Loading…
Loading…
Tender ID
Tender Value
Refer Docs
EMD Value
₹6,400
Closing Date
21 Mar 2026, 6:55 pmClosed
Staff Officer EnM Dhori Area
Staff Officer EnM Dhori Area
Electrical Wiring of Anpati Devi Saraswati Shishu Vidya Mandir, Phusro under Dhori (K) Colliery, Dhori Area.
2026_CCL_356350_1
GM(D)/SO(EnM)/NIT/25-26/30
Open Tender
Electrical and Maintenance Works
Item Rate
7 days
Staff Officer EnM Dhori Area
Please refer NIT
2 documents required · 2 mandatory
₹6,400
23 Mar 2026
11 Mar 2026
23 Mar 2026
12 Mar 2026
21 Mar 2026
12 Mar 2026
12 Mar 2026 - 14 Mar 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor singie core cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required: Group A a) Bulb point b) Tube point c) Fan point d) Exhaust point
Supplying and fixing metal box of 180 mm x 100 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outiet and 15/16 amps piano type switch, connection, painting etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutrai bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/isolator). : 2 + 4 way/ 6 way, double door.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker sultable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole & neutral.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicie panel, making connections, etc. as required. 63 Amp TP&N for controling campus light
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate as required.
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long with charcoal/ coke and salt as required.
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, singie core cable in surface/ recessed medium class PVC conduit as required. : 2 x 4 sq.mm + 1 x 4 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. : 2 x 2.5 sq.mm + 1 x 2.5 sq,mm earth wire
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 100 Amp TP&N for controi of building light
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing 32 Amp. ICTPN disconector witeh fitting in each building for control of electrical load seperately
Total impact of GST for the purpose of CTC
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.61 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.23 MB
BOQ_369190.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .