| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L1 | Accepted-AOC AOC Issued | |
| 2 | L2₹9.9 L+₹33,378 (3.50%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L2 | Rejected-Finance that the bid is not L1 | |
| 3 | L3₹10.2 L+₹61,178 (6.41%)Rejected-Finance | L3 | Rejected-Finance that the bid is not L1 |
Tender Value
Refer Docs
EMD Value
₹19,800
Closing Date
3 Mar 2020, 11:30 amClosed
EE NKHED PW Dte
KIT Building Annex, 4th Floor,P-16, India Exch. Place Extn., Kolkata -700073
Replacement of old Air Condition machine for Fire Safety at different location of IDBG Hospital Beliaghata campus SITC of AC Machine
2020_WBPWD_272889_1
WBPWD/EE/NKHED/NIQ-81/19-20
Open Tender
A/C ORG
Item Rate
30 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹19,800
17 Mar 2020
17 Feb 2020
5 Mar 2020
19 Feb 2020
3 Mar 2020
19 Feb 2020
Amount
SITC of 7.5TR capacity concealed type Split Air Conditioner of rated cooling capacity of 90000 BTU/hr. with 3Nos. twin rotary/Scrool compressor,3nos. IDU of rated power supply-230V-1ph-50Hz. , 1 no. ODU of rated power supply-400V-3ph-50Hz. Air-flow/per IDU:- 1000CFM. including charging of refrigerant ( Make: Hitachi / Daikin / Carrier / Mitsubishi ) Specified air discharged to be varified by agency in presence of Engineer in charge.
SITC of 5 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 60000 BTU/hr. with 2Nos. twin rotary/Scrool compressor,2nos. IDU of rated power supply-230V-1ph-50Hz. , 1 no. ODU of rated power supply-400V-3ph-50Hz. Air-flow/per IDU:- 1000CFM. including charging of410A refrigerant ( Make: Hitachi / Daikin / Carrier / Mitsubishi ) Specified air discharged to be varified by agency in presence of Engineer in charge.
SITC of 2 TR capacity concealed type Split Air Conditioner having rated cooling capacity of 24000 BTU/hr. with rotary compressor ,1 no IDU of rated power supply 230V-1ph-50 Hz,1 no ODU of rated power supply-230V-1ph-50 Hz . AC supply.Air flow/per IDU-800 cfm(make Hitachi,carrier,bluestar)
SITC of 1.5 TR capacity concealed type Split Air Conditioner having rated cooling capacity of 18000 BTU/hr. with rotary compressor ,1 no IDU of rated power supply 230V-1ph-50 Hz,1 no ODU of rated power supply-230V-1ph-50 Hz . AC supply.Air flow/per IDU-650 cfm(make Hitachi,carrier,bluestar)
Supply, Installation & commissioning of hard/soft copper refrigeration pipeline, with 9 mm nitrile rubber tube Insulation on following sizes of suction line & Liquid Line copper pipe with proper insulation tape (Make-Accoflex/ Armacell/K-Flex, complete with fittings, elbows, bends, supporting arrangement on walls (Make- Ryoku/Rajco/Mandev) a) (3/8" OD with 0.6 mm thick)
b) (5/8" OD with 0.7mm thick)
c) 1/4 " OD with 0.8mm thick
Control Cabling from ODU to IDU directed by EIC. a) 4Core 2.5sq. mm. Make- Ploycab/Finolex/Gloster/RR Cable
b) 3 Core 2.5 sq. mm. Make- Ploycab/Finolex/Gloster/RR Cable
Supply & laying Drain Water piping work out of PVC / HDPE hard pipes of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors.Make- Oriplast/ Supreme a) 25mm dia
b) 32mm dia
c) 19 mm dia
Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making platform for installation of outdoor unit of 5/7.5 TR concealed type split/ductable AC incl. drilling 3 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm for including necessary welding for placing the platform, M.S checkered sheet including 50mm x 50 mm x 6 mm Angle in each platform in outer edge for transmitting the load centrally through 2 nos. (50 mm x 50 mm x 6 mm) Angle of 2 mtr. length each inserted into the exiting wall. Area of the platform as follows:- i) 1.5 mt x 1.2 mt:
Special Terms & Conditions :- i) The Agency must procure the materials from the Manufacturer / OEM or from their authorized. Sales channel so that the standard warranty / Support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. ii) Documents that authenticates such procurement form the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM /authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work/submission of bill. iii) If any refurbished material is supplied and installed, panel action will be taken as per existing rules. iv) After completation of work Agency Supervisor has to certify fittness af all Electrical Installations done under this Tender. This is mandatory before peparations of Final Bill. v) Defect libilities period for 01(one) year from the date of completation of work.
(Rate should be quotated including all taxes and duties)
Lyric International
NEW MODERN COOLING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .