Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 LAccepted-AOC | L1 | Accepted-AOC Agreement done and Work Order Issued. | |
| 2 | L2₹2.1 L+₹468.50 (0.22%)Rejected-Finance | L2 | Rejected-Finance JITENDRA KUMAR RANA is Qualified | |
| 3 | L3₹2.2 L+₹10,695 (5.00%)Rejected-Finance HOSHANGABAD M P | HOSHANGABAD | MADHYA PRADESH | L3 | Rejected-Finance JITENDRA KUMAR RANA is Qualified | |
| 4 | Not Admitted-Fee/PreQual/Technical 0 BELCHAURA MAUNATH BHANJAN MAU MAU UTTAR PRADESH 275101 | MAU | UTTAR PRADESH | 275101 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹2.3 L
EMD Value
₹4,580
Closing Date
15 Jul 2021, 6:00 pmClosed
PROJECT ENGINEER MPPHIDCL BALAGHAT
OFFICE MPPHIDCL POLICE LINE BALAGHAT
External Electrification work for Shifting of 11kv(H.T.) line from the land of police department gram Awlajhari Baiher naka balaghat for construction of highay check post baiher naka Balaghat.
2021_MPPHC_149207_1
04/ 2021-22
Open Tender
Electrical Works
Item Rate
30 days
BALAGHAT
AS PER NIT
3 documents required · 3 mandatory
₹2,000
₹4,580
8 Sept 2021
3 Jul 2021
19 Jul 2021
3 Jul 2021
15 Jul 2021
3 Jul 2021
Amount
Supplying and erection of HT/LT over head line single length supports complete with aligning and keeping it in truly vertical position, including digging pit of required size in all type of soil/rocks filling with 1:3:6 cement concrete of 0.60 mtr. dia. around the pole up to ground level including muffing of 0.45 mtr. dia. from ground level to 0.45 mtr. high as per specifications with 20 cm. thick base foundation in 1:4:8 cement concrete as required refilling the pit with boulder and soil as required, including painting of pole with bitumen paint below GL and two coats of red oxide and two coats of aluminium paint or synthetic enamel paint above GL as directed complete as per specifications. The depth of burying of pole shall be 1/6th of the length of pole.
(i) H Beam 11 Mtr Long 152x152 or 150x150 mm 37.1 Kg/Mtr. Weight
STAY SET Supplying and erection of GI/MS stay set complete with stay rod, anchor plate of size 300x300x5mm, thimble, stay clamp, turn buckle, bow tightener etc. with stay wire, strain insulator, nut bolts as per specifications including excavation in all type of soil/ rocks and foundation in cement concrete 1:3:6 of required size and other necessary materials complete as required as per specifications
(i) GI Stay Rod 20mm dia (Painted) 1.8 m long with 7/4.00mm (7/8 SWG) stay wire for HT line.
(ii) GI Stay Rod 16mm dia (Painted) 1.8 m long with 7/3.15mm stay wire for LT line.
33KV/11 KV DISC POLYMER L.ROAD TYPE T& C INSULATOR Supplying and fixing polymer type 11KV/33KV HT Disc (strain) insulator of approved make on existing pole or bracket with GI hardware and other necessary materials complete as required.
(i) 11 KV (45KN) Disc Polymer L.Rod type T&C Insulator with 11 KV Composite Polymer Strain set with hard ware suitable for panther conductor w L.ROD type T&C Insulator complete
POLYMER PIN INSULATOR Supplying and fixing polymer type 11KV / 33KV pin insulator with GI pin, of approved make on existing pole or bracket with other necessary materials complete as required.
(i) 11 KV 5 KN PIN Composite Polymer Insulator
Supplying and drawing ACSR/AAAC conductor of approved make with stringing, making off complete with binding at existing insulator, jointing , jumpering, billing off connecting, making 'D' loops connections etc. complete and clearing of obstacles (if any) as specified and directed.
AAAC RACCOON Conductor 0.80 sq. inch (80sq. Mm. Al.Eq
EARTHING COIL OF 115 TURNS OF 50 MM DIA.2.5 MTR.LEAD OF 4.0 MM G.I.WIRE Providing and fixing earthing arrangement for HT/LT poles with 8SWG GI lead of 115 turns of 50 mm dia. connection with pole / cross arm / control junction box on pole with 4 mm dia. GI lead through 20 mm dia A class GI protection pipe of 2.5 m length duly bend, packing of charcoal powder and salt as per specifications including excavation of pit in all type of soil / rock, refilling of pit by black cotton soil etc. complete.
ANTI CLIMBING DEVICE BARBED WIRE Supplying and fixing 2 ply 12 gauge barbed wire around the existing HT/LT electric pole for safety measures as per IE rules including all stapples and all other necessary materials complete as required as per specifications.
DANGER BOARD ENAMELED Providing and fixing enamelled danger caution plate/board on existing electric poles or wherever required of size 250x200 mm, made of 1.6mm thick mild steel sheet and vitreous enamelled white, with latest, figures and the conventional skull and cross-bones in signal red colour (as per IS-5-1978 with latest amendment) on the front side. The rear side of the plate shall also be enamelled. The corner of the plate shall be rounded off with required material such as screws, wires clamps, nut bolts etc. complete.
Supplying and fixing of Angle/ channel/flat iron, V cross Arms reinforcement of RSJ jolt/ flat iron fittings for overhead lines and poles such as cross arms/ bracket/ clamps/ stiffness for poles etc. all required steel work including' cutting to size making proper shapes drilling scan welding etc. including nuts & bolts plan & spring wisher and other necessary material including one coat of red oxide and two coat of aluminum paint etc. as required.
11KV AB Switch three phase 400 Amp with complete fitting TP nang operated as per MPKVVCL requirement and specitifcation
Joint Sleeve (Aluminium) for Raccoon conductor as per MPKVVCL requirement and specitifcation
GAL . Horizontal and crass branching 4' centere with set of four bach clamps sutable for H-Beam as per MPKVVCL requirement and specitifcation
NOTE - 1) The contractor is responsible for approval of Transformer & Sub Station, VCB, H.T./L.T. lines/testing of all Material and meter from competent authority of Electrical Inspector and energisation/ commissioning of sub-station H.T./L.T.lineand necessary shut down from MPPKVVCL. No extra payment will be done for this job. 2) Quantities/items may increase/decrease as per site conditions. 3) Ready to carryout maintenance work if failure of any equipment/Items within 5 year period from the date of handing over.
LALIT KUMAR URODE
NEERAJ KUMAR JAIN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .