Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC | L1 | Accepted-AOC Being First Lowest | |
| 2 | L2₹29.2 L+₹2.8 L (10.5%)Rejected-Finance | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹29.8 L+₹3.3 L (12.5%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L3 | Rejected-Finance Other Than First Lowest | |
| 4 | L4₹29.8 L+₹3.3 L (12.6%)Rejected-Finance | L4 | Rejected-Finance Other Than First Lowest | |
| 5 | L5₹31.0 L+₹4.5 L (17.1%)Rejected-Finance | L5 | Rejected-Finance Other Than First Lowest |
| Sl No | Description | Qty | Unit | M/s Karan Builders L2 | M/s Tarun Traders L1 | PAREEK AND COMPANY L3 | AJAY CONSTRUCTION COMPANY L6 | Dashmesh Construction Company L4 | GHANSHYAM BHADU L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position not otherwise specifically provided and removal of rubbish outside MOD land complete all as directed by Engineer-in-Charge. | 17.9 | Cum | 100 ₹1,790 Lowest | 200 ₹3,580 | 200 ₹3,580 | 200 ₹3,580 | 300 ₹5,370 | 250 ₹4,475 |
| 2.00 | Demolition of Cement Concrete (reinforced) of any description and in any position not otherwise specifically provided for and rubhish off from premises complete all as specified and directed by Engr-in-charge. | 0.75 | Cum | 400 ₹300 | 500 ₹375 | 300 ₹225 | 400 ₹300 | 250 ₹187.5 Lowest | 250 ₹187.5 Lowest |
| 3.00 | Demolition of brickwork or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stone work and precast concrete articles including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge. | 36.73 | Cum | 200 ₹7,346 Lowest | 250 ₹9,182.5 | 300 ₹11,019 | 200 ₹7,346 Lowest | 225 ₹8,264.25 | 250 ₹9,182.5 |
| 4.00 | M&L for old size brick work with sub class 'B' bricks straight or curved any radius built in cement mortar (1:4) all as specified & directed. | 35 | Cum | 4,200 ₹1,47,000 | 4,500 ₹1,57,500 | 3,500 ₹1,22,500 | 2,900 ₹1,01,500 Lowest | 4,400 ₹1,54,000 | 4,100 ₹1,43,500 |
| 5.00 | M&L for brick work with sub class 'B' bricks straight or curved on plan any radius half brick thick walls, built in cement mortar (1:4) all as specified & directed. | 15 | Sqm | 600 ₹9,000 | 800 ₹12,000 | 400 ₹6,000 | 350 ₹5,250 Lowest | 600 ₹9,000 | 550 ₹8,250 |
| 6.00 | Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified & directed. | 784 | Sqm | 10 ₹7,840 Lowest | 30 ₹23,520 | 10 ₹7,840 Lowest | 22 ₹17,248 | 15 ₹11,760 | 50 ₹39,200 |
| 7.00 | Material and labour for 7 to 8 mm thick non-skid ceramic colour (light shade) joint free tiles with matt finish premium quality having water absorption should be between 3% to 6%, square/ rectangular, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floor, set and jointed using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 including necessary cutting as per site requirement, complete all as specified and directed by Engineer-in-Charge. | 408.6 | Sqm | 900 ₹3,67,740 | 880 ₹3,59,568 Lowest | 950 ₹3,88,170 | 1,050 ₹4,29,030 | 900 ₹3,67,740 | 880 ₹3,59,568 Lowest |
| 8.00 | All as per Ser item No 07 but as in skriting, but tiles laid over and including 10 mm thick bedding layer in cement mortar(1:3) complete all as specified and directed by Engneer -in-Charge | 50 | Sqm | 900 ₹45,000 | 800 ₹40,000 Lowest | 900 ₹45,000 | 1,100 ₹55,000 | 900 ₹45,000 | 880 ₹44,000 |
| 9.00 | Material and labour for 7 to 8 mm thick non-skid ceramic colour (light shade) joint free tiles with matt finish premium quality having water absorption should be between 3% to 6%, square/ rectangular, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floor, set and jointed using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 including necessary cutting as per site requirement, complete all as specified and directed by Engineer-in-Charge. | 70 | Sqm | 800 ₹56,000 | 900 ₹63,000 | 900 ₹63,000 | 795 ₹55,650 | 850 ₹59,500 | 700 ₹49,000 Lowest |
| 10.00 | Material and labour for Providing and Laying Premium (1st) quality having water absorption should be between 10% to 20%, digitally printed straight edge, punched, glazed ceramic rectangle tile in approved shade and finish with flexural strength greater than 16 N/mm2, scratch hardness on Moh’s Scale minimum 3 and crazing resistance of 2 cycles in coloured tiles 600 X 300 mm and 7 mm thick, in any pattern of light & dark/highlighters tiles etc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified.
Note : Dado should be flushed with the wall plastering. | 240 | Sqm | 750 ₹1,80,000 | 650 ₹1,56,000 | 1,000 ₹2,40,000 | 975 ₹2,34,000 | 640 ₹1,53,600 Lowest | 700 ₹1,68,000 |
Tender Value
₹40.0 L
EMD Value
₹80,000
Closing Date
21 Oct 2025, 6:00 pmClosed
GE Lalgarh Jattan
GE Lalgarh Jattan
SPECIAL REPAIR TO BLDG NO P-06 (COOK HOUSE) OF OTM-II AT LGJ MIL STN
2025_MES_728975_2
8936-15/GE/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE Lalgarh Jattan
As per tender document
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹80,000
Yes
28 Nov 2025
7 Oct 2025
23 Oct 2025
7 Oct 2025
21 Oct 2025
14 Oct 2025
Amount
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position not otherwise specifically provided and removal of rubbish outside MOD land complete all as directed by Engineer-in-Charge.
Demolition of Cement Concrete (reinforced) of any description and in any position not otherwise specifically provided for and rubhish off from premises complete all as specified and directed by Engr-in-charge.
Demolition of brickwork or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stone work and precast concrete articles including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge.
M&L for old size brick work with sub class 'B' bricks straight or curved any radius built in cement mortar (1:4) all as specified & directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan any radius half brick thick walls, built in cement mortar (1:4) all as specified & directed.
Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified & directed.
Material and labour for 7 to 8 mm thick non-skid ceramic colour (light shade) joint free tiles with matt finish premium quality having water absorption should be between 3% to 6%, square/ rectangular, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floor, set and jointed using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 including necessary cutting as per site requirement, complete all as specified and directed by Engineer-in-Charge.
All as per Ser item No 07 but as in skriting, but tiles laid over and including 10 mm thick bedding layer in cement mortar(1:3) complete all as specified and directed by Engneer -in-Charge
Material and labour for 7 to 8 mm thick non-skid ceramic colour (light shade) joint free tiles with matt finish premium quality having water absorption should be between 3% to 6%, square/ rectangular, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floor, set and jointed using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 including necessary cutting as per site requirement, complete all as specified and directed by Engineer-in-Charge.
Material and labour for Providing and Laying Premium (1st) quality having water absorption should be between 10% to 20%, digitally printed straight edge, punched, glazed ceramic rectangle tile in approved shade and finish with flexural strength greater than 16 N/mm2, scratch hardness on Moh’s Scale minimum 3 and crazing resistance of 2 cycles in coloured tiles 600 X 300 mm and 7 mm thick, in any pattern of light & dark/highlighters tiles etc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified. Note : Dado should be flushed with the wall plastering.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and over 20 mm thick screed bed in CM 1 : 6 complete all as specified and directed by Engneer -in-Charge
Rounding off edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations all as specified and directed
Dismantling of Brick tiles in floor or roof laid dry and pointed in cement morter complete all as specified and as directed by engineer-in-Charge.
Demolition mud in roofs, any thickness, including plastering and leeping and including rubbish off the premises complete all as specified and directed.
M & L for 40 mm thick cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregate as in roof Padding etc and slope 1:40 mixed with water proofing coumpound as epr manufacturer instruction, finishing the surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Supply of SBR waterproofing compound @ 2% of per kg cement used complete all as speccified.
OVERLAY- PU BASED ELASTOMERIC LIQUIED MEMBRANE SYSTEM FOR EXPOSED ROOF : Providing and applying polyurethane liquid roof waterproofing with improved water ponding capability, thermal insulating lastomeric high build liquid membrane for concrete roofs for exterior wall and exposed surface with solid content not less than 80% and solar reflective index 109 as per (ASTM E1980-19)/tear strength ~20 N/mm (Free film, 14 days, +30 degree C) (ASTM D624) and tensile strength 2 N/mm2 (ASTM D4541). (a) After proper surface preparation, Apply one coat of Primer for PU coating as per manufacturers specification. (b) Apply 1st coat of Shali Urethane® BTD (white) @ 650 gm / m²(minimum) or equivalent by brush / roller while prime surface is tacky, Spread waterproofing reinforced Glass Fiber mash of 45 GSM with overlaps of 50 mm in both directions when the surface is still tacky. Allow 1st coat to dry. (c ) Apply 2nd & 3rd coat of Shali Urethane® BTD (white) @ 650 gm / m² (minimum) or equivalent by brush/roller. Note : (i) The Minimum dry film thickness (DFT) of roof treatment shall be 1.5mm if any shortfall in thickness of above treatment the same shall be achieved by additional coat. (ii) The procurement of material and execution of the work of water proofing treatment shall be carried out by authorised applicator approved by GE. (iii) The manufacturer/authorised applicator shall give a warranty for the performance & durability for 10 years.
M&L PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in roof kerbs or mud stops, and like rounded or chamfered on edges including necessary form work etc complete all as specified and directed by Engr-in-Charge.
Taking down cement plaster/terrazoo on brick/stone wall or concrete surfaces or ceiling including raking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick on brickwork or concrete surfaces in cement mortar 1:6 on wall, finished fair even and smooth without using extra cement all as specified and directed.
M&L for rendering 15mm thick on brickwork or concrete surfaces in cement mortar 1:4 on wall, finished fair even and smooth without using extra cement all as specified and directed.
M & L rendering 10 mm thick in cement mortar (1:3) on fair faces of concrete surfaces of ceiling finished fair and even without using extra cement complete all as specified & directed by Engr-in-charge.
M&L Prepration of New plastered Internal wall surface and applying the following :- (a) M&L wall care putty 1 mm thick on wall surface and smoothening the surfcae with sand papers / Mechanised sanding etc prepatory to paint as directed complete all as specified (b) M&L two coat of internal acrylic emulsion over a coat of primer priming by using Airless spray / Roller over complete all as specified Note : Contractor may use manual scraping tools for surface prepration with prior approval of Engr-in-charge in case of places where using of Mechanical equiment are not posiible
Material and labour for complete removal of existing treatment of any description on old wall surfaces of any description, preparation of surfaces by mechanized sander having suction vacuum bag using smart periodical methodology complete all as specified and applying 1.5 to 2.5 mm thick acyrlic wall care putty Two or more coats of 100% Premium exterior acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed by Engineer-in- charge.
M&L for preparation and applying three coat of white wash on newly plastered surface of ceiling etc with one kg of unslaked lime mixed with 4.00 ltr of water to make thin cream, screened after 24 hrs and mixing on kg of gum desolved in hot water per one cum of cream, 1.30 Kg of sodium cloride/10 Kg of lime and untramine @ 3.0 grms/Kg of lime complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of old decorated, plastered or pointed surfaces of ceiling by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots etc and applying two coat of white wash complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of new surface and applying one coat of 100% Premium weather proof exterior acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed by Engineer-in- charge.
Material and labour for complete removal of existing treatment of any description on old wall surfaces of any description, preparation by surface with help of mechanicaly complete all as specified and applying 1.5 to 2.5 mm thick acyrlic wall care putty Two or more coats of 100% Premium weather proof exterior acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed by Engineer-in- charge.
Formwork to chajjas, troughs and similar items including edges , for rough surface of concrete, complete all as specified and directed by Engineer-in-charge
M&L for reinforced cement concrete 1:1.5:3 type B0 using 12.5mm graded stone aggregrate in Chajjas; complete all as specified and directed by Engr-in-charge. Note : Reinforcement shall be measured and paid seperately.
S&F for TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as directed.
Taking down chowkhats or frames n.exc 1.5 sq. m each with shutters (without taking off shutters from the frame) complete all specified and directed directed.
Taking down chowkhats or frames exc 1.5 sq. m but n.exc 4.0 sq. m each with shutters (without taking off shutters from the frame) complete all specified and directed directed.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately)
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately)
S&F for Factory made single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of 35 mm thick size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. including supply and fixing following items :- (a) Stainless steel (304 Grade) Finished butt Hinges 100 mm, 4 Nos per leaf and table 6 of BIS 12817-2020 BIS Marked. (b) Stainless stell (304 Grade) finished square tower bold 200 mm long-2 Nos per leaf as per table 01 dia of bolt 12 mm as per BIS 12833. (c) Stainless steel (304 Grade) Finished Handles 200 mm-2 Nos per leaf. (d) Stainless steel (304 Grad) finished siliding bold 300 mm-1 No per leaf, 16 mm dia as per BIS clause (iii) of BIS 15834-2020. (e) Stainless steel (304 Grade) Finished Floor door stoper-1 Nos per leaf.
Supply & fixing HDHMR Board , 18/19mm thick both side decorative laminated, density over 850kg/cum, having a class A fire rating, grade 2 quality, interior grade, including continuous SS (304 grade) piano hinges with width of flap 30 mm, with lock and locking arrangement , stainless steel (304 grade) finished Handle 200 mm long-01 No on each shulter , L bend or necessary fittings to mount on wall or to frame work as in Kitchen cup board Shutter / shelves / cabinet etc complete all as per direction of Engineer- in-Charge
S & F in repair 30 mm wide flap when open mild steel, bright finish or electro galvanised Continuous (piano) hinges complete all as specified and directed.
Supply and fixing Magnetic catcher fixed with steel screw complete all as specified and as directed by Engineer-in-charge.
S&F 100 mm long butt hinge, extruded stainless steel with stain less steel hing pin, complete all as specified and directed by Engneer -in-Charge .
S&F for 300 mm long mild steel sliding door bolt type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
S & F 200 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed.
S & F 150 mm long Aluminum anodised bow handle fabricated type extruded section complete all as specified and directed.
S&F 300mm ordinary rat tail rod pattern springs including roller and roller plate complete mild steel fixed complete all as specified and directed.
S & F 2nd class hard wood (sal) or any other 2nd class hard wood articles not exc 200 Cubic Centimeter each Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labour etc complete all as specified
S& F in repairs stainless steel wire cloth 0.36 nominal dia of wire and average width of aparture 1.40mm and fixed with tinted tacks or stainless steel wire staples fixed to wooden/steel shutters complete all as specified and directed by Engr-in-charge.
S&F for powder coated aluminium frame for doors, windows, ventilators and aluminium partition with one or more rebates including jointing cleats glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete with locking arrangements for fixing with powder coating on aluminium sections, minimum thickness of poweder coating shall be 50 micron as per the specification. The top and bottom horizontal members and vertical members adjacent to wall shall be fixed with floor, ceiling, walls and cills where required and fixed with the help of rawl plugs and screws or with fixing clips or with expansion hold plate fastners. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically whereever required complete in all respect all as specified & directed by Engr-in-Charge.
S & F Powder coated anodised aluminium window and ventilator shutters, partiall fixed and partially 3 track sliding with out sash bars which are two shutter having tinted glass of 4.8 mm thick and 3rd is stainless steel wire cloth 0.63 mm normal dia of wire and average width of apertune 1.40 mm, aluminium sections weighing 0.55 kg/m (1.50 to 1.80 mm thick) including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified
S & F for Aluminium anodised (Powder coated) Three track sliding window frame with shutters (two glazed and one gauged shutter) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete and glazing with 5 mm thick tinted glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc with the following section of frame and shutter (A) Sections for frame (i) Top and verticals 92 x 29.50 x 1.30 mm thick (ii) Bottom 92 x 29.50 x 1.20 mm thick. (B) Sections for shutter (i) 'A' section 39 x 20 x 1.50 mm thick (ii) 'Interlock' section 39 x 20 x 1.50 mm thick(iii) 'H' section 41 x 20 x 1.10 mm thick Make: Jindal or equivalent sections of Hindalco.
S & F 4 mm thick figured glass, pin head secured with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed.
S&F for 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring all as directed.
M & L for preparation of old wooden surfaces of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Material & Labour for mild steel work conforming to Fe 290 (E-165) as in grills, gratings etc. with ends of bars shouldered and/ or rivetted or forged into spikes; framed guard bars, walkways, railing, framed work of water tanks and similar works complete all as directed by Engineer-in- charge
M & L for painting steel and iron surfaces of any discription,over 10 cm width or girth, with preparation of new or previously untreated surfaces priming with one coat of red oxide & finish with two coats of synthetic enamel paint ordinary tint all as specified and directed by Engr-in-Charge.
M&L for preparation of old steel surfaces of any description exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-charge.
Dismantiling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engineer-in-charge.
Supply only Galvanised mild steel plain wire 4 mm thick for hanging purpose of ceiling frame complete all as specified and directed by Engineer-in-charge.
Supply & fixing anodized aluminium snap grid framework for false ceiling, size of snap grid frame work 605 mm x 605 mm complete all as specified and as directed by Engineer in Charge .
M & L for 4 mm thick non asbestos cement 'E' board fibre building boards, fixed or laid/inserted to timber/GI/Aluminium frame work with screws complete all as specified and as directed by Engineer in Charge .
Supply and fixing stainless steel pipe 25mm bore (as a curtain rod), wall thickness of pipe not less than 1mm and grade SS 202, fixed in position with brackets and knobs at both ends as per site requirement including taking down old existing curtain rods any description with accessories complete all as specified and directed. Note : The cost of brackets and knobs is deemed to be included in the quoted rate. Nothing extra shall be paid on this account.
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with integral foot rests but including CI 'P' trap set in and including concrete fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC valve less, syphonic action type flushing cistern,10 ltrs capacity low level, white, with inlet ball valve, float, handle and telescopic pipe flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level cistern and connection to pipes all as directed.
S&F in repair vitreous china wash hand basin coloured Flat back of size 550x400mm, including 32mm dia chromium plated waste coupling long screwed shank and fly nut, flanged end bedded in red led cement and other end fixed and PVC waste pipe including cutting for and pinning in ends of brackets in CM 1:3 all as specified .
S&F in repairs 32 mm dia low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors complete all as specified and directed by Engineer-in-Charge.
S&F in repair bib tap 15mm bore cast copper alloy chromium plated long body fancy type with capston head and cup screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge.
S&F in repair CP brass stop/angle valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fixing 450 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
Dismantling of water tanks of capacity exc 500 and n.exc 1000 ltrs and removing from site all as specified and directed.
S&F for Rotational moulded polythene water storage tank 500 ltr capacity vertical with closed top, ISI marked hoisted and fixed in position connection nipple 2 Nos complete all as specified and directed..
S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore complete all as specified and directed
S&F in repair ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 20mm dia bore pipe complete all as specified and directed by Engr-in-charge.
Taking down 15 mm dia steel GI tubing including all connectious fittings in any position including cleaning for re fixing the serviceable pipe all as directed.
Taking down 20 mm dia steel GI tubing including all connectious fittings in any position including cleaning for re fixing the serviceable pipe all as directed.
Taking down 25 mm dia steel GI tubing including all connectious fittings in any position including cleaning for re fixing the serviceable pipe all as directed.
Supplying and laying of 20 mm (Outer dia) CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Supplying and laying of 25 mm (Outer dia) CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Supplying and laying of 32 mm (Outer dia) CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Dismantling of cast iron pipes, jointed in cement mortar and taking out of trenches/wall if required 75/100mm dia complete all as specified and directed by engineer-in-Charge.
Taking down eaves gutters and rainwater pipes/PVC SWR (any size or pattern) including all fittings, heads, shoes, bends, swan-necks etc.,complete all as specified and directed by Engineer-in-Charge. (measured overalll as fixed along the centre line over fittings and accessories)
S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls complete all as specified and directed by Engineer-in-Charge.
Supply & fixing 110mm bore UPVC pipes grade 'B' single socketed in any length with rubber ring joints, fixed along walls with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, joints fixed with pipe joint lubricant complete all as specified and as directed by Engineer-in- charge. Note:- Bracket, clamp, nut bolt, fastner, slotted channel etc shall be made of deep drawn low carbon steel material with hot dip zinc aluminium flake coated and fixed all as shown on BTD drawing cost for same shall deemed to be included in the quoted unit rate and nothing extra shall be admissible on this account. Note : UPVC pipe and fittings/fixture (i) The testing for leakage of pipe shall be done before connecting the pipes (ii) All pipes shall be minimum 4" away from walls fixed with GI bracket (iii) The gully trap shall be minimum 90 cm away from wall. (iv) Seperate pipes for each floor should be provided. (v) Sewage and drain system shall be seperate.
Supply & fixing 75 mm bore UPVC pipes grade 'B' single socketed in any length with rubber ring joints, fixed along walls with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, joints fixed with pipe joint lubricant complete all as specified and as directed by Engineer-in- charge. Note:- Bracket, clamp, nut bolt, fastner, slotted channel etc shall be made of deep drawn low carbon steel material with hot dip zinc aluminium flake coated and fixed all as shown on BTD drawing cost for same shall deemed to be included in the quoted unit rate and nothing extra shall be admissible on this account. Note : UPVC pipe and fittings/fixture (i) The testing for leakage of pipe shall be done before connecting the pipes (ii) All pipes shall be minimum 4" away from walls fixed with GI bracket (iii) The gully trap shall be minimum 90 cm away from wall. (iv) Seperate pipes for each floor should be provided. (v) Sewage and drain system shall be seperate.
Supply and fixing uPVC bends (any radius) grade 'B' suitable for 110 mm bore pipe competed all as specified and as directed by Engineer-in-charge
Supply & fixing uPVC bends (any radius) grade 'B' suitable for 75 mm bore pipe competed all as specified and as directed by Engineer-in-charge
Supply & fixing uPVC junction (double T/sockets) grade 'B' equal or unequal suitable for 110 mm bore pipe competed all as specified and as directed by Engineer-in-charge
Supply & fixing uPVC junction (double T/sockets) grade 'B' equal or unequal suitable for 75 mm bore pipe competed all as specified and as directed by Engineer-in-charge
S&F in repair PVC (SWR) floor trap 75mm dia with grating including jointing with solvent cement complete all as specified and directed.
M&L PVC (SWR) in repair gully trap 125 x 125 mm, seting and jointing with solvent cement complete all as specified and directed.
Supply & fixing uPVC vent cowl grade 'B, Suitable for 110 mm bore pipe complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base below floors all specified and directed.
M&L Machine pressed precast concrete interlocking paver block glossy with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade over Fazilka sand cushion and incl dismantling all as specified and directed.
Supply only fine aggregate (sand) for cushioning (Fazilka Sand) all as specified and directed
M&L PCC 1:2:4 type B1 using 20mm graded stone aggregates for coping & benching to manholes etc all as specified and directed.
M&L for reinforced cement concrete type B1 1:2:4 using 20mm graded stone aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, copings, bed plates,and the like including weathering, slightly rounded or chamfered angles and throating,incl formwork all as specified & directed. Note :- Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
M&L precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate and set cement mortar 1:6 as in cover slabs (for manholes etc,) chajjas, shelves and similar articles with plain faces complete all as specified and directed by Engr-in-charge.
Supply and laying DWCPE (SN8) 180 (OD)/150 (ID) mm dieameter drain pipes as per IS-16098 (Part-II), Laid in trenches on moorum bed to required slope, including all accessories/fittings, jointing and tested including demolition of breaking up of old drain pipes (Salt glazed ware, AC or reinforced concrete set in cement mortar) complete all as specified and as directed by Engineer-in-Charge
S & F Double bowl kitchen sinks (Diamond cut matt finish and ceramic under coat) made of stainless steel 304 Grade 1.0 mm thick for bowl, 2 mm thick for frame with plugs, washers and wastes including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 940 x 460 x 225 mm and bowl size 432 x 410 x 225 mm complete all as specified and as directed by Engineer-in-Charge
E/M Portion Taking down carefully copper/aluminium point wiring (light, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulatos, sockets etc to be measured separately), and making good disturbed surfaces of walls, floors etc to match with existing surfaces.
Taking down MCB with sheet metal enclosure, main switch, DB, etc and making good disturbed surfaces to match with existing surfaces.
Taking down carefully submain wiring/ service connection of any type complete with casing caping / conduit etc complete all as specified and directed.
M&L for concealed Point wiring for One light, one way switch controlled by one, oneway switch with single core PVC insulate, unsheathed multistranded copper conductor cable of size 2.5 sq.mm (FRLS) drawn in and including electrical grade PVC conduit 20 mm dia concealed on wall/ceiling/floor including PVC insulated unsheathed earth wire with multi stranded copper conductor of size 2.5 sq.mm(FRLS) including MS shunk sheet metal box with 3 mm thick bakelite plastic laminated sheet top cover with brass counter shunk screws with washer complete all as specified. Note - quoted rate shall include making good to the disturbed surfaces including plastering and painting to match with the existing colour.
All as per srl item No 102 above, but for ceilling/exhaust fan paint controlled by one switch and regulator complete all as specified and as directed.
All as per srl item No 102 above, but for 3 pin 5 Amp socket outlet on the same board with other switch, sockets complete all as specified and as directed.
All as per srl item No 102 above, but for one 3 pin 5 Amp socket outlet on independent board complete all as specified & directed
All as per srl item No102 above, but wiring with 4 Sqmm multistranded cable and earth wire with copper conductor of size 4 Sq mm for 15 amps power point all as specified
Supply and fix piano type, 230/250 Volts grade on top covers, Modular switch 1 way 6 A, 1 module complete all as specified and as directed.
Supply and fixed modular Socket outlet multipurpose type 2in 1, 3 Pin 6 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.
Supply and fixed modular switch 6/16Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.
Supply and fixed modular Socket outlet multipurpose type 2 in 1, 3 pin, 6/16 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.
Supply and fixing LED tube light fitting polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply complete all as specified and directed by Engineer-in-Charge.
S & F in repair Lamp holder incl LED lamp 9 watt, insulated body with back plate etc all as specified and as directed.
Supply and fix in repair heavy duty exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep with, blades and fan motor of Cap at least 190 Watt or above , and frame and louvers Complete all as specified and directed by Engr-In-Charge. Old U/S exhaust Fan will be deposited to MES Store yard by the contractor and no schedule of credit will be given tothe contractor on account of this item all as specified and directed by Engr-in-Charge..
Supply and fixing LED Bulkhead fitting 1 x 10 Watt, complete with Standard LED lighting fixture with extruded polycarbonate housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : <15%. (f) IP rating : IP-65. (g) CCT : Minimum 5400K (h) Polycarbonate housing white coloured (j) LED Driver of the same make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection minimum 2.5 kV. (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, maximum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing energy efficient LED security light fitting of 35W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 2 core flexible copper conductor cable 1Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 32mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Material & Labour for Sub Main Wiring with two run single core 10 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in PVC conduit & accessories Suitable size with and including 10 Sqmm copper green colour earth wire all as specified and directed by Engineer-in-Charge. NOTE-two run of 10 sq.mm & One run of 10 sq.mm & One run of PVC conduit with accessories shall be measured as One length complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel and wire mesh, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 10 cms above ground level. (ii) Outer edge of earth pit will be 1 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slanting position
Supply and fix sheet metal enclosure DB single pole and neutral for 240 volts 8 way with 200 Amps rated busbar flush/surface mounting double door complete all as specified and directed
Supply and fix Vertical MC DB distribution box 3 phase TPN 4 way double door including MCCB 125 Amp 16 KA as incommer with bus bar rating 200 Amps vertical type dust and vermin proof complete all as specified and as directed by Engineer-in-charge.
Supply and fix MCB single pole 240 Volt 6-32 Amps 10 KA complete all as specified and directed
Supply and fix MCB SPN 240 Volt 32 Amps 10 KA complete all as specified and directed
Supply and fix MCB TPN 415 Volt 32 Amps 10 KA complete all as specified and directed
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
M/s Karan Builders (BID ID -3453811)
PAREEK AND COMPANY (BID ID -3456083)
Dashmesh Construction Company (BID ID -3456453)
GHANSHYAM BHADU (BID ID -3460082)
AJAY CONSTRUCTION COMPANY (BID ID -3456224)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.68 MB
PS15.pdf
Tender Documents • 1.75 MB
BOQ_821897.xls
BOQ • 1.92 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .