| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC C1871 SAMPLA ROHTAK ROHTAK JHAJJAR HARYANA 124501 | ROHTAK | HARYANA | 124501 | L1 | Accepted-AOC L1 | |
| 2 | L2₹2.4 Cr+₹13.4 L (5.91%)Rejected-Finance A 6 200 EAST GOKALPURI LONI ROAD EAST DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L2 | Rejected-Finance L2 | |
| 3 | L3₹2.4 Cr+₹15.9 L (7.04%)Rejected-Finance 781 SECTOR 9 126102 | JIND | HARYANA | 126102 | L3 | Rejected-Finance L3 | |
| 4 | Not Admitted-Fee/PreQual/Technical 204 JHARNA TOLA KUNRAGHAT GORAKHPUR GORAKHPUR UTTAR PRADESH 273001 | GORAKHPUR | UTTAR PRADESH | 273001 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical 451 BLOCK C OPPOSITE GO MESS SUNDER NAGAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | SANDEEP KUMAR CONTRACTOR L3 | HARSHITA ENGINEERING PRIVATE LIMITED L1 | MANKHA ELECTROTECH PRIVATE LIMITED L2 |
|---|---|---|---|---|---|---|
| 1.00 | 45 watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy greater then or equal to 120 not more then 135 lm/Watt
Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
Note: The said description of LED Street Light is taken from amended HSR CHANDIGARH, MONDAY, APRIL 13, 2026 (HSR No. 23.28.13.11) but the said item is not reflection on HEWP portal. So taken as an NS item. Make: Surya/Bajaj/Havells/Phillips/Jaquar/Hallonix | 6,800 | Each | 1,680 ₹1,14,24,000 | 1,570 ₹1,06,76,000 Lowest | 2,085 ₹1,41,78,000 |
| 2.00 | 90watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy greater then or equal to 120 not more then 135 lm/Watt Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
Note: The said description of LED Street Light is taken from amended HSR CHANDIGARH, MONDAY, APRIL 13, 2026 (HSR No. 23.28.13.14) but the said item is not reflection on HEWP portal. So taken as an NS item. Make: Surya/Bajaj/Havells/Phillips/Jaquar/Hallonix | 1,800 | Each | 3,456 ₹62,20,800 | 3,229 ₹58,12,200 | 2,670 ₹48,06,000 Lowest |
| 3.00 | 120 watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy greater then or equal to 120 not more then 135 lm/Watt Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Note: The said description of LED Street Light is taken from amended HSR CHANDIGARH, MONDAY, APRIL 13, 2026 (HSR No. 23.28.13.16) but the said item is not reflection on HEWP portal. So taken as an NS item. Make: Surya/Bajaj/Havells/Phillips/Jaquar/Hallonix | 800 | Each | 4,237 ₹33,89,600 | 3,955 ₹31,64,000 | 3,130 ₹25,04,000 Lowest |
| 4.00 | 150 watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy greater then or equal to 120 not more then 135 lm/Watt Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Note: The said description of LED Street Light is taken from amended HSR CHANDIGARH, MONDAY, APRIL 13, 2026 (HSR No. 23.28.13.17) but the said item is not reflection on HEWP portal. So taken as an NS item. Make: Surya/Bajaj/Havells/Phillips/Jaquar/Hallonix | 400 | Each | 4,708 ₹18,83,200 | 4,395 ₹17,58,000 | 3,606 ₹14,42,400 Lowest |
| 5.00 | 200 watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy greater then or equal to 120 not more then 135 lm/Watt Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Note: The said description of LED Street Light is taken from amended HSR CHANDIGARH, MONDAY, APRIL 13, 2026 (HSR No. 23.28.13.19) but the said item is not reflection on HEWP portal. So taken as an NS item. Make: Surya/Bajaj/Havells/Phillips/Jaquar/Hallonix | 200 | Each | 6,435 ₹12,87,000 | 6,015 ₹12,03,000 | 5,100 ₹10,20,000 Lowest |
Tender Value
₹2.3 Cr
EMD Value
₹4.5 L
Closing Date
21 Aug 2026, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Gopal Kalawat
Municipal Corporation Panipat
Regarding Supply and Erection of 10,000 nos. of various wattages of LED Street Lights MC, Panipat. Recall
2026_HRY_538347_1
2026C706EC39 4494 408D B1D2 41DF9CB332FE286ULB
Open Tender
Civil Works
Works
240 days
Panipat
2 documents required · 2 mandatory
₹5,000
₹4.5 L
Yes
17 Nov 2026
4 Aug 2026
21 Aug 2026
4 Aug 2026
21 Aug 2026
4 Aug 2026
120 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | 45 watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy greater then or equal to 120 not more then 135 lm/Watt
Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
Note: The said description of LED Street Light is taken from amended HSR CHANDIGARH, MONDAY, APRIL 13, 2026 (HSR No. 23.28.13.11) but the said item is not reflection on HEWP portal. So taken as an NS item. Make: Surya/Bajaj/Havells/Phillips/Jaquar/Hallonix | 6,800 | Each | - | - |
| 2 | 90watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy greater then or equal to 120 not more then 135 lm/Watt Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
Note: The said description of LED Street Light is taken from amended HSR CHANDIGARH, MONDAY, APRIL 13, 2026 (HSR No. 23.28.13.14) but the said item is not reflection on HEWP portal. So taken as an NS item. Make: Surya/Bajaj/Havells/Phillips/Jaquar/Hallonix | 1,800 | Each | - | - |
| 3 | 120 watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy greater then or equal to 120 not more then 135 lm/Watt Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Note: The said description of LED Street Light is taken from amended HSR CHANDIGARH, MONDAY, APRIL 13, 2026 (HSR No. 23.28.13.16) but the said item is not reflection on HEWP portal. So taken as an NS item. Make: Surya/Bajaj/Havells/Phillips/Jaquar/Hallonix | 800 | Each | - | - |
| 4 | 150 watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy greater then or equal to 120 not more then 135 lm/Watt Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Note: The said description of LED Street Light is taken from amended HSR CHANDIGARH, MONDAY, APRIL 13, 2026 (HSR No. 23.28.13.17) but the said item is not reflection on HEWP portal. So taken as an NS item. Make: Surya/Bajaj/Havells/Phillips/Jaquar/Hallonix | 400 | Each | - | - |
| 5 | 200 watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy greater then or equal to 120 not more then 135 lm/Watt Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Note: The said description of LED Street Light is taken from amended HSR CHANDIGARH, MONDAY, APRIL 13, 2026 (HSR No. 23.28.13.19) but the said item is not reflection on HEWP portal. So taken as an NS item. Make: Surya/Bajaj/Havells/Phillips/Jaquar/Hallonix | 200 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
BOQ_617541.xls
BOQ • 0.26 MB
AD0165006.pdf
Additional Documents • 0.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .