-1, (using 20mm graded crushed stone aggregates) as in coping, blocks, bed plates, kerbs etc including weathering, slightly rounded or chamfered angles and throating as directed including as necessary formwork as required complete all as specified and directed.
Supply, erection and fixing in position 9.00 metre long, steel tubular swaged poles complete with mild steel base plate, flat top welded type 410, SP-31 IS:2713 marked, drilling of necessary holes including bolts, nuts and washers as required and painting with two coats of aluminium paint over a coat of red oxide primer on exposed, surfaces of poles and two coats of black bituminous paint throughout internally and externally upto the planting depth including providing reflective strips of width 10cm upto a height of 1.20m from ground level in alternate colour yellow and black around the pole of pattern as approved by GE and marking pole number at appropriate height with shade and colour as approved by Engineer-in-Charge complete all as specified and as directed. Note : Excavation earthwork and concrete work shall be measured and paid for separately.
Supplying, laying, jointing and testing LT underground electric cable XLPE insulated, PVC sheathed, armoured heavy duty 1100 volts grade cross section area 35 Sqmm 3.50 Core aluminium conductor laid in trenches/ducts or passing through pipes under road or fixed to poles complete all as specified and as directed, with and including taking up or down old damaged electric cable and removing from site of work, complete all as directed.
Supplying, laying, jointing and testing LT underground electric cable XLPE insulated, PVC sheathed, armoured heavy duty 1100 volts grade cross section area 25 Sqmm 4 Core aluminium conductor laid in trenches/ducts or passing through pipes under road or fixed to poles complete all as specified and as directed, with and including taking up or down old damaged electric cable and removing from site of work, complete all as directed.
Supplying, laying, jointing and testing LT underground electric cable XLPE insulated, PVC sheathed, armoured heavy duty 1100 volts grade cross section area 16 Sqmm 4 Core aluminium conductor laid in trenches/ducts or passing through pipes under road or fixed to poles complete all as specified and as directed, with and including taking up or down old damaged electric cable and removing from site of work, complete all as directed.
Supplying, laying, jointing and testing LT underground electric cable XLPE insulated, PVC sheathed, armoured heavy duty 1100 volts grade cross section area 10 Sqmm 4 Core aluminium conductor laid in trenches/ducts or passing through pipes under road or fixed to poles complete all as specified and as directed, with and including taking up or down old damaged electric cable and removing from site of work, complete all as directed.
50mm bore GI tubing medium grade, laid in trenches / fixed to walls / under roads etc as protection to cable, with all fittings and fixtures like mild steel flat iron clamps, nuts, bolts and washer of appropriate size and shape as approved by Engineer-in-Charge complete all as specified and as directed, with and including taking up / down old damage steel pipe and removing from site of wrok complete all as specified and as directed.
50mm bore GI tubing, medium grade fixed / erected as post for PTL fitting, fixed appropriately on ground with cement concrete or clamps, nuts, bolts as approved/directed by Engineer-in-Charge complete all as specified and as directed with and including taking down old damaged steel pipe and removing from site of work complete all as specified and as directed.
Supply and lay Double wall corrugated HDPE duct pipe of 50mm outer dia conforming to IS:14930 Pt-II with antirodant and non flame propergating properties of make and colour as approved by Engineer-in-Charge with fittings as protection to cable, laid in tranches or fixed to poles/walls complete with and including taking up/ down old damaged pipe and removing from site of work complete all as specified and as directed.
Painting of existing steel tubular poles 9.00 metre long with one coat of Aluminium paint on pole and cross arm, clamps, brackets fitted/fixed on pole, above to 1.20 metre height of pole including preparing the steel surfaces to the entire satisfaction of Engineer-in-Charge and providing reflective strips of width 10cm at a height of 1.20 metre from ground level in alternate colour green and white around the pole of pattern alongwith pole number marking with black paint as approved by GE and marking pole number at appropriate height with shade and colour as approved by Engieer-in-Charge complete all as specified and as directed.
Cutting of tree branches ( girth not more than 10 cm) falling over the street lights for all around clearance of the fittings carefully to avoid any damage to the light fittings and disposing of the cut tree branches to a distance not more than 100 mtrs complete all as specified and as directed.
Providing recharge for GPRS SIM as specified for street light automation panels including subscription for cloud data usage for 12 months complete all as specified and directed.
M&L for entire opertion required for aligning the 9.00 m steel tubular pole vertical and erect in position by way of disconnecting overhead conductors if any, taking out pole from foundation, dismantling the foundation concrete, filling the foundation with cement concrete 1:3:6 type C-1 and coping after erecting the pole with cement concrete 1:2:4 type B1 around the pole above ground level, as per strandardised requirements, including excvation if any required and removal of rubbish to outside the MoD land complete all as specified and as directed by the Engr-in-Charge.
Disconnecting and taking out serviceable pole of octogonal including foundation all connections and shifting the pole to new location upto 50mtrs, errection of pole including PCC Work with cement concrete 1:3:6 type C-1 and coping after erecting the pole with cement concrete 1:2:4 type B1 around the pole earthwork, cable connections and necessary nut/bolts/ washers etc, complete all as specified and as directed by Engr-in-Charge.
M&L earthing complete with galvanized steel plate electrode 60cm X60cm X6mm surrounded by charcoal & salt buried directly in a pit of depth not less than 1.5m below ground level with top edge of the earth plate at a depth of not less than 1.50m below ground level, connected to and including GI strip 32x6mm upto 7.5m length by means of bolts, nuts, check nuts & washers of galvanized iron, earth strip protected by galvanized steel pipe 40 mm bore (light grade) & connected to main control board including necessary excavation & earth work, disposal of surplus soil not exceeding 50m, in any type of soil. (The rate also includes for cost of charcoal & salt in alternate layers of 15 cm thickness, 20 mm bore GI pipe (medium grade) for watering, funnel, wiremesh, PCC chamber in cement concrete (1:3:6) type C-1, 40mm thick RCC(1:2:4) type B-1 cover & frame etc) including GI protecton pipe for earth lead complete all as indicated in electric plate No 3 of SSR 2009 Part I including testing complete all as specified and as directed.
Supply only PVC insulated sheathed 1100volts grade twin core 10.00 Sqmm size aluminium conductor service cable making connection and testing for functioning complete all as specified and as directed with and including taking down old damaged cable and removing from site of work complete all as directed
Supply only Multi stranded copper cable PVC insulated unearthed 1100Volts grade of size 2.50 Sqmm 3.00 Core for connection from junction box to light fitting and making connection and testing for functioning of light fitting complete all as specified and as directed with and including taking down old damaged cable and removing from site of work, complete all as of directed
Supply only LED Flood Light luminaire of capacity 120 Watt, system lumen efficacy not less than 100 lumen per watt, total system lumens not less than 12000 lumens, PF>0.90 ,CRI not less than 70, THD not more than 10 %, surge protection not less than 5 KV internal and 10 kV external, colour temp 5700 k +-300k, operating voltage ranging from 120V to 270 V at 50 Hz AC frequency,Pressure die cast aluminium housing in powder coated finish , heat resistant toughened glass , gasket etc ,protection class IP 66 complete as all as specified and directed .
Supply only LED Flood Light luminaire of capacity 150 Watt, system lumen efficacy not less than 100 lumen per watt, total system lumens not less than 15000 lumens, PF>0.90 ,CRI not less than 70, THD not more than 10 %, surge protection not less than 5 KV internal and 10 kV external, colour temp 5700 k +-300k, operating voltage ranging from 120V to 270 V at 50 Hz AC frequency,Pressure die cast aluminium housing in powder coated finish , heat resistant toughened glass , gasket etc ,protection class IP 66 complete as all as specified and directed .
Supply only LED Flood Light luminaire of capacity 200 Watt, system lumen efficacy not less than 100 lumen per watt, total system lumens not less than 20000 lumens, PF>0.90 ,CRI not less than 70, THD not more than 10 %, surge protection not less than 5 KV internal and 10 kV external, colour temp 5700 k +-300k, operating voltage ranging from 120V to 270 V at 50 Hz AC frequency,Pressure die cast aluminium housing in powder coated finish , heat resistant toughened glass , gasket etc ,protection class IP 66 complete as all as specified and directed .
Supply only LED Flood Light luminaire of capacity 70 Watt, system lumen efficacy not less than 100 lumen per watt, total system lumens not less than 7000 lumens, PF>0.90 ,CRI not less than 70, THD not more than 10 %, surge protection not less than 5 KV internal and 10 kV external, colour temp 5700 k +-300k, operating voltage ranging from 120V to 270 V at 50 Hz AC frequency,Pressure die cast aluminium housing in powder coated finish , heat resistant toughened glass , gasket etc ,protection class IP 66 complete as all as specified and directed .
Supply only LED Flood Light luminaire of capacity 50 Watt, system lumen efficacy not less than 100 lumen per watt, total system lumens not less than 5000 lumens, PF>0.90 ,CRI not less than 70, THD not more than 10 %, surge protection not less than 5 KV internal and 10 kV external, colour temp 5700 k +-300k, operating voltage ranging from 120V to 270 V at 50 Hz AC frequency,Pressure die cast aluminium housing in powder coated finish , heat resistant toughened glass , gasket etc ,protection class IP 66 complete as all as specified and directed .
Supply only RGB LED Flood Light luminaire of capacity 50 Watt lighting colour RGB lighting type with remote to change colours IP 65 protection, aluminium die cast housing, PF >0.95, LED driver, over voltage & under voltage protection, short circuit protection, with hanging & locking arrangement complete all as specified and as directed.
Supply only high power LED street light fittings energy saving luminaire with lens , capacity 60 watt with system efficacy (lm/w) not less than 100 lumens per watt, total system lumen not less than 6000 lumens, PF not less than 0.95, CRI not less than 70, colour temp. 5700K + 300K, surge protection not less than 5 KV, high pressure die cast aluminium alloy LM6 housing IP 66 class 1 protection, toughened glass cover, driver efficiency > 85% with constant output of current and voltage against input voltage variation 120 to 270 volt at 50 Hz ( + 5%), THD< 10% complete all as specifiedans as directed. The driver should be fetted with electrolytic capacitor of min 105 degrees rating and must be with phase to phase protection, external SPD should be minimum 10 KV capacity.
Supply only high power LED street light fittings energy saving luminaire with lens , capacity 90 watt with system efficacy (lm/w) not less than 100 lumens per watt, total system lumen not less than 9000 lumens, PF not less than 0.95, CRI not less than 70, colour temp. 5700K + 300K, surge protection not less than 5 KV, high pressure die cast aluminium alloy LM6 housing IP 66 class 1 protection, toughened glass cover, driver efficiency > 85% with constant output of current and voltage against input voltage variation 120 to 270 volt at 50 Hz ( + 5%), THD< 10% complete all as specifiedans as directed. The driver should be fetted with electrolytic capacitor of min 105 degrees rating and must be with phase to phase protection, external SPD should be minimum 10 KV capacity.
Supply only high power LED street light fittings energy saving luminaire with lens , capacity 120 watt with system efficacy (lm/w) not less than 100 lumens per watt, total system lumen not less than 12000 lumens, PF not less than 0.95, CRI not less than 70, colour temp. 5700K + 300K, surge protection not less than 5 KV, high pressure die cast aluminium alloy LM6 housing IP 66 class 1 protection, toughened glass cover, driver efficiency > 85% with constant output of current and voltage against input voltage variation 120 to 270 volt at 50 Hz ( + 5%), THD< 10% complete all as specifiedans as directed. The driver should be fetted with electrolytic capacitor of min 105 degrees rating and must be with phase to phase protection, external SPD should be minimum 10 KV capacity.
Supply only LED Post Top Lantern light fitting 40 watt (cool white) capacity with die cast aluminium spigot, spun aluminium powder coated top cover, Aluminium PDC heat sink , opal PC diffuser and clear acrylic IP 66 . PF >0.95, LED driver, over voltage & under voltage protection, short circuit protection, with hanging & locking arrangement complete all as specified and as directed.
Supply only LED Post Top Lantern light fitting 40 watt (warm white) capacity with die cast aluminium spigot, spun aluminium powder coated top cover, Aluminium PDC heat sink , opal PC diffuser and clear acrylic IP 66 . PF >0.95, LED driver, over voltage & under voltage protection, short circuit protection, with hanging & locking arrangement complete all as specified and as directed.
Supply only LED Post Top Lantern light fitting 20-25 watt (cool white) capacity with die cast aluminium spigot, spun aluminium powder coated top cover, Aluminium PDC heat sink , opal PC diffuser and clear acrylic IP 66 . PF >0.95, LED driver, over voltage & under voltage protection, short circuit protection, with hanging & locking arrangement complete all as specified and as directed.
Supply only LED Post Top Lantern light fitting 20-25 watt (warm white) capacity with die cast aluminium spigot, spun aluminium powder coated top cover, Aluminium PDC heat sink , opal PC diffuser and clear acrylic IP 66 . PF >0.95, LED driver, over voltage & under voltage protection, short circuit protection, with hanging & locking arrangement complete all as specified and as directed.
Supply only spot track light of 30 Watt warm white outdoor type , IP 20, high efficiency, powder coated aluminium housing with clear glass cover make it ideal for lighting up including all connections complete all as specified and as directed.
Supply only spot light of 09 Watt warm white outdoor type , IP 20, high efficiency, engineering plastic housing with mirrior reflector and clear diffuser make it ideal for lighting up including all connections complete all as specified and as directed.
Supply only LED Bollard type garden light 9 watt, warm white capacity and 600mm height, decorative and cylindrical shape LED bollard light with integrated driver, soft and comfortable uniform light distribution with opal diffusar & aluminium reflector IP 66 class protection complete with fixing bolts/nuts & all accessories / fitting, complete all as specified and directed.
Supply only dome type globe light 8 inch diameter with polycarbonate diffuser or milky white with B-22 holder and LED warm white bulb of 14 Watt, for fixing arrangement on pole / pipe complete all as specified & as directed.
NOTES for Light fittings/luminaire:- (a) Each luminaire should be printed on the luminaire fittings as "MES", CA No: GE(U)/CHM- /2022-23 (b) The contractor shall submit test report from manufacturer of the LED fittings giving detail of each parameter /specifications of led luminaire mentioned in the BOQ item to comply with minimum requirements mentioned therein. (c) The contractor shall also submit LM-79 & LM-80 test report from any valid NABL accreditation laboratory. (d) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (e) The material of any MAKE or manufacturer of the luminaire mentioned above, whose products do not comply with the required specifications and quality, will not be accepted and contractor or the manufacturer will have no claim on account of rejection of materials on this ground.
Supply only street light mounting bracket suitable for LED fitting of length 1.50 metre, made out of medium grade GI pipe of 50mm bore bent to shape (120 degree) as directed by Engineer-in-Charge complete with two No GI Clamps made to shape out of 50mm x 6mm flat iron, with GI nuts, bolts and washers of suitable size for fixing on pole wall complete all as specified and as directed, with and including taking down old damaged bracket and removing from site of work, complete all as specified and as directed.
Supply only Non metallic junction box made out of PVC sheet of size not less than 240mm x 130 mmx 110 mm hinged with lockable arrangement with and including aluminium bus bar TPN capacity 200 Amps with one No MCB 2.50 Amp SP 10 KA ‘C’ curve with provision of tapping incoming and outgoing cable connection with gland box of suitable size and fixing on pole or grouting in PCC muff complete all as specified and as directed, with and including taking out unserviceable junction box and removing from site of work complete all as specified and as directed.
Supply only switch Piano flush type single pole one way 5/6 Amp for garden lights complete all specified and as directed.
Supply only socket out let 3/5 pin, 5 Amp piano flush type for garden lights complete all specified and as directed.
Supply only socket out let 3/5 pin, 15 Amp piano flush type for garden lights complete all specified and as directed.
Supply only PVC rectangular block for mounting switches, sockets etc with 3mm thick plastic laminated sheet cover, MS screw, washers etc of size (100 x 100 x 50) mm for garden lights complete all specified and as directed.
Supply only LT UG Cable lugs(thimble) made out of aluminium 10 Sqmm complete all as specified and by directed by Enginner -in-Charge
Supply only LT UG Cable lugs(thimble) made out of aluminium 16 Sqmm complete all as specified and directed by Enginner -in-Charge
Supply only LT UG Cable lugs(thimble) made out of aluminium 25 Sqmm complete all as specified and directed by Enginner -in-Charge
Supply only LT UG Cable lugs(thimble) made out of aluminium 35 Sqmm complete all as specified and directed by Enginner -in-Charge
S&F LT UG Cable inline connected (Ferrule) made out of aluminium suitable for 10 sqmm complete as as specified and directed by Enginner -in-Charge
Supply only LT UG Cable inline connected (Ferrule) made out of aluminium suitable for 16 sqmm complete as as specified and directed by Enginner -in-Charge
Supply only LT UG Cable inline connected (Ferrule) made out of aluminium suitable for 25 sqmm complete as as specified and directed by Enginner -in-Charge
Supply only LT UG Cable inline connected (Ferrule) made out of aluminium suitable for 35 sqmm complete as as specified and directed by Enginner -in-Charge
Attending defective/ non functional street light complaints ( Street light/ flood light/post top light of any type/ any size fitted on pole/wall/post/pillars etc) and street light feeder faults (OH lines or UG Cables) such as short circuiting, snapping of conductors phase/neutral loss in UG cables by deploying one electrician and one helper daily including Sundays & Holidays from 0900 hrs to 1700hrs and repairing the same to make the lights functional and serviceable by repairing and/ or replacing the defective parts/electrical items of any type as per existing, checking of connections etc complete all as specified and as directed for : OTM accn area, all units, across Kalka units. KS Marg, Philora Marg, Water supply and electric supply installation at Chandimandir Cantt.
NOTES:_ (i) Supply and fixing/Replacement of defective parts of light fittings/defective lights fittings shall be measured and paid separately. (ii) Contractor is required to deploy one electrician having ITI certification with 05 years practical experiance and one helper having 03 years practical experience from 0900 hrs to 1700 hrs and vehicle mounted ladder including driver. Contractor himself personally or through accredited representative will attend the office of Engineer-in-Charge at 0930 hrs to receive the complaints and compliance reports on making functional lights shall be submitted to Engineer-in-Charge at 1630hrs. Failures on the part of contractor or his accredited representative to report the office of Engineer-in-Charge at above mentioned hours/timing will be liable for a penalty of Rs 2000/- per day. (iii) Contractor shall provide conveyance to the deployed workmen at his own cost.
(iv) The contractor has to keep the vehicle fitted with mounted ladder fully functional and operative for 0900hrs to 1700hrs all the days. In case of maintenance of the vehicle, other arrangements for vehicle fitted with mounted ladder shall have to be made by the contractor, in advance. Failure on the part of contractor for above compliance or replacement of vehicle in case of breakdown will be liable for penalty of Rs 3000/- per day. (v) Failure on the part of contractor to make the light functional on very same day after receipt of complaint in the office of Engineer-in-Charge is liable for penalty of Rs 500/- on per complaint per day including sundays & holidays. (vi) Failure on the part of contractor to deploy his team of electrician and helper with vehicle fitted with mounted ladder and driver during the hrs mentioned above is liable for a penalty of Rs 5000/- per day.
(vii) All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor to his workmen. Contractor will be solely responsible for full safety of the persons deployed for providing the services and department will have no liability for any type of accident/injury of any type. Unit rate quoted will be deemed to inclusive of the cost of the same and no extra payment shall be made on his part. (viii) All type of T&P, PVC insulation tapes, minor nuts/ bolts /washers etc required for maintenance of the services shall be provided by the contractor without any extra cost to department. (ix) Any loose/broken overhead conductor shall be re-stringed /repaired to make the system functional in all respects and unit rate quoted shall be deemed to be inclusive of the cost of the same.
CHADHA ENGINEERS
M/s badrinath Traders
R D Bansal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .