Tender Value
₹26.5 L
EMD Value
₹53,000
Closing Date
10 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER ELG
13 conditions · 4 needing a document upload
The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days.
The following documents should be attached with the tender ( Annexure-V (A) certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. & Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder
Scanned copy of valid GST (Goods & Service Tax)Registration Certificate.
Partnership deeds, power of Attorney etc. (if any) : The tender shall clearly specify whether the tender is submitted on his own or on behalf of a partnership concern. If the tender is submitted on behalf of partnership concern he should submit the certified copy of the partnership deed along with the tender authorisation to sign the documents on behalf of the partnership firm. If these documents are not enclosed along with the tender document, the tender will be treated as hearing lease submitted by the individual signing the tender documents. The Railway will not consider any power of Attorney granted by the tender or any changes in the composition of the firm made subsequent to the execution of the contract. It may however recognize such power of Attorney and change after obtaining proper legal advice, the cost of which will be chargeable to the contract.(Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder. As per clause no. 14(e) of GCC'22, the following documents to be uploaded in terms of Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above.
Scanned copy of valid Trade license or Propitorship Certificate.
List of the Works completed in the last three financial years giving description of work. Organization for whom executed, approximate value of contract at the time of award, date of award and date of scheduled completion of work. Date of actual start, actual completion and date of payment and final value of contract should also be given. (Supportive documents/ certificates from the organization with whom worked/are working should be enclosed) (Please attach scanned copy of Annexure-I duly filled up).
List of works in hand indicating Supportive documents/certificates from the organization with whom worked/are working should be enclosed) description of work, contract value, approximate value of balance work yet to be done and date of award. (Supportive documents/certificates form the organization with whom worked/are working should be enclosed).(Please attach scanned copy of Annexure-IV duly filled up)
Railway Officers Associated with tenderer:RAILWAY OFFICERS ASSOCIATED WITH TENDERER 1. ExRailway Officer as tenderer: Should tenderer be a retired Gazetted Officer working before his retirement on any of the Railways owned and administered by the President of India, or should the tenderer being partnership firm have as one of its partners a retired Gazetted Officer as aforesaid, or should the tenderer being an incorporated company have any such retired Officer as one of its Directors, or should the tenderer have in his employment any retired Gazetted Officer as aforesaid, full information of such person shall be submitted along with his tender in the format given in annexure-VI to this chapter of this tender document. (Authority: ACS No.3 to GCC July,2014vide Boards letter No.2014/CEI/CT/O/9/RET dt.22.01.2015)(please attach scanned copy of Annexure-VI duly filled up by the firm).
Option for receiving payment through Letter of Credit . (Please attach scannedcopy of ANNEXURE 1 LC & ANNEXURE 2 LC duly filled up by the firm if optedfor)
The following documents should be attached with the tender: (i)Scanned copy of Pan Card. (ii)Scanned Copy of EFTMANDATE FORM Duly filled up by the bidder(iii)Tender Document (duly digitally signed by the bidder)
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The Contractor/(firm) must go through the entire tender document along with all attachment for any kind of guidance regarding execution of the job & payment there after. In case any thing is left out or not clear then they should consult the General Condition of Contract & standard Specification as attached (uploaded ).The bidders are also advised to preserve a copy of entire tender document/ (Set) for their convenience.
Electrical (General) work in connection with Installation of additional CCTV at HWH Station.
EL-HWH-25-21-3671~ER
EL-HWH-25-21-3671
Open
Works - General
180 Days
Howrah, West Bengal
₹0
₹53,000
20 Aug 2026
20 Aug 2026
27 Aug 2026
67 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 26,50,181 | ||
| — | — | — | Above/ 186000.00 Below/P | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos.single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phaseand neutral in GI conduit of suitable dia along with 1 no. singlecore HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ).( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 1500.00 | — | — | |
| — | — | — | Above/ 72500.00 Below/P | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. singlecore HRFR / FRLS grade, PVC insulated, copper conductor cableof size 2.5 sq.mm, 1100V grade for phase and neutral in GIconduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ).( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 500.00 | — | — | |
| — | — | — | Above/ 153000.00 Below/P | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 4 nos. singlecore HRFR / FRLS grade, PVC insulated, copper conductor cableof size 2.5 sq.mm, 1100V grade for three phases and one neutralin GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ).( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 1000.00 | — | — | |
| — | — | — | Above/ 375000.00 Below/P | ||
| Wiring of Mainline by 4 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 10 sq.mm, 1100V grade for 03 phases and 01 neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 500.00 | — | — | |
| — | — | — | Above/ 39450.00 Below/P | ||
| Supply of MCB DP, 40A, 1Ph, 240V, 50 Hz, 10kA with polycarbonate distribution box enclosure (IP-65) with polycarbonate transparent openable window including fixing, connection, testing and commissioning.( Make of MCB - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells )( Make of Enclosure - Grasp / OBO Bettermann / ABB / Schneider ) | — | 30.00 | — | — | |
| — | — | — | Above/ 76910.00 Below/P | ||
| Supply of Dust and vermin proof metal Busbar Chamber made of 16 SWG ( 1.6mm ) MS sheet duly powder coated consistingof 4 nos. tinned copper busbar of each bar of capacity 100 Amp.,4 way, suitable for 415V, 50Hz supply system including allaccessories alongwith fixing, connection, testing andcommissioning of incoming and outgoing cables glanding,cable socketing and connection with all suitable arrangement.( Make - Havells / Standard / HPL / C&S / LK (L&T) / Indoasian ) | — | 10.00 | — | — | |
| — | — | — | Above/ 58800.00 Below/P | ||
| Supply of MCCB with Thermal - Magnetic Release of breaking capacity 36 kA at 415V AC, 50Hz of capacity 25-32A / 32-40A / 40-50A, 4 Pole complete with metal enclosure with spreader terminals, LED indication lampsfor phases including fixing, connection, testing and commissioning.( Make of MCCB and Metal Enclosure - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) | — | 10.00 | — | — | |
| — | — | — | Above/ 50440.00 Below/P | ||
| Supply of SPN DB ( Metal Enclosure with Metal Door ), 8 way, 50Hz, complete with 4 nos. SP MCB of current rating from6A to 32A, 10kA, 240V, 50Hz as per requirement of load and1 no. DP RCBO of current rating 40A, 300mA, 10kA, 230V,50Hz ( Make of MCB, RCBO and Metal Distribution Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells ) | — | 10.00 | — | — | |
| — | — | — | Above/ 1210.00 Below/P | ||
| Fixing, connection and commissioning of above SPN MCB DBwith suitable arrangement including all incoming and outgoingcable connection with suitable cable termination arrangement. | — | 10.00 | — | — | |
| — | — | — | Above/ 127184.00 Below/P | ||
| Supply of TPN MCB DB ( Heavy duty, Outdoor type, UV rayprotected, self fire- extinguishing and resistant to abnormal heat and fire up to 650 degree C GWT, shock resistance IK08 or above and IP65 degree of protection grade transparent DB box, similar to ABB Mistral65 - 20 Modulesor equivalent ), 3Ph, 50Hz, 415V, 4 way per phase, 415V, 50Hz, complete with total 12 nos. SP MCB of current rating from 6A to 32A, 10 kA, 240 Volt, 50Hz per phase as per requirement of load and one no. FP RCBO 63A, 300mA, 10 kA, 415V, 50Hz, Suitable for AC + Pulsating DC (Type A) + Harmonics ( Make of MCB & RCBO - LK (L&T) / Siemens / ABB / HagerLegrand / Schneider ) ( Make of TPN DB - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / Spelsberg / Hensel / Eaton ) | — | 8.00 | — | — | |
| — | — | — | Above/ 1096.00 Below/P | ||
| Fixing, connection, testing and commissioning of above TPNMCB DB including all incoming and outgoing cables glanding, cableconnection with cable termination and suitable wall hanging arrangement as per site condition with all associated accessories. | — | 8.00 | — | — | |
| — | — | — | Above/ 76000.00 Below/P | ||
| Trenching and laying of cable under ground by soil cutting with covering of cable through suitable dia HDPE pipe includingsupply of HDPE pipe (PE-100 grade, PN-10 or higher) alongwith refiling of trench by excavated soil and make good of surface asits original condition. ( Cable will be supplied by Railway ) | — | 500.00 | — | — | |
| — | — | — | Above/ 40000.00 Below/P | ||
| Drawing of cable on wall / structure with suitable size and shapeGI clamps including supply of suitable size GI Clamp and GI nut-bolts and commissioning of cable( Cable will be supplied by Railway ) | — | 1000.00 | — | — | |
| — | — | — | Above/ 11900.00 Below/P | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable alongwith makegood of floor surface as its original condition after laying of cable( Cable will be supplied by Railway ) | — | 140.00 | — | — | |
| — | — | — | Above/ 35150.00 Below/P | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable through 80mm dia GI pipe including supply of GI pipe alongwith make goodof floor surface as its original condition after laying of cable( Cable will be supplied by Railway ) | — | 50.00 | — | — | |
| — | — | — | Above/ 30900.00 Below/P | ||
| Trenching, laying under road / track through 50 mm dia GIpipe ( medium gauge ) including supply of GI pipe and commi-ssioning of cable including back filling of trench with excavatedsoil after laying of cable ( Cable will be supplied by Railway ) | — | 150.00 | — | — | |
| — | — | — | Above/ 240000.00 Below/P | ||
| Laying of cable underground through 100 mm diameterHDPE pipe by Micro Tunneling cable laying method including supply and jointing of HDPE pipe (PE-100 grade, PN-10 or higher). ( Cable will be supplied by Railway ) | — | 160.00 | — | — | |
| — | — | — | Above/ 477120.00 Below/P | ||
| Supply of LT cubicle type outdoor wall / floor mounted Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder coated comprising with the following :a) MCCB with Microprocessor Release of breaking capacity36kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory, 7) Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication suitable for Release Range ( 63-160 ) Amp, 4 Pole - 1 no.b) MCCB with Microprocessor Release of breaking capacity 36kA at 415V, AC 50Hz ( Ics = 100% Icu ) with above features in (a) for Release Range ( 25-63 ) Amp, 4 Pole - 2 nos.c) Tinned Copper Busbar ( 4 Bar ) each of capacity 200 Amps., 415V, 50 Hz - 1 setd) LED indication lamp for Phases and "ON & OFF" indication for operating status of breakers - 12 nos.e) Petty store like cable gland, socket, fuse etc. - 1 jobcomplete with all other accessories, internal wiring by single coreFRLS grade copper conductor cable of suitable size and 1100V grade along with fabrication work, cable glanding, socketing etc.( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) | — | 6.00 | — | — | |
| — | — | — | Above/ 23856.00 Below/P | ||
| Fixing, connection, testing and commissioning of above panelincluding all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories. | — | 6.00 | — | — | |
| — | — | — | Above/ 8760.00 Below/P | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos.single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phaseand neutral in PVC conduit / casing along with 1 no. singlecore HRFR / FRLS grade, PVC insulated, copper conductorcable of size 1.5 sq.mm, 1100V grade for Earth ContinuityConductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 30.00 | — | — | |
| — | — | — | Above/ 3260.00 Below/P | ||
| Wiring of 6A / 3 pin Plug board consisting with one plug socketand one 6A switch by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated,copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 20.00 | — | — | |
| — | — | — | Above/ 7700.00 Below/P | ||
| Wiring of 6/16A 3 pin Plug board consisting with one 16/6A 3 pin plug socket and one 16A switch by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casingalong with 1 no. single core HRFR / FRLS grade, PVC insulated,copper conductor cable of size 1.5 sq.mm, 1100V grade forEarth Continuity Conductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 20.00 | — | — | |
| — | — | — | Above/ 8520.00 Below/P | ||
| Wiring of Multi Plug board consisting with three nos. 6A / 5 pin plug socket, three nos. 6A switch, one no. 16A / 6 pin plug socket, one no. 16A switch, one no. 10A fuse kit-kat / MCB and one indicator ( Red ) by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated,copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 15.00 | — | — | |
| — | — | — | Above/ 23800.00 Below/P | ||
| Wiring of Submain by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated,copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 350.00 | — | — | |
| — | — | — | Above/ 12400.00 Below/P | ||
| Wiring of Mainline by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 6.0 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 100.00 | — | — | |
| — | — | — | Above/ 5185.00 Below/P | ||
| Extra cost for conceal wiring in respect to PVC conduit / casingfor light, fan, plug, power plug, multi-plug point etc. includingmake good of wall surface as its original condition | — | 85.00 | — | — | |
| — | — | — | Above/ 8550.00 Below/P | ||
| Extra cost for conceal wiring for main / submain with respect to PVC conduit / casing including make good of wall surface as its original condition | — | 450.00 | — | — | |
| — | — | — | Above/ 32340.00 Below/P | ||
| Extra cost involvement for modular switch, bell push, plug socket,fan regulator, USB point, TV socket etc. with other accessories( Make of Modular switch, socket, box, cover plate etc. - ABB /Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) ) | — | 330.00 | — | — | |
| — | — | — | Above/ 2120.00 Below/P | ||
| Designing of mounting layout, supply, installation, connection and commissioning of 20-22W LED batten (Type of LED - Surface Mounting Device ) tube with industrial grade constant current Driver ( Efficiency - Greater than 85% ) with short circuit protection, extruded aluminium housing and milky polycarbonate diffuser ( LEDchip make - Nichia, Osram, Seoul, Philips, Lumileds, Everlight, Avago,Cree, Lednium, APT Electronics & BridgeLux ), LED luminaire system efficacy - Greater than 120 Lumens per Watt @ 350mA drive current,Colour Temperature - 6500K (Cool white), CRI>80, SDCM<5, Driver Operating Voltage - 140-270 Volt AC, Surge Protection minimum 4KV, THD<10%, Driver HV Cut off @ 325V/440V (P2P) protection for8 hrs., Life span of LED chip Greater than 50000 burning hours, The Luminaire & Driver both should be of same make / brand and indivi- dually BIS approved with 60 months warranty including fixing withGI clamps made of GI flat of suitable size & GI nut-bolts.( Make : Philips (Signify) / Havells / Bajaj / Panasonic / Crompton / Jaquar / Lighting Technologies / Halonix ) | — | 10.00 | — | — | |
| — | — | — | Above/ 23600.00 Below/P | ||
| Supply of AC Wall Bracket Fan 400 mm sweep suitable for operation on 1Ph, 220- 240V, 50 Hz supply system includingfixing, connection and commissioning with GI clamps madeof GI flat of suitable size and GI Nut-Bolts on wall / structure. ( Make : Havells / Usha / Orient / Halonix / Atomberg / Crompton / Bajaj ) | — | 10.00 | — | — | |
| — | — | — | Above/ 20730.00 Below/P | ||
| Supply of BLDC Ceiling Fan of sweep 1200 mm, Air delivery range from 210 cubic metre per minute to 220 cubic metre perminute and input power consumption range from 26W to 32W ( Star Rating - 5 Star, Service Value - 6 & above cubic metre per minute per watt ) with copper winding and remote for speed control of fan suitable for operation on 1 Ph, 50Hz, 240V power supply system ( conform to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable with BIS certification ) with 60 Months warranty including fixing,connection, testing and commissioning of ceiling fan with suitableclamping arrangement & 'S' hook etc.( Make : Havells / Usha / Orient / Halonix / Atomberg / Crompton / Bajaj ) | — | 10.00 | — | — | |
| — | — | — | Above/ 12435.00 Below/P | ||
| Earthing with 2 nos.of 50 mm diametre, 3.0 metres long heavy gauge GI pipe ( Make - Tata / Jindal / Bansal ) including construction of earth pit and necessary earth connection from pit by suitable Galvanized Iron ( GI ) strip.( For details not covered in this specifications, IndianStandard Code of Practice for earthing IS : 3043 - 1987,Reaffirmed - 1996 should be followed ) | — | 5.00 | — | — | |
| — | — | — | Above/ 404265.00 Below/P | ||
| Goods & Services Tax ( at present @ 18% ) | Lumpsum 404265.00 | 1.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
3671clause.pdf
ATTACHMENT
Advancecorrectionslipsupto11.pdf Advance Correction Slip
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
HTLTstandardspecification.pdf
ATTACHMENT
TenderFormandAnnexuresnew.pdf Tender form and annexure
ATTACHMENT
TenderBooklet.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
TenderFormandAnnexuresnew.pdf
ATTACHMENT
Advancecorrectionslipsupto11.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].