Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance C 5 156 YAMUNA VIHAR EAST DELHI DELHI 110053 | NORTH EAST DELHI | DELHI | 110053 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 1 GANESH DARSHAN ADV SURVE MARG SANDHURST ROAD W MUMBAI 9 | MUMBAI | MAHARASHTRA | Admitted-Finance |
Tender Value
₹24.5 L
Closing Date
13 May 2024, 3:00 pmClosed
SM E Z2
CETTM TRAINING CENTER
SITC of 1.0 TR/ 1.5 TR/ 2.0 TR High wall sleek model non Inverter Split AC Units for various Telephone Exchange in Z2 Areas under the jurisdiction of Senior Manager Elect Z2, MTNL, Mumbai.
2024_MTNL_805776_1
SM (E) Z2/NIT/24-25/04
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
180 days
CETTM TRAINING CENTER
AS per NIT
2 documents required · 2 mandatory
₹48,916
Yes
Accounts Officer CASH BW MTNL Mumbai
Yes
24 May 2024
2 May 2024
14 May 2024
2 May 2024
13 May 2024
2 May 2024
SITC of 1.0 TR High wall split Air Conditioning units having one indoor cooling unit & one out-door cooling unit both with copper tube cooling coil, with one cordless remote etc. complete as required and as per latest 3 (Three) star rating having latest EER . (Make- Carrier/ Voltas/ LG /Blue Star/ Hitachi/ O-General/ Daikin/Mitsubishi/ Samsung /Panasonic/ Toshiba)
SITC of 1.5 TR High wall split Air Conditioning units having one indoor cooling unit & one out-door cooling unit both with copper tube cooling coil, with one cordless remote etc. complete as required and as per latest 3 (Three) star rating having ERR latest (Make- Carrier/ Voltas/LG /Blue Star/Hitachi/O-General/ Daikin/Mitsubishi/ Samsung /Panasonic/ Toshiba
SITC of 2.0 TR High wall split Air Conditioning units having one indoor cooling unit & one out-door cooling unit both with copper tube cooling coil, with one cordless remote etc. complete as required and as per latest 3 (Three) star rating having latest ERR (Make- Carrier/ Voltas/LG /Blue Star/Hitachi/O-General/ Daikin/Mitsubishi/ Samsung /Panasonic/ Toshiba
Providing & fixing extra length of following including fixing arrangement (Beyond 4.0 mtrs) etc. complete as required.
a) Insulated refrigerant pipe (Suction and Discharge combined) suitable for 1.0 TR Split AC Unit.
b) Insulated refrigerant pipe (Suction and Discharge combined) suitable for 1.5 TR Split AC Unit.
c) Insulated refrigerant pipe (Suction and Discharge combined) suitable for 2.0 TR Split AC Unit.
d) 25 mm heavy duty rigid PVC pipe i/c accessories (Insulated) (ISI mark)
e) 25 mm heavy duty rigid PVC pipe i/c accessories (un- Insulated) (ISI mark)
f) connection cable ( as per company supply)
Supplying & fixing microprocessor-based AC controller with all accessories complete etc. as reqd. (M/s Presevi/ Powertech/ Mark & Space/ Vrinda Nano / Proton make)
a) Suitable for 2 split A/C units
b) Suitable for 1 to 3 split A/C units
c) Suitable for 4 to 6 split A/C units
d) Suitable for 7 to 9 split A/C units
Providing and fixing of suitable size of powder coated M.S. bracket for installing condenser (Outdoor) unit including proper size rubber pad and G.I. nuts & bolts etc. complete as required.
Providing & fixing M.S. stand made up of angle iron / flat / bar of suitable sizes for outdoor unit / cable tray including cutting, welding, drilling holes, painting &fixing arrangement complete as required.
Dismantling of existing Split AC unit including all its accessories like Indoor unit, Outdoor unit, Refrigeration piping, Drain piping, Power & Control cabling and stand etc. and shifting it to the store room or any other location in the same building premises and handover the same to building authorities completed as required.
Dismantling of existing Window AC unit including its all accessories and power & control cabling and stand etc. and shifting it to the store room or any other location of same building premises and handover the same to building authorities completed as required.
SITC of 1.5 TR Window Air conditioning unit having copper tube cooling coil with one cordless remote etc. complete as required. as per latest 3 (Three) star rating. (VOLTAS/ HITACHI/ BLUESTAR/ CARRIER/ ONIDA)
SITC of 2.0 TR Window Air conditioning unit having copper tube cooling coil with one cordless microprocessor unit etc. complete as required as per latest (Two) star rating. (VOLTAS/ HITACHI/ BLUESTAR/CARRIER/ ONIDA)
S/F 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying & laying of following size XLPE Copper Conductor armoured cable of 1.1 KV grade as per specification complete as reqd. (This item includes end terminations with brass compression Gland & heavy duty copper crimping lugs whre ever applicable)
a) 2x4 Sq mm with 1 no 14 gauge copper earthing wire
b) 4x6 Sq mm with 2 no 14 gauge copper earthing wire
Supplying of following size XLPE Aluminum Conductor armoured cable of 1.1 KV grade as per specification. (This item includes end terminations with brass compression Gland & heavy duty copper crimping lugs whre ever applicable) a) 4x10 Sq. mm 2 no 8 gauge al earthing wire
S/F of 6A to 32A rating 240/415V ,10 KA,"C" curve MCB suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc.as reqd
a) 6 to 32 amp SP
b) 6 to 32 Amp SP&N
c) 6 to 32 Amp DP
d) 6 to 32 Amp TP
e) 6 to 32 Amp TP&N
f) 63 A 4P MCB
g) 40 A TP MCB
h) 40 A TPN MCB
i) 63 A TP MCB
j) 63 A TPN MCB
ARCHY SERVICES PRIVATE LIMITED
M/s Om Vaishnav Technocrates
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .