Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC 65 DEEP NAGAR BIRRING ROAD JALANDHAR CANTT PB | L1 | Accepted-AOC L1 | |
| 2 | L2₹34.5 L+₹52,099 (1.53%)Rejected-Finance 15 GURU RAM DASS COLONY MITHAPUR JALANDHAR | L2 | Rejected-Finance L2 | |
| 3 | L3₹35.0 L+₹1.0 L (3.08%)Rejected-Finance 129 PANCH SHEEL VENUE DEEP NAGAR JALANDHAR CANTT PB | JALANDHAR | PUNJAB | 144001 | L3 | Rejected-Finance L3 | |
| 4 | L4₹36.3 L+₹2.4 L (6.93%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹40.1 L+₹6.1 L (18.0%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹43.6 L
EMD Value
₹87,280
Closing Date
22 Apr 2025, 6:00 pmClosed
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
SPECIAL REPAIR IN BLDG NO T-09 (OTHER RANKS LIVING) OF 125 SATA REGT AND CERTAIN OTHER SANCTIONED WORK UNDER GE (EAST) JALANDHAR CANTT
2025_MES_702377_1
GE/JULL/ET-86/2024-25
Open Tender
Civil Works
Item Rate
183 days
Jalandhar Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹87,280
11 Jun 2025
24 Mar 2025
29 Apr 2025
24 Mar 2025
22 Apr 2025
8 Apr 2025
Amount
Dismantling plain or corrugated asbestos cement sheet as in roof coverings, complete all as directed.
Dismantling wrought iron or mild steel work of any description complete all as directed.
Dismantling wall and ceiling boards (fibre, pulp, un-insulation etc) or un-insulation boards/ slabs/ blankets any thickness including cover fillet complete all as directed
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation borads /slabs, blankets, any type, any thickness and any shape including cover fillets and frame work. complete all as specified and directed
Taking down cement plaster or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc any description complete all as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises complete all as directed.
Demolition of cement concrete in ground floor and paving not exc 15cm thickness (below or above ground level) and removing surplus spoil out of Defence Land where directed at a level not exc 1.5 m above the starting point complete all as directed.
Demolition of brick work built in cement mortar incl all quoins, arches pillars etc but excluding precast concrete articles all as specified
S&F Pre- painted galvalume aluminum zinc coating Gi based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. Make:- Tata Blue Scope/ JSW
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
S&F Rolled mild steel work in roof trusses (framed),trussed, purlins, rafters, crane gantries and heavy brackets framing (beams, tee, angle, channel or flat section) including MS plates, nut bolts etc complete conforming to Fe 410-W(Gde, E-250) Quality A complete all as specified and directed
M&L for 6mm thick asbestos fibre cement plain building boards fixed to iron angle frame work with screws as in flat ceiling complete all as specified and as directed.
M&L 15mm thick cement plaster in cement mortar 1:6 on brick or concrete surface finished even and smooth without using extra cement complete all as specified and as directed.
M&L 15mm thick cement plaster in cement mortar 1:4 on brick or concrete surface with water proofing compound finished fair and even without using extra cement all as specified and as directed.
M&L for preparation of new plaster surfaces of walls and applying two coats of oil bound distemper including a coat of primer on plastered surfaces over 3mm thick wall care putty on wall complete all as specified
M&L for complete removal of existing surface of walls and applying two coats of oil bound distemper over 3mm thick wall care putty in two layers on wall including a coat of primer on wall complete all as specified.
M&L for preparing new plastered or unplastered wall surfaces and applied two coat of cement base paint complete all as specified and directed.
M&L for complete removal of existing treatment of wall surfaces and applying two coat of cement base paint complete all as specified and as directed.
M&L for preparation of old steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed
M&L for preparation of new steel surfaces of any description, not otherwise described over 10cm width or girth and applied two coat of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed
M&L for non skid joint free ceramic coloured tiles (premium Quality) of area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm and 7-8 mm thick in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed. Make:- Kajaria/Somany/Johnson
All as per Srl item No. 22.00 here-in-before but in skirting and 10 mm thick rendering as back coat of CM (1:4) complete all as specified and directed
M&L for roughing surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed
M&L for 20 to 25mm thick Kota stone machine cut and prepolished, jointed and pointed grey cement slurry laid over 15mm thick screed bed of CM (1:6) mixed with pigment to match the colour of stone slab complete all as specified and directed.
All as per Srl item No. 25.00 here-in-before but on vertical surfaces such as skirting etc over and including 10 mm thick cement plaster finished even and rough to receive tiles in Cement mortar (1:4) complete all as specified
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exc 6 M mean radius built in CM (1:6) complete all as specified. and as directed
M&L for 50mm thick PCC 1:3:6 type C1 using 40mm graded aggregate as in plinth protection/surface channels finishing the surfaces even and smooth without using extra cement all as specified.
S&F glass dividing strips, 38 mm width 3mm thick and inserted in position to confirming to design complete all as specified and directed
M&L for mild steel pipe 25 mm dia curtain road with PVC coating fixed in the MS hooks, and finials/side brackets (both side), shade complete all as specified and directed.
M&L for PCC (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) as in benching, padding, roof kerbs or mud stops, coping etc rounded or chamfered on edges complete all as specified and directed
Demolition of brick tiles single layer as in roof covering complete all as directed
Demolition of mud in roofs any thickness including plastering and leeping (whether full thickness removed or only a part thereof) all as specified
M&L for 10mm thick cement plaster in cement mortar (1:3) mixed with integral water proofing compound in the proportion recommended by manufacturer, on concrete roof surfaces finished even and fair, including cleaning the roof top by scraping down with water etc all as specified and directed by Engineer-in-Charge (WPC shall be measured and paid separately under appropriate item of this BOQ).
Cleaning the surface and made free of dirt, foreign particle, laitance followed by grinding all all protrusion to make surface modulated. Thereafter, inspection for cracks on the surface caused by thermal expiation contraction. Cutting the grooves with suitable cutter machine in V-groove filled with repairs mortar/ microconcrate/ general purpose grout as recommended proportionally as per recommendation of manufacture. Making of Gollas at all the corners with polymer modified mortar (1:4) cement sand with 3.5% acylic of cement weight complete all as specified and directed.
Supply and applying high build elastomeric waterproofing coating based on pure hydrophobic polyurethane cold applied of spray/brush applied, membrane with an elongation of 280% and tensile strength of 2.7N/mm2 as per ASTM D 2370, crack bridging ability of 3mm, no leakage upto 5 bars of water pressure as per DIN 1048, min 88% solid content. The system includes final base preparation, epoxy primer 1:1 (Resin; harder) application with 100% water dilution and Pure polyurethane application in 2 coats with a total min consumption of 1.25 kg per Sqm. Application should be done with Graco sprayer by a company authorised applicator” complete all as specified and directed. Note:- Contractor wise submitt certificate from authorised applicator.
Demolition of brick work as in walls/parapet walls removing grass fungus weed, roots of trees completely, grown on roof/wall surfaces, complete all as specified and directed
M&L for solid PVC wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC Frame complete all as specified and directed.
M&L for 5mm thick PVC sheet fill it of width of width 35mm for wall panelling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed
M&L for hacking out old broken glass (any thickness, size quality or description) from wooden or steel frame glazed with putty or fixed with beads complete all as specified and directed
S&F sheet glass ordinary quality 3.0 mm thick in square not exc 0.50 Sqm each pane glazing with oil putty, clip in metal frame and wooden beading in wooden frame/door/window etc complete all as specified
S&F in repairs door closer hydraulically of aluminium extruded section body regulated, designation No-3, universal type, suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80 Kg and fixed complete all as specified.
S&F in repair fancy CP Bib Cock long nose (Foam Flow) with Flange for fixing to 15mm bore (dia) GI Pipe, complete as all specified and as directed. Make:- Jaguar/Cera/ESS-ESS
S&F in repair floor door stopper 140mm of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor all as specified and directed by Engineer-in-Charge. Make:- Jaguar/Cera/ESS-ESS
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. Tubes for top & bottom rails M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, fixing in the frame at the site as per specification & drawing
S&F PVC solid door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing
S&F100mm size stainless steel butt hinges for fixing to PVC doors all as specified.
S&F aluminium anodised tower bolts 200 mm size fixed with machine screws complete all as specified and directed.
S&F aluminium anodised Bow Handles 150 mm size fixed with machine screws complete all as specified and directed
Taking down carefully existing point wiring of any type/ any size (ie on wooden/ batten, surface conduit, casing capping or concealed conduit) complete for unsv light, socket or power point etc including removing switches, sockets, holders, ceiling rose, pendants, regulators, light fittings, switch board outlets with sheets and other materials from site for refixing of serviceable light, accessories for taking credit of unserviceable light and accessories as per Sch of credit and making good disturbed surface of walls, roof, floors etc. with any type of civil wk involved complete all as specified and directed.
M&L for point wiring for light/fan/call bell point with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor of size 1.5 Sqmm cable drawn in and including concealed rigid PVC conduit medium grade not less than 20mm dia with accessories including cutting chases for laying of conduit /fixing of boxes in walls/floor etc including making good to disturbed surfaces as per adjoining specification and terminated in and incl sunken pressed steel boxes duly painted with anti corrosive paint over a coat of red oxide primer with plastic laminated bakelite sheet top cover 3mm thick make hylum or equivalent fixed with nickel polished screws with cup washers etc including FRLS PVC insulated unsheathed multi stranded copper conductor 1.5 Sqmm single core as earth continuity conductor (green colour) connected with earth dolly with thimble complete all as specified and as directed by Engr-in-Charge.
All as per Srl item No. 52.00 here-in-before but for one socket outlet 5 Amps on independent board complete all as specified.
All as per Srl item No. 52.00 here-in-before but for one socket outlet 5 Amps on the same board controlled complete all as specified.
All as per Srl item No. 52.00 here-in-before but with 2.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multistranded copper conductor cable for one 3 Pin 15 Amp socket on independent board including one 2.5 Sqmm copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and directed by Engineer-in-Charge.
S&F switch piano flush type, 6 Amps single pole, one way complete all as specified.
S&F switch piano flush type 16 Amps single pole, one way complete all as specified.
S&F socket out let 6 Amp, 5 pin, 2-in-1 flush type complete all as specified.
S&F Socket outlet multi purpose 2 in 1, 5/6 pin, 5 & 16 Amps, flush type complete all as specified.
S&F in replacement Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with matching colour back plate all as specified and directed.
S&F five step fan regulator, electronic type, single phase, including connection complete all as specified
S&F ceiling rose surface type PVC/ polycarbonate 65mm x 50mm three terminal complete all as specified.
S&F in replacement LED tube light fitting polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
S&F in replacement LED light fitting 1 x 10 Watt, appx 2 feet long with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6000K (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
S&F in replacement energy efficient LED security light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Fixing only serviceable tube light fittings any type and any description retrieved under Srl item No. 51.00, including necessary electric connection with round flexible wire with multi stranded copper conductor of size 0.50 sqmm, 3 core, 1100 volts grade complete all as directed.
S&F in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 8 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessary complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ
S&F in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 250 Amp rated bus bar) VTPN, 4 Way 415V, suitable for mounting MCCB/MCB, conforming to IS-13032, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessary complete all as specified and directed by Engineer-in-charge. Make of Sr Item No. 68 to 71:- ABB/Schnider/Legrand
S&F in replacement MCCB TPN 125 Amps , 415 Volts, 25 KA ,4 POLE, Ics=100% Icu , overload adjustable short circuit fixed type incl complete connection with suitable spreaders all as per direction of Engr-in-Charge
S&F in replacement MCB ‘B’ curve suitable for 230 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-Charge
S&F in replacement MCB ‘C’ curve suitable for 230 volts AC supply, 40 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-Charge
S&F down rod of GI pipe medium grade 15 mm dia bore with slot & provision of 2 Nos hole of suitable size on top & bottom of size upto 2.5 mtr length complete painted with two coat of synthetic enamelled paint complete all as specified and directed by Engr-in-charge
M&L for ceiling fan fixing clamp/bracket to be fixed with purlin/steel structure/wooden joist made of MS flat iron 40 x6mm minimum of suitable length and bent to shape matching with structure to which it should be fixed including suitable fixing arrangement of down rod 15mm dia with clamp bolt, nuts and incl preparation of surface with iron oxide and two coat of synthetic enamelled paint complete all as specified and directed
M&L in replacement for sub main wiring with (4x10 Sqmm) four run of single core FRLS PVC insulated unsheathed multi-stranded copper conductor cable of 10.0 Sqmm drawn through in and including new PVC rigid non-metallic concealed conduit (medium grade) with all fittings including earth continuity single wire FRLS PVC insulated unsheathed multi-stranded copper conductor cable 10.0 Sqmm ( green insulation) with any type of civil work including making good to disturbed surfaces to match existing surface complete all as specified. Note : Four run of 10.0 sqmm wire and one run of 10.0 sqmm wire as earth wire including PVC conduit shall be measured as one unit
M&L in replacement for sub main wiring with two run of single core FRLS PVC insulated unsheathed multi-stranded copper conductor cable of 6.0 Sqmm drawn through in and including new PVC rigid non-metallic concealed conduit (medium grade) with all fittings including earth continuity single wire FRLS PVC insulated unsheathed multi-stranded copper conductor cable 6.0 Sqmm ( green insulation) with any type of civil work including making good to disturbed surfaces to match existing surface complete all as specified. Note : Two run of 6.0 sqmm wire and one run of 6.0 sqmm wire as earth wire including PVC conduit shall be measured as one unit
M&L for Earthing complete in replacement with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick burried directly in ground (earth pit not less than 2.25 meters deep below normal ground level with the top edge of electrode not less than 1.5 meters below normal ground level connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and incl GI lead protection pipe of GI light grade 15mm dia upto 7.5 mtrs and watering pipe 20mm bore of GI medium grade with funnel and wiremesh, earth plate covered on all sides with min 150mm thick alternate layers of charcoal, salt all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing point with PCC chamber and RCC cover in 1:2:4 complete with any type of earth work involved all as specified and directed and testing on completion. Note:- PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner.
M/S Kuldip Construction Co. (BID ID -3285780)
S S CONSTRUCTION (BID ID -3286043)
M/S Vinod Kumar (BID ID -3281256)
M/s Nirmal Singh and Co. (BID ID -3285829)
M/s GURFATEH BUILDERS (BID ID -3282077)
NATIONAL BUILDERS (BID ID -3285711)
SANMATI UDYOG (BID ID -3285855)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .