Loading…
Loading…
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
28 Aug 2026, 6:00 pm4d left
GE DANAPUR
DANAPUR CANTT
REPAIR MAINT OF LT FP JBs POLE BOX APFC PANELS VOLTAGE STABILIZER HIGH MAST AREA LIGHTING PUMP HOUSE POWER HOUSE STORE OF EM INSTALLATION AT DANAPUR UNDER GE DANAPUR CANTT
2026_MES_783357_1
CA NO GE/DNR/T-49 of 2026-27
Open Tender
Civil Works
Item Rate
180 days
DANAPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE DANAPUR
₹86,000
Yes
7 Aug 2026
7 Aug 2026
4 Sept 2026
7 Aug 2026
28 Aug 2026
21 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M/L in replacement of cross arms, bracing, supports clamps and back plates fabricated from structural steel section incl nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including disconnecting/taking out old existing unsv cross arms complete all as specified and directed. | 0.4 | Qtl | - | - |
| 2 | Supply & Replace MCCB along with both side spreader link and nut bolts of appropriate size (Conforms to IEC:60947-II/IS:13947-II) in exisitng LT Panel box/Feeder Pillar boxes (KIOSK),in MCCB DBs of capacity 630 Amps, 4 Pole, 50KA, 415 Volt including disconnecting/taking out existing old unsv/burned MCCB, Ics= 100% of Icu* Adjustable overload settings: 0.8 - 1.0 x In, Fixed short-circuit settings: 10 x In, complete all as specified and directed. | 1 | Each | - | - |
| 3 | Same as item No 2 here in before but of capacity 200 Amps, 4 pole, 36 KA | 4 | Each | - | - |
| 4 | Same as item No 2 here in before but of capacity 160 Amps, 4 pole, 25KA | 4 | Each | - | - |
| 5 | Same as item No 2 here in before but of capacity 63 Amps, 4 pole, 16 KA | 4 | Each | - | - |
| 6 | S&F MCB, SP 10-32 Amps, 'C' Curve with breaking capacity 6KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed. | 4 | Each | - | - |
| 7 | Supply and fixing in replacement of automatic street light switch using infrared sensor based nature switch for automatic switching of street lights.Nature switch operation should be based on natural light lux level. Required illuminance level for switching on is < 30 Lux and for switching off > 10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs.The sensor along with suitable power contactors incoming outgoing MCBS SP and and automanual (sensor bypass selection option should be enclosed in a pole /wall mountable enclosure made of rust proof electric shock proof termite proof and FR grade SMC Box conforming to IP54 single phase load of 8 KW with circuit wiring min 10 sq mm copper wire 40 Amps contactor ans suitable MCBs at both positions at incoming and out goings of breaking capacity 10 KA complete including necessary clamp (2 sets) / anchor bolt(4 nos) for fixing on pole / walll complete all as directed including taking down old one. | 3 | Each | - | - |
| 8 | S&F in replacement LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete, lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10 KV Built-in-Surge Protection Device, road way light fitting with high power LED as light source of capacity 90 watts with suitable drivers, > 120 Lm/W efficacy,Operating voltage:120–270V AC, 50Hz etc and connecting with 1.5 Sqmm copper conductor PVC insulated three core weather proof cable etc, fixing to wall/pole , complete all as specified and directed.
Note : (i) Contractor has to produce LM-79/LM-80 certificate alongwith purchase vouchers. | 10 | Each | - | - |
| 9 | Same as item No 8 above but 60 watts. | 10 | Each | - | - |
| 10 | S&F in replacement LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrossion resistant complete with driver and lamp die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting, with high power LED as light source of capacity 100 watts with suitable drivers etc and connecting with 4.0 Sqmm aluminium conductor PVC insulated twin core weather proof cable,Operation Voltage-120–270V AC, 50Hz etc, fixing to wall/pole complete all as specified and directed.
Note :
(i) Contractor has to produce LM-79/LM-80 certificate alonwith purchase vouchers and Guarantee certificate from Manufacturer. | 6 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
ParticularSpecification9085.pdf
Additional Documents • 0.96 MB
BOQ_877671.xls
BOQ • 1.21 MB
Credit9085.pdf
Additional Documents • 0.22 MB
Tender9085.pdf
Tender Documents • 0.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].