Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.9 LAccepted-AOC EAST VIVEKANANDA PALLY MANGAL PANDEY SARANI PO RABINDRA SARANI SILIGURI 734 006 WB | JALPAIGURI | WEST BENGAL | 734006 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹44.2 L+₹1.2 L (2.68%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹45.8 L+₹2.8 L (6.41%)Rejected-Finance DESHBANDHUPARA PO SILIGURI TOWN DIST DARJEELING PIN 734004 | JALPAIGURI | WEST BENGAL | 734004 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹46.5 L+₹3.4 L (7.91%)Rejected-Finance N A | NA | NA | 121004 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹47.3 L+₹4.3 L (9.93%)Rejected-Finance 00 BHUSAR FARM KE PASS K K PURI NANDANPURA JHANSI UTTAR PRADESH 284003 | JHANSI | UTTAR PRADESH | 284003 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
15 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Sukna
Garrison Engineer Sukna, Post-Simulbari, Dist.-Darjeeling, WB-734009
PERIODICAL SERVICES AND CONNECTED WORK AT BANA SINGH VIHAR MD ACCN IN U AREA INCLUDING REPAIR REPLACEMENT OF INTERNAL WIRING FITTINGS UNDER AGE BR I OF GE SUKNA
2024_MES_655149_1
GE Sukna/8671
Open Tender
Civil Works
Works
270 days
Sukna
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE Sukna
₹90,000
Yes
5 Nov 2024
24 May 2024
17 Jun 2024
24 May 2024
15 Jun 2024
7 Jun 2024
25 May 2024 - 15 Jun 2024
Amount
M&L for repair to broken/damaged RCC chajjas by making good with PCC 1:2:4 type B1 or rendering 15 mm thick in cement mortar 1:4 mixed with water proofing compound to top and sides and rendering 5 mm thick to soffits in cement mortar 1:3 including necessary form work, reinforcement duly welded if required including demolition of broken/loose PCC or taking down old plaster at any storey of building complete all as specified and as directed. (Note: Rate shall be included for necessary scaffolding and safety arrangement)
Supply only liquid water proofing compound ISI mark.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement using WPC compound complete all as specified and directed. Note:- WPC shall be measured and paid separately.
M&L preparation of old decorated wall surface and including applying one coat of oil bound distemper complete all as specified and directed.
M&L preparation of old decorated ceiling surface and including applying one coat of oil bound distemper complete all as specified and directed.
M&L preparation of old decorated wall surfaces and including applying one coat of cement base paint complete all as specified and directed.
M&L complete removal of existing treatment of old decorated wall surfaces and including applying two coats of oil emulsion distemper over a coat of alkali resistant primer over a thin layer of wall care putty to obtained smoothness of plastered surfaces complete all as specified and directed.
M&L complete removal of existing treatment of old decorated wall surfaces and including applying two coats of weather coat acrylic exterior emulsion paint over a coat of primer including all necessary scaffolding complete all as specified and directed. (Note: rate shall be included for necessary scaffolding and safety arrangement)
M&L for complete removal of existing treatment of old decorated wall surfaces by Vacuum based sanding machine, removal of nails etc & filling cracks / hole with putty, applying one coat of primer using auto roller and applying a thin layer of wall care putty and sanding the same by Vacuum based sanding machine till obtaining even and smooth finish and applying two coats of oil bound distemper by auto roller complete all as specified and directed as per manufacturers instructions. Note:-Multipurpose mixer shall be used for uniform and proper mixing of putty.
M&L for preparation of newly plastered surfaces of wall by Vacuum based sanding machine, applying one coat of primer using auto roller and applying a thin layer of thick wall care putty and sanding the same by Vacuum based sanding machine till obtaining even and smooth finish and applying two coats of oil bound distemper by auto roller complete all as specified and directed as per manufacturers instructions. Note:-Multipurpose mixer shall be used for uniform and proper mixing of putty.
M&L for preparation of newly plastered surfaces of wall by Vacuum based sanding machine, applying one coat of primer using auto roller and applying a thin layer of thick wall care putty and sanding the same by Vacuum based sanding machine till obtaining even and smooth finish and applying two coats of exterior weather coat paint using auto roller complete all as specified and directed as per manufacturers instructions. Note:-Multipurpose mixer shall be used for uniform and proper mixing of putty.
M&L for complete removal of existing treatment of old decorated wall surfaces by washing with jet washer machine, removal of nails etc & filling cracks / hole with putty, applying one coat of primer using auto roller and applying a thin layer of thick wall care putty and sanding the same by Vacuum based sanding machine till obtaining even and smooth finish and applying two coats of exterior weather coat paint using auto roller complete all as specified and directed as per manufacturers instructions. Note:-Multipurpose mixer shall be used for uniform and proper mixing of putty.
M&L preparation of old decorated wooden surfaces of any description, not otherwise described over 10 cm width or girth and including applying one coats of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coats of synthetic enamel paint complete all as specified and directed.
M&L preparation of old painted surfaces of CGI / PGI sheet surface exc. 10 cm width or girth in roof and including applying one coat of anti-corrosive paint complete all as specified and directed.
M&L writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high with synthetic enamel paint complete all as specified and directed.
S&F GI tubing light grade 40 mm dia for protection pipe along the wall to TPN DB for protection of cable if required complete all as specified and directed .
M&L point wiring with 1.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, modular plate and frame on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch, all necessary cutting chasing (as required) and making good the disturbed surfaces including finishes to match with adjacent surfaces and including taking down old unsv ones complete all as specified and directed.
All as per Sl. item No. 20.00 above but for one 5 / 6 Amps socket outlet point on independent board.
All as per Sl. item No. 20.00 above but for one 16 Amps socket outlet point on independent board with 2.5 sqmm cable and 2.5 sqmm earth wire
All as per Sl. item No. 20.00 above but for one 5 / 6 Amps socket outlet point on same board.
All as per Sl. item No. 20 above but for one light point controlled by two, 2 - way switches.
M&L in replacement point wiring with 1.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including PVC casing caping (double lock pattern) and accessories on wall / ceiling surfaces etc. with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc including all other fixing accessories for one light / fan / exhaust fan point controlled by one 5 / 6 Amps switch complete all as specified and directed.
All as per Sl. item No. 25 above but for one 3 / 5 Amps socket outlet point on independent board.
All as per item No. 25.00 here-in-before but one 3 pin socket outlet / 5 amps on the independent board with other switches, with cables 2.5 sqmm size complete all as specified and directed
All as per Sl. item No. 25.00 above but for one 3 / 5 Amps socket outlet point on the same board.
All as per Sl. item No. 25.00 above but for one light point controlled by two, 2 - way switches complete all as specified and directed
M & L concealed sub main wiring with 2 runs of 2.5 sqmm main wire along with 1 run of 2.5 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the disturbed surfaces including finishes to match with adjacent surfaces and including taking down complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
M & L concealed sub main wiring with 2 runs of 4 sqmm main wire along with 1 run of 4 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the disturbed surfaces including finishes to match with adjacent surfaces and including taking down complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
M & L concealed sub main wiring with 2 runs of 6 sqmm main wire along with 1 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the disturbed surfaces including finishes to match with adjacent surfaces and including taking down complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
M & L in replacement for sub main wiring with 2 runs of 2.5 sqmm main wire alongwith 1 run of 2.5 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade copper conductor cable, drawn through and including adequate size PVC casing caping (double lock pattern) with all fittings & accessories on walls / ceiling surfaces etc., complete all as specified and directed. NOTE :- Two runs of main copper conductor, one run of earth wire and one run of PVC casing caping shall be measured as one unit length.
M & L in replacement for sub main wiring with 2 runs of 4.0 sqmm main wire alongwith 1 run of 4.0 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade copper conductor cable, drawn through and including adequate size PVC casing caping (double lock pattern) with all fittings & accessories on walls / ceiling surfaces etc., complete all as specified and directed. NOTE :- Two runs of main copper conductor, one run of earth wire and one run of PVC casing caping shall be measured as one unit length.
All as per item No. 34 above but with 2 runs of 6.0 Sqmm main wire along with 1 run of 6.0 Sqmm earth wire.
S&F of rigid non-metallic PVC conduit 20mm inclusive of tees, bends, elbow, reducer and fixing accessories concelled on wall including necessary cutting / chasing of wall and making good distub surface complete all as specified and as directed.
S&F in repairs switch piano flush type one way, 5 / 6 Amps, 240 volt complete all as specified and directed.
S&F in repairs Switch piano 5 Amps single pole two way complete all as specified and directed.
S&F in repairs switch piano modular type one way, 5 / 6 Amps, 240 volt complete all as specified and directed.
S&F in repairs switch piano modular type one way, 15 /16 Amps independent, 240 volt complete all as specified and directed.
S & F in repairs Switch Socket combination 16 Amps 3 pin flush type complete all as specified and as directed.
S & F in repairs Socket outlet 5 Amps 3 pin flush type complete all as specified and as directed.
S&F in repairs socket outlet modular type 3 pin 5 / 6 Amps, 240 volts combined 2 modular complete all as specified and directed.
S&F in repairs socket outlet modular type 3 pin 15/16 Amps, 240 volts combined 2 modular complete all as specified and directed.
S&F MCB SPN 40 Amp, 10 kA, 240V 'C' curve including taking down complete all as specified and as directed.
S&F MCB SP 6 to 32 Amp, 10 kA, 240V 'C' curve including taking down complete all as specified and as directed.
S&F ceiling rose, 3 phase / PVC / polycarbonate isolated body complete all as specified and directed.
S&F modular type electronic fan regulator, flush type 230V, AC 50 Hz not less than 100 Watt complete all as specified and directed.
S&F lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings including taking down old unsv ones complete all as specified and as directed.
S&F MCB DB, SPN 12 way, IP-43, IK09, double door, metal door type, with 100A copper neutral and earth bus bar for fixing MCB including taking down, fixed flush to wall & making good the disturbed surfaces complete all as specified and directed.
S&F VTPN DB, 4 way, IP-43, IK 09, single door type with metal door, with 250 A copper neutral and earth bus bar, suitable for fixing upto 160 Amp MCCBs as incomer fixing DPX 250+12 flush to wall & making good the disturbed surfaces complete all as specified and as directed.
S&F MCCB 4 pole 125 Amps breaking capacity 25 KA, type DU 250 C, Ics = 100% Icu including spreader link & taking down complete all as specified and directed.
S &F Bell buzzer, Ding Dong AC. 230 volts, single pole completed all as specified and directed.
M &L of Earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connected using galvanised iron earth lead wire 4 Sqmm as earthing electrode by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe (medium grade) and other end connected to earthing test point as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth up to a distance not exceeding 50 Mtr etc all as shown on electrical plate No. 5 of MES Schedule Part-I complete including testing on completion. On testing after completion if the desired earth resistance is not obtained the earthing will be made again by the contractor at no additional cost and including dimantling complete all as specified and directed.
S&F Exhaust fan 250 mm sweep, non metallic plastic body, AC single phase, 230 V, 50Hz with & including self closing louvers, nuts, screws, bolts of specified sizes, electrical connection with twisted three core PVC insulated unsheathed flexible cord of size 0.75 sqmm copper conductor from ceiling rose to exhaust fan and writing MES number in 2 cm height with synthetic enamel paint and cutting wall for making hole awriting MES number in 2 cm height with synthetic enamel paint and cutting wall for making hole and making good the disturbed surface to match the existing surface complete all as specified and directed. Note: The quoted rate is including for taking down and depositing old fan to Mes store
S&F exhaust fan 300 mm sweep, metal body, 1200 RPM (minimum), AC single phase, 230 V, 50Hz with bird guard, nuts, screws, bolts including electrical connection, writing MES number in 2 cm height with synthetic enamel paint and cutting wall for making hole and making good the disturbed surface to match the existing surface complete all as specified and directed. Note :- The quoted rate is including for taking down and depositing old fan to MES store
M&L for cutting and making and enlarging existing hole for fixing of exhaust fan, nuts, bolts washer including plastering and make good the disturbed surface with the existing all as specified and directed.
S&F in repairs of energy saving BLDC ceiling fan complete with all connected accessories as specified below: - Input Power: - 26 watts with full speed and reduced power consumption with reduced speed technology. Voltage: - 90-300 V AC, 50Hz, single Phase. RPM: - 340 to 375 rpm Blades: - Decorated Sweep: - 1200 mm. Air delivery: - Not less than 210 CFM Colour: - Glow white/Toast Brown/Gloss Black/or others as approved by Engr-in-Charge Speed/power control: -Without Remote through existing regulator. Star rating: - BEE 5 Star Rating Warranty: - As specified by the manufacturer, contractor shall produce original warranty and test certificate from the manufacturer. Note :- The quoted rate is including for taking down and depositing old fan to Mes store
S&F Single pole and neutral enclosure witha two pin and earthplug and socket complete with Double pole MCB 20 A complete all as specified and as directed..
S & F Bell push, flush type, 5 Amps single pole complete all as specified and as directed.
S&F modular type Bell push 6 A, 1 module complete all as specified and directed.
S&F LED batten light fitting 1 x 10 watt inverter (backup) type, 230 Volts, suitable for surface mounting, lithium ion battery with minimum 4 hrs backup time, extruded polycarbonate housing & extruded polycarbonate diffuser, lumen efficacy 100 Lm/watt (minimum), colour temperature 6500K (minimum), CRI 80 (minimum), IP-20 (minimum), PF 0.90 (minimum), in-built surge protection 3.5 KV (minimum) inlcuding all fixing arragnement and electrically connecting from ceiling rose to light fitting & taking down complete all as specified and directed.
S&F in repairs LED battery backup inverter bulb of Lamp wattage: - 9 to 12 Watts, Battery: - Not less than 2200mAh or not less than 4 hrs backup,Efficeacy: - Not less than 110 Lm/Watt including taking down old unsv ones complete all as specified and directed.
S&F in repairs LED Bulk Head fitting 10 watt with Injection molded polycarbonate housing IP66, IK10, 3.5kV inbuilt surge protection, PF ≥0.95, total System Lumens not less than 1100 lm, 6500k CRI ≥ 80, Operating Voltage range 140 V - 270 V. complete all as specified and as directed.
S&F wall decorative light fitting made up of high grade engineering material, (up to 14 watt LED bulb can be use in this lamp) complete all as specified and dircted
S&F 09 watt LED bulb for fixing in decorative wall lights complete all as specified and directed.
S&F in repairs Surface and wall mounted LED batten 20 watt 4ft long with Aluminum extruded housing , high quality polycarbonate diffuser & integrated Electronic Driver with IP20, PF 0.95, Efficiency not less than 110 lm / W color temp 6500k CRI ≥ 80, Operating Voltage range 140 V - 270 V complete all as specified and directed.
S&F in repairs LED Street Light 20 watt made up of pressure die cast aluminiun housing with highly efficient LEDs and PC cover with integrated lens with IP66, IK07, System Lumen Efficasy ≥100 Lm/W, 5 kV Surge Voltage Protection,Operating Voltage range 140 V - 270 V and bracket suitable for street light made out of GI pipe light grade of 25 mm bore & 0.75 mtr length (minimum), bend to shape including 2 pairs of MS flat iron clamps made out of 40 x 5 mm MS flat, nuts, bolts & washers etc, & painting the bracket with two coat of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
N.S.ENTERPRISES (BID ID -3025545)
M/S B B CONSTRUCTION (BID ID -3029648)
M/S GLORIOUS CONSTRUCTION (BID ID -3029660)
A K ENTERPRISES (BID ID -3030156)
MS ESSCON (BID ID -3029552)
M/S G S ASSOCIATES (BID ID -3029832)
DAS AND GHOSH CONSTRUCTION (BID ID -3029802)
M/s T K Das (BID ID -3030052)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .