| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC | L1 | Accepted-AOC Accepting being lowest | |
| 2 | L2₹24.8 L+₹1.3 L (5.69%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹28.4 L+₹5.0 L (21.1%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L3 | Rejected-Finance Rejected being other than lowest | |
| 4 | L4₹28.6 L+₹5.1 L (21.5%)Rejected-Finance | L4 | Rejected-Finance Rejected being other than lowest | |
| 5 | L5₹31.9 L+₹8.4 L (35.9%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L5 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
18 Aug 2022, 6:00 pmClosed
Capt Krithika S Offg Garrison Engineer
Military Engineer Services, Garrison Engineer (South) Ahmednagar - 414002
Repair/Maint of pumping machinery, panel boards, stabilizers and external water supply GI/CI/DI Pipe Lines, NRV, Control Valves and certain misc E/M work at MIC and S under GE (S) Ahmednagar
2022_MES_540082_1
8906/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Ahmednagar
Class D Cat a (ii)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹70,000
Yes
7 Sept 2022
22 Jul 2022
20 Aug 2022
22 Jul 2022
18 Aug 2022
4 Aug 2022
22 Jul 2022 - 28 Jul 2022
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying pipe line, sluice valve etc and getting out in soft & loose soil complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil including making good of disturbed surfaces complete all as specified and directed.
Removing excavated soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for cutting the existing bituminous road / PCC Hard Standing upto 75cm in depth, 60cm in width and getting out excavated materials, making good the damaged portion after laying of pipes by returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick and PCC 1:2:4 type B1 using 20mm graded stone aggregate upto 30cm depth from top of the road all as specified and directed.
M&L for repairs / rectification of leakages of existing GI tubing 15 mm bore, laid in trenches, floors or on wall, roof by replacing short piece length up to 0.50 mtr, including fittings such as union, sockets, nipples, tees, elbows, reducers etc including threading, cutting, jointing complete and excavation & earthwork upto 01 cum as in trenches all as specified and as directed.
All as per serial item No. 05 but 20 mm bore pipe.
All as per serial item No. 05 but 25 mm bore pipe.
All as per serial item No. 05 but 40 mm bore pipe.
All as per serial item No. 05 but 50 mm bore pipe.
All as per serial item No. 05 but 80 mm bore pipe.
All as per serial item No. 05 but 100 mm bore pipe.
M&L for repairs / rectification of leakages of existing UPVC/CPVC pipe, 15 mm bore, laid in trenches, floors or on wall, roof by replacing new fittings such as union, sockets, nipples, tees, elbows, reducers etc including threading (if required), cutting, jointing complete all as specified and as directed.
All as per serial item No. 12, but 20 mm bore pipe.
All as per serial item No. 12, but 25 mm bore pipe.
All as per serial item No. 12, but 40 mm bore pipe.
All as per serial item No. 12, but 50 mm bore pipe.
M&L for UPVC PIPES, 15 mm bore (Pressure rating 10 kgf/cm²), laid in trenches / floors or fixed to wall in any length with screwed/socket joints together with all UPVC fitting such as sockets, bends, elbows, tees, reducers, unions, jointing materials etc and pressure testing, washing out complete including dismantling, taking out old corroded GI pipe complete all as specified and as directed.
All as per serial item No. 17 but 20 mm bore pipe.
All as per serial item No. 17 but 25 mm bore pipe.
All as per serial item No. 17 but 40 mm bore pipe.
All as per serial item No. 17 but 50 mm bore pipe.
Taking up or down choked GI water pipes, 15 mm bore, including all fittings with spigot and socket ends, proper cleaning by internal brushing, removing chalkings and refixing / relaying in place, jointing, pressure testing and washing out complete all as specified and as directed.
All as per serial item No. 22 but 20 mm bore pipe.
All as per serial item No. 22 but 25 mm bore pipe.
All as per serial item No. 22 but 40 mm bore pipe.
All as per serial item No. 22 but 50 mm bore pipe.
All as per serial item No. 22 but 80 mm bore pipe.
All as per serial item No. 22 but 100 mm bore pipe.
M&L for GI tubing, medium grade, 15 mm bore, laid in trenches / floors or fixed to wall in any length with screwed and socket joints together with all galvanised GI fitting such as sockets, bends, elbows, tees, reducers, unions, jointing materials etc and pressure testing, washing out complete including dismantling, taking out old corroded pipe complete all as specified and as directed.
All as per serial item No. 29 but 20 mm bore pipe.
All as per serial item No. 29 but 25 mm bore pipe.
All as per serial item No. 29 but 40 mm bore pipe.
All as per serial item No. 29 but 50 mm bore pipe.
All as per serial item No. 29 but 80 mm bore pipe.
All as per serial item No. 29 but 100 mm bore pipe.
M&L for gun metal or bronze, globe/ball valve, 15 mm bore, ISI Marked, screwed both ends, suitable for GI tubing with side way operating GI lever handle, including taking down old unserviceable valve of any type/make complete all as specified and as directed.
All as per serial item No. 36 but 20 mm bore
All as per serial item No. 36 but 25 mm bore
All as per serial item No. 36 but 40 mm bore
All as per serial item No. 36 but 50 mm bore
Taking up CI/DI water mains, 80 mm bore, including all fittings with spigot and socket ends, including burning out joints, removing lead and proper cleaning by internal brushing, removing chalkings all as specified and as directed.
All as per serial item No. 41 but 100 mm bore pipe.
All as per serial item No. 41 but 150 mm bore pipe.
All as per serial item No. 41 but 200 mm bore pipe.
All as per serial item No. 41 but 250 mm bore pipe.
All as per serial item No. 41 but 300 mm bore pipe.
All as per serial item No. 41 but 350 mm bore pipe.
M&L for laying, jointing ductile Iron pipe, 80 mm bore with spigot and socket ends, centrifugally cast, class DI-K9, cement mortar lining with portland slag cement as per IS 455: 1989, metallic zinc coating as per annex A of IS 8329 with finishing layer of bituminous coating as per annex C of IS 8329, suitable for rubber gasket joint, conforming to IS: 8329 : 2000, ISI marked, in any length, laid in trenches, pressure testing, washing out complete including dismantling, taking out old corroded pipe line with all fittings complete all as specified and as directed.
All as per serial item No. 48 but 100 mm bore pipe.
All as per serial item No. 48 but 150 mm bore pipe.
All as per serial item No. 48 but 200 mm bore pipe.
All as per serial item No. 48 but 250 mm bore pipe.
All as per serial item No. 48 but 300 mm bore pipe.
All as per serial item No. 48 but 350 mm bore pipe.
M&L for drilling, tapping, cast iron / ductile iron water main in position for branch connection with straight, plain brass ferrule of same size for the internal dia 15mm complete all as specified and as directed.
All as per serial item No. 55 but internal dia 20mm.
M&L for CI / DI fittings and specials such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc.), Tee pieces, single branch, "Y" junction, double branch, cross (all sockets or socket and spigot), collars, caps, plugs, connecting pieces, one end flanged and other end socketed or spigot ends or all socketed / spigot ends etc for CI/DI pipes up to 150 mm bore complete all as specified and as directed.
All as per serial item No. 57 but CI/DI pipes 200 to 300 mm bore
M&L for rectification of the leakages of CI/DI pipe, 80 mm bore, joint with and including lead wool, caulking etc.complete all as specified and as directed.
All as per serial item No. 59 but 100 mm bore pipe.
All as per serial item No. 59 but 150 mm bore pipe.
All as per serial item No. 59 but 200 mm bore pipe.
All as per serial item No. 59 but 250 mm bore pipe.
All as per serial item No. 59 but 300 mm bore pipe.
All as per serial item No. 59 but 350 mm bore pipe.
Burning out lead joint in position for 80 mm bore pipe, including removing old lead complete all as specified and as directed.
All as per serial item No. 66 but for 100 mm bore pipe.
All as per serial item No. 66 but for 150 mm bore pipe.
All as per serial item No. 66 but for 200 mm bore pipe.
All as per serial item No. 66 but for 250 mm bore pipe.
All as per serial item No. 66 but for 300 mm bore pipe.
All as per serial item No. 66 but for 350 mm bore pipe.
M&L for run lead joint for 80 mm bore CI pipe including pressure testing complete all as specified and as directed.
All as per serial item No. 73 but for 100 mm bore pipe.
All as per serial item No. 73 but for 150 mm bore pipe.
All as per serial item No. 73 but for 200 mm bore pipe.
All as per serial item No. 73 but for 250 mm bore pipe.
All as per serial item No. 73 but for 300 mm bore pipe.
All as per serial item No. 73 but for 350 mm bore pipe.
M&L for Styrene Butadiene Rubber Gasket (IS : 5382) joint, suitable for spigot and socket ends DI Pipes, 80mm bore, Class K9, including pressure testing complete all as specified and as directed.
All as per serial item No. 80 but for 100 mm bore pipe.
All as per serial item No. 80 but for 150 mm bore pipe.
All as per serial item No. 80 but for 200 mm bore pipe.
All as per serial item No. 80 but for 250 mm bore pipe.
All as per serial item No. 80 but for 300 mm bore pipe.
All as per serial item No. 80 but for 350 mm bore pipe.
M&L for mechanical joint for 80 mm bore CI/DI pipe, having 2 Nos CI / DI sockets, 1No CI / DI collar and 2Nos Styrene Butadiene Rubber Gaskets alongwith nuts, bolts, washers , gaskets etc. including cutting CI / DI pipe and reducing to required length for insertion in position of mechanical joint complete all as specified and as directed.
All as per serial item No. 87 but for 100 mm bore pipe.
All as per serial item No. 87 but for 150 mm bore pipe.
All as per serial item No. 87 but for 200 mm bore pipe.
All as per serial item No. 87 but for 250 mm bore pipe.
All as per serial item No. 87 but for 300 mm bore pipe.
All as per serial item No. 87 but for 350 mm bore pipe.
M&L for taking out 80 mm bore size, sluice valves, , re-facing, re-grinding, including taking apart and reassembling, re-fixing, replacing nuts, bolts, washers and replacement of rubber gasket, gland, packing, brass check nuts complete all as specified and as directed.
All as per serial item No. 94 but 100 mm bore size
All as per serial item No. 94 but 150 mm bore size
All as per serial item No. 94 but 200 mm bore size
All as per serial item No. 94 but 250 mm bore size
All as per serial item No. 94 but 300 mm bore size
M&L for 80 mm bore size sluice valve, cast iron, long body, both ends flanged as per IS-14846 and drilled with stainless steel spindle, iron wheel head and as per pressure rating PN 1.6, Class I, ISI marked, alongwith nuts, bolts, washers , gaskets etc. including dismantling and taking out unserviceable sluice valve from valve chamber / trenches complete all as specified and as directed.
All as per serial item No. 100 but 100 mm bore size
All as per serial item No. 100 but 150 mm bore size
All as per serial item No. 100 but 200 mm bore size
All as per serial item No. 100 but 250 mm bore size
S&F 100 mm bore size, Rubber Lined Non Return Valve B-02 ( Ball type), cast iron body, flanged end, including neophrene ball and by pass arrangement complete including suitable flanges, nuts, bolts, washers and rubbber gaskets including dismantling and taking down old unserviceable valve all as specified and as directed.
All as per serial item No. 105 but 150 mm bore size
S&F 80 mm bore size, CI ball foot flanged B-05 (N) valve, suitable as per existing valve including taking down old unserviceable valve all as specified & as directed.
All as per serial item No. 107 but 100 mm bore size
All as per serial item No. 107 but 150 mm bore size
All as per serial item No. 107 but 200 mm bore size
S&F 100 mm bore size CI/DI strainer valve, suitable as per existing valve including taking down old unserviceable valve all as specified & as directed.
All as per serial item No. 111 but 150 mm bore size
All as per serial item No. 111 but 200 mm bore size
M&L for construction of valve pit/chamber of Internal dimensions 1100 mm x 1100 mm x 1100 mm, using PCC 1:4:8, type D-2, using 40mm graded stone aggregates for foundation, 23 cm thick, brick wall built in cement mortar (1:4) ,15 mm thick rendering all around the brick work in cement mortar (1:6), 75 mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregates in coping including necessary form work, 3coats of white wash on rendered surfaces and on coping, 2 mm thick mild steel top sheet cover with frame made out of 40x40x6 mm angle iron, locking arrangement, including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer including demolition of existing valve chamber and clearing the debris complete all as specified and as directed.
All as per serial item No 114 here-in-before but internal dimensions 900 mm x 900 mm x 900 mm
M&L for taking down carefully, existing unservicable water level Indicator from OHT/ UG SUMPS and repair with replacement of heavy duty polythene floating ball, nylon rope of 10 mm dia, run over CI Pully of 65mm dia, MS Sheet made of 18 gauge as required at site, fixed on angle iron frame of 40 x 40 x 6 mm size complete including calibrated scale gms sheet duly marked with approved radium paint / best quality radium tape , glowing in night, indicator point and proper fixing arrangements all as specified and as directed by Engineer-in-Charge.
S&F water meter, Class B of size 200 mm, flanged type, cast iron body complete including suitable flanges, nuts, bolts, washers and rubbber gaskets including taking out existing water meter all as specified and as directed.
S&F in repairs, star coupling, heavy duty, Styrene Butadiene Rubber, suitable for 50/25/15/7.5 HP pump or motor all as specified & as directed.
Taking LT shutdown, dismantle and remove the 50 HP electric motor of mono block / coupled pump set from existing foundation / position, shifting to authorized workshop for the repair work, removing the burnt winding, cleaning rotor / stator slots, re-winding the motor with super enameled copper wire of the size equivalent to the original winding including insulated packing materials, varnishing, heating, drying etc, replacing star bush coupling, replacing the bearings, reassembling and installing back at it's original position, aligning, testing and commissioning on full load for 8 hrs continuous running all as specified and as directed
All as per serial item 119 but 25 HP electric motor of mono block / coupled pump set
All as per serial item 119 but 15 HP electric motor of mono block / coupled pump set
All as per serial item 119 but 10 HP electric motor of mono block / coupled pump set
All as per serial item 119 but 7.5 HP electric motor of mono block / coupled pump set
S&F in repairs, CI impeller for 50 HP pumps all as specified and as directed.
S&F in repairs, bearing for 50 HP pumps all as specified and as directed.
S&F in repairs, bearing end plate for 50 HP pumps all as specified and as directed.
S&F in repairs, MS shaft for 50 HP pumps all as specified and as directed.
S&F in repairs, MS coupling for 50 HP pumps all as specified and as directed.
S&F in repairs, Seal for 50 HP pumps all as specified and as directed.
S&F in repairs, Motor fan for 50 HP pumps all as specified and as directed.
S&F in repairs, Bush for 50 HP pumps all as specified and as directed.
S&F in repairs, CI impeller for 25 HP pumps all as specified and as directed.
S&F in repairs, bearing for 25 HP pumps all as specified and as directed.
S&F in repairs, bearing end plate for 25 HP pumps all as specified and as directed.
S&F in repairs, MS shaft for 25 HP pumps all as specified and as directed.
S&F in repairs, MS coupling for 25 HP pumps all as specified and as directed.
S&F in repairs, Seal for 25 HP pumps all as specified and as directed.
S&F in repairs, Motor fan for 25 HP pumps all as specified and as directed.
S&F in repairs, Bush for 25 HP pumps all as specified and as directed.
S&F in repairs, CI impeller for 10 HP pumps all as specified and as directed.
S&F in repairs, bearing for 10 HP pumps all as specified and as directed.
S&F in repairs, bearing end plate for 10 HP pumps all as specified and as directed.
S&F in repairs, MS shaft for 10 HP pumps all as specified and as directed.
S&F in repairs, MS coupling for 10 HP pumps all as specified and as directed.
S&F in repairs, Seal for 10 HP pumps all as specified and as directed.
S&F in repairs, Motor fan for 10 HP pumps all as specified and as directed.
S&F in repairs, Bush for 10 HP pumps all as specified and as directed.
S&F in repairs, CI impeller for 7.5 HP pumps all as specified and as directed.
S&F in repairs, bearing for 7.5 HP pumps all as specified and as directed.
S&F in repairs, bearing end plate for 7.5 HP pumps all as specified and as directed.
S&F in repairs, MS shaft for 7.5 HP pumps all as specified and as directed.
S&F in repairs, MS coupling for 7.5 HP pumps all as specified and as directed.
S&F in repairs, Seal for 7.5 HP pumps all as specified and as directed.
S&F in repairs, Motor fan for 7.5 HP pumps all as specified and as directed.
S&F in repairs, Bush for 7.5 HP pumps all as specified and as directed.
S&F in repairs, single phase DOL starter including all components suitable for 1.5/3/5HP submersible pump set having relay range 06-10 Amps or as per existing all as specified and as directed.
S&F in repairs, three phase DOL starter including all components suitable for 1.5/3/5 HP submersible pump set having relay range 11- 18 Amps or as per existing all as specified and as directed.
S&F in repairs, three phase DOL starter including all components suitable for 10 HP motor, having relay range 13- 21 Amps or as per existing all as specified and as directed.
S&F in repairs, single phase/three phase preventer, suitable for fully automatic Star / Delta starter or Direct - on - Line starter all as specified and as directed.
S&F in repairs, pressure gauge, stem with dual dial type, 0 - 7Kg / Cm² and 0 - 100 Lb / Sq inch all as specified and as directed.
Supply only Calcium hypo chlorite, dry free flowing and free from lumps of following generic specification : (a) Available Chlorine - Min 65% (b) Particle size (passing through 1.70 mm IS sieve) - Min 99.5% (c) Water insoluble matter - max 6% (d) Chalcium hydroxide - max 4% (e) Sodium chloride - max 15 % Make : Any make approved by E-in-C
Taking down carefully, existing unservicable electric water level Indicator from OHT/ UG SUMPS and repairing the same by replacing receiver, transmeter, nodes,sensor,Service cable,existing MCB, etc as required and proper fixing arrangements all as specified and as directed.
S&F in repairs, ML6/ML4/ML2 starter timer of suitable/existing capacity for 50/25 HP Pump set starter 415/440 V 50 Hz , complete all as specified and as directed.
M&L for cement concerete type B2, 1:2:4, using 40 mm graded stone aggregates as in foundation of size 6 feet x 3 feet, 3 feet high including necessary formwork, rolled mild steel channel, C type, fixing with nut bolts and fixing of centrifugal pump, Suction/Delivery pipes & fittings including dismantling/demolition of existing foundation all as per specified and as directed.
Supply only in replacement, fire fighting hose pipe, externally coated rubber line with SS coupling and nozzle, ISI marked , 50mm dia, 30 Rm long all as per specified and as directed.
m/s shivam tools and equipment
SKS Electricals
Mangesh Murlidhar Darwade
Shri Sai Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .