Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹21.2 L+₹18,620 (0.89%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹22.4 L+₹1.4 L (6.89%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹22.7 L+₹1.7 L (7.99%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹23.1 L+₹2.1 L (9.80%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s VEENUS CONSTRUCTION L6 | M/S M D TRADERS L2 | M/S RAZA ELECTRICAL AND SUPPLIERS L5 | sunrise electrical prop shahid bilal itoo L9 | GUROO ELECTRICALS L7 | PAMPOSH ELECTRICALS AND SUPPLIES L11 | NAZEEM ELECTRICALS SUPPLIERS L8 | M/s NEYAZ AHMAD WANI ANDBROTHERS L12 | D.S ENTERPRISES L4 | GENIUS ELECTRIC WORKS L10 | Reaching Rays Infra Electricals L1 | Bright and Raident Group L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing, commissioning including Loading, Transportation , insurance, Unloading, Carriage and Delivery at Site of 100 kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, redesignated as Level 1 energy efficient, Aluminium wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate. Including return of old DT to divisional stores Anantnag | 1 | No | 1,52,000 ₹1,52,000 Lowest | 1,59,000 ₹1,59,000 | 2,50,000 ₹2,50,000 | 2,45,000 ₹2,45,000 | 1,92,000 ₹1,92,000 | 2,50,000 ₹2,50,000 | 1,65,000 ₹1,65,000 | 3,12,120 ₹3,12,120 | 1,76,000 ₹1,76,000 | 1,82,000 ₹1,82,000 | 1,73,000 ₹1,73,000 | 1,63,000 ₹1,63,000 |
| 2.00 | Supply,installation,testing,commissioning of 11 kV, G.O AB Switch , 3-phase, 3-Pole, 200A | 1 | Set | 12,500 ₹12,500 | 11,300 ₹11,300 | 7,000 ₹7,000 | 9,000 ₹9,000 | 9,700 ₹9,700 | 12,000 ₹12,000 | 9,500 ₹9,500 | 6,500 ₹6,500 Lowest | 10,800 ₹10,800 | 10,000 ₹10,000 | 9,499 ₹9,499 | 9,400 ₹9,400 |
| 3.00 | Supply,installation,testing,commissioning of 11 kV Horn Gap Fuse Set 3-Phase, 3-Pole, 200Amp. | 1 | Set | 4,500 ₹4,500 | 3,500 ₹3,500 | 1,500 ₹1,500 Lowest | 7,000 ₹7,000 | 3,100 ₹3,100 | 5,000 ₹5,000 | 6,500 ₹6,500 | 6,500 ₹6,500 | 2,500 ₹2,500 | 4,000 ₹4,000 | 3,999 ₹3,999 | 3,500 ₹3,500 |
| 4.00 | Supply,installation,testing,commissioning of Gapless Surge Arrestor,9 kV,10 kA, LA with (procelein) housing, Station Type Heavy Type | 1 | Set | 8,000 ₹8,000 | 3,500 ₹3,500 | 4,000 ₹4,000 | 5,000 ₹5,000 | 4,500 ₹4,500 | 5,000 ₹5,000 | 3,000 ₹3,000 | 6,500 ₹6,500 | 2,000 ₹2,000 Lowest | 4,000 ₹4,000 | 3,999 ₹3,999 | 5,600 ₹5,600 |
| 5.00 | Providing and Fixing of G.I.channel Iron ISMC100x50x6mm) with 50X8 mm back clamps without drilling/punching holes in the poles.. | 56 | Kg | 105 ₹5,880 Lowest | 120 ₹6,720 | 140 ₹7,840 | 150 ₹8,400 | 132 ₹7,392 | 150 ₹8,400 | 140 ₹7,840 | 130 ₹7,280 | 138 ₹7,728 | 130 ₹7,280 | 118 ₹6,608 | 118 ₹6,608 |
| 6.00 | Providing and Fixing of GI channel Iron ISMC 75x40x6 mm) with 50X8 mm back clamps without drilling/punching holes in the poles including transformer belt | 144 | Kg | 105 ₹15,120 Lowest | 120 ₹17,280 | 140 ₹20,160 | 150 ₹21,600 | 132 ₹19,008 | 150 ₹21,600 | 135 ₹19,440 | 130 ₹18,720 | 138 ₹19,872 | 130 ₹18,720 | 118 ₹16,992 | 118 ₹16,992 |
| 7.00 | Providing and fixing of Angle Iron 45x45x5 mm 10 ft long duly painted for Transformer Belt | 21 | Kg | 85 ₹1,785 Lowest | 120 ₹2,520 | 140 ₹2,940 | 150 ₹3,150 | 132 ₹2,772 | 150 ₹3,150 | 140 ₹2,940 | 130 ₹2,730 | 138 ₹2,898 | 130 ₹2,730 | 115 ₹2,415 | 90 ₹1,890 |
| 8.00 | Supply, Laying Testing and commissioning of PVC Cable 185 mm sq. of standard make with ISI Insulation. | 44 | m | 350 ₹15,400 | 330 ₹14,520 | 1,500 ₹66,000 | 350 ₹15,400 | 230 ₹10,120 | 500 ₹22,000 | 450 ₹19,800 | 300 ₹13,200 | 351 ₹15,444 | 200 ₹8,800 Lowest | 350 ₹15,400 | 300 ₹13,200 |
| 9.00 | Providing and fixing of Al thimbles of 185 sq mm | 4 | No | 100 ₹400 | 80 ₹320 | 50 ₹200 | 300 ₹1,200 | 26 ₹104 | 190 ₹760 | 80 ₹320 | 250 ₹1,000 | 20 ₹80 Lowest | 50 ₹200 | 80 ₹320 | 80 ₹320 |
| 10.00 | Supplying and installation of sub station earthing by excavation of earth pit of dia 650mm and depth 3000mm, installation of earthing pipe of 40mm nominal bore and 4 mm wall thickness and length 2.5m long as per IS 1239. GI Strip for neutral earthing of size 25mm x 3 mm for connection of Transformer Body, GO Set and Lightning Arrestor as per IS 2629/85, GI Nuts and Bolts, refilled with earth enhancement materials and earth chamber made of brick messonary with RCC Slab cover | 3 | No | 1,200 ₹3,600 | 1,600 ₹4,800 | 1,000 ₹3,000 Lowest | 1,500 ₹4,500 | 2,000 ₹6,000 | 3,000 ₹9,000 | 1,500 ₹4,500 | 7,500 ₹22,500 | 1,000 ₹3,000 Lowest | 2,500 ₹7,500 | 2,000 ₹6,000 | 1,300 ₹3,900 |
Tender Value
₹30.7 L
EMD Value
₹61,480
Closing Date
18 Aug 2025, 4:00 pmClosed
EXECUTIVE ENGINEER ED ANANTNAG
OFFICE OF THE EXECUTIVE ENGINEER ED ANANTNAG
Creation of 100KVA Electric Sub Station for providing Power Supply to Hazelnut Farm Lehanwan.
2025_PDD_282720_1
18/EDA OF 2025-26
Open Tender
Electrical Works
Turn-key
25 days
ANANTNAG
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
EXECUTIVE ENGINEER ED ANANTNAG
₹61,480
19 Aug 2025
29 Jul 2025
19 Aug 2025
29 Jul 2025
18 Aug 2025
29 Jul 2025
29 Jul 2025 - 18 Aug 2025
Amount
Supply, installation, testing, commissioning including Loading, Transportation , insurance, Unloading, Carriage and Delivery at Site of 100 kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, redesignated as Level 1 energy efficient, Aluminium wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate. Including return of old DT to divisional stores Anantnag
Supply,installation,testing,commissioning of 11 kV, G.O AB Switch , 3-phase, 3-Pole, 200A
Supply,installation,testing,commissioning of 11 kV Horn Gap Fuse Set 3-Phase, 3-Pole, 200Amp.
Supply,installation,testing,commissioning of Gapless Surge Arrestor,9 kV,10 kA, LA with (procelein) housing, Station Type Heavy Type
Providing and Fixing of G.I.channel Iron ISMC100x50x6mm) with 50X8 mm back clamps without drilling/punching holes in the poles..
Providing and Fixing of GI channel Iron ISMC 75x40x6 mm) with 50X8 mm back clamps without drilling/punching holes in the poles including transformer belt
Providing and fixing of Angle Iron 45x45x5 mm 10 ft long duly painted for Transformer Belt
Supply, Laying Testing and commissioning of PVC Cable 185 mm sq. of standard make with ISI Insulation.
Providing and fixing of Al thimbles of 185 sq mm
Supplying and installation of sub station earthing by excavation of earth pit of dia 650mm and depth 3000mm, installation of earthing pipe of 40mm nominal bore and 4 mm wall thickness and length 2.5m long as per IS 1239. GI Strip for neutral earthing of size 25mm x 3 mm for connection of Transformer Body, GO Set and Lightning Arrestor as per IS 2629/85, GI Nuts and Bolts, refilled with earth enhancement materials and earth chamber made of brick messonary with RCC Slab cover
Supply,erection, testing, commissioning including Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. Long ST Poles (410, SP-33) with pit excavation, refilling the pit with soil, boulders.
Supply,erection, testing, commissioning including Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation, refilling the pit with soil, boulders.
Providing and fixing of GI Channel Iron V shaped X arms with F top complete and 2 No angle Iron braces with fittings complete (21 Kg each)
SITC of 11 KV Polymeric Composite Disc Insulator 12 KV, min failing load 45KN, lighting impulse 75 KV +ve and 80 KV -ve, creepage distance 320 mm
SITC of 11 KV Polymeric Composite Pin Insulator 12 KV, 5KN, lighting impulse 75 KV +ve and 80 KV -ve, creepage distance 320 mm
LT Shackles with Muki Clamps complete with bolts and fittings
Suspension/Tension Clamp with eye hook
Supplying and fixing of Galvanized Nuts and Bolts of sizes.
Supply and fixing of LT Distribution Box for 100 KVA DTR with 160 Amp MCCB 3-pole 16 KA along with Prodigy Meter for 100 KVA
Supply,Laying,testing,commissioning including Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of 30 sq mm ACSR (WEASEL) conductor including joints with PG clamps of required size.
Supply,Laying,testing,commissioning 50 mm² AB (LT) Cable ( 3x50 + 1 x 16 + 1 x 35 mm²) mm² XLPE (1.1kV, 3+1 C, Al
Providing & fixing of Earthing Complete for Poles by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm
Supply and Painting of each Pole 1 coat red oxide paint and 2 or more coats of aluminium paint so as to obtain even finish including Pole Marking ( 6inch x 6 inch in yellow paint and 1 inch Black Marking)
Providing and laying of Cement bottoming 1:2:4 mix as per REC standards 0.48 cum for 9 mtr poles muffing 20 cm above ground level ,including plaster and curing of concrete.
Providing and laying of Cement bottoming 1:2:4 mix as per REC standards 0.40 cum for 8 mtr poles muffing 20 cm above ground level ,including plaster and curing of concrete.
Providing and fixing of Danger Plates of standard make
Providing and fixing of Anticlimbimg devices with Clamps 2.5 kg Average
M/S M D TRADERS (BID ID -2445745)
Bright and Raident Group (BID ID -2443920)
D.S ENTERPRISES (BID ID -2445332)
M/S RAZA ELECTRICAL AND SUPPLIERS (BID ID -2445038)
M/s VEENUS CONSTRUCTION (BID ID -2444134)
GUROO ELECTRICALS (BID ID -2445296)
NAZEEM ELECTRICALS SUPPLIERS (BID ID -2437801)
sunrise electrical prop shahid bilal itoo (BID ID -2445278)
GENIUS ELECTRIC WORKS (BID ID -2445511)
PAMPOSH ELECTRICALS AND SUPPLIES (BID ID -2444758)
M/s NEYAZ AHMAD WANI ANDBROTHERS (BID ID -2444736)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .