Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC 161 VPO RAJLU GARHI GANAUR 131101 | SONIPAT | HARYANA | 131101 | ₹1.3 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.4 Cr+₹10.9 L (8.38%)Rejected-AOC VPO KHARKHARI TEHSIL LOHARU DISTRICT BHIWANI HR | BHIWANI | HARYANA | 127021 | ₹1.4 Cr+₹10.9 L (8.38%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹1.7 Cr+₹38.2 L (29.3%)Rejected-AOC VPO BERLA TEHSIL AND DISTT CHARKHI DADRI HARYANA | CHARKI DADRI | HARYANA | 127022 | ₹1.7 Cr+₹38.2 L (29.3%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹1.6 Cr+₹34.4 L (26.4%)Rejected-AOC | ₹1.6 Cr+₹34.4 L (26.4%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹1.9 Cr+₹55.9 L (42.9%)Rejected-AOC | ₹1.9 Cr+₹55.9 L (42.9%) | L5 | Rejected-AOC Rejected |
Tender Value
₹1.2 Cr
EMD Value
₹2.5 L
Closing Date
23 Sept 2021, 5:00 pmClosed
EE PHED No.1 Rohtak
Jhajjar Road Rohtak
Dhamar Augmentation of water supply scheme FHTC and laying of pipe line renovation of existing Structures of water works in village Construction of 1 No S S Tank, 1 No RCC Clear water Tank Boundary wall Repair of structures at water works laying o
2021_HRY_188402_1
DNIT Approved vide SE Endst No.2402 dt. 03.09.2021
Open Tender
Civil Works
Works
450 days
VPO Dhamar
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
₹2.5 L
Yes
17 Nov 2021
16 Sept 2021
24 Sept 2021
16 Sept 2021
23 Sept 2021
16 Sept 2021
Amount
WATER TREATMENT PLANT (WTP) Desinging , Testing , Commissioning of 0.50 MLD capacity Water Treatment Plant including inlet channel Alum dozing, Flash mixing, Clari floculator, filter box, over head Reservoir for back wash, waste water tank including all civil work pumping machinery and electric cabling, control panel, entire piping network of suitable size laying of DI pipes from raw water pump o inlet Box of WTP, WTP to CWT & Suction well for CW including , DI specials, suitable size sluice valves Hodies manhole covers, air scour equipment, chemical house including chlorination equipment and arrangement of flow measurement and sand bed with automation complete in all respects as per NIT (Sluice valve of make IVCAWAG )
Pumping Machinery Raw water Pump Seta Supply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame. A) For Raw water at water works 600 LPM with 12Mtr Head & 5 BHP For Raw water
Panel Board for Motors Supply, erection, testing and commissioning of wall mounted electrical LT panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900 mm and 400mm deep having following accessories :- A) At water works) For Raw water pump set 600 LPM x 12 M. Head 1 Nos. (One for Two Pump set) at water works A) Main switch 100 Amp 1 No. (L&T siemens, ABB). b) Volt Meter 100 X 100mm range of range 0 to 500 Volt = 1 No. (AE/KAPPA/L&T) c) Amp Meter 100 X 100mm range of range 0 to 100 Volt = 2 No. (AE/KAPPA/L&T) d) CT 100/3Nos. (AE/KAPPA/L&T) e) VSS & ASS 1 No. each No. of approved make/minilac f) SSP 4 No. of approved make/minilac g) Motor starter star delta 1 No. for 600 LPM x 12 M Head Motor (L&T, Siemens, ABB) h) Capacitor KVAR as per site requirement i ) Indicating Lamp = One Set j) Change over Switch 200Amp. = 1 No.
Supply, erection, testing and commissioning of wall mounted electrical LT panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900 mm and 400mm deep having following accessories :- A) At water works) For Clear water pump set 1100 LPM x 45 M. Head 2 Nos. pump sets (One for Two Pump set) A) Main switch 100 Amp 1 No. (L&T siemens, ABB). b) Volt Meter 100 X 100mm range of range 0 to 500 Volt = 1 No. (AE/KAPPA/L&T) c) Amp Meter 100 X 100mm range of range 0 to 100 Volt = 2 No. (AE/KAPPA/L&T) d) CT 100/3Nos. (AE/KAPPA/L&T) e) VSS & ASS 1 No. each No. of approved make f) SSP 4 No. of approved make/minilac g) Motor starter star delta 2 Nos. for 1100 LPM x 45 M Head Motor (L&T, Siemens, ABB) h) Capacitor KVAR as per site requirement i ) Indicating Lamp = One Set j) Change over Switch 200Amp. = 1 No.
Supply and jointing three core cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for Clear water & Raw water Pump motors/Fountain loghts etc with voltage grade 1100 volts marked with IS :694 1990 including cost of jointing, materials as well as carriage loading, unloading etc. complete in all respect upto the entire satisfaction of Engineer-in-charge
Operation and maintenance for complete scope of work mention in the DNIT ( Disinfection material supplied by the PHED) as per Schedule-IV for a period 5 year after 12 month during defect liablity period 3 months trial run will be charged to the A/Mtc estimate
Operation and maintenance during defect liability period (Operation only)
Operation and maintenance during 1st year after defect liability period
Operation and maintenance during 2nd year
Operation and maintenance during 3rd year
Operation and maintenance during 4th year
Operation and maintenance during 5th year
Bidder Name
Amount
Pardeep Kumar Contractor(GSTN-06AQDPK9866B1ZR)
RAJKUMAR(GSTN-06BMEPK8901M1ZS)
OM PARKASH CONT(GSTN-NA)
RAJ KUMAR CONT(GSTN-NA)
Mukesh Rathee contractor(GSTN-NA)
Pardeep Kumar Contractor
Mukesh Rathee contractor
OM PARKASH CONT
RAJ KUMAR CONT
Pardeep Kumar Contractor
OM PARKASH CONT
RAJ KUMAR CONT
Mukesh Rathee contractor
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .