| 1 | L1₹18.3 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹24.4 L+₹6.1 L (33.3%)Rejected-Finance | L2 | Rejected-Finance Not Lowest |
Tender Value
₹22.9 L
EMD Value
₹45,860
Closing Date
17 Jan 2022, 6:00 pmClosed
CWE PUNE
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
86126SPECIAL REPAIR / REPLACEMENT OF OLD VINTAGE MORTUARY AC PLANT AT AFMC PUNE.
2021_MES_496655_1
86126SPLREPOFMORTUARYATGECPUNE
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
GE Central Pune
As per Tender
9 documents required · 9 mandatory
₹500
GE Central Pune
₹45,860
Yes
15 Feb 2022
22 Dec 2021
19 Jan 2022
22 Dec 2021
17 Jan 2022
5 Jan 2022
Amount
Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified and as directed.
M&L for 40 mm thick cement concrete type B-1, 1:2:4 (20 mm graded stone aggregate) as in floor, complete all as specified and as directed.
M&L for 20 mm thick screed bed or bedding layer in cement mortar (1:6), for laying floor finish etc complete all as specified and as directed.
M&L for rendering 10 mm thick on brick work of concrete surfaces in CM (1:3) as in backing coat to receive wall tiles or risers of steps, columns, dado / skirting, pillars etc complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar fixing over cement plaster and jointed complete all as specified and as directed.
M&L for 50 mm thick average PCC (1:2:4) TYPE B1, (Using 20 mm graded stone aggregate) mixed with integral water proofing compound wherever required as directed and laid on RCC slab as base layer for roof treatment including roughing the top surface complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 mixed with integral water proofing compound and finished fair and even without using extra cement. Note :- WPC shall be measured and paid seperately.
Supply only integral water proofing compound complete all as specified and as directed.
M & L for Water proofing treatment to RCC roof slab, walls, chhajjas etc, shall be carried out as specified below and as directed by Engineer-in-Charge. (a) M & L for 10 mm thick plaster screed bed layer in CM 1:3 on concrete surfaces with water proofing compound. (b) Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bituminous primer @ 0.70 Kg/sqm of area complete all as specified. (c) Laying 3 mm thick APP polymer modified approved membrane, non woven, polyester, weighing not less than 3.6 Kg /sqm with laps & overlaps as specified & all joints and in direction should be covered with CM 1:3 mixed with SBR latex 200 ml/bag of cement sealed and applied complete by torch application method all as specified & directed and cured well before laying the membrane.The membrane shall be taken up to height of minimum 300 mm through a concrete fillet of 75 mm / 75 mm & shall be inserted in side a grove cut in the parapet and fixed. if the height of parapet is 300 mm or less, membrane shall be taken till top of the parapet and finished after covering the top surface of the parapet, for RCC inverted beam, the whole beam shall be covered with membrane irrespective of the depth, in the case of roof projection, the membrane shall be taken up to the roof edge and sealed by torch application (d) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/sqm on the top of membrane surfaces complete all as specified & as directed and Carrying out test by flooding water for 24 hrs for leakage & seepages and rectifying the same to the entire satisfaction of GE. Note:- water proofing compound will be measured and paid separitly.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm complete all as specified and as directed.
S&F second class hard wood plain, solid, straight chawkats and frames, wrought, framed rabated on the solid, rounded or chamfered, put together with glue pinned at joints etc complete all as specified and as directed.
S&F 35 mm thick flush shutters, solid core constructions with block board core and plywood face panels, commercial type on sides and fixed to chowkats complete all as specified and as directed.
S&F stainless steel butt hinges 100 mm size medium weight and fixed complete all as specified and as directed.
S&F aluminium alloy, anodised, sliding door bolt 250 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed
S&F extruded aluminium alloy handles, fabricated type, anodised 150 mm size, ISI marked. complete all as specified and as directed.
M&L for preparation new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for preparation of old surfaces of wall including cornices, pillasters by brooming down with steel wire brushing scrapping down smoke dust, moulds, moss and efflorescent salts and removing oily and greasy spots etc complete all as specified and as directed.
M&L for preparation of old surfaces of ceiling by brooming down with steel wire brushing scrapping down smoke dust, moulds, moss and efflorescent salts and removing oily and greasy spots etc complete all as specified and as directed.
M&L for applying one coats of cement based paint on old surfaces of walls complete all as specified and as directed.
M&L for applying one coat of white wash on old surfaces of ceiling complete all as specified and as directed.
M&L for applying one coat of white wash on old surfaces of walls complete all as specified and as directed.
Dismantling and taking down unserviceable mortuary AC plant complete with all accessories and depositing in the MES store as directed.
Supply, installation, testing and commisioning of pre fabricated mortuary chamber for 4 bodies with 80 mm thick PUF SS panels and cooling unit maintain temperature between +2 to +6 degree C. conforming to model No - BMC406SS of make : bluestar or equivalent in other approved makes.
Supply, installation, testing and commisioning of Walk in cold room size of walk in cooler-760 cm x 545 cm x 225 cm and comprising of the followings :-
Thickness of insulation 60 mm, PPGI on outside / PPGI on inside Pre-Fab modular PUF panels.
Type of insulation for floor-60 mm Puff slabs.
Door size : PUF-flush in type swing dooe with 34"x78" clear opening with accessories : Anti-condensation door heater, pad lock system, posi seal closure, human safty relese with knob 04 nos.
Max ambient condition : 40 degree C.
Product : dead bodies.
Product incoming temp : 20 to 25 degree C.
Temp required inside the room : 2 to 8 degree.
Door opening per day : 3 to 4 times.
Max duration of each door opening : 1 min.
Refrigeration unit model : Evaparator unit & condensor model No : RUAH-04014 CS#2 Nos, split type air cooled, 415/3/50 HZ refrigeration cap 40000 BTU/Hr x 2 nos @ 4 degree C room temp. split type air cooled, refrigerent : R404 ECO FRIENDLY REFRIGERANT , make blue star or equivalent.
Digital temp indicator cum controller and internal lighting complete as per manufacturer design.
Copper tubing suitable size with insulation from indoor to out door unit drain pipe.
PVC copper cable suitable size from indoor to outdoor cable and from nearest connections point.
Note :- (a) Necessarry opening on bricks / stone masanory wall and finishing duly matching with the surrounding. cost of the same is deemed to be included in the quoted rate.(b) The out door unit shall be fixed on wall with suitable brackets and the rate same is deemed to be included in the quoted rate.
BRITE INDUSTRIES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .