Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAdmitted-Finance | ₹2.4 Cr | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | P M Construction Company L1 |
|---|---|---|---|---|
| 1.00 | Conducting Geo physical Resistivity electric survey for pin pointing of Tube well (2 point each tube well) | 3 | Each | 11,200 ₹33,600 Lowest |
| 2.00 | Supply, Erection, testing and commissioning of suitable size made out of 18 gause painted sheet canopy type out door LT panel board, (PMCC) conforming SLD and specification suitable for upto 10 HP submersible motor pump having following Items. Space for three phase electric meter with backalight sheet 6 mm thick, kit-kit fuse 32Amp.- 3 no., MCB 32Amp. 4 pole, Selector switch, Indicator lamp RYB, Amper mtr. (0-30) 100 mm size, volt meter ( 0-500) 100 mm size, Single phase preventer, Star-delta starter connection plat (63 Amp.), capacitor 4 KVAR etc. Make L&T complete including grouting the panel on MS angle frame above 60 cm height from ground level, construction suitable size RR stone masonry in (Cement motor 1:6) block on top of block CC 1:2:4 15cm thick for grouting the panel board. | 3 | Each | 29,300 ₹87,900 Lowest |
| 3.00 | Construction of RR stone masonry sluice valve chambers of following size wall thickness 45CM, bed concrete M-15 grade 15 CM, 25 CM thick internal & outer planter ferrow cement cover "AA" class loading. Internal size 1.20 x 1.50 Mtr. | 7 | Each | 24,300 ₹1,70,100 Lowest |
| 4.00Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: - a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. Rates for RCC Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4 | ||||
| 4.01 | 50 KL capacity | 50,000 | Liter | 8.66 ₹4,33,000 Lowest |
| 4.02 | 100 KL capacity | 1,00,000 | Liter | 8 ₹8,00,000 Lowest |
| 4.03 | 150 KL capacity | 1,50,000 | Liter | 7.02 ₹10,53,000 Lowest |
| 5.00 | Garden hydrant as per approved drawing and specification direction of Engineer-in-charge.
Hydrant having 25 mm dia GI pipe as per required hight upto 0.50 mtr. from gound level including supply and fixing of 25 mm dia half turn valve, M.S. saddle piece, rubber sheet & nut-bolt etc. from main supply line. | 47 | Each | 2,300 ₹1,08,100 Lowest |
| 6.00Providing, installation, testing and commissioning of submersible Monoblock pump set conforming to IS 8034 and 2 pole motor operating at synchronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fibre bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following poery, tools, and tackles required, construction of temporary works as | ||||
| 6.01 | 5.50 KW (7.50 HP) | 2 | Each | 58,100 ₹1,16,200 Lowest |
Tender Value
₹2.0 Cr
EMD Value
₹3.9 L
Closing Date
22 Jul 2024, 6:00 pmClosed
ACE -I
Additional Chief Engineer-I Rajasthan Hosing Board Jyto Nagar Janpath Jaipur
Water Supply Swerageand Rain Water Harvesting system for AIS Residency Phase-II at Sector-17 Pratap Nagar Jaipur
2024_RHBCE_398403_1
ACE-I-01/2024-25
Open Tender
Civil Works
Percentage
365 days
Pratap Nagar Jaipur
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,540
Yes
As Per NIT
₹3.9 L
Yes
2 Aug 2024
1 Jul 2024
25 Jul 2024
1 Jul 2024
22 Jul 2024
1 Jul 2024
Amount
Conducting Geo physical Resistivity electric survey for pin pointing of Tube well (2 point each tube well)
Construction of RR stone masonry sluice valve chambers of following size wall thickness 45CM, bed concrete M-15 grade 15 CM, 25 CM thick internal & outer planter ferrow cement cover "AA" class loading. Internal size 1.20 x 1.50 Mtr.
Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: - a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. Rates for RCC Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4
50 KL capacity
100 KL capacity
150 KL capacity
Garden hydrant as per approved drawing and specification direction of Engineer-in-charge. Hydrant having 25 mm dia GI pipe as per required hight upto 0.50 mtr. from gound level including supply and fixing of 25 mm dia half turn valve, M.S. saddle piece, rubber sheet & nut-bolt etc. from main supply line.
Providing, installation, testing and commissioning of submersible Monoblock pump set conforming to IS 8034 and 2 pole motor operating at synchronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fibre bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following poery, tools, and tackles required, construction of temporary works as
Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.
SITC STAR DELTA Starter type LT Panel of following rating: all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Backlight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle & Packing Material ) etc. and 100A/ 125A ,TPN, Aluminium Bus Bar with Colour coated heat shrinkage sleeves complete as per Technical Specifications and as per direction of Engineer-In-Charge.
Multigrade Sand Filter, NGMF-135, Design Flow Rate M3/Hrs 10, Max. Working Pressure Kg/Cm2 3.5, Min. working pressure Kg/Cm2 2.0 (1 W + 1 S)
Water softener, Design Flow rate M3/Hrs 10, Max. Flow rate M3/hrs 12, Max. Working Pressure Kg/Cm2 3.5, Min. wokring pressure Kg/Cm2 1.8, Resin Quality INDION 220 Na, Resin Quantity INDION 400, Design Hardness Ppm 250-300, Product hardness Ppm <10, OBR M3 50, Make ION Exchange (I) Ltd. (1 W + 1 S)
Rain water chamber 600 x 600 mm
Rain water chamber 750 x 600 mm
Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. Centrifugal Monoblock Pump set (Double Stage) 15.0 KW (20.0 HP)
Construction for RCC Sendimentation Tank (1800 x 1800 mm) of following size in all tyoe of soils with 150 mm thick RCC wall, basic of raft with 300 mm thick Dry stone soling, Under 100mm thick C.C. M10 grade norminal mix in foundation 20mm thick insider plaster with 1:4 Cement sand motor finished with floating neat cement, 150 mm thick RCC slab as per approved Drawing. This work including Earth work man hole cover rectangular shape 600 x 450 mm precast RCC manhole cover LD-25 etc. complete as per drawing & specifications including disposal of surplus earth within a lead of 50 mtr. Inside size 1800 X 1800 mm
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application : Principle : Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4- 20mA / Display: Integral display for programming and Display Reading / IP 66 0 - 8 MTR (At over head tank above building including all items)
Operation & Maintenance of water supply, sewer and rain water harvesting system including cost of required materials complete as per direction of engineer in charge for one year
Bidder Name
Amount
P M Construction Company (GSTN-08ABIPY8298F1ZR) BID ID -2867786
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.08 MB
BOQ_716712.xls
BOQ • 0.27 MB
cagr.pdf
Tender Documents • 2.59 MB
gs.pdf
Tender Documents • 0.49 MB
tbid.pdf
Tender Documents • 9.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .