Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
12 Dec 2023, 6:00 pmClosed
Shri D S Dhurpate JE QS AND C
Military Engineer Services, Garrison Engineer (South) Ahmednagar - 414002
REPAIR / MAINT OF DG SETS AT WATER SUPPLY INSTALLATIONS AT ACC and S AND LT ELECTRIC SUPPLY, SECURITY LIGHTS, UG CABLES, LT POLES and MISC WORKS AT CQA(V) and DAD UNDER GE (SOUTH) AHMEDNAGAR
2023_MES_628292_1
8119/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Ahmednagar
Class D Cat b(i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹90,000
Yes
29 Dec 2023
14 Nov 2023
14 Dec 2023
14 Nov 2023
12 Dec 2023
28 Nov 2023
14 Nov 2023 - 21 Nov 2023
Amount
M&L for monthly 'A' Check inspection, maintenance and servicing DG sets, 125 KVA Capacity, Make : Kirloskar oil engines, Model 6R 1080TA, Location : AC Depot Pump House including alternator, electric panel board connection to DG set etc for smooth functioning and carrying out following maintanance as required at site all as specified and as directed. Notes: Items/ Spares required shall be measured and paid separately under respective item of BOQ. (i) Checking engine oil level and topping up as and when required. (ii) Checking and adjusting the belt for tension and replacement of belt if required. (iii) Checking of oil bath air cleaner level (iv) Checking of exhaust system for leakage (v) Draining of sediment from fuel filter and fuel tank (vi) Cleaning of air cleaner elements (vii) Checking engine alternator coupling, mounting bolts and alignment (viii) Tighting all nuts, bolts, in altenator terminal block (ix) Checking of alternator carbon brushes and connections in alternator (x) Checking and tightening of all connection in DC control wiring. (xi) Checking of all radiator rubber hoses for leakage and replacement if required. (xii) Checking and recording oil pressure, water and oil temperarute for smooth functioning. (xiii) Checking anti vibration mounting pads for any deformation. (xiv) Checking throttle linkage for smooth operation. (xv) Checking battery for cell test, electrolyte level, gravity and topping up to required level (xvi) Routine check / repair work of panel, switches, MCCBs, main switch, all contactors, engine control unit etc. (xvii) Checking of AMF panel, all electrical connections etc. (xviii) Checking of earthing resistance (xix) Cleaning of vegitation around the DG set up to 1.5 mtr area.
All as per serial item No 1 but DG set 100 KVA capacity, Make : Kirloskar Green, Model KG-225L, Location : New KLP Pump house
All as per serial item No 1 but DG set 160 KVA capacity, Make : Kirloskar oil engines, Model KG 160 SGIR250MAL, Location : New KLP Pump house
All as per serial item No 1 but DG set 160 KVA capacity, Make : Kirloskar oil engines, Model KG 160 SGIR250MAL, Location : Dhobhighat pump house
All as per serial item No 1 but DG set 160 KVA capacity, Make : Kirloskar oil engines, Model KG 160 SGIR250M, Location : Dhobhighat pump house
All as per serial item No 1 but DG set 200 KVA capacity, Make : Kirloskar, Modal KG 254M-1 Location :DAD complex
All as per serial item No 1 but DG set 320 KVA capacity, Make : Crompton Greaves Ltd, Model F-GIR 315 SB EKG-1049, Location : Bhinghar pump house
All as per serial item No 1 but DG set 320 KVA capacity, Make : Crompton Greaves Ltd, Model F-GIR 315 SB EKG-1049, Location : Bhingar pump house
M&L for 'B' Check once in Six month or 250 Hrs running whichever is earlier for DG sets of 125 KVA Capacity, Make : Kirloskar oil engines, Model 6R 1080TA, Location : AC Depot Pump House, Inspection, maintenance and serviceing including alternator, electric panel board connection to DG set etc for smooth functioning and carrying out following maintenance as per OEM instructions all asspecified and as directed. Notes: Items/ Spares including 'B' Check kit, coolent, lubricating oil required shall be measured and paid separately under respective item of BOQ. (i) Repeat the activities of 'Á' Check services (ii) Replacment of lubricant oil. (iii) Replacing lubricant oil filters element with O rings (iv) Replacing fuel filters element with O rings (v) Replacing air filter elements with O rings (vi) Replacing coolant.
All as per serial item No 9 but for DG set 100 KVA capacity, Make : Kirloskar Green, Model KG-225L, Location : New KLP Pump house
All as per serial item No 9 but for DG set 160 KVA capacity, Make : Kirloskar oil engines, Model KG 160 SGIR250MAL, Location : New KLP Pump house
All as per serial item No 9 but for DG set 160 KVA capacity, Make : Kirloskar oil engines, Model KG 160 SGIR250M, Location : Dhobhighat pump house
All as per serial item No 9 but for DG set 160 KVA capacity, Make : Kirloskar oil engines, Model KG 160 SGIR250M, Location : Dhobhighat pump house
All as per serial item No 9 but for DG set 200 KVA capacity, Make : Kirloskar, Modal KG 254M-1 Location :DAD complex
All as per serial item No 9 but for DG set 320 KVA capacity, Make : Crompton Greaves Ltd, Model F-GIR 315 SB EKG-1049, Location : Bhinghar pump house
All as per serial item No 9 but for DG set 320 KVA capacity, Make : Crompton Greaves Ltd, Model F-GIR 315 SB EKG-1049, Location : Bhinghar pump house
Supply only 'B' check kit for DG set 125 KVA capacity, Make : Kirloskar oil engines, Model 6R 1080TA, Location : AC Depot Pump House. Note : Quoted rate includes oil filters (1.00 Ltr/0.5 ltr), diesel filters and air filters inner and outer as recommended by OEM
All as per serial item No 17 but for DG set 100 KVA capacity, Make : Kirloskar Green, Model KG-225L, Location : New KLP Pump house
All as per serial item No 17 but for DG set 160 KVA capacity, Make : Kirloskar oil engines, Model KG 160 SGIR250MAL, Location : New KLP Pump house
All as per serial item No 17 but for DG set 160 KVA capacity, Make : Kirloskar oil engines, Model KG 160 SGIR250MAL, Location : Dhobhighat pump house
All as per serial item No 17 but for DG set 160 KVA capacity, Make : Kirloskar oil engines, Model KG 160 SGIR250M, Location : Dhobhighat pump house
All as per serial item No 17 but for DG set 200 KVA capacity, Make : Kirloskar, Modal KG 254M-1 Location :DAD complex
All as per serial item No 17 but for DG set 320 KVA capacity, Make : Crompton Greaves Ltd, Model F-GIR 315 SB EKG-1049, Location : Bhinghar pump house
All as per serial item No 17 but for DG set 320 KVA capacity, Make : Crompton Greaves Ltd, Model F-GIR 315 SB EKG-1049, Location : Bhinghar pump house
Supply & refiling coolent, K cool super plus 50-50 premix all as specified and as directed.
Supply & refiling battery water with electrolyte mix all as specified and as directed.
Supply & refiling engine oil 20 W 40 turbo synthetic superior quality engine oil all as specified and as directed.
S&F radiator hose pipe set with clamps suitable for DG set of capacity 100 /125 KVA all as specified and as directed.
S&F radiator hose pipe set with clamps suitable for DG set of capacity 160/200 KVA all as specified and as directed.
S&F radiator hose pipe set with clamps suitable for DG set of capacity 320 KVA all as specified and as directed.
S&F fan belt set suitable for 100/125 KVA all as specified and as directed.
S&F fan belt set suitable for 160/200 KVA all as specified and as directed.
S&F fan belt set suitable for 320 KVA all as specified and as directed.
S&F in replacement of battery lead with negative & positive brass terminals of suitable size and length of each lead all as specified and as directed.
Servicing & repair to self starter of DG set of 100 KVA to 320 KVA including replacement of parts such as washer, nut, bolts, bush, solonoid, rotor etc. assembling and testing complete all as directed by Engr-in-Charge.
S&F in replacement of battery 12V, 180 AH, maintenance free battery, 12 Volt initially charged with suitable size of copper leads and brass terminals complete all as specified and as directed. Make: Excide/ Amara Raja/ Luminous
M&L in repairs broken conopy door hinges of DG set of any capacity and make. Setting of conopy door, properly locking arrengement complete all as specified and as directed.
S&F in replacement of fuel level gauge of DG set as per existing make, model complete all as specified and as directed.
M&L for dismantling, transportation to workshop and back, opening, rewinding main winding assembly and refixing 100 to 320 KVA DG set alternater, three phase, 415 V, 50 Hz with super enameled copper wire of existing gauge and existing class insulation including superior quality varnishing, heating / drying coils, making connections from coil to terminal box, spray painting with two coats of synthetic enamel paint including repair/replacement of diode plates for neutral & phase and repair / replacement of AVR, connecting, testing and commissioning at site for satisfactorily operation as required all as specified and as directed.
S&F in replacement of alternator connection terminal block suitable for 100 to 320 KVA DG set alternetor as per existing sample complete all as specified and as directed.
M&L in replacement of battery stand frame of size 4 feet x 1.5 feet with height of 1 feet made of 50mm x 50mm x 6mm angle iron and support with flat iron of size 40mm x 6mm, duly painted with two coats of synthetic enamel paint over one coat of red oxide primer, 20 mm wooden plank on top to place 02 Nos batteries complete all as specified and as directed.
Dismantling, radiator assembly from the engine of 200 KVA DG set Make KIRLOSKAR Model 6 SL 9088T by disconnecting inlet and out let connections , overhauling/ servicing the radiator, clearing, removing blockages arresting leakages, assembling back including necessary welding brazing as required, refixing , reconnecting and testing for proper functioning all as specified and as directed.
All as per serial item No 42 but for 160 KVA DG set Make : KIRLOSKAR Model 6 SL 1500TA.
All as per serial item No 42 but DG set 160 KVA Capacity, Make : Crompton Greaves Ltd, Model SDAG 2210
All as per serial item No 42 but for 125 KVA DG set Make KIRLOSKAR Model 6 SL 9088T
All as per serial item No 42 but for 100 KVA DG set Make KIRLOSKAR Model 6 SL 9088T/Model No. KG100W52
S&F in repairs, fuel level indicator pipe white transparent including two jublee clamps, marking level with radiem paint/ tape complete all as specified and as directed
S&F in repairs, exhaust pipe white asbestos rope including removing old unservicable rope all as specified and as directed
S&F in repairs, MCCB, 3 Pole,400 Amps, capacity 50 Hz, 415 volts with rating 36 KA and connection with proper lugs all as specified and as directed
S&F in repairs, MCCB, 3 Pole 250 Amps, capacity 50 Hz, 415 volts with rating 36KA and connection with proper lugs all as specified and as directed
S&F in repairs, MCCB, 3 Pole 200 Amps, capacity 50 Hz, 415 volts with rating 36 KA and connection with proper lugs all as specified and as directed
S&F in repairs, MCCB, 3 Pole 160 Amps, capacity 50 Hz, 415 volts with rating 36 KA and connection with proper lugs all as specified and as directed
S&F in repairs, automatic voltage regulator Kit suitable for 100/125 KVA alternator including incoming and out going cable connection and tesring on completion all as specified and as directed
S&F in repairs, flexible love-joy coupling set with Nut/ Bolt and rubber bushes suitable for existing DG set including metal filling grinding, finishing to suit the site installation alinging for noise free function all as specified and as directed
S&F in repairs, rubber bushing/rubber spider of DG set coupling complete with Nut , bolt and washer all as per site requirement all as specified and as directed.
M&L in replacement of battery charger 12 V DC SMPS 10 Amp for AMF panel all as specified and as directed
Supply and topping up / replacement of insulating oil of stabilizer chamber with new insulating / transformer oil upto the required level in any type and capacity of the voltage stabilizer all as specified and as directed. Note : Insulating / transforemer oil brought by the contractor at site must be in seal packed in drum having ISI mark as per IS-335 / 1983. Make : Savita / Asian.
Repair / Servicing to voltage stabilizers 3 phase 4 wire system, 160 to 300 KVA by at site by opening carefully from top, taking out coils / connections, cleanig coils checking defective joints / soldering / jointing, re- assembling and testing on full load and making fully servicable including spray painting with supper enamelled paint of colour all as specified and as directed.
S&F in repairs, off load change over switch, 100 to 200 Amps, 4P,415V suitable for LT panel all as specified and as directed
S&F in repairs, off load change over switch, 250 to 400 Amps, 4P,415V suitable for LT panel all as specified and as directed
M&L for repair and replacment of unserviceable time switch accessories/ spares including reconnecting and testing complete all as specified and as directed. Note : - Spares/accessories required for replacement shall be measured and paid seperatly under respective items of BOQ.
S&F in repairs, time switch analog type, single phase, 230 Volts of rating 20 Amps all as specified and as directed.
S&F in repairs, contactor, 40 Amps, 4 pole, 415 volts fixing with existing box by suitable size of copper cable with suitable size of lugs all as specified and as directed.
S&F in repairs, contactor, 63 Amps, 4 pole, 415 volts fixing with existing box by suitable size of copper cable with suitable size of lugs all as specified and as directed.
S&F in repairs, MCB TPN 16-32 Amps, 415 Volts, 50 Hz, 'C' series, AC supply system all as specified and as directed.
S&F in repairs, MCB TPN 40-100 Amps, 415 Volts, 50 Hz 'C' series, AC supply system all as specified and as directed.
S&F in repairs, LED solar street light fitting, 40 watt including galvanised steel pole 100mm bore dia 5m long, embedded in and including PCC 1:2:4, type B2 concrete, in built,lithium ion battery 24 AH 12.8V,solar panel 100 W ,charge controller with disk down sensor, excavation and earthwork complete all as specified and as directed. Make of LED solar street light fitting : Luker Cat Part No : LSTPSOLO40 or equivalent model of make Philips / GE/ Crompton/ Havells/Century LED/ Halonix/ SYSKA
M&L in repairs/replacement of battery charger, 24 V DC SMPS 10 Amp for AMF panel all as specified and as directed.
Excavation in trenches n, exc,1.5 m wide and n, exc,1.5 m in depth for laying of cable, foundation of pole/stay and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in excavated soil, including spreading, levelling, watering and well ramming in layers n,exc.25cm thick all as specified and as directed.
Removing excavated soil to distance n, exc 50 m and depositing where directed at a level n,exc.1.5 m above the starting point complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 240 Sqmm, 3.5 core with XLPE insulated stranded aluminium conductor including cable gland, lugs, testing and commissioning including taking out existing cable alongwith protection covers complete all as specified and as directed.
All as per serial item No 72 but cable of size 185 sq mm, 3.5 core.
All as per serial item No 72 but cable of size 120 sq mm, 3.5 core.
All as per serial item No 72 but cable of size 95 sq mm, 3.5 core.
All as per serial item No 72 but cable of size 70 sq mm, 3.5 core.
All as per serial item No 72 but cable of size 50 sq mm, 3.5 core.
All as per serial item No 72 but cable of size 25 sq mm, 3.5 core.
All as per serial item No 72 but cable of size 10 sq mm, 2 core.
M&L in repairs for straight through cable jointing kit, heat shrinkable for 1.1 KV grade, 25 to 50 sqmm 3.5 core XLPE cable with jointing material and accessories and testing after jointing all as specified and as directed.
All as per serial item No 80 but for 70 to 120 sqmm, 3.5 core XLPE cable
S&F in repairs, 50 mm bore dia GI pipe, light grade, laid in trenches / fixed to Pole / wall for cable protection complete all as specified and as directed.
S&F in repairs, 80 mm bore dia GI pipe, light grade, laid in trenches / fixed to Pole / wall for cable protection complete all as specified and as directed.
Supply and lay DWC HDPE PIPE (PE 100,SDR-21,6 Kgf/Sqcm) IS 4984-2016) 50mm dia for laying of LT cables etc complete with all accessories all as specified and as directed. Make: Vectus industries /Supreme /Infra /Astron Plastic.
Supply and lay DWC HDPE PIPE (PE 100,SDR-21,6 Kgf/Sqcm) IS 4984-2016) 63 mm dia for laying of LT cables etc complete with all accessories all as specified and as directed. Make : Vectus industries /Supreme /Infra /Astron Plastic.
Supply and lay DWC HDPE PIPE (PE 100,SDR-21,6 Kgf/Sqcm) IS 4984-2016) 110 mm dia for laying of LT cables etc complete with all accessories all as specified and as directed. Make : Vectus industries /Supreme /Infra/ Astron Plastic.
M&L for 2.5 sqmm 2 core, 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat stranded conductor including taking down old unserviceable cable all as specified and as directed.
All as per serial item No 87 but 10 sqmm, 2 core
All as per serial item No 87 but 6 sqmm, 2 core
All as per serial item No 87 but 4 sqmm, 2 core
S&F PVC insulated and over all PVC sheathed, stranded copper conductor wire, 1.5 sqmm x 3 core, ISI marked complete from fitting to pole junction box complete all as specified and as directed.
S&F in repairs, LED flood light fitting, 70 watt, 230V, AC, outdoor type with thermal management in multiple optics and equipped with IP65/66 protection with impact and corrosion resistant complete with driver and lamp all as specified and as directed.
S&F in repairs, LED street light fitting, 100 Watt, 230 Volt, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp, braket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and as directed.
S&F in repairs, LED street light fitting, 40Watt, 230 Volt, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp, braket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and as directed.
S&F in repairs, LED street light fitting, 60 Watt, 230 Volt, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp, braket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and as directed.
S&F in repairs, LED post top lantern, 20 watt, 230 Volt, AC with decorative post top 360 degree indirect light, IP 65 protection with impact and corrosion resistant complete all as specified and as directed.
S&F in repairs, 4 pole MCCB, 250 amps, 50 KA, 415 Volts, with adjustable type settings all as specified and as directed.
All as per serial item No 98 but MCCB 200 Amps, 36 KA
All as per serial item No 98 but MCCB 160 Amps, 36 KA
All as per serial item No 98 but MCCB 125 Amps, 25 KA
All as per serial item No 98 but MCCB 25 to 100 Amps, 25 KA
M&L for PCC 1:4:8, type D2, using 40 mm graded stone aggregates as in foundation of pole/stays all as specified and as directed.
M&L for PCC 1:3:6, type C1, using 20 mm graded stone aggregates as in coping of pole and similar work etc including necessary formwork and finishing even and smooth without using extra cement complete all as specified and as directed.
M&L for cutting/drilling hole under road for laying of U/G cable through pipe of suitable size complete all as specified and as directed.
S&F cross arms, bracings, support channel, back plate hooks etc fabricated from structural steel, sections (MS Channel) of required size and shape including nuts, bolts,washers, welding, bending, cutting cold or hot, drilling holes for inserting bolts as indicated and directed including painting with one coat of red oxide primer and two coats of silver aluminium paint including dismantling existing cross arms, MS channel or angle section complete all as specified and as directed.
S&F pin type porcelain vitreous brown/white insulator with approved make including one galvanised MS spindle two GI Washers and GI nut of size 100 mm height and 65 mm dia 1100 Volt grade including taking out old unserviceable insulator complete all as specfied and as directed
S&F shackle type, porcelain, vitreous, brown/white insulator of size 75 mm height, 90mm dia with approved make including galvanised MS strip of section 31 mm x 3 mm, insulated bolts 12mm dia, washers, nut etc for working pressure 1100 volt grade, including taking out of old unserviceable insulator complete all as directed.
S&F single disk assembly insulator, porcelain, vitreous, 145mm high and 225 mm dia, and socket type white, brown or green with all acessories including taking out of old unserviceable insulator complete all as specified and as directed.
Unbinding of the ACSR conductor from insulator on pole, pruning tree branches 3 mtr all arround conductor and restringing ACSR conductor of 2 to 6 conductors, tightening of OH Lines, binding to the insulators using required size of aluminium binding wire complete all as specified and as directed.
Labour and fault detector machine required for locating fault in underground cable, 11 KV by using fault detector machine including transportation and by carring out high pressure test all as specified and as directed.
Labour and fault detector machine required for locating fault in underground LT cable, 1100 volts by using fault detector machine including transportation and by carring out high pressure test all as specified and as directed.
Trimming/cutting of tree branches 3 mtr adjacent to the LT OH lines/street light feeder on both sides as per the direction of AGE E/M/JE incharge including removing the tree branches from site complete all as specified and as directed. Note : (i) Written shut down shall be obtained from concerned JE/AGE (E/M) before taking the trimming work in hand by contractor. (ii) Span from one pole to next pole (30 to 50 RM) will be considered as a one Job (iii) Any damage caused due to negligence of workmen will be rectified without any extra payment (iv) T & P such as ladder, rope, cutter, Axes and other related material will be provided by the contractor.
M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to GI earth wire 4 mm dia , by means of nut bolts, check nuts and washer, GI earth wire connected upto main earth point/DBs alongwith 15mm dia GI pipe, medium grade, including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4) cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion.
M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to the GI or steel earth strip 32 mm x 6 mm, by means of nut bolts, check nuts and washer of the GI . Earth wire connected upto main earth point/DBs alongwith 40mm dia GI protection pipe, light grade, including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4) cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion.
M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to the GI or steel earth strip 25 mm x 4 mm, by means of nut bolts, check nuts and washer of the GI . Earth wire connected upto main earth point/DBs alongwith 32mm dia GI protection pipe, light grade, including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4) cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion.
Dismantling old existing ACSR conductor of any type/size all as specified and directed.
Dismantling old existing GI earth wire of any size complete all as specified and directed.
Dismantling old existing MS cross arms of any type/shape all as specified and directed.
Dismantling old existing Insulators of any type/shape all as specified and directed.
M&L for aluminium conductor steel reinforced (ACSR), any size, (Weasel/Ferret/Squirrel as required) including stringing, binding, jointing, jumpering etc on insulators or on poles with minimum sag complete including dismantling ACSR conductor from LT/HT pole all as specified and as directed.
Dismanthing/taking down carefully the defective street light/security light/ floodlight fittings/ Post top lanterns of any description and servicing/ cleaning, checking connections, replacement of unserviceable spares, reassembling and refixing at its original location including reconnections and testing / commisssioning complete all as directed. Note: (i) Spares to be replaced shall be measured separately under relevant items of schedule. (ii) Cost of minor parts like screws, nut bolts, washers, pieces of wires and insulation tape etc required on site is deemed to be included in the quoted rates.
S&F in repairs, LED drivers for 20 W to 42 W LED panel lights/Post top /batten fittings any type and any make as per sample, all as specified and as directed.
S&F in repairs, LED Drivers for 34 W to 48 W LED panel lights any type and any make as per all as specified and as directed.
S&F in repairs, LED Drivers for 30 W to 50 W LED Security light fittings any type and any make as per sample, all as specified and as directed.
S&F in repairs, LED Drivers for 60 W to 90 W LED Security light fittings any type and any make as per all as specified and as directed.
S&F in repairs, LED Drivers for 70 W to 200 W LED Flood light fittings any type and any make as per sample, all as specified and as directed.
S&F in repairs, LED surge protectors for exisiting Size/Capacity LED fittings any type and any make as per sample, all as specified and as directed.
S&F in repairs, brackets made out of 40mm bore GI pipe, light grade, 1.5M long, bend to shape and including suitable MS clamps made out of 40 x 6mm flat iron, necessary bolts, nuts, washers etc complete and painting the bracket and clamps with 2 coats of synthetic enamel paint over a coat of red oxide zinc chromate primer all as specified and directed.
S&F PVC weather proof, hinged door, junction box with 10A Aluminium bus bar, 240V, Neutral link and 1No MCB SP of 6Amps, necessary fixing arrangement such as clamps, nut, bolts, etc including dismantling old unserviceable junction box all as specified and directed. Make : Sintex- Cat No. GSJB 2014 or equivalent as approved from list of makes specified in tender documents.
M&L for preparation of surface of steel tubuler poles including cross arms, channels, clamps, street light brackets and GI protection pipes etc which are fitted on pole, by scrapping and applying two coats of aluminium paint and marking pole Nos on each pole with red and black colour radium paint alternate strips, 15 cm in width of each strip upto 1 m from bottom of the pole all as specified and as directed.
M&L for scrapping old paints, preparation of surface of two pole structure including cross arms, channels, clamps etc and applying two coats of aluminium paint over a coat of red oxide primer and writing Pole No in black paint etc complete all as specified and as directed.
M&L for scrapping old paints, preparation of surface of four pole structure including cross arms, channels, clamps etc and applying two coats of aluminium paint over a coat of red oxide primer and writing Pole No in black paint etc complete all as specified and as directed.
Supply install in replacement and testing out door wheather proof bus bar chamber of size 100 cm x 60cm x 30cm made out of 3.15mm CRCA MS sheet having one side openable hinged door shutter with looking arangement/provn of two nos 80cm long 40x40x6mm anlge iron legs welded and 04 nos copper bus bar of 400Amp rating provn of one MCCB TPN 100 Amp 25 KA for controlling Electric supply complete erracted on ground with necessary PCC 1:3:6 type C2 foundation complete bus bar chamber painted with two coats of approved enamel paints over one coat of primer including making cable connection with necessary gland , lugs/thimbles all as specified and as directed.
S&F LT cable route indicator cast iron of suitable size with height of 1.5 metre along with LT cable trench including planting in ground with PCC complete all as specified and as directed.
S&F PVC insulated and over all PVC sheathed, stranded copper conductor wire 1.5 sqmm x 3 core ISI marked.complete from fitting to pole junction box complete all as specified.
Supply, install, testing and commissioning factory made and tested (including CPRI type test certified) LT Panel box (Design as approved by GE), outdoor type, floor mounted, compartmantalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 50x50x6mm angle iron 45 cm above ground and 45cm grounted in ground with PCC 1:2:4 Type B1 and coping 30cm above ground level,well Ventilated , powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement and including dismantling/ taking down old unserviceable LT feeder piller box , comprises of following. Incoming : (a) MCCB 200 amps, 4 pole, 36 KA, 415 volts grade, with thermal magnetic - 01 No (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 600 Amp, 4 pole, mounted on insulators for incomming supply - 01 Set. (c) digital Volt meter, 415 volts, 50 Hz AC supply -01 set. (d) digital Amp meter, 415 volts, 50 Hz AC supply -01 set. (e) Neon indicating lamps (R, Y & B) -01 Set. (f) Control MCB 1P 6 Amp - 04 No, (g) CT 200/5 - 04 No Outgoing : (a) MCCB 25 to 100 amps, 4 pole, 36 KA, 415 volts grade, with thermal magnetic - 05 No (b) digital Volt meter, 415 volts, 50 Hz AC supply -05 set. (c) digital Amp meter, 415 volts, 50 Hz AC supply -05 set. (d) Neon indicating lamps (R, Y & B) -05 Set.
M/s. Chhtrapati Construction(Propa. Lokesh Anant Salunke)
M/s. N D Karande
KAMINS CARE
ASHWAMEDH ENGINEERS
Maruti Abhiyantriki
BHAVIN INFRA
SKS Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .