Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.6 LAccepted-Finance | L1 | Accepted-Finance BEING L1 BIDDER | |
| 2 | L2₹57.0 L+₹41,184 (0.73%)Rejected-Finance NICHUPATTY BOLPUR BIRBHUM | BIRBHUM | WEST BENGAL | 713129 | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹57.5 L+₹91,220 (1.61%)Rejected-Finance | L3 | Rejected-Finance BEING L3 BIDDER |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
14 Aug 2025, 3:00 pmClosed
Executive Engineer, Birbhum Electrical DivisionPWD
Office of the EXECUTIVE ENGINEER P.W.DTE. Birbhum Electrical Division P.O. Suri,Dist Birbhum, Pin 731101
Renovation and Renovation of Electrical Installation and Electrical Panel of the Boys hostel and Pharmacy building at Sree Ramkrishna Silpa Vidyapith,Project ID ET252635414S00
2025_WBPWD_885097_1
BIRED/14/e-NIQ(1st call) of 2025-2026
Open Tender
ELECTRICAL WORKS ORG
Item Rate
180 days
Suri
Please refer Tender documents.
4 documents required · 4 mandatory
₹1.2 L
Executive Engineer, Birbhum Electrical DivisionPWD
20 Jan 2026
30 Jul 2025
18 Aug 2025
30 Jul 2025
14 Aug 2025
1 Aug 2025
1 Aug 2025
Amount
SUB-HEAD 1--DISTRIBUTION WIRING Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand:Polycab/Finolex/Gloster/RR kabel) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch(Brand; Anchor/Havells/L&T) fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 8 mtr [E-15/5(c)]
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand:Polycab/Finolex/Gloster/RR kabel) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Make - Legrand Mylinc/Cabtree/Anchor Roma) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 8 mtr [ E-25/4(c)]
SUB-HEAD 2--CUTTING CHANEL & WIRE LAYING Cutting channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge polythene pipe dia as stated below, by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire as per GS. i) 13 mm dia 3 mm thick.[ E-2/5(a)]
ii) 19 mm dia 3 mm thick [E-2/6(a)]
iii) 25 mm dia 3 mm thick [E-2/7(a)]
Supplying and Drawing 1.1 KV single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire(Brand:Polycab/Finolex/Gloster/RR kabel) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. i)2x(1.5 sqmm)+1x(1.5 sqmm) [E-9/1(b)]
ii) 2x(2.5 sqmm)+1x(1.5 sqmm) [E-9/1(s)]
iii) 2x (6 sqmm) + 1x (4 sqmm) [E-9/1(y)]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. i) 1.5 sq.mm.
ii) 2.5 sq.mm
iii) 4 sq.mm
iv) 6 sq.mm
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand: Polycab/Finolex/Gloster/RR kabel) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy.fittings as required i) 2x(1.5 sqmm)+1x(1.5 sqmm) ECC [ E-14/ 1(a)i]
ii) 2 x (4 sqmm) + 1 x (2.5 sqmm) [ 1(a) iii / E- 14 ]
SUB HEAD 3-- SUPPLY & LAYING OF CABLE Supply of following XLPE insulated & Sheathed cables for Working Voltage up to 1100 Volts of following sizes [Make- Havells / Polycab/ KEI /Finolex/Gloster/RR kabel] i) 2 core 6 sq. mm. multy stranded alluminium conductor Armoured cable.
ii) 4 core 10 sq. mm. multy stranded Aluminium conductor Armoured cable.
iii) 4 core 25 sq. mm. multy stranded Aluminium conductor Armoured cable.
iv) 4 core 35 sq. mm. multy stranded Aluminium conductor Armoured cable.
v) 4 core 50 sq. mm. multy stranded Aluminium conductor Armoured cable.
vi) 4 core 95 sq. mm. multy stranded Aluminium conductor Armoured cable.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. i) 32 mm dia [F-6/11(b)]
ii) 40 mm dia [F-6/11(C) ]
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core. [ 3(a)/ F- 1 ]
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [2(a)/ F- 1]
Laying of cable from 3½ core 35 sq mm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [2(c)/ F- 1]
Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting [2(e)/ F- 1]
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed [F-2/1(a)]
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed. [F-2/1(b)]
Laying of cable as below, after cutting floor /pavement / wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish Incl. 2x 10 GI [Hot Dip] Wire as Earthing as per GS. Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc. [F-3/5(ii)]
from 2.5 to 35 sqmm at an average depth of 75 mm in floor / pavement/wall etc incl earthing attachment in 2x 10 SWG GI [Hot Dip] Wire [F-3/5(i)]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. i) 2 core 6 sq. mm
ii) 4 core 10 sq. mm
iii) 4 Core 25 Sq. mm
iv) 4 Core 35 Sq. mm
v) 4 Core 50 Sq. mm
vi) 4 Core 95 Sq. mm
SUB-HEAD 4--VTPNDB,HTPNDB, SPNDB,SFU,MCB ETC. Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. 100A (L&T Make ) [D-3/4(a)]
Supplying and fixing following rating porcelin fuse base & bridge on Suitable size 50mm X 6mm MS flat on wall incl. painting & mending good the damage. 200A [Cat No.- IHKKRT4200] [Make- Havells]
Supplying and fixing Sheet steel Main Switches on flat iron frame on wall. 240V DP with fuse on L&N 15/16 A (Make:Havells/HPL)
Supplying and fixing double-door Vertical TPN MCB Distribution Board upto 160A with IP-42/43 protection, concealed in wall as per GS. 8 Way [Make:- Legrand] [15/D-11]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection as per GS. 100A [Legrand] [ 10/ D- 8 ]
Supplying and fixing double-door Horizontal TPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. i) 6 Way[ Legrand ]
ii) 4 Way[ Legrand ]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. i) 2+12 Way [Make:- Legrand]
ii) 2+4 Way [Make:- Legrand]
iii) 2+8 Way [Make:- Legrand]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics as per GS. i) 6-32 A SP [Make:- Legrand]
ii) 40/63 A TP [Make:- Legrand]
iii) 32 A TP [Make:- Legrand]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs as per GS. i) 32 A DP [Make:- Legrand]
ii) 32A FP [Make:- Legrand]
iii) 40 A DP [Make:- Legrand]
iv) 63A FP [Make:- Legrand]
S& F of MCB Enclosure 2way/4way (Legrand) [ k-1]
Supply & fixing Two/ Three Pole Power Contactor with 230V coil voltage, following Ampere rating on din rail of existing DBs and necessary connection. [Make:- L&T]. 18A, 3 Pole, Model:- MNX18, [3 modules] For Group Control.
Supply & Fixing 240 V, 6 A Piano key type switch ( Brand:Anchor/Havells/L&T) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
SUB-HEAD 5--PLUGS & SOCKETS Supply & Fixing 240 V, 3 nos. 6 A & 1 no. 16 A 3 pin Modular type plug socket with 3 nos. 6A & 1 no. 16 A Modular type switch ( [Make - Legrand Mylinc/Cabtree/Anchor Roma), 25A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket [Make - Legrand Mylinc/Cabtree/Anchor Roma) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board as per GS.[E-18/9(b)]
Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4 nos. 6 A Piano key type switch, & indicator & 16 A Kit-Kat flush type fuse (Make:Anchor/Havells/L&T) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator & necy. Connections. [For AC] [PWD/GS Page: E-17 Item: 5b] [Make - Legrand Mylinc/Cabtree/Anchor Roma]
Supply & Fixing 240 V, 25 A, Modular type starter (Brand North-West/Legrand/L&T/Crabtree) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc [PWD/GS Page: E-19 Item: 17]
SUB-HEAD 6--SITC OF AIR CONDITIONER. Supply, Installtion, Testing and Commissioning of 1.95 Tr - 2.2 Tr Split type AC machines having Cooling Capacity range (6.8KW- 7.7.0 KW) with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating - 2/3 (EER range 3.5 to 3.99), Air flow range CFM ( 780 - 880), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 ( Part - I & Part - II) with all amendments ( Make- O-General, Model-ASGA24BUTA-B/ Mitsubishi Heavy Duty, Model-SRK25CSS-S6/A )
Supply & fixing of following diameter heavy gauge copper pipe line from indoor unit to outdoor unit including suitable keno foam insulation & electrical line from indoor unit to outdoor unit with following diameter copper wire cable. 5/8"(15.88mm) & 1/4"(6.35mm) heavy gauge copper pipe [Make:Ryoku/Nippon/Godrej] with 4 X 2.5 Sq.mm copper wire cable [Brand: Polycab/Finolex/Gloster/RR kabel].
Supply & laying Schedule 40 PVC Drain Pipe for drain out the water from cooling unit incl. Covering with nytrile tape insulation on following dia HDPE [Make:Suprime/Oriplast medium guage]. 20 mm dia Schedule 40 PVC pipe
Supply and drawing 4 core 2.5 sq.mm PVC insulated sheeted wire for connecting the outdoor to indoor communicaion supply.( Brand: Polycab/Finolex/Gloster/RR kabel)
SUB-HEAD 7--ERECTION & INSTALLATION OF GI MINI POLE 1.5 M Hot Dip Galvanized mini Pole for post top light with Top Dia. (A/F) 70 mm and Bottom Dia. (A/F) 135 mm. Thickness of the sheet is 3 mm. Base Plate Dimension (LxWxT) 200x200x8 mm. The pole has 4-M16 Foundation Bolt as per Gs (Make – Utkarsh/Bajaj/Surya/ Valmont/ Transrail)
Charges for providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base of pole incl. S&F 3mtr long Earth spike with S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat upto 2 mtr on muffing with GI saddles as required and connection to pole incl. bolts, nuts, washers etc. for street light wiring.
Supplying and fixing waterproof & dustproof PVC (Poly Carbonate, SMC/FRP) cable loop box[Syntex/similar] having thickness 4-6 mm comprising Neutral Link on DIN rail, 2 Pole 6 A MCB, 4way TPN Connectors Color Red with rubber gasketted, metalic hinged PVC Door or cover with brass machine screws etc., earthing terminal with lug, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. incl. Inter connection with suitable size of copper wire including painting with anticorrosive paint as required / As per Choice of EIC. (300x250x100)mm (Make-Sintex)
Wiring with 3X 1.5 Sqmm PVC copper wire ( Brand: Polycab/Finolex/Gloster/RR kabel) in 13mm dia polythene pipe from loop box to LED fitting. (average run 4mt)
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. [c-3/18]
Painting of Steel Tubular Pole and mine Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint. [Upto 9.0 mtr. long pole] i) One coat of red lead/Zinc chromate priming [7A(a)(i) /H-2]
ii) 1st coat of synthetic enamel paint over the primer
ii) 2nd coat of synthetic enamel paint over the 1st coat
Supply of 4 MTRS GI OCTAGONAL POLE FABRICATED PART AS PER DIMENSION :T0P DIA - 70 mm, BOTTOM DIA -130 mm, (SECTION LENGTH - 3000 mm) THICKNESS - 3 mm,BASE PLATE - 200 mm x 200 mm x 12 mm.. FOUNDATION BOLT - M16 x 450 mm x 4 nos 'J' type bolts (Make – Utkarsh/Bajaj/Surya/ Valmont/ Transrail)
Supply of 1000 mm Double Arm Bracket made of 40 NB /48.3 OD Mild Steel Pipe as per IS:1161 suitable to insert at Pole Top A/F 70 (Utkarsh/Bajaj/Surya/ Valmont/ Transrail)
Construction of suitable Shallow foundationupto 4 mtr. Octagonal Pole with M-20 gradeconcrete for Pole considering soil bearing capacity (SBC) 10T/sq. mtr. at 2 Mtr. depth with all materials and labour payment made as per PWD civil schedule & as per direction,of EIC. Erection of Pole by using of lifting,equipment like hydra etc. and fixing of foundation bolts, anchor plate etc. withnecessary arrangement & Testing & commissioning of all electrical equipment of Pole like led fixtures, MCBs Terminal etc. with necessary connection
Supply, fabrication and installation of 14 SWG CRCA sheet metal made feeder piller with IP protection IP 55 (with enclosure, Single Door), I/C 63 A FP Isolator and 1 no. 24 hr Digital Time Switch and 1 no. 63A 3pole power contactor complete with internal wiring with suitable size of copper wire including 1 no. toggle switch and 2 nos. LED indicator, 4x63A bus bar of suitable size, Outgoing : 32A FP MCB (c curve, 10KA) -4nos, on angle iron frame on wall, incl. earthing attachment and painting as required incl. all interconnection as per direction of EIC. For outdoor light (Make- LK/ Legrand /Siemens)
S&F of 415V 3-phase timer DB (equivalent to 16 Way SPNDB in size) with double door sheet steel enclosure, neutral bar, din rail, with lP-43 protection comprises with 32A FP MCB(C-curve 10kA) and 1 no. 24 hr Digital Time Switch and 1 no. 32A 3pole power contactor complete with internal wiring with suitable size of copper wire including 1 no. toggle switch and 2 nos. LED indicator and earthing attachment as per direction of EIC. (Make- L&T/ Legrand /Havells)
SUB-HEAD 8--SUPPLY OF LIGHT FITTINGS S & F of 10 Watt LED Bulkhead light for indoor as well as out door having following Model / Cat No. ( Make -Philips-WT140W LED7S CW PSU S1 PC/Surya-SLE BLH 10W PLUS/ similar specification of Crompton/Orient Electric/Wipro) with 03 years Warrenty .
Supply of 4 Ft. Single LED light fitting for indoor application, complete with all accessories having following Model / Cat No. ( Make -Philips-TMC 502 1xT-LED 22W/Surya -SUB 118 T8 LED 1X18W/ similar specification of Crompton/Orient Electric/Wipro)
Supply of 4 Ft. Double LED light fitting for indoor application, complete with all accessories having following Model / Cat No.(Make-Philips-TMC 502 2xT-LED 22W/Surya -SUB 218 T8 LED 1X18W/ similar specification of Crompton/Orient Electric/Wipro)
Supply of 4 Ft. 18W-20 Watt LED light (Minimum Lumen Out:- 105 lumen/watt) for indoor application, having following Model / Cat No. (Make-Philips-MAS LED Tube 1200mm 18W 865T8l-2100lm/Surya -SLE TL DS 18 P AL EXT 18W/ similar specification of Crompton/Orient Electric/Wipro) with 03 years warranty
Fixing only Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure. [C-3/20(a)]
Supply of 45/50 Watt LED Street light luminarie complete with all accessories and equipped with IP66 Protection (Make-Philips-BRP331 LED54 CW R5N PC PSU S1 V1/Surya -SLE UL 50W IP66 NGN/ similar specification of Crompton/Orient Electric/Wipro. ) on existing MS Pipe/Mini Pole/Long Pole as per direction of E.I.C. with 5 years warranty certificate.
Supply of 70/72 Watt LED Street light luminarie complete with all accessories and equipped with IP66 Protection (Make-Philips-BRP333 LED84 CW R5C FG PSU S1 V1/Surya -SLE UL 72W IP66 NGN/ similar specification of Crompton/Orient Electric/Wipro) on existing MS Pipe/Mini Pole/Long Pole as per direction of E.I.C with 5 years warranty certificate.
Supply & Fixing of 240V, 90 W LED Street light luminarie complete with all accessories and equipped with IP66 Protection( Make-Philips-BRP333 LED110 CW R5C FG PSU S1 V1/Surya -SLE UL 90W IP66 NGN/ similar specification of Crompton/Orient Electric/Wipro ) on existing MS Pipe/Mini Pole/Long Pole as per direction of E.I.C. with 5 years warranty
Supply of 120 Watt LED Street light luminarie complete with all accessories and equipped with IP66 Protection (Make-Philips-BRP334 LED144 CW R5C FG PSU S1 V1/Surya -SLE UL 120W IP66 NGN/ similar specification of Crompton/Orient Electric/Wipro) on existing MS Pipe/Mini Pole/Long Pole as per direction of E.I.C. with 5 years warranty certificate.
Supply of 100 Watt LED flood light luminarie complete with all accessories and equipped with IP66 Protection (Make-Philips-BVP282 LED120 CW FG SY5WB 100W V1/Surya -SLE FL 100W IP66 LMS NEO N/ similar specification of Crompton/Orient Electric/Wipro) on existing MS Pipe/Mini Pole/Long Pole as per direction of E.I.C. with 5 years warranty certificate.
Supply of 150 Watt LED flood light luminarie complete with all accessories and equipped with IP66 Protection (Make-Philips-BVP283 LED181 CW FG SY5WB 150W V1/Surya -SLE FL 150W IP66 LMS NEO N/ similar specification of Crompton/Orient Electric/Wipro) on existing MS Pipe/Mini Pole/Long Pole as per direction of E.I.C. (with 5 years warranty certificate.
Supply of 50/70 Watt LED flood light luminarie complete with all accessories and equipped with IP66 Protection [MakePhilips-BVP281LED085 CW FG SY5WB 70W V1/Surya -SLE FL 50W IP66 LMS NEO N/ similar specification of Crompton/Orient Electric/Wipro ] on existing MS Pipe/Mini Pole/Long Pole as per direction of E.I.C. with 5 years warranty certificate.
SUB-HEAD 9--FIXING OF FANS. Supply & Fixing Socket type fan regulator (Step type)(Brand:Anchor/Havells/L&T) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: For 23 cm (9") Exhaust fan
Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For 23 cm (9") Exhaust fan
SUB-HEAD 10--SUPPLY OF FANS. Supply of 1200 mm sweep ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS with 2 Year warranty, Safety Wire & S3/P2 Capacitor (Make:Crompton-HS/USHA-STRIKER PWD /Similar specification of Orient )
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC Heavy Duty) 9" ( 230mm ) Speed 1370 RPM
SUB-HEAD 11 -- EARTHING Excavation of soil for installation of Earth Electrode and filling & ramming. For Morrum Soil for 2 set dual earthing.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI pipe for 2 set dual earthing. By TATA - Medium GI Pipe
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc for 2 set dual earthing.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
SUB-HEAD 12--MISCELENEOUS. Dismantling main switch, switch board, existing wiring & unservisable materials incl. Mending good the damaged of building works and submit those materials to the concerned authority by one electrician, one no masson, 1 nos helper as per instruction of EIC.
N.B: i) Payment will be made after availability of fund from concern Department. ii) Payment will be made as per P.W.D norms.
MOON LIGHT (BID ID -6821846)
MODERN ENGINEERING ENTERPRISE (BID ID -6835328)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .