Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAdmitted-Finance | ₹29.9 L | L1 | Admitted-Finance |
| 2 | L2₹33.1 L+₹3.2 L (10.7%)Admitted-Finance | ₹33.1 L+₹3.2 L (10.7%) | L2 | Admitted-Finance |
| 3 | L3₹33.1 L+₹3.2 L (10.7%)Admitted-Finance | ₹33.1 L+₹3.2 L (10.7%) | L3 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical EMD/Fee not received |
| Sl No | Description | Qty | Unit | SAS ENTERPRISES L1 | A.P.B ELECTRICALS L3 | MSE CONTRACTOR L2 |
|---|---|---|---|---|---|---|
| 1.00Maintenance of Motor Control centres/Distribution Centres, LT panels/TPN switch Fuse Units (Refer Sec VI (MNC), Clause No.17.2). | ||||||
| 1.10 | Cubicle switch boards having number of vertical sections up to 3 | 36 | Nos. | 3,000 ₹1,08,000 | 3,900 ₹1,40,400 | 900 ₹32,400 Lowest |
| 1.20 | Cubicle switch boards having number of vertical sections more than 3 | 7 | Nos. | 3,200 ₹22,400 | 5,100 ₹35,700 | 500 ₹3,500 Lowest |
| 1.30 | Combination Switch fuse Units from 250A to 400A / Motor starters | 10 | Nos. | 650 ₹6,500 Lowest | 650 ₹6,500 Lowest | 700 ₹7,000 |
| 1.40 | Maintenance of Control Panel of Sewage Lift Pump / Siren Control Panel/ Submersible Pump Panel | 7 | Nos. | 1,800 ₹12,600 | 1,200 ₹8,400 | 800 ₹5,600 Lowest |
| 1.50 | Preventive maintenance of 1Ph / 3Ph LT Motors.( 1HP to 20 HP motor) | 25 | Nos. | 350 ₹8,750 | 600 ₹15,000 | 300 ₹7,500 Lowest |
| 1.60 | Preventive maintenance of 1Ph / 3Ph LT Motors.( 22.5 HP to 100 HP motor) | 25 | Nos. | 1,000 ₹25,000 | 800 ₹20,000 | 400 ₹10,000 Lowest |
| 1.70 | Preventive maintenance of Sewage liquid level probes Junction boxes | 12 | Nos. | 2,500 ₹30,000 | 400 ₹4,800 | 150 ₹1,800 Lowest |
| 2.00Cleaning of Motor Control Centres / Distribution Centres, LT Panels / TPN Switch Fuse Units / Squirrel Cage Induction Motors / Motor Starters as per the Specification and as directed by Engineer-in-charge | ||||||
| 2.10 | MCC Panel & Panel room | 258 | Nos. | 600 ₹1,54,800 | 720 ₹1,85,760 | 200 ₹51,600 Lowest |
Tender Value
₹32.3 L
EMD Value
₹64,600
Closing Date
22 Oct 2025, 3:00 pmClosed
Chief Engineer, CEG,GSO
Room No. 306, GSO Annex building, Kalpakkam - 603102
Maintenance of Motors and associated works
2025_GSO_879362_1
GSO/CTC/ESD/243/2025
Open Tender
Electrical Works
Item Rate
365 days
DAE Township, Anupuram
As stipulated in NIT/tender
8 documents required · 8 mandatory
₹0
₹64,600
12 Dec 2025
30 Sept 2025
23 Oct 2025
30 Sept 2025
22 Oct 2025
17 Oct 2025
1 Oct 2025 - 14 Oct 2025
Amount
Maintenance of Motor Control centres/Distribution Centres, LT panels/TPN switch Fuse Units (Refer Sec VI (MNC), Clause No.17.2).
Cubicle switch boards having number of vertical sections up to 3
Cubicle switch boards having number of vertical sections more than 3
Combination Switch fuse Units from 250A to 400A / Motor starters
Maintenance of Control Panel of Sewage Lift Pump / Siren Control Panel/ Submersible Pump Panel
Preventive maintenance of 1Ph / 3Ph LT Motors.( 1HP to 20 HP motor)
Preventive maintenance of 1Ph / 3Ph LT Motors.( 22.5 HP to 100 HP motor)
Preventive maintenance of Sewage liquid level probes Junction boxes
Cleaning of Motor Control Centres / Distribution Centres, LT Panels / TPN Switch Fuse Units / Squirrel Cage Induction Motors / Motor Starters as per the Specification and as directed by Engineer-in-charge
MCC Panel & Panel room
Control Panel & Panel room
Motor Starters units fixed on wall
Cleaning of Squirrel Cage Induction Motors
Motor Junction boxes ( Monobloc Motors)
Motor Junction boxes ( Submersible Motors)
Junction boxes ( Motorised operated Valves)
Cleaning of Sewage liquid level probes
Attending to break down calls for following types of Motors as per the scope of work . (Refer Sec VI (MNC), Clause No.15).
Single Phase Motors up to 2 HP
3 Phase Motors from 3 HP to 12.5 HP
3 Phase Motors from 15 HP to 35 HP
3 Phase Motors from 40 HP to 75 HP
Overhauling, Painting and test running of the following single/three phase motors as per the scope of work. (Refer Sec VI (MNC), Clause No.14.1).
Fractional HP Motors upto 0.5 HP
Above 0.5 HP to 2.0 HP Motor
3.0 HP / 5.0 HP Motor
7.5 HP / 10.0 HP Motor
12.5 HP / 15.0 HP Motor
20.0 HP / 25.0 HP Motor
30.0 HP/35.0/40.0 HP Motor
50.0/60.0 HP/75.0 HP Motor
More than 75.0 HP up to 100.0 H.P Motor
Rewinding of the following 415 Volts, LT Motors as per the scope of work (Refer Sec VI (MNC), Clause No.11.2)
Fractional HP Motor upto 0.5HP
Above 0.5 HP and up to 2.0 HP Motor
3.0 HP Motor
5.0 HP Motor
7.5 HP Motor
10.0 HP Motor
12.5 H.P. Motor
15.0 HP Motor
20.0 HP Motor
22.5 HP / 25.0 HP Motor
Complete Overhauling, Painting, Rewinding, Machining, Replacement of Bush Bearings, Thrust Bearings, Oil Seals, Dismantling & Assembling, Testing and Commissioning of following 415 Volts Submersible Motors as per the Specification and as directed by Engineer-in-charge
1.0 HP Submersible Motor
2.0 HP Submersible Motor
5.0 HP Submersible Motor
7.5 HP Submersible Motor
10.0 HP Submersible Motor
25.0 HP Submersible Motor
45.0 HP Submersible Motor
Synthetic enamel painting of the Fractional HP to 25 HP Induction Motor as per the detailed Specification and as directed by the Engineer - in - Charge
Fractional HP to 2 HP Motor
3 HP to 7.5 HP Motor
10 HP to 25 HP Motor
Supply and painting One coat on metallic surfaces of electrical equipment and other required surface at all levels with primer and following paint (Asian or approved brand, colour and manufacturer) to give an even shade including preparation of the surfaces, scaffolding complete all as per specifications and as directed by the Engineer-in-Charge. (Refer Sec VI (MNC), Clause No.3).
Synthetic enamel Paint
Machining and building up of damaged / worn-out Motor Shaft and Bearing housing in end cover as per the detailed specification.
From 3.0 to 10.0 HP Motor
From 12.5 to 25.0 HP Motor
Supply, replacement and testing of following HRC fuse links and Indication lamps as per the detailed specification and as directed by Engineer-in-charge.
HRC Fuse Link 16 A to 32 A Cylindrical Type HF Size 14 x 51 or Equivalent
HRC Fuse Link 63 A to 125 A DIN Type HN Size 00 or Equivalent
ON Push button with NO Element ( GREEN)
OFF Push button with NC Element ( RED)
10-25 mfd, 240/440V PVC polypropylene industrial type Capacitor for single phase motor
125A ,1000V Connector ( CSTSN6U)
Supply and replacement of Push button and panel LED indication lamp Dia '22.5'mm, various colours suitable for various operating voltages from 24 V up to 240 V AC/DC. (Refer sec VI (MNC), Clause No. 12)
Colour : Red/ Yellow/ Green/ Amber
Colour : White
Colour: Blue
Supply and replacement of the following contactors and accessories (Refer Sec VI (MNC), Clause No. 4) .
Control Contactor, AC-15 Rating MX0 - 22E ( 2 NO + 2 NC )
Power Contactors, AC3 Rating MNX 3Pole 18A
Power Contactors, AC3 Rating MNX 3Pole 32A
Power Contactors, AC3 Rating MNX 3Pole 40A
3pole Power Contactor (AC3) type ML1.5, 25A
3pole Power Contactor (AC3) type ML2, 32A
Bimetal over load relay (9-14)A for direct mounting on ML type contactor.
Bimetal over load relay (13-21)A for direct mounting on ML type contactor.
Bimetal over load relay (6-10)A for direct mounting on MNX type contactor.
Bimetal over load relay (9-15)A for direct mounting on MNX type contactor.
Bimetal over load relay (14-23)A for direct mounting on MNX type contactor.
Bimetal over load relay (20-33)A for direct mounting on MNX type contactor.
Type: MPR 300 or equivalent of range (32-88) A standrad range or equivalent.
Auxiliary Contact (2NC + 2 NO) for 3 phase, 415 Volt Motor Starter
Supply and replacement of Electronic Timer suitable for Automatic Star Delta Starter with Timing Range: 3 sec to 120 sec, Voltage: 240 - 415 V AC with 1 NO (Star) + 1 NO (Delta) as per the detailed specification and as directed by Engineer-in-charge
Supply and Installation of LT panel accessories as per the detailed specification
Lock type panel knob
Screw type panel knob
Supply, cleaning the floor, proper pasting and installation of following insulating mat as per specification. (Refer Sec VI, Clause No.25).
2.0 mm thickness, Max useable voltage 3.3kV, AC Proof voltage 10kV for 3 minutes, AC dielectric strength 30kV RMS Insulating Mat confirming to IS:15652
Supply and replacement of following Motor Bearings during overhauling (Refer Sec VI (MNC), Clause No.14
Bearing Model No:6203 2Z
Bearing Model No:6204 2Z
Bearing Model No:6205 2Z
Bearing Model No:6206 2Z
Bearing Model No:6208 2Z
Bearing Model No:6306 2Z
Bearing Model No:6308 2Z
Bearing Model No:6311 2Z
Bearing Model No:6312 2Z
Supply, Replacement / Installation, testing and commissioning of following 3 Core Flat Type Cable as per the detailed specification and as directed by Engineer-in-charge.
3 Core 2.5 Sqmm Cu.Cable
3 Core 6 Sqmm Cu.Cable
3 Core 10 Sqmm Cu.Cable
3 Core 16 Sqmm Cu.Cable
Supply and replacement of junction box as per the detailed specification and as directed by Engineer-in-charge
Three Phase Submersible Junction Box with Connectors
250 x 250 x 120 mm MS Junction Boxes
Supply, installation, testing and commissioning of the following Push Button Stations with FRP Junction Boxes (IP 65) including all required accessories as per the detailed pecification.
Supply and replacement of Switch Disconnector fuse ,125A, 690V, AC-23A with Three Nos of 125A HRC Fuse as per the detailed specification and as directed by Engineer-in-charge
Connection of 3 phase Pump Motors at various locations as per the Specification and as directed by Engineer-in-charge
Disconnection of 3 phase Pump Motors at various locations as per the Specification and as directed by Engineer-in-charge
Maintenance of Earth Pits including supply of Sodium Bentonite, and measurement of Earth Pit Resistance as per the specification. (Refer Sec VI (MNC), Clause No.2).
Maintenance of Earth Pits and measurement of Earth Pit Resistance as per the specification. (Refer Sec VI (MNC), Clause No.2).
Repair of Earth pit
Repair of earth pit chamber after removing and disposing old/damaged chambers supply and installing new chamber as per drawing No. IGC/ESD/5060/1008/1. (Refer Sec VI (mnc) clause no.2)
Supply, installation and testing of GI Pipe Earth Electrode as per IS: 3043 including RCC Chamber and RCC cover slab as per Drawing Nos. IGC/ESD/5060/1007/1 & IGC/ESD/5060/1008/1 are enclosed. (50 Kg. Each Bentonite & Charcoal shall be provided for each earth pit). (Refer Sec VI, Clause No.12.4).
Supply, fabrication and installation of the following size of Hot dip Galvanised GI Flats including excavation and refilling as per the detailed specification. No cutting or drilling permitted after galvanisation.Refer Sec VI, Clause No.12.9).
25 x 6 mm GI flat
Supply, fabrication and installation of the following size of Hot dip Galvanised GI Flats in Built in trenches on walls, poles, RCC Concrete and through embedded pipes as per the detailed specification. No cutting or drilling permitted after galvanisation. (Refer Sec VI, Clause No.12.9).
25 x 6 mm GI flat
Loading, Transportation, Unloading at site, Laying, Testing and Commissioning of one number PVC/HRPVC/XLPE insulated and PVC sheathed Stranded Aluminium/copper conductor power cable of 1.1 KV grade of following sizes direct in ground including excavation, sand/m-sand cushioning, protective covering with chamber burnt/cement bricks on sides & top, refilling the trench and providing RCC route indicator etc as required (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3)
3/3.5/4 Core x upto 25 Sqmm
3/3.5/4 Core x above 25 to 3/3.5/4 Core X up to 120 sqmm
Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100 Volts Grade PVC/HRPVC/XLPE insulated, Stranded Aluminium/copper conductor cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3)
3/3.5/4core x Upto 25 sqmm
3/3.5/4Core x above 25 & up to 120 sqmm
Retrieval of the existing one number PVC/HRPVC/XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following sizes laid direct in ground including Removal of end termination, excavation of trenches, retrieving of bricks and back filling as per the detailed specification.(Refer Sec VI, Clause No.5)
3/3.5/4 Core Upto 25 Sqmm
3/3.5/4 Core Above 25sqmm & upto120 sqmm
Retrieval of the already laid one number 1100 Volts Grade XLPE/HRPVC insulated, Stranded Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and from embedded pipes including removal of end termination GI spacer, clamps etc as per the detailed specification. (Refer Sec VI, Clause No.5)
3/3.5/4 Core Upto 25 Sqmm
3/3.5/4 Core Above 25sqmm & upto120 sqmm
Retrieval of the already laid one number PVC insulated & Sheathed 1.1kV grade copper Conductor, armoured control Cables of following sizes laid direct in ground including retrieval of end termination, excavation of trenches, retrieving of bricks and back filling of soil etc as per the detailed specification .(Refer Sec VI, Clause No.5)
Upto 14 C x 2.5 Sqmm
End Termination of the following sizes of Aluminium Conductor PVC Insulated and sheathed armoured UG Cable using Single Compression, Heavy Duty, Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Comet or equivalent make Aluminium crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1).
4 Core x10 Sqmm
4 Core x 16 Sqmm
3.5/4 C x 35 sq.mm
3.5/4C x 50/70 sq.mm
Excavation in hard soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift upto 1.5 Mtrs. including neat banking as per detailed specification. (Refer Sec VI, Clause No.2)
MSE CONTRACTOR (BID ID -3302563)
A.P.B ELECTRICALS (BID ID -3300548)
Bidder Name
SAS ENTERPRISES
MSE CONTRACTOR
A.P.B ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.39 MB
GSOCTCESD243Annexure2to4.pdf
Tender Documents • 0.35 MB
GSOCTCESD243SectionVIMNC.pdf
Tender Documents • 0.64 MB
GSOCTCESD243FormOfAgt.pdf
Tender Documents • 0.29 MB
GSOCTCESD243TechBidFormsACDFGH.xls
Tender Documents • 0.13 MB
GSOCTCESD243SectionVI.pdf
Tender Documents • 7.25 MB
GSOCTCESD243ParOne.pdf
Tender Documents • 2.97 MB
BOQ_924309.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .