Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹31.9 L+₹1.4 L (4.58%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹33.4 L+₹2.9 L (9.45%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹33.8 L+₹3.3 L (11.0%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-Finance Rejected | |
| 5 | L5₹34.8 L+₹4.3 L (14.2%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
29 Oct 2024, 6:00 pmClosed
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
REPAIR MAINT INTERNAL ELECTRIC SUPPLY SWITCHES, SOCKETS FITTINGS, DBs AND CERTAIN ALLIED WORKS OF JCDA CAPS AND DAV AND REPAIR MAINT OF UG CABLE LT DISTRIBUTIONS OF ELECT SUPPLY UG CABLES LT PANEL BOARDS AT CAMERO OFFICE COMPLEX AFRO
2024_MES_666830_2
GE/SP/TOKEN-25/2024-25
Open Tender
Civil Works
Item Rate
120 days
GE (AF) Subroto Park
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹70,000
Yes
23 Jan 2025
8 Oct 2024
31 Oct 2024
8 Oct 2024
29 Oct 2024
16 Oct 2024
Amount
Taking down carefully copper/aluminium point wiring( light ,fan, socket or power) complete, fitting such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. Complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with single core of FRLS PVC insulated unsheathed ISI marked 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20 mm including conduit fittings and accessories concealed in wall / ceiling wiring terminated in flush metal box alongwith outer cover plate for mounting modular/piano switch, socket and electronic regulator along with provn of earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded FRLS ISI marked copper conductor of size 1.5 sqmm all as specified and directed by Engr-in-Charge. For One light point controlled by one switch one way.
All as per srl item 2 above but for one ceiling fan / Exhaust fan point controlled by one switch regulator.
All as per item No 2 above but for one 3 pin 5 amps socket outlet on indipendent board with other switchs.
All as per item No 2 above but for one 3 pin 5 amps socket outlet on the same board with other switchs.
All as per item No 2 above but with 2.5 Sq mm cable for Independent one 3 pin 15 Amps socket outlet In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire.
M&L for point wiring for one light fitting / one fan point controled by one switch with 1.5 Sq mm PVC insulated copper conductor cable drawing in and including PVC Casing/capping or surface conduit with 1.5 Sq mm PVC insulated copper conductor cable for continuous earth wire connected to main earth dolly with 3mm thick plastic laminated sheet cover complete for one light point controlled by one switch complete all as specified and directed by Engineer in Charge.
All as per srl item 7 above but for one fan point controlled by one switch through regulator.
All as per srl item 7 above but for one 5 pin 5 amps socket outlet on the independent board.
All as per item No 7 above but for one 3 pin 5 amps socket outlet on the same board with other switchs.
All as per item No 7 above but with 2.5 Sqmm PVC insulated stranded copper conductor cable for one 3 pin 15 Amps socket outlet. In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire.
S&F in replacement Socket outlet 2 in 1, 3 pin,6 A, 240 volts all as specified and directed by Eng-in-charge.
S&F in replacement switch piano, flush type single pole, one way, 16 Amps, 240 volts all as specified and directed by Eng-in-charge.
S&F in replacement socket 16 Amps, 2 in 1, flush type all as specified and directed by Eng-in-charge.
S & F Modular switch 1 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 6A - 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular switch 2 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F Modular switch 1 way 16A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 16A 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,3 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,4 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,6 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,8 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular metal flush box 3 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular metal flush box 4 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular metal flush box 6 module Complete all as specified and directed by Engineer-in-Charge.
S& F in replacement sub main wiring with two single core PVC insulated unsheathed cable 1100 volts FRLS grade with multi strand copper conductor and drawn through and including PVC conduit along with continuous earthing wire but in green colour complete on surface/concealed and connected to common earth dolly of the following size. Note : Three run of PVC cable and one run of PVC conduit shall be measured as one unit length. (a) 4 Sqmm ( 2 single run of 4 Sqmm and one run of 4 Sqmm as earth wire)
(b) 6 Sq.mm ( 2 single run of 6 Sqmm and one run of 6 Sqmm as earth wire)
(c) 10 Sq.mm ( 3 single run of 10 Sqmm and one run of 10 Sqmm as earth wire)
Supply & fix in replacement of Casing capping double lock type supper quality size 20 mm width ISI marked with fixing accessories complete all as specified and directed by Engineer in Charge.
Taking down of LED/Tube light fitting of any type of make and removing material to store for keeping in safe costudy or for reuse or taking credit and making good distrub surface of walls,floor etc complete all as specified and directed by the Engineer- In- Charge.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply, Laying, Testing and connecting cable XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade cross section area of 400 sqmm x 3.5 core copmlete all as directed by engineer-in-charge.
S&F in replacement of MCCB 250 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 35 KA.
S&F in replacement of MCCB 200 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 35 KA.
S&F in replacement of MCCB 125 Amps 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 25 KA.
Excavation in trenches in hard and dense soil n exc 1.5 mtr wide and n.exc 1.5 mtr in depth for laying of pipe,foundation for poles, stay, laying cables etc and getting out copmlete all as directed by engineer-in-charge.
Returning filling in including spreading, leveling watering and well ramming in layers n. exc 25 cm in hard/dense soil copmlete all as directed by engineer-in-charge..
Removing excavated material n.exc 50 meters and depositing where directed at a level n.exc 1.5 meter above the starting point copmlete all as directed by engineer-in-charge.
M&L for Sand cushioning of cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable copmlete all as directed by engineer-in-charge.
Supply and laying well burnt sub class ‘B’ bricks old size as mechanical protection to under ground cables laying across the cable copmlete all as directed by engineer-in-charge.
Supply and fixing load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting TPN 12way 415 volts 250 Amps rated bus bar and stove enamels dust and vermin proof suitable for FP 'A' frame MCCB of 250 Amps =01 No and MCB for outgoing comlete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement of fixed thermal and fixed magnetic settings, 4 pole MCCB 100 Amps, 50 HZ, 415 volts with rupturing capacity 36 KA complete all as specified and directed by Engineer-in-charge.
Supply and fixing load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting TPN 4 way 415 volts 250 Amps rated bus bar and stove enamels dust and vermin proof suitable for FP 'A' frame MCCB of 250 Amps =01 No and MCB for outgoing comlete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 4 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing 415V 10KA 'C' curve TPN 16 To 32 AMP miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Taking down unserviceable SP/SPN MCBs of any capacities from the MCCB DBs /MCB DBs after disconnecting the electric supply,complete all as specified.
S&F MCB SP 5 to 32 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
S&F MCB SPN 40 Amps 10 KA, 240 volt 50 Hz 'C' Series all as specified and directed by engineer-in-charge.
Supply & fix in replacement of flood light 50 watt, high power LED 3000/6000K energy saving, Highly efficient integral type mid power made of pressure die cast aluminium housing with 10 KV SPD, toughned glass, w/o Lens.IP66, suitable for highlighting architectural features orretail spaces complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement of LED Security Light 45 watt, LUMOS-SUPER Highly LED street light made of pressure dia cast aluminium housing with high power LEDs, lens & toughened glass, IP66, light distribution Efficacy>110Lm/W. 5700K. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V .
M& L for minor repair/service and greasing of bearings, cleaning of dust on ceiling fans with blades and canopys and reconnecting the electrical conections and with regulators complete all as specified and as directed by Engineer-in-Charge. Note: All required Materials are deemed to be included in the unit rate quoted.
M & L for repair to Ceiling fan of of any size by replacing unserviceable ball bearing of suitable size including neccessary greasing complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core comlete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MS cable tray Mild steel of size 300x50MM perforated cable tray for industrai use of size 3MM thicker rectangular with polished finishing and galvonaised coating with all connecting accessories requied at site with proper fixing/finishing completed all as specified and as directed by Engineer-in-Charge. .
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron strip 4 mm dia as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
M&L in replacement of earth contuinity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanized iron or steel wire complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement ceiling roses, surface bakelite 65x50mm ,3 terminals 3 phase, PVC/Polycarbonate, isolated body all as specified and directed at site.
M&L for locating fault in LT/HT (1.1/11 KV grade) underground cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. Excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 400 Sqmm 3.5 core/ 300 sq mm 3 core. The fault locating equipment will be brought to site within 02 hours of instruction received from Engineer-in-Charge complete all as specified and as directed by the Engineer-In- Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 185 to 240 sqmm,Indoor/Outdoor type
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 300 to 400 sqmm,Indoor/Outdoor type
S&F in replacement switch piano, flush type single pole, one way, 5 Amps, 240 volts all as specified and directed by Eng-in-charge.
S & F MCCB 4 Pole, 415 V, with Microprocessor release 400 Amps with breaking capacity 36 KA complete all as specified and directed complete all as specified and directed.
Supply, Laying, Testing and connecting cable XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade cross section area of 300 sqmm x 3.5 core copmlete all as directed by engineer-in-charge.
Supply, Laying, Testing and connecting cable XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade cross section area of 185 sqmm x 3.5 core copmlete all as directed by engineer-in-charge.
Supply and laying GI pipe light grade galvanized with all fittings laid in trenches or fix on wall for cable protection of 80 mm bore copmlete all as directed by engineer-in-charge.
M& L for Fabricating, supply and installing cubicle type, CPRI approved LT panel board,outdoor type, totally enclosed,dust & vermin proof (protection class IP 65) front opening with self locking arrangement made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 400 Amp capacity copper bus bar, wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected accessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etc including supply and fixing following accessories : Incoming:- (a) MCCB, 4 pole, 400 amp current carrying capacity, 50 Hz, 415 volt with rupturing capacity 36 KA - 01 No ( Incoming) (b) Digital type volt meter - set 01 (c) Digital type ammeter with suitable rating CTs conforms to relevent IS specification,- set 01 (d) LED type indicator lamp set of red , yellow and blue - set 01 (e) Mannual 320 Amps change over Outgoings:- (a) MCCB 4 pole, 125 Amp current carrying capacity, 50 Hz, 415 volt with rupturing capacity 16 KA - 03 Nos (b) MCCB 4 pole, 100 Amp current carrying capacity, 50 Hz, 415 volt with rupturing capacity 16 KA - 03 Nos
M& L for Fabricate, supply and install cubicle type, CPRI approved panel board,outdoor type, totally enclosed,dust & vermin proof (protection class IP 65) front opening with self locking arrangment made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 800 amp capacity copper bus bar, wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected acessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etc including supply and fixing following acessories:- Incoming:- (a) ACB, 4 pole, 800 amp current carrying capacity, 50 Hz, 415 volt with rupturing capacity 50 KA - 01 (b) Digital type volt meter and Amp meter incl switch- set 01 Each (c) LED type indicator lamp set of red , yellow, and blue - set 01 (d) Bus bar chamber 800A four strip incl enclosure of suitable size-4 Nos (e) On load change over switch 800 Amps 4 pole - 1 set Outgoings:- (a) MCCB 4 pole, 315 Amp current carrying capacity, 50 Hz, 415 volt 36 KA - 02 Nos (b) MCCB 4 pole, 250 Amp current carrying capacity, 50 Hz, 415 volt 25 KA - 02 Nos
Supply and fixing load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting TPN 8 way 415 volts 250 Amps rated bus bar and stove enamels dust and vermin proof suitable for FP 'A' frame MCCB of 250 Amps =01 No and MCB for outgoing comlete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair/replacement of old poles with new designer poles for Garden/street light made of cast iron pole with galvinised steel tube in polyster/PU paint with bracket of 3.5 Mtr height double arm of make halonix model no HOP-CID-3.5M including cement concrete 1:2:4 type B1 for Foundations up of size 1'x1'x1' PCC from ground level with proper fixing arrangements such as Nut/bolts/washers over PCC work all as specified and directed by Engineer-in-Charge.
S&F in repair of sub main wiring with 2 single core 04 Sq mm PVC insulated unsheathed 1100 V grade copper conductor cable drawing in existing rigid non- metallic PVC/metallic conduit incl 4.0 Sq mm PVC insulated single core copper conductor cable for continuous earth wire.
S&F in repair of sub main wiring with 2 single core 06 Sq mm PVC insulated unsheathed 1100 V grade copper conductor cable drawing in existing rigid non metallic PVC conduit incl 6.0 Sq mm PVC insulated single core copper conductor cable for continuous earth wire.
S&F in repair of sub main wiring with 2 single core 10 Sq mm PVC insulated unsheathed 1100 V grade copper conductor cable drawing in and incl rigid non metallic PVC conduit 25 mm dia incl 10 Sq mm PVC insulated single core copper conductor cable for continuous earth wire.
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3mm copper strip complete all as specified and directed.
M/S MG GROUP (BID ID -3146353)
sheetal engineering (BID ID -3152319)
M/S ANIL KUMAR (BID ID -3152100)
M/S LADPURIA ENTERPRISES (BID ID -3147282)
J.P. Enterprises (BID ID -3146686)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .