Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-AOC | ₹2.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹2.9 L+₹16,601 (6.13%)Rejected-AOC | ₹2.9 L+₹16,601 (6.13%) | L2 | Rejected-AOC L2 |
| 3 | L3₹2.9 L+₹17,695 (6.53%)Rejected-AOC | ₹2.9 L+₹17,695 (6.53%) | L3 | Rejected-AOC L3 |
| 4 | L4₹3.0 L+₹31,660 (11.7%)Rejected-AOC | ₹3.0 L+₹31,660 (11.7%) | L4 | Rejected-AOC L4 |
| 5 | L5₹3.1 L+₹40,635 (15.0%)Rejected-AOC | ₹3.1 L+₹40,635 (15.0%) | L5 | Rejected-AOC L5 |
Tender Value
₹5.4 L
EMD Value
₹10,796
Closing Date
21 Nov 2022, 9:30 amClosed
Executive Engineer
EE, EandM, Division, APWD, Prothrapur, Port Blair
Repair and Renovation of QMS Store at IRBn HQ Port Mout SW Providing IEI
2022_APWD_7839_1
NIT No 67/EE/EandM/22-23
Open Tender
Electrical Works
Item Rate
45 days
South Andaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹10,796
12 Dec 2022
28 Oct 2022
21 Nov 2022
28 Oct 2022
21 Nov 2022
3 Nov 2022
29 Oct 2022 - 2 Nov 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. a) Group-C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b) 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
c) 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required a) 5/6 amps switch
b) 3 pin 5/6 A socket outlet
Supplying and fixing Plastic Board of 3.5"x6" on surface including providing and fixing 5 pin 5/6 (2&3 pin) amps socket outlet and 5/6 A, P.T switch, connection, painting, etc as required.
Supplying and fixing Plastic Board of 3.5"x8" on surface including providing and fixing 6 pin & 6/16 amps socket outlet and 16 A, P.T switch connection, painting, etc as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way (4 + 24), Double Door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single Pole
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 63A
Supplying and fixing of surface mounted LED Industrial Box Type Fitting with 20 Watt LED T-8 PC Tube Lamp Similar to C&S Model No. CRUX/1X20W ordering code LTIC00120WLED/WD or its equivalent etc., as required.
Supplying and fixing Bakelite batten/ angle holder including connection etc. as required.
Supplying of 12Watt LED Lamp in the existing Batten Holder similar to C&S CHANDRA/12W/W/B22, Cat No. LTHPLEDLAMP12WB22 BULB or its equivalent etc., as required.
Supplying of BLDC Energy efficient AC Ceiling Fan 1200mm Sweep (Colour: Opal White, Brown) without Remote similar to crompton ENERGION Riviera 5 Star ISI Marked with out regulator or its equivalent etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying of 300mm sweep, 900 RPM Heavy duty metallic Exhaust fan equivalent to Havells Model : Turbo Force SP or its equivalent etc., as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. a) Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes
Providing earthing with safe earthing electrode of galvanization 80 to 100 microns, length 2 mtr, outer dia 50 mm, inner dia 19 mm and inner space be filled with crystalline conductive mixture including filling -up with electrolite (Back fill compound) as required for safe earth electrode and providing masonary enclosure with cover plate having locking arrangement etc. as required. (Ashlok)
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
M/s G K Construction
NAVJEEVAN ENTERPRISES
DILIP RAJ
M/s Sai Electrical Works
POWER ENGINEERING CO
DAYAL HALDER
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .