| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC COLLEGE ROAD KULTI BARDHAMAN KULTI 713343 WEST BENGAL INDIA | KULTI | BARDHAMAN | WEST BENGAL | 713343 | ₹23.6 L | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical DUTTA BAGAN SEN RALEIGH ROAD ASANSOL BARDHAMAN BARDHAMAN 713305 WEST BENGAL INDIA | ASANSOL | BARDHAMAN | WEST BENGAL | 713305 | - | - | Rejected-Technical As per TCR |
| 3 | Rejected-Technical UPPER KULTI PUNJURI P O KULTI BARDHAMAN WEST BENGAL INDIA 713343 | BARDHAMAN | BARDHAMAN | WEST BENGAL | 713343 | - | - | Rejected-Technical As per TCR |
| Sl No | Description | Qty | Unit | BABA LOKENATH TRADERS L1 |
|---|---|---|---|---|
| 1.00Supply and installation of signaling system along the total belt conveyor length in Khottadih colliery. (Inclusive of EPF/CMPF) | ||||
| 1.01 | DGMS APPROVED, BIS CERTIFIED FLP /INTRINSICALLY SAFE
Signalling Bell. STANDARDS CONFORMING TO: IS/1EC60079-
1:2014, IS/IEC60079-11:2011 & IS/1E60079-0:2017. ENDURANCE ТО
HEAT & COLD TEST FOR DMC AS PER IS/IEC60079-0:2017. 15V AC | 23 | nos | 12,000 ₹2.8 L |
| 1.02 | DGMS
APPROVED, BIS CERTIFIED FLP /INTRINSICALLY SAFE POWER SUPPLY
Unit. STANDARDS CONFORMING TO: IS/IEC60079-1:2014, IS/IEC60079-
11:2011 & IS/IE60079-0:2017. ENDURANCE TO HEAT & COLD TEST FOR
DMC AS PER IS/IEC60079-0:2017. (550 V AC - 15 V AC ) | 23 | nos | 25,650 ₹5.9 L |
| 1.03 | GI wire 8 swg (0.116kg per mtr) | 1,044 | kg | 93.22 ₹97,321.68 |
| 1.04 | Bobbin Insulator 1.1kV, Parcelyn , 2x2( 2 pc at every 5 mtr | 3,600 | nos | 70 ₹2.5 L |
| 1.05 | Drill hole in coal and jamming ( at every 5mtr for 9000mtr) | 1,800 | nos | 172.31 ₹3.1 L |
| 1.06 | 4 Core 2.5 Sq.mm
Armoured Cable 1.1KV
Grade PVC Insulated,
PVC Sheathed for connection of PT | 500 | mtr | 205.5 ₹1.0 L |
| 1.07 | Packing and forwarding 3% | 1 | Nos | 48,845.37 ₹48,845.37 |
| 1.08 | Freight 2% | 1 | Nos | 32,563.58 ₹32,563.58 |
| 1.09 | Installation Cost @ 17.77% | 1 | Nos | 2,89,372.4 ₹2.9 L |
Tender Value
₹24.1 L
EMD Value
₹30,200
Closing Date
17 Mar 2026, 6:30 pmClosed
Area Engineer(E and M)
Office of the General Manager Pandaveswar Area , P.O. Pandaveswar, Dist.-Paschim Bardhaman, West Bengal-713346
Supply and installation of signaling system along the total belt conveyor length in Khottadih colliery
2026_ECL_355915_1
GM-PND/EandM/25-26/328/1765 dated 06/03/2026
Open Tender
Electrical and Maintenance Works
30 days
Khottadih Colliery
Please refer Tender documents.
5 documents required · 5 mandatory
₹30,200
16 Apr 2026
7 Mar 2026
18 Mar 2026
7 Mar 2026
17 Mar 2026
7 Mar 2026
7 Mar 2026 - 10 Mar 2026
Supply and installation of signaling system along the total belt conveyor length in Khottadih colliery. (Inclusive of EPF/CMPF)
DGMS APPROVED, BIS CERTIFIED FLP /INTRINSICALLY SAFE Signalling Bell. STANDARDS CONFORMING TO: IS/1EC60079- 1:2014, IS/IEC60079-11:2011 & IS/1E60079-0:2017. ENDURANCE ТО HEAT & COLD TEST FOR DMC AS PER IS/IEC60079-0:2017. 15V AC
DGMS APPROVED, BIS CERTIFIED FLP /INTRINSICALLY SAFE POWER SUPPLY Unit. STANDARDS CONFORMING TO: IS/IEC60079-1:2014, IS/IEC60079- 11:2011 & IS/IE60079-0:2017. ENDURANCE TO HEAT & COLD TEST FOR DMC AS PER IS/IEC60079-0:2017. (550 V AC - 15 V AC )
GI wire 8 swg (0.116kg per mtr)
Bobbin Insulator 1.1kV, Parcelyn , 2x2( 2 pc at every 5 mtr
Drill hole in coal and jamming ( at every 5mtr for 9000mtr)
4 Core 2.5 Sq.mm Armoured Cable 1.1KV Grade PVC Insulated, PVC Sheathed for connection of PT
Packing and forwarding 3%
Freight 2%
Installation Cost @ 17.77%
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_368766.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 2.41 MB
BOQ_368766.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid