Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.5 LAccepted-AOC H 6 HOUSING UNIT MATHAIYANKUTTAI PO METTUR DAM 636406 | SALEM | TAMIL NADU | 636406 | ₹5.5 L Quoted ₹5.3 L | 1 | Accepted-AOC L1 |
| 2 | 2₹5.6 LRejected-AOC M 36 HOUSING UNIT MATHAIYANKUTTAI PO METTUR DAM 636452 | METTUR DAM | SALEM | TAMIL NADU | 636452 | ₹5.6 L | 2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | MARSSAL ENTERPRISES L2 | R K ENGINEERING CONTRACTOR L1 |
|---|---|---|---|---|---|
| 1.00 | Providing & dismantling scaffolding arrangements above APH (Nearby style-07 expansion joints) and cover the opening above APH with 3.15 mm HR sheet to prevent falling of materials in to APH to ensure safety for the workmen in APH. | 1 | Nos. | 84,000 ₹84,000 | 83,050 ₹83,050 |
| 2.00 | Charges for cutting and removal of heavily eroded flue gas duct plates (Multilayer) from the parent plate, transporting & devoluting scrap to Central Stores/M.T.P.S.I. | 40 | M2 | 1,300 ₹52,000 | 1,200 ₹48,000 |
| 3.00 | Charges for cutting and removal of eroded guard plates over the expansion joint of Style 07 and providing new guard plate of size 3.15 mm HR sheet over the expansion joint after completion of inspection and patch welding works on expansion joints. | 40 | M2 | 1,680 ₹67,200 | 1,550 ₹62,000 |
| 4.00 | Charges for transporting of 6 mm M.S./ Chequered plates from Central Stores/MTPS to Boiler area, cutting into required size, leading, lifting, positioning on the eroded portions of the duct and welding the same. | 40 | M2 | 1,730 ₹69,200 | 1,650 ₹66,000 |
| 5.00 | Charges for removing the existing eroded duct supports and transporting of new pipes / Angles from Central Stores / MTPS-I, cutting into required size leading lifting, positioning and welding. | 80 | Mtr | 270 ₹21,600 | 250 ₹20,000 |
| 6.00 | Renewal of supporting structure of APH inlet and out let duct Hopper area. | 1 | Nos. | 84,600 ₹84,600 | 82,200 ₹82,200 |
| 7.00 | ERW Black steel tubes of size 80 MM NB (3.5”) X 4.85 mm WT (“Heavy” Class) X 6m Long+/-10%,Manufactured to IS 1239 of 1979 part-I, Plain at ends with Material / Manufacturers test certificate Make:TATA/SAIL/JINDAL | 80 | Mtr | 1,400 ₹1.1 L | 1,300 ₹1.0 L |
| 8.00 | Cutting gas | 4 | Set | 4,200 ₹16,800 | 4,000 ₹16,000 |
| 9.00 | Welding Rod | 97 | Kgs | 530 ₹51,410 | 490 ₹47,530 |
| 10.00 | Consumable charges | 1 | LS | 4,600 ₹4,600 | 4,200 ₹4,200 |
Tender Value
Refer Docs
EMD Value
₹5,100
Closing Date
11 Aug 2025, 2:00 pmClosed
Superintending Engineer /Mechanical-I/MTPS-I
Office of the Superintending Engineer / Mechanical -I Mettur Thermal Power Station- I Mettur Dam-636406
MTPS I BM Unit IV AOH 2025 2026 Cutting Patch welding on the eroded portion of the FG duct from ECO outlet to APH inlet renewal of Support Beam both inlet and outlet of APH hoppers and renewal of eroded duct support pipes both A and B sides
2025_EB_589177_1
CE / MTPS-I / SE / M-I / BM /OT. 216 / 2025-26
Open Tender
Power/Energy Projects/Products
20 days
Mettur Thermal Power Station-I / Mettur Dam
As per the Tender Specifications
4 documents required · 4 mandatory
₹0
₹5,100
Yes
27 May 2026
5 Aug 2025
12 Aug 2025
5 Aug 2025
11 Aug 2025
5 Aug 2025
Amount
Providing & dismantling scaffolding arrangements above APH (Nearby style-07 expansion joints) and cover the opening above APH with 3.15 mm HR sheet to prevent falling of materials in to APH to ensure safety for the workmen in APH.
Charges for cutting and removal of heavily eroded flue gas duct plates (Multilayer) from the parent plate, transporting & devoluting scrap to Central Stores/M.T.P.S.I.
Charges for cutting and removal of eroded guard plates over the expansion joint of Style 07 and providing new guard plate of size 3.15 mm HR sheet over the expansion joint after completion of inspection and patch welding works on expansion joints.
Charges for transporting of 6 mm M.S./ Chequered plates from Central Stores/MTPS to Boiler area, cutting into required size, leading, lifting, positioning on the eroded portions of the duct and welding the same.
Charges for removing the existing eroded duct supports and transporting of new pipes / Angles from Central Stores / MTPS-I, cutting into required size leading lifting, positioning and welding.
Renewal of supporting structure of APH inlet and out let duct Hopper area.
ERW Black steel tubes of size 80 MM NB (3.5”) X 4.85 mm WT (“Heavy” Class) X 6m Long+/-10%,Manufactured to IS 1239 of 1979 part-I, Plain at ends with Material / Manufacturers test certificate Make:TATA/SAIL/JINDAL
Cutting gas
Welding Rod
Consumable charges
MARSSAL ENTERPRISES (BID ID -1425046)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid