Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹9.2 L+₹67,126 (7.89%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹10.0 L+₹1.5 L (17.5%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹13.7 L+₹5.2 L (60.8%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L4 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
24 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE South Delhi Cantt-10
GE South Delhi Cantt-10
REPAIR/REPLACEMENT OF E/M NATURE OF WORKS OF OTM ACCN AND MANEKSHAW CENTRE UNDER AGE E/M OF GE (SOUTH) DELHI CANTT-10
2023_MES_605769_1
GE/DS-46/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹40,000
Yes
13 Sept 2023
26 Jun 2023
26 Jul 2023
26 Jun 2023
24 Jul 2023
10 Jul 2023
Amount
Attending complaints in between 0830 hrs to 1630 hrs for checking the existing electrical items for continuous electric supply including carrying out minor repair etc as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable of suitable size at site, insulation tape roll etc. Attending minor repair such as testing, electric connections, fittings, nuts, bolts and screws etc to ceiling fan, exhaust fan at its initial position (without taking down) etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existing electrical system of main building/block for uninterrupted electric supply including carrying out minor repairs etc. required to make the system in order/functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and as directed.
All as per Srl item No. 1 above, but attending complaints in between 1630hrs to 2300hrs.
Notes for Srl item Nos.1 & 2 :- 1. The site for attending complaints are OTM Accn and Manekshaw Centre at Manekshaw Centre Contractor shall provide adequate Tradesmen (Electrician) alongwith Helper to attend the complaints all the above areas in all working days including holidays and sundays if required as per the direction of Engr-in-Charge. 2. The Manekshaw Centre is a prestigeious building have ceiling height varying from 4.00 mtr to 8.50 mtr. It is therefore necessary movable ledder/scaffolding upto 4 mtr height arrangment are be made by the contractor to attend the complaint which should be readly available and contractor quoted rate are inclusive for the same. However where it is inescapable necessary 4 leg scaffolding shall also be provided by the contractor and the same shall be measured and paid under Srl item 92 of this schedule. 3. Contractor shall ensure the security passes for his staff, to be obtained from concern authority for attending complaints. 4. The contractor will ensure that the team of electricians with necessary tools bag, shall always remain present at complaint cell to attend the complaints. 5. The complainted are to be attended immediately i.e. within 30 minutes. If the complaint not attended within 30 minutes necessary recovery (panelty) per complaint for not attending the complaint within stipulated time shall be made from the contractors claim as under :- (a) Not attending the complaint 30 minutes to 2 Hrs - Rs.240/complaint. (b) Not attending the complaint beyond 2 Hrs & upto 4 Hrs - Rs.480/complaint. (c) Not attending the complaint beyond 4 Hrs - Rs.2400/complaint. 6. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost. 7. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill. 8.The above tradesmen shall not be utilized for the items entered here-in-after as taking down, S&F, M&L, S&F in repairs M&L in repairs etc. and the rate quoted by tenderer are deemed to be included for the same. 9. The material like PVC copper cable 1.50/2.50 Sqm upto 3.00 Mtr, fuse, screws, insulation tape, copper thimbles, glands etc. requried to make the electricity functional are to be arranged by the contractor and the quoted rates are deemed to be included for the same. 10. The rates quoted by the tenderers are deemed to be included for necessary 4 legs steel/bamboo scaffolding and safety precuatisions upto 4 mtr height. Beyond 4 mtr height scaffolding shall be measured and paid seperately. 11. The complaints per day may vary from NIL complaint to 25 complaint per day appx. The manpower may be sitting idle when no complaint are received and no claim shall be entertained while sitting idle or not getting complaint. The quoted rate by the contractor are deemed to be included for this provision.
Taking down burnt/unserviceable copper/aluminium point wiring (light, fan, socket or pwer) complete including fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed.
M&L for point wiring with stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through existing concealed PVC/ new PVC Conduit concealed and including replacement of modular sunken pressed steel terminal boxes 2mm thick of required size and modular white cover plate with all accessories including 1.5 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete and making good to disturbed surface of walls including necessary touch up with adjoining surface of disturbed area i.e with OBD/colour work/white wash as existing finishes complete all as specified and as directed. Note :- In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes.
All as per Srl item No.4 above, but for one 3 pin 5 Amps socket outlet point controlled by one No one way modular switch and modular socket on independent board.
All as per Srl item No.4 above, but for one 3 pin 5 Amps socket outlet point controlled by one No one way modular switch and modular socket on same board.
All as per Srl item No.4 above, but for 16 Amps for modular socket point with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 16 Amps modular switch/socket outlet point on independent board.
All as per Srl item No.4 above, but for one AC point controlled using cable of 4 Sq mm for phase and neutral and 4 sqmm for earthing.
S&F Switch modular type, 1Module, 6 Amps one way as per sample complete all as specified and as directed.
S&F Socket outlet modular type 2M, 2/3 pin, 6 Amp as per sample complete all as specified and as directed.
S&F Switch modular type 1M, 16 Amp as per sample complete all as specified and as directed.
S&F Socket Outlet modular type 2M combined shuttered, 5 pin 6/16 Amp as per sample complete all as specified and as directed.
S&F electric bell ding dong AC, 230 volts single phase complete all as specified and as directed.
S&F Bell push modular type 1M 5/6 Amp complete all as specified and as directed.
S&F Electronic fan regulator, modular type 2M, 4 steps, as per sample complete all as specified and as directed.
S&F Modular box with MCB 20 Amp complete with metal box and 3 Pin top plug as per sample complete all as specified and as directed. Note : Rates are inclusive of cutting / chases for mounting modular metal box concealed in wall and making good to disturbed surfaces with OBD / Colour wash / white wash and wall putty where ever required complete all as specified and as directed.
S&F in repairs Switch modular type, 1Module, 6 Amps one way as per sample complete all as specified and as directed.
S&F in repairs Switch modular type 1M 6 Amp 2-way as per sample complete all as specified and as directed.
S&F in repairs Socket outlet modular type 2M, 2/3 pin, 6 Amp as per sample complete all as specified and as directed.
S&F in repairs Switch modular type 1M, 16 Amp as per sample complete all as specified and as directed.
S&F in repairs Socket Outlet modular type 2M combined shuttered, 5 pin 6/16 Amp as per sample complete all as specified and as directed.
S&F in repairs Electronic fan regulator, modular type 2M, 4 steps, as per sample complete all as specified and as directed.
S&F in repairs electric bell ding dong AC, 230 volts single phase complete all as specified and as directed.
S&F in repairs Bell push modular type 1M 5/6 Amp as per sample complete all as specified and as directed.
M&L for point wiring with stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable suitable concealed PVC/MS conduit and including replacment of unsv pressed steel terminal boxes of required size and factory painted with stove enameled black paint with top cover 3mm thick plastic/laminated sheet of required colour with screwed and cup washer with all accessories including 1.5 Sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sqmm for phase and neutral and 1.5 Sqmm for earthing) complete all as specified and as directed. One light/fan/bell point/security light conrrolled by one way switch. Note:- The rate is inclusive cutting/chasing and making good distrubed surface with CM 1:3 adn same surface finishes with the adjoining surface of distribed area with ODB/colour wash/white wash completed.
All as per item No.25 above, but for one 3 pin socket outlet, 5/6 Amps, independent, with cable 1.5 Sqmm size suitable concealed PVC/MS conduit complete all as specified and as directed.
All as per item No.25 above, but for 5 Amp socket outlet on same board complete all as specified and as directed.
All as per item No.25 above, but for one socket outlet 15 Amps on independent board with cable 2.5 Sqmm size for phase and neutral and 2.5 Sqmm for earthing with through existing concealed PVC/MS conduit complete all as specified and as directed.
S&F switch piano flush type 5/6 Amps SP one way complete all as specified and as directed.
S&F socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose as per sample complete all as specified and as directed.
S&F switch piano flush type 15/16 Amps SP one way as per sample complete all as specified and as directed.
S&F universal socket outlet 2-in1 (multipurpose) 5 pin 6/16 Amps flush mounted type as per sample complete all as specified and as directed.
S&F 0-4 step type electronic regulator for ceiling fan 1200/1400 sweep, 240 V as per sample complete all as specified and as directed.
S&F in repairs switch piano flush type 5/6 Amps SP one way complete all as specified and as directed.
S&F in repairs socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose as per sample complete all as specified and as directed.
S&F in repairs switch piano flush type 15/16 Amps SP one way as per sample complete all as specified and as directed.
S&F in repairs universal socket outlet 2-in1 (multipurpose) 5 pin 6/16 Amps flush mounted type as per sample complete all as specified and as directed.
S&F in repairs 0-4 step type electronic regulator for ceiling fan 1200/1400 sweep, 240 V as per sample complete all as specified and as directed.
S&F in repairs decorative wall light mounting suitable for LED lamp upto 15 Watt complete all as specified and as directed.
S&F in repairs ceiling rose surface bakelite 65x25 mm two to three terminals complete all as specified and as directed.
S&F in repairs lamp holder bakelite insulated body with back plate suitable for batten fitting complete all as specified and as directed.
S&F in repairs wall mounted LED integrated batten T-5 20 Watt - 4ft white 6500K, indoor decorative PVC extruded T-5 LED batten - integrated type as per sample complete all as specified and as directed.
S&F in repairs wall mounted LED integrated batten T-5 10 Watt - 2ft white 6500K, indoor decorative PVC extruded T-5 LED batten - integrated type as per sample complete all as specified and as directed.
S&F in repairs surface/recess mounting round/square shape LED down lighter 20 Watt any type complete with including new flexible wire as requried on site in repairs of old unsv existing ceiling light fitting complete all as specified and as directed.
S&F in repairs LED 10 Watt white bulk head in engineering plastic housing with clear prismatic including required LED bulb and all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete all as specified and as directed.
S&F in repairs submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 6 Sqmm in 2 runs and 6 Sqmm one run for earth drawing through existing PVC concealed conduit complete all as specified and as directed.
S&F in repairs submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 4 Sqmm in 2 runs and 4 Sqmm one run for earth drawing through existing PVC concealed conduit complete all as specified and as directed.
S&F in repairs submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 2.5 Sqmm in 2 runs and 2.5 Sqmm one run for earth drawing through existing PVC concealed conduit complete all as specified and as directed. Notes for Srl item No 46 to 48:- (a) Two runs of main cable and one run of earth cable all together shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
S&F in repairs MCCB 63 Amps 4 pole 415 volts fixed type with breaking capacity 10 kA 'B' curve 415 Volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc as per sample complete all as specified and as directed.
S&F in repairs MCCB 100 Amps 4 pole 415 volts fixed type with breaking capacity 10 kA 'B' curve 415 Volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc as per sample complete all as specified and as directed.
S&F in repairs MCCB 125 Amps 4 pole 415 volts fixed type with breaking capacity 16 kA 415 Volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc as per sample complete all as specified and as directed.
S&F in repairs MCCB 160 Amps 4 pole 415 volts fixed type with breaking capacity 16 kA 415 Volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc as per sample complete all as specified and as directed.
S&F in repairs MCCB 250 Amps 4 pole 415 volts fixed type with breaking capacity 36 kA 415 Volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc as per sample complete all as specified and as directed.
S&F in repairs MCB SP 10 to 40 Amps 240 Volts, 10 KA, `B' curve, all as per site requirement and as directed by Engr-in-Charge.
S&F in repairs MCB SPN 63 Amps, 240 Volts, 10 KA, `B' curve, all as per site requirement and complete all as specified and as directed.
S&F in repairs MCB TPN 63 Amps 415 volts, 'B' Series 10 KA as per site requirement and complete all as specified and as directed.
S&F in repairs PVC insulated FRLS single core with stranded copper cable of size 1.5 Sqmm single core for any type of wiring as per site requirement and complete all as specified and as directed.
S&F in repairs PVC insulated FRLS single core with stranded copper cable of size 2.5 Sqmm single core for any type of wiring as per site requirement and complete all as specified and as directed.
S&F in repairs PVC insulated FRLS single core with stranded copper cable of size 4 Sqmm single core for any type of wiring as per site requirement in Red/Blue/Yellow, Black & Green colour complete all as specified and as directed.
S&F in repairs PVC insulated FRLS single core with stranded copper cable of size 6 Sqmm single core for any type of wiring as per site requirement and in Red/Blue/Yellow, Black & Green colour complete all as specified and as directed.
S&F in repairs Audio cable including all connection as per sample complete all as specified and as directed.
S&F in repairs video cable including all connection as per sample complete all as specified and as directed.
S&F in repairs HDMI cable including all connection as per sample complete all as specified and as directed.
S&F in repairs cordless mike including charging set as per sample complete all as specified and as directed.
Taking down old unserviceable ceiling fan/exhaust fan dismantling of blades, transportation to work shop and carrying out rewinding, transportation to site, reinstallation and testing complete all as specified and as directed. Note : Rewinding will be measured and paid separately under this Schedule.
M&L for rewinding ceiling fan 1200/1400 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush, ball bearing where ever required complete all as specified and as directed. Note : Gun metal bush, clamp, shaft, capacitor, bearing will be measured under of this item only.
All as per Srl item No.66 above, but exhaust fan 230/300/450 mm sweep as per sample.
S&F in repairs MCB DB SPN 8 Way double door type, (IP 43 Protection) flush mounting as per sample complete all as specified and as directed.
S&F in repairs LED Building security light fitting 40W including GI 25mm bracket in repairs of old unsv existing security light fitting any type complete all as specified and as directed.
S&F in repairs LED Bulb 12 Watt B-22 Cap, AC 230V, 50 Hz, suitable for Batten Holder/Bulk head/SK light fittings as per sample complete all as specified and as directed.
S&F in repairs of distribution board V-TPN 4 way for fixing MCCB 125 Amps as incommer and MCBs as out goings with metal door and IP 43 Protections and connecting complete all as specified and as directed.
M&L in replacement earthing complete with GI earth plate electrode 600 x 600 x 6mm thick burried directly in ground in ground (earth pit plate kess than 2.5 mtrs below ground level) with top edge of the plate not less than 1.5 mtrs deep below normal ground level, connected to galvanised earth wire 4mm by means of bolts, nuts check nuts to earth test point including necessary PCC 1:2:4 type B-1 pit, cover frame, GI pipe 15mm dia light grade with funnel and locking arrangement complete all as specified and as directed.
S&F in repairs earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicate dsituation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and as directed.
M&L in replacement earthing complete with GI earth plate electrode 600 x 600 x 6mm thick burried directly in ground in ground (earth pit plate kess than 2.5 mtrs below ground level) with top edge of the plate not less than 1.5 mtrs deep below normal ground level, connected to galvanised earth iron strip 32x6mm by means of bolts, nuts check nuts to earth test point including necessary PCC 1:2:4 type B-1 pit, cover frame, GI pipe 15mm dia light grade with funnel and locking arrangement complete all as specified and as directed.
S&F in repairs earth continuity conductor or main earthing lead fixed to roof wall other indicate situation for loop earthing etc. as required 25x4 mm dia galvanised iron strip as per site requirement complete all as specified and as directed. Note :- Staircase arrangement for fixing of earth continuity upto to second floor shall be made by the contractor without any cost.
S&F in repairs LED Bollard light fitting luminaires of 8/9 Watt in round Shape of 3000K with IP 65 & complete all accessories including necessary connection of suitable size wire as per sample complete all as specified and as directed.
S&F in repairs track mounting light including all connection as per sample complete all as specified and as directed.
S&F in repairs water tight fitting (water Proof) 9W outdoor as per sample complete all as specified and as directed.
S&F in repairs 120W Flood light fitting luminaires of complete all accessories including necessary connection of suitable size wire as per sample complete all as specified and as directed.
S&F in repairs 120W LED Highway light fitting luminaires of complete all accessories including necessary connection of suitable size wire as per sample complete all as specified and as directed.
S&F in repairs LED based mirror light fitting 22 Watt IP 20 6500K as per sample complete all as specified and as directed.
S&F in repairs 8/9 W LED bush/Spike luminaire having graphite grey as per sample complete all as specified and as directed.
S&F in repairs recessed/surface mounting 36 watt 2' x 2' flat LED panel fitting with soft light and glare free symetrical ilIumination suitable for RCC/POP ceiling supplied with wedge bracket to fix in existing ceiling in repairs of existing old unsv CFL fitting any type from ceiling of common areas and making good disturbed surface/POP ceiling to match and getting electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and as directed.
S&F in repairs 36W LED 1'x4' light recess/surface mounted with LED luminaires made in CRCA sheet metal with fliexble wire complete all as specified and as directed.
S&F in repairs 16/18W LED 1'x1' light recess/surface mounted with LED luminaires made in CRCA sheet metal with fliexble complete all as specified and as directed.
S&F in repairs Flexible copper 3 Core, 4.0 Sqmm twin core complete all as specified and as directed.
S&F in repairs rigid PVC conduit 20mm dia including accessories tees, bends, reducer, cooption, riddles etc complete all as specified and as directed.
S&F in repairs casing caping complete all as specified and as directed.
M&L for providing, cement concrete 1:3:6, type C-2, using 40 mm graded crushed stone aggregates as in foundations, filling and mass concrete for bases of street light including necessary formwork and demolition of existing bases etc. complete all as specified and directed.
Hiring and providing (aluminium/steel) scaffolding with suitable size to attend the complaints where the room it is more than 4.00 mtr complete all as specified and as directed. Notes :- 1. The rate quoted by the tenderer are deemed to be included for hiring, transporting (both side), assembling & dismantling of scaffolding after attending the complaint. 2. The complaint shall be measured and paid seperately under Srl item No. 1 & 2 of this schedule. 3. This item shall applicable only Srl item No.1 & 2 of this schedule.
M&L for comprehensive maintenance and overhauling quarterly (every four months commencing from actual date of commencment of work) of scissor lift platform mounted of size 1500 x 1000 mm capacity 250 Kg stage height 1200 mm with hydrulic pump, motor suitable for to take a wheel chaired person alongwith one attendent installed in Zorawar Auditorium of Manekshaw Centre by performing following task complete all as specified and as directed:- (a) Inspection of brakes, Drive Control. (b) Cleaning of contraol panel. (c) Inspection of control Panel. (d) Electrial Panel. (e) Insepction of safety indication light. (f) Insepction of platform. Note :- 1. Each comprehensive maintenance shall be measured and paid as one Job. 2. Proper date wise record of comprehensive maintenance shall be maintaind duly signed by Contractor and Engr-in-Charge.
Dismantling/disconnection of curtain motor 3 phase, 415 volt, 1.5/2 HP from plateform on roof height complete over hauling/servicing of electricmotor for front/middle/rear curtain including replacement of bearing/brush and unserviceable SWR rope of suitable size and greasing of pullies/gears and refixing after repair the same location in auditorium complete all as specified and as directed.
S&F in repairs pressure pipe suitable for existing scissor lift (any capacity and size) matched with system/machine fitted in Manekshaw centre complete all as specified and as directed.
Supply only compressor oil suitablefor existingscissor lift/curtain motor of any capacity & size matched with system/machine fitted in Manekshaw Centre complete all as specified and as directed.
S&F in repairs thermostat 9/11" (ISI Marked) for 25 Litres capacity Geyser as per sample complete all as specified and as directed.
S&F in repairs MS fastner bolt 8 mm dia and upto 150mm long for fixing Geyser/Exhaust Fan with nuts and washers complete all as specified and as directed.
S&F in repairs heating element of 1.5 KW including rubber washers (ISI marked) etc as per site requirement complete all as specified and as directed.
S&F in repairs storage tank made out of SS Steel sheet of appropriate thickness and confirming to IS 208 (1974) or as per sample for 25 litre capacity geysers with collar, duly tested at required pressure complete all as specified and as directed.
S&F in repairs safety plug and nut for high pressure release as per sample complete all as specified and as directed.
S&F in repairs non return valves 15mm dia made up of brass as per sample complete all as specified and as directed.
S&F in repairs ceiling fan capacitor of 2.5 mfd complete all as specified and as directed.
S&F in repairs Down rod of 1.5 feet height fabricated out of MS pipe 12mm dia heavy duty, duly painted with one coat of white synthetic enamel paint complete all as specified and as directed.
S&F in repairs Canopy of Ceiling fans of 1200/1400mm swipe heavy duty complete all as specified and as directed.
S&F in repairs blade (set of 3 blades) of Ceiling fans 1200/1400mm swipe heavy duty as per sample complete all as specified and as directed.
S&F in repairs blade of exhaust/fresh air fans of 230/300 mm swipe heavy duty as per sample complete all as specified and as directed.
S&F in repairs Exhaust fan MS Louvers upto 450 mm Size, as per sample up to fourth floor complete all as specified and as directed. Note:-Staircase arrangement for fixing of louvers up to fourth floor shall be arranged by the contractor without any extra cost.
Descalling of geyser 25/35 ltrs capacity of any make, opening up complete for inspection descalling by chemical treatment of internal tank, themrostate pipe, base plate assembly including replacement of gaskets testing and refixing in position including making electrical and water connection complete all as specified and as directed.
S&F in repairs PVC Pipe brass nipple 15 mm x 600 mm for Hot & Cold water with brass nuts and washers stainless steel at both ends of length not exc. 60 cms for connection of stainless steel as per sample complete all as specified and as directed.
S&F in repairs indicating lamp round / flat type (Red & Green) 230 volts suitable for Geyser as per sample complete all as specified and as directed.
S&F in repairs insulating material (Glass wool) for 25/35 litre capacity Geysers as per sample complete all as specified and as directed.
S&F in repairs base plate geyser syphon assembly set complete with inlet, outlet and thermostat, complete including rubber gasket as per sample for geyser of 25 litres cap as per sample complete all as specified and as directed.
S&F in repairs acrylic glow sign board with LED light of size 10x7 inch including all connection as per sample complete all as specified and as directed.
Supply and laying cable XLPE insulated screened PVC bedded, galvanised steel strip armoured ,electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 16 sqmm, 4 core including taking out old u/s cable complete all as specified and as directed.
Supply and laying cable XLPE insulated screened PVC bedded, galvanised steel strip armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 25 sqmm, 3.5 core including taking out of u/s cable complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip armoured, electric power cable (heavy duty ) 1100 volt grade with stranded aluminium conductor of size 95sqmm, 3.5 core on wall and trenches including taking out of old u/s cable complete all as specified and as directed.
M&L for excavation of trench not exceeding 1.5 mtr wide and not exc 1.5 mtr in depth for laying cable etc. and getting out in soft/loose soil complete all as specified and as directed..
M&L for sand filling under floors or in foundations including watering consolidation complete all as specified and as directed.
Supply and laying in replacement bricks common burnt clay building sub class 'B' designation 75 complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exe 25 cm complete all as specified and as directed.
Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
Supplying and laying including taking out G.I. tubing light grade for encasing lt cables for mechanical protection , laid under plinth/ floors/ roads/ paths/ culverts or fixed on walls or concealed in walls or along the steel poles incl bends/clamps and all accessories size of 50 mm bore complete all as specified and as directed.
Note :- The contract sum shall be after deducting the amount of credit shown in Sch of Credit of this tender
M/S Malik Construction Corporation
verma enterprises
Chaudhary Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .