Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC 16 GANGADHAR BABU LANE C R AVENUE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | ₹30.6 L Quoted ₹30.8 L | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹32.0 L+₹1.2 L (3.95%)Rejected-Finance | ₹32.0 L+₹1.2 L (3.95%) | L2 | Rejected-Finance Being not lowest |
| 3 | L3₹33.0 L+₹2.3 L (7.31%)Rejected-Finance ROWRIAH KB ROAD PO CHALIHA JORHAT 785004 ASSAM | JORHAT | JORHAT | ASSAM | 785004 | ₹33.0 L+₹2.3 L (7.31%) | L3 | Rejected-Finance Being not lowest |
| 4 | L4₹33.2 L+₹2.5 L (7.98%)Rejected-Finance | ₹33.2 L+₹2.5 L (7.98%) | L4 | Rejected-Finance Being not lowest |
| 5 | L5₹33.9 L+₹3.1 L (10.1%)Rejected-Finance | ₹33.9 L+₹3.1 L (10.1%) | L5 | Rejected-Finance Being not lowest |
Tender Value
₹29.8 L
EMD Value
₹59,700
Closing Date
24 Nov 2022, 6:00 pmClosed
GARRISON ENGINEER
Garrison Engineer Jorhat - 785005
PRON OF SCOOTER/ CYCLE STAND(RW-24/22-23), PROVN OF PATHWAY NEAR BLDG NO-P-03(MIN-29/22-23) AND SPL REPAIRS TO BLDG NO P-04 ASC (SR/BLDG-08/22-23) AT UNDER GE JORHAT
2022_MES_561317_1
8088/E8
Open Tender
Civil Works
Item Rate
180 days
GE JORHAT
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE JORHAT
₹59,700
Yes
3 Dec 2022
3 Nov 2022
26 Nov 2022
3 Nov 2022
24 Nov 2022
18 Nov 2022
3 Nov 2022 - 8 Nov 2022
Amount
NOTES :(i)The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Surface dressing not exceeding 15 cm deep in soft/loose soil
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out as in soft/loose soil.
Excavation in post holes not exceeding 0.5 cum and getting out and returning filling in, ramming earth in layers not exceeding 25 cm thick, watering and removing surplus soil to a distance not exceeding 50m and making good in hard/dense soil.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level n. exc. 1.50 m above the starting point.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm as in soft/loose soil.
Material and labour for Plain Cement Concrete M-7.5(Nominal Mix) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed.
Material and labour for Plain Cement Concrete M-10(Nominal Mix) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed.
Material and labour for Plain Cement Concrete M-15(Nominal Mix) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed.
Material and labour for TMT Bars Fe 500D 6mm & 8mm dia cut to length bent to shape required inculding cranking bending spirally hooping for columns etc and binding with MS wire ennealed less than 0.9mm dia or securing with clip complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level)
Demolition of cement concrete (un-reinforced) in ground floors, sunken floor and paving complete all as specified
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to stores and rubbish off the MOD premises complete all as specified and as directed.
Material and labour for Hard core of gauge not exceeding 63 mm of broken stone or boulders , spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface
Material and labour for Plain Cement Concrete M-15(Nominal Mix) using 20 mm gaded stone aggregate as in Surface channel and drain
Plain Cement Concrete M-15(Nominal Mix) using 12.5 mm graded stone aggregate as in making good window opening, lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, coping, kneelers, apex stones, bed plates, kerbs, water trough and the like including weathering slightly rounded or chamfered angles and throating as directed
Material and labour for 150 mm thick plain cement concrete 7.5 (Nominal Mix) using 40 mm graded stone aggregate as in sub base floor complete all as specified and as directed.
Material and labour for 100 mm thick cement concrete M-15(Nominal Mix) using 20 mm graded stone aggregate as in floor laid in alternate panels, finished even and smooth using extra cement and spike rolling to surface or making impression of expanded metal whilst the concrete is green complete all as specified and as directed.
Material and labour for 15 mm thick Wearproof topping as specified (incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth complete all as specified and as directed.
Material and labour for Forming 12 mm thick expansion joints filled with compressible filler board and top 30 mm filled with polysulphide sealant, thickness of concrete slab in 100 mm all specified in relevant para & sub para of 20.B.7 in SSR Part-I complete all as directed.
Material and labour for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with polysulphide sealant all specified in relevant para & sub para of 20.B.7 in SSR Part-I complete all as directed.
Material and labour for Forming Contraction joints 30mm deep x 10mm wide, filled with polysulphide sealant all specified in relevant para & sub para of 20.B.7 in SSR Part-I complete all as directed.
Material & Labour Non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular area of each tile exceeding 0.06 Sqm and not exceeding 0.11Sqm , in floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed layer in CM (1:4) including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushign neat cement slurry with 3.0 kg of cement per Sqm complete all as specified and as directed.
Material & Labour of vitrified ceramic tiles,double charged, light coloured shade, 10 mm thick of square/rectangular area of each tile not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match over 15mm thick screed bed layer in CM (1:4)complete all as specified and as directed.
Material & Labour Glazed ceramic tiles 400x300x7 mm(Coloured) on vertical surfaces such as skirting, dados and riser to steps etc. set and jointed in neat cement slurry and pointed in coloured cement to match complete over 10mm thick screed bed vertical layer in CM (1:4)all as specified and as directed.
Material & Labour of 18mm thick granite ( of any type) work ( table rubbed and polished in pillars and like set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust admixture of pigment to match with shade of granite over 15mm thick screed bed layer in CM (1:4) including taking down existing one complete all as specified and as directed.
All as per item No ___ here-in-before but to vertical surfaces such as skirting over and including 10mm thick rendering in CM (1:3) complete
Material & Labour for providing edge moulding to 18-20mm thick stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete all as specified and as directed.
Materials and labour for sunken floor water proofing treatment of various layers from bottom to top on all surfaces of slab in following sequence and including demolition and removal of existing surfaces complete all as specified and as directed. (i) Slope correction by using M-20 (Nominal mix) concrete by using 12.5mm graded stone aggregate with integral water proofing compound ( minimum 2%), finished even and smooth using extra cement all as specified and as directed. (ii) Application two coats of elastomeric cementitious water proofing on sunken wall & floor surface as per the manufacturers instruction (iii) Concrete for sunken slabs shall be mixed with WP compound as per manufacturers Instructions.(To be measured separately) (iv) Joint of Trap/WC/Soil pipes shall be properly sealed with sealing compound( if required) (v) Testing of all traps & joints and sunken slab shall be as per IS-1742 before filling of sunken slabs, including smoke tests. (vi) 25 mm outer dia of CPVC pipe spout pipe of 600 mm length Note:- This item shall be measure in length & breath of floor area and paid accordingly.
Material & Labour for Plain Cement Concrete M-7.5(Nominal Mix) using 40 mm graded stone aggregate as in mass concrete in sunken floor complete all as specified and as directed.
Material , Labour and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever complete all as specified and as directed..
Material , Labour and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed..
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Taking down cement plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. and removal outside of MOD land complete all as specified and as directed.
Rendering 15 mm in Cement Mortar 1:6 on fair faces of brick work or concrete surfaces finished even smooth without using extra cement to the plastered surface complete all as specified and as directed.
Material and labour for Rendering 15mm thick plaster in Cement Mortar (1:4) on fair faces of brick or concrete surface of wall and finished even and smooth without using extra cement, with water proofing treatment. Note:- Water proofing compound shall be measure and paid separately
Rendering 5 mm in Cement Mortar 1:3 on fair faces of brick work or concrete ceiling surfaces finished fair
Supply only integral liquid water proofing compound
Material and labour for Preparation of new surface and applying 3 coats white wash on walls surface complete all as specified and as directed.
Material and labour for Preparation of new surface and applying 3 coats white wash on ceiling surface complete all as specified and as directed.
Material and labour for preparation of old internal ceiling surfaces and applying a coats of white wash complete all as specified and directed.
Material and labour for preparation of old internal wall surfaces and applying a coats of white wash complete all as specified and directed.
Material and labour for complete removal of existing finishing of internal wall surface of building/structure by mechanical appliance and applying 2 coats of cement based paint over a coat of alkali based primer of any description over 10 cm girth or width complete all as specified and directed.
Material and labour for preparation of new surfaces and and applying 2 coats of cement based paint over a coat of alkali based primer complete all as specified and directed.
Material and labour for preparation of old internal wall surfaces and applying a coats of cement based paint complete all as specified and directed.
Taking down chowkats/frames with shutters (without taking off shutters from the frame) etc. exceeding 1.50 Sqm but not exceeding 4.00 Sqm each complete all as specified and as directed.
Taking down chowkats/frames with shutters (without taking off shutters from the frame) etc. not exceeding 1.50 Sqm each complete all as specified and as directed.
Material and labour for Solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with Mild Steel square tube, suppling & fixing in opening as per drawing complete all as specified and directed.
Material and labour for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawingcomplete all as specified and directed.
Material and labour for Butt hinges Stainless steel 100 mm size complete all as specified and directed.
Material and labour for Aluminium anodised barrel tower bolts of extruded section size 300 mm complete all as specified and directed.
Material and labour for Aluminium anodised barrel tower bolts of extruded section size 150 mm complete all as specified and directed.
Material and labour for Floor door stopper of SS body and tongue, anodised, with hard drawn steel spring of size 150 mm, fixed in floor complete all as specified and directed.
Material and labour for Aluminium handles cast type anodised 125 mm size complete all as specified and directed.
Supply and fixing of powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
Supply and fixing of powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
Supply and fixing of aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum thickness of powder coating 50 micron) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in- charge.
Supply and fixing in repairs of figured glass with sheet glass 4 mm thick , pin head type and glazing with oil putty in squares n exc 0.5 sq. M in each pane complete all as specified and as directed.
Material and labour for Painting 2 coats of synthetic enamel paint on wooden surfaces of any description over 10 cm in width or girth including preparation new surface and one coat of pink primer complete all as specified and as directed.
Material, labour and fixed of aluminium snap grid frame work for false ceiling, size of grid 605 x 605 mm, including aluminium main/closs tee of size 35mm x 23mm x 1.5 mm ( minimum) aluminum BULBED TEES section and aluminium angle of 25mm X 25mm X1.5mm thick, sutiable type GI wire hanging arrangement with adjuster all as specified in clause no 10.38 in SSR part-I and including 4mm thick high pressure steam cured non asbestos fibre cement designer board as per IS 14862 with applying of two coats of acrylic distemper over a coat of primer including taking dwon existing false ceiling system complete all as specified and directed.
Material and labour for Rolled mild hollow steel sections steel of grade YSt 310 conform to IS 4923-1997 in roof trusses (framed), trussed, purlins, bracing and fastenings including distance pieces, cleats etc.
Supply and fixing of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Material and labour for preparation of new steel surface and applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel and iron surfaces of any description over exceeding 10 cm in width or girth complete all as specified and as directed..
Stripping out tarfelt from old roof surfaces and removing unserviceable materials from site of work in low laying in outside MOD area complete all as specified and as directed.
Material and labour forrendering 15 mm(Avg) thick in Cement Mortar 1:4 finished even and smooth witht using extra cement after preparation of old roof surface with brushing and applied neat cement slurry with 3.0 Kg of cement per Square Metre existing surface complete all as specified and as directed
Supplying and laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 3.6 kg/Sqm water proofing membrane, black finished reinforced with non woven polyester matt laying over a coat of bituminous primer @ 0.40 Ltr / Sqm and two coats of Bitumen based UV reflective paint with aluminium finish over APP membrane. The membrane shall be laid using butane torch and sealing all joints etc all as specified in Para 11.44.5 of SSR Part I complete all as specified and as directed.
Supply and fixing in repair of bib cock cast copper alloy screwed down with long body with wall flange, and fixed for 15 mm bore GI tube pipe and all accessories complete all as specified and as directed. complete all as specified. Make :- Cat no PIS -08 of Prayag or equivalent model of make list as given in PS as approved by GE.
Supply and fixing in repair of chromium plated pillar cock cast copper alloy screwed down with long body with wall flange, and fixed for 15 mm bore GI tube pipe and all accessories complete all as specified and as directed. complete all as specified. Make :- Cat no PIS 02 of Prayag or equivalent model of make list as given in PS as approved by GE.
Supply and fixing in repair of stop valve standard of PTMT any colour high pressure screwed for 15 mm bore dia iron pipe and fixed .(Minimum weight 15mm-90gms) complete all as specified.
Supply and fixing of Vitreous china wash down water closet (pedestal pattern) with concealed S-trap or P-Trap, white, 390 mm high, seat cover including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc and including taking down existing one complete all as specified and as directed Mak:-SLICK of HINWARE or equivalent model of make list as given in PS as approved by GE."
Supply and fixing as in repair of health faucet of ABS body with wall hook and including one metre long stainless steel braided rubber hose pipe fixed on 15 nn dia angle cock all complete complete all as specified and directed Make:- Cat No. BEA-41 Prayag equivalent model of make list as given in Approved Make list .
Supply and fixing of vitreous china wash basin white flat back, size 550 x 400 mm including CP waste coupling,with GI pipe brackets & , rag bolt in cement concrete/brick wall and including taking down existing HWB and making good wall surface complete all as specified and as directed. Make: Cat no S2040103 wash basin of CERA or equivalent model of make list as given in PS as approved by GE.
Supply and fixing as in repair of PVC low level flusing cistern 10 litres capacity white with ball valve & brackets with flush pipe complete all as specified and as directed. Make: CHIVAS of CERA or equivalent model of make list as given in PS as approved by GE.
Supply and fixing of uPVC of type-B for use in soil and waste discharge systems, single socket, 110 mm bore in any length including rubber ring joints and fixed to walls with clips and other standard material and including taking dwon old rain water pipe & removal from site all as specified in IS 13592 complete all as specified and directed.
All as per item no 76 above but 75mm bore complete all as specified and directed.
All as per item no 76 above but 110mm bore laid in treanches complete all as specified and directed.
Supply and fixing of Unplasticized (uPVC )bend for 110 mm bore uPVC pipe complete all as specified and directed.
Supply and fixing of Unplasticized (uPVC )bend for 75 mm bore uPVC pipe complete all as specified and directed.
Supply and fixing of Unplasticized (uPVC )juction equal or unequal for 110 mm bore uPVC pipe complete all as specified and directed.
Supply and fixing of PVC(SWR) vent cowl, 110 mm bore
Supply and fixing of PVC (SWR) floor trap, plain with grating including jointing with solvent cement, 75 mm dia of outlet.
Supply and fixing Hard drawn steel wire fabric (weight exceeding 4 Kg per Sqm) cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.90 mm in dia supplied and fixed in reinforcement complete all as specified and as directe
Subtotal of Sch A part-I
SCHEDULE 'A' PART - II FOR E/M PORTION (Sl No __ to ____)
Taking down carefully unserviceable copper / aluminium point wiring (light, fan, bell socket or power) including all fittings such as switches, socket, ceiling roses , regulators and switch boxes etc complete and making good the disturbed surfaces complete all as specified and as directed.
Material and labour for point wiring with 1.5 Sq. mm (nominal area) PVC insulated and sheathed single core FRLSHcopper cable 1100 volts grade with stranded copper conductor in and including PVC rigid concealed conduit (heavy grade) and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and sheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly complete for one light/fan point controlled by one switch complete all as specified and as directed.
Material and labour for point wiring with 1.5 Sq. mm (nominal area) PVC insulated and sheathed single core FRLSHcopper cable 1100 volts grade with stranded copper conductor in and including PVC rigid concealed conduit (heavy grade) and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and sheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly complete for one light/fan point controlled by two nos two way switch complete all as specified and as directed.
Material and labour for Point wiring with 1.5 Sq. mm (nominal area) PVC insulated and sheathed single core FRLSHcopper cable 1100 volts grade with stranded copper conductor in and including PVC rigid concealed conduit (heavy grade) and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and sheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly complete for modular one socket outlet 5 pin 6 amps on independent board complete all as specified and as directed.
Material and labour for Point wiring with 1.5 Sq. mm (nominal area) PVC insulated and sheathed single core FRLSH copper cable 1100 volts grade with stranded copper conductor in and including PVC rigid concealed conduit (heavy grade) and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and sheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly for one 5 amps socket outlet on same board with other switch complete all as specified and as directed.
Materials and Labour for Point wiring with 4.00 Sq. mm (nominal area) PVC insulated and sheathed single core FRLSHcopper cable 1100 volts grade with stranded copper conductor in and including PVC rigid concealed conduit (heavy grade) and conduit accessories alongwith continuous earth wire 4.0 Sq mm PVC insulated and sheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly complete for modular one socket outlet 5 pin 16 amps on independent board complete all as specified and as directed. NOTES FOR ITEM NO 88 to 93:-(i) Flush steel terminal box, inner plate and front plates shall be measured and paid seperately. (ii) Cutting chases and making good in walls shall be deemed to be included in the unit rate.
Material and labour for Metal flush box 1 modular complete all as specified and as directed.
Material and labour for Metal flush box 2 modular complete all as specified and as directed.
Material and labour for Metal flush box 3 modular complete all as specified and as directed.
Material and labour for Metal flush box 4 modular complete all as specified and as directed.
Material and labour for Metal flush box 6 modular complete all as specified and as directed.
Material and labour for Metal flush box 8 modular complete all as specified and as directed.
Material and labour for White cover plate with frame (both ineer plate & outer plate cover) , 1 modular complete all as specified and as directed.
Material and labour for White cover plate with frame (both ineer plate & outer plate cover) , 2 modular complete all as specified and as directed.
Material and labour for White cover plate with frame (both ineer plate & outer plate cover) , 3 modular complete all as specified and as directed.
Material and labour for White cover plate with frame (both ineer plate & outer plate cover) , 4 modular complete all as specified and as directed.
Material and labour for White cover plate with frame (both ineer plate & outer plate cover) , 6 modular complete all as specified and as directed.
Material and labour for White cover plate with frame (both ineer plate & outer plate cover) , 8 modular complete all as specified and as directed.
Material and labour for Modular switch 6 Amp single pole one way complete all as specified and as directed.
Material and labour for Modular switch 6 Amp single pole two way complete all as specified and as directed.
Material and labour for Modular switch 16 Amp single pole one way complete all as specified and as directed.
Material and labour for Modular socket 16/6 Amp 3 pin combined shattered complete all as specified and as directed.
Material and labour for Modular socket 6 Amp 2/3 pin combined shattered complete all as specified and as directed.
Material and labour for Modular Electronic type fan regulator step type 120 watt, 230 volt complete all as specified and as directed.
Material and labour for Blanking plate SP with incoming contact complete all as specified and as directed.
Supply and fixing ceiling rose surface bakelite 65x50mm three terminals complete all as specified and as directed.
Supply and fixing of LED surface/ceiling mounting(suspended from ceiling) box type light fitting 20Watt with LED Lamp , drive and made of epoxy powder coated extruded aluminium channel housing with high quality polycarbonate opal diffuser cover & high power LED’s as light source with 120 Lumen per watt (Minimum) and including all other standard accessories as per manufacture instructions ,internally pre-wired including connecting up three core1.00sq. mm copper conductor flexible wire/cable complete all as specified. Make : Model No CCS-100-20-65-HL2-DP-NWH of Crompton/ BCLAB 20W WH LED P of Bajaj or equivalent model of make list as given in PS as approved by GE.
Supply and fixing of LED surface/ceiling mounting(suspended from ceiling) box type light fitting 10Watt with LED Lamp , drive and made of epoxy powder coated extruded aluminium channel housing with high quality polycarbonate opal diffuser cover & high power LED’s as light source with 110 Lumen per watt (Minimum) and including all other standard accessories as per manufacture instructions ,internally pre-wired including connecting up three core1.00sq. mm copper conductor flexible wire/cable complete all as specified. Make : Model No CCS-103-10-65-SL-DP-NWH of Crompton or equivalent model of make list as given in PS as approved by GE.
Supply & Fixing of LED street light fitting ( Building Security light) of 35Watt with LED lamp’s & driver and made of pressure die-cast aluminum housing, IP 65/IP 66 road way luminaries with UV stabilized polycarbonate cover or toughen glass cover & high power LED’s as light source with 110 Lumen per watt and electronic driver with efficiency > 85% . The light fitting shall be fixed on wall/pole with and including 25 mm dia( or higher size as per manufacturers recommendation) light grade GI pipe (bend to shape or as per manufacturers recommendation ) bracket 1.5 mtr long complete with MS flat iron clamp (clamps shall be 40 x 5 mm MS flat) nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primer and including taking up old light fitting complete all as specified and as directed Make:- Model No- TRP-400-35-57-SL-LM-NSR of Crompton Greave/ NXT P 36L WH CR PC SD of Bajaj or equivalent model of make list as given in PS. Notes : GI pipe bracket and clamps shall be deem to be included above quoted rate..
Supply and fixing of sub main wiring with two single core 6.0sqmm (nominal area) PVC insulated copper conductor FRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked in PVC double lock casing caping and accessories accessories including one single core 6.0 sqmm copper conductor cable FRLSH as earth wire and including taking out old sub-main wiring complete all as specified and as directed. NOTE:- (a) All runs of copper conductor and one run of conduit shall be measured as one run length.
Supply and fixing of sub main wiring with four single core 6.0sqmm (nominal area) PVC insulated copper conductor FRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked in PVC double lock casing caping and accessories accessories including two single core 6.0 sqmm copper conductor cable FRLSH as earth wire and including taking out old sub-main wiring complete all as specified and as directed. NOTE:- (a) All runs of copper conductor and one run of conduit shall be measured as one run length.
Supply and fixing of sheet metal enclosure for MCBs to be used singal pole & nutral double door 6Way 200 Amps rated busbar and including fixed with 25mm x 6 mm mild steel clamp of suitable length and including taking out old DB complete all as specified and as directed.
Supply and fixing of sheet metal enclosure for MCBs to be used triple pole & nutral double door 4 Way 200 Amps rated busbar and including fixed with 25mm x 6 mm mild steel clamp of suitable length and including taking out old DB complete all as specified and as directed.
Supply and fixing in repair of Sheet metal enclosure verticaly distribution board TPN 415 Volt 04 way ,double door type and provision for 4 pole MCCB complete with 200 Amps rated vertical insulated busbar and including taking out old DB complete all as specified and as directed.
Supply and fixing of MCB SP of rating 6 to 32 Amps 240 V complete all as specified and as directed.
Supply and fixing MCB DP 40 to 63 amps 415 volts 10KA breaking capacity.
Supply and fixing MCB four pole 40 to 63 amps 415 volts 10KA breaking capacity.
Supply and fixing in repair of MCCB 80 amps, 4 pole, breaking capacity 16 KA suitable for operation of 415 volts AC 50 HZ with fixed type all as specified in SSR Part -I including making necessary electric connections complete all as specified and directed .
Supply and fixing of Metal distribution box with clad plug and socket and including SPN-MCB control 2 pin & earth plug with socket , 20 A, 240 Volts universal type complete with one MCB 20 A SPN 240 volt complete all as specified and as directed.
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI 4mm dia wire as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layer and complete all as specified and directed .
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ₹ ___________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
M/S RK SAHA AND CO
M/S DHAR AND DHAR
M/S GOPAL ROY AND CO
MS J B CONSTRUCTION AND CO
M/S DILIP GOSWAMI
AJOY DUTTA CHOWDHURY AND CO
SURAJIT GOGOI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .