Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST L1 | |
| 2 | L2₹24.3 L+₹2.6 L (11.9%)Rejected-Finance NAMBLABAL PAMPORE DISTRICT PULWAMA JAMMU KASHMIR 192121 | PAMPORE | PULWAMA | JAMMU KASHMIR | 192121 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹29.9 L+₹8.2 L (38.0%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹31.2 L+₹9.5 L (43.9%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹43.2 L+₹21.5 L (99.1%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
20 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GE 970 EWS C/O 56 APO PIN 913970
REPAIR MAINT BLDG SECUIRTY LIGHT FITTINGS LIGHTENING CONDUCTORS AND MAINT OF SUMMER WINTER APPLIANCES AND CONNECTED WORKS AT OAF AND JAK LI RC UNDER GE 970 EWS
2022_MES_570727_1
GE 970 EWS-62/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 970 EWS C/O 56 APO
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹76,000
Yes
7 Mar 2023
22 Dec 2022
23 Jan 2023
22 Dec 2022
20 Jan 2023
6 Jan 2023
Amount
Supply, laying ,jointing and testing of XLPE under ground insulated, armoured, heavy duty LT 1100 volts 16 Sqmm 4 core grade cable with aluminium conductor ISI marked, laid in trenches/pipes, fixed to poles/walls with suitable saddle & glands with and incl taking out the old burnt out cables complete all as specified and directed. (Note - Excavation, earthwork, sand cushioning , protection pipe and brick protection shall be measured and paid for separately )
All as per item No 1 above but of size 4 core 25 Sqmm -ditto--
All as per item No 1 above but of size 3.5 core 35 Sqmm -ditto--
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for taking out or laying of cable in soft/loose soil and getting out compete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50m where directed at a level not exc. 1.5M above the starting point complete all as specified and directed
Sand cushioning to underground cable with clean dry sand locally available 8cm thick before laying the cable and 15cm above the cable,stretching and testing of cable lcomplete all as specified and directed. Note : For payment purpose , punned thickness shall be measured and paid.
Brick protection with brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches with width of brick parallel to the length of cable complete all as specified and directed.
Supply & fixing in repair Cable junction Box/distribution Board IP 65 with metric knockouts for cable entry of size 10 to 25 sq mm x 2 core including fastening clamp with LT pole, box size : 333 x 233 x 120 mm (or nearest higher size) hinged cover with locking arrangements including with terminals TPN strip with 01 No MCB SP 6A complete all as specified and directed.
GI tube light grade galvanised with all fittings for cable protection 50 mm bore including fixed with poles complete all as specified and directed.
Supply & fixing in repair sub main wiring using FR Insulated unsheathed, multistrand copper conductor FRLS-H PVC cable 2 runs of size 2.5 sqmm for phase and neutral and 1.5 Sq mm for earthing drawn through with and including rigid PVC conduit 20 mm dia with clamps for fixed on pole for connection from junction box to light fittings / switch complete all as specified and directed. Note: Two runs of cable for phase / neutral and one run of cable for earth incl conduit shall be measured and paid as one unit length.
GI Pipe Bracket made out of Galvanised Iron Tubing 40mm bore (dia), light grade, 1.20 Metre long bent to shape as per specified for fixing Street Light Fitting including suitable size of clamps and applying Two coats of Aluminium Paint over a coat of Aluminium Primer including taking down old unserviceable GI Pipe bracket with clamps complete all as specified and as directed.
Material and labour in repair earthing complete with GI earth plate 60x60cmx6mm thick, burried directly in ground (Earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metre below normal ground level, connected togalvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron as earthing lead or steel all as shown in electrical plate No.5 and incl earth work, PCC pit and RCC cover, watering pipe 20mm dia medium grade, funnel, wiremesh, charcoal dust, 15 mm dia light grade protection pipe and salt etc and connected to earthing test point incl necessary earth work complete all as specified and as directed.
Supply and fixing in repair electronic driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 150 Watt, complete all as specified and as directed.
All as per item no 14 above but for LED Light Fitting of capacity 100 / 120 Watt- ditto--
All as per item no 14 above but for LED Light Fitting of capacity 60/72/75 Watt -ditto--.
All as per item no 14 above but for LED Light Fitting of capacity 45 Watt --ditto--
Supply and fixing in repair PVC insulated, PVC Sheathed flat twin core cable with stranded aluminium conductor of size 2.5 sqmm complete all as specified and directed. Make: Finolex/ Polycab/ Havells
Supply and fixing in repair LED flood light fitting of 150 Watts with driver inside a pressure die cast aluminium housing with toughened front glass cover, IP65 degree of protection complete all as specified and directed . Make: Bajaj Cat No. PRAZE F 180L WH NB-A5 TG SD / Havells/ Wipro/Crompton Greaves
All as per Ser Item No.19 here-in-before but of 200 Watts Make: Bajaj Cat No. PRAZE F 240L WH NB-A5 TG SD / Havells/ Wipro/Crompton Greaves
All as per Ser Item No. 19 here-in-before but of 250 Watts Make: Bajaj Cat No. PRAZE F 300L WH NB-A5 TG SD /Havells/ Wipro/Crompton Greaves
Supply and fixing in repair LED street light fitting 45 watts with high efficiency long life LEDs In-built replaceable electronic driver complete housed in pressure die-cast aluminium alloy covered with polycarbonate cover with IP65 degree of protection and fixing on existing bracket complete all as specified and directed. Make: Bajaj Cat No. ENXT P 54L PO PC SD / Havells/ Wipro/Crompton Greaves
All as per item No. 22 here-in-before but of 60 watt Make: Bajaj Cat No. ENXT P 72L PO PC SD / Havells/ Wipro/Crompton Greaves
All as per item No. 22 here-in-before but of 70 watt Make: Bajaj Cat No. ENXT P 84L PO PC SD / Havells/ Wipro/Crompton Greaves
All as per item No. 22 here-in-before but of 90 watt Make: Bajaj Cat No. ZELA P 108L WH PO TG SD / Havells/ Wipro/Crompton Greaves
All as per item No. 22 here-in-before but of 120 watt Make: Bajaj Cat No. ENXT P 144L WH PO TG SD / Havells/ Wipro/Crompton Greaves
Supply and fixing in repair LED post top light fitting made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection 40 watts with high efficiency long life LEDs In-built replaceable electronic driver complete fixing on existing bracket complete all as specified and directed. Make: Bajaj Cat No. BGCTNP 40W LED WH / Havells/ Wipro/Crompton Greaves
Supply and fixing in repair Integral LED aviation light luminaire comprising of yellow painted LM6 aluminium alloy housing polycarbonate enclosure complete all as specified and directed. Make: Bajaj / Crompton Greaves/ Havells/Wipro
Supply and fix in repair mild steel cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete including painting with 2 coats of alumunium paint over a coat of red oxide primer after preparation of surfaces icomplete all as specified and directed.
Material & labour in repairs ACSR conductor any size from poles including stringing on LT poles complete including aluminium binding wires, jumpering, bindings at insulators etc complete all as specified and dirceted.
Disconnecting the buildings of loose overhead conductors of LT lines from insulators and restringing the same for proper sag and rewinding including aluminium winding wires, tapes etc and jumpering for any type of conductor complete all as specified and directed. (Each LT line OH conductor shall be measured as unit length.)
Supply and fixing in replacement of insulator pin type porccelain viterious, white brown or green insulator including one galvanised mild steel spindle, two galvinised washers and one GI nut 100 mm hight and 65 mm dia for 1100 Volt grade complete all as specified and directed.
Supply and fixing in replacement of insulator shackle type porcelain viterious, white brown or green insulator including one galvanised mild steel strap, washers, insulator bolts, washers and nuts for working preasure 100 mm hight and 65 mm dia for 1100 Volt 115 mm dia, section of strap (31 x5) mm dia of bolt 14mm complete all as specified and directed.
Supply and fixing in repair incl errection of steel tubuler swage poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and shifting of conductors and insulators etc including painting the exposed portion of the pole with two coats of aluminium paint over a coat of red oxide primer and interally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer. Marking of pole number with black paint in yellow circle complete all as specified and directed.
Material & labour for PCC 1:4:8 type D2 using 40mm stone aggregate for pole foundation complete all as specified and directed.
Material & labour for PCC 1:2:4 type B-1 using 20mm graded stone aggregate including use and waste of form work for pole coping / any description complete all as specified and directed.
Taking down Aluminum strip of size 20 x 3mm with saddles and fixing screws etc. for roof conductors and down conductors above ground and refixing in the same location with new nuts and bolts, screws of suitable size and length and connected to air termination rod on top of the Over Head Water tank of height not more than 30 metre from ground level complete all as specified and directed.
S & F in repairs Copper strip 20 x 3.15 mm having pure copper with saddles and fixing screws etc. for roof conductors and down conductors above ground for Over head Water tank of height not more than 30 mtr from ground level complete all as specified and directed.
M&L for opening the unserviceable/burnt ceiling fan 1200/1400 mm sweep and cutting of old burnt copper winding and rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, testing and connecting for satisfactory run, complete all as specified and directed (NOTE:- Taking down/dismantling of ceiling fan and refixing after repair shall deemed to be include in this unit rate.)
Supply and fixing in repair of ball bearing of the ceiling fan (any sweep) as per existing size incl greasing/oiling, complete all as specified and directed by engr-In-Charge. Make:- SKF/ NBC
Supply and fixing in repair of gun metal bushes of suitable size for ceiling fan incl necessary mechanical work, complete all as specified and directed by Engr-In-Charge.
Supply and fixing in repair of flexible cable, three core 0.5 Sqmm PVC insulated copper conductor cable for connecting ceiling fan, complete all as specified and directed. Make:- Plaza, Havells .
S & F in repairs Stepped type electronic fan regulator flush type as per exisitng model on the existing board all as directed.
Supply and fixing in repair capacitor of of 2.5 MFD for ceiling fan, complete all as specified and directed.
Supply and fixing in repair capacitor of 4 Mfd for exhaust fan, complete all as specified and directed.
Supply and fixing in repair of ceiling fan blade set of three, heavy duty suitable for 1200/1400mm sweep of as per existing make as direcetd.
Supply and fixing in repair of PVC canopy for ceiling fan 1200/1400mm sweep complete for existing various makes/model of fan, complete all as specified and directed by Engr-in-Charge.
M&L in repair for opening and cutting of old burnt copper winding of exhaust fan and rewinding of exhaust fan motor of sweep 450mm with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, re-assembling, testing and connecting for satisfactory run, complete all as specified and directed as specified and directed. (NOTE:- Taking down/dismantling of exhaust fan and refixing after repair shall deemed to be include in this unit rate.)
All as per srl item No. 50 here-in-before, but 300mm sweep -ditto-
Supply and fixing in repair ball bearing of exhaust fan of any size/make as per the existing, complete all as specified and directed. Make: SKF/NBC
M&L for painting the exhaust fan including louvers of size 300/450mm sweep with two coats of synthetic enamel paint after cleaning and making the surface of oil/dust free, complete all as specified and directed.
M&L for servicing of geyser by disconnecting the electric and water supply connections, dismantling the geysers of any size, type & capacity and opening the top and bottom cover, thermostat, heating element, safety valve, vent pipe, separating inner & outer tank, removing glass wool insulation complete and keeping aside for re-use after de-scaling of inner tank by liquid chemical and with pressure water jet and assembling back the geyser including re-installation on wall with studs, nuts & bolts complete and testing after reconnecting electric and water connections, complete all as specified and directed.
Supply and fixing in repair heating element for geyser of capacity 1.5KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:- Usha/ Bajaj/ Havells
Supply and fixing in repair Heating element for geyser of capacity 2.0KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:- Usha/ Bajaj/ Havells
Supply and fixing in repair thermostat for Geyser of capacity 25/35/50/100 ltr (long size) with temperature setting adjustment range from 40 to 85°C, ISI Marked, complete all as specified and directed. Make:- Philips/ Bajaj/ Venus
Supply and fixing in repair geyser syphon assembly Set suitable for 25 ltr capacity geyser, fixed in replacement, as per existing complete all as specified and directed by engr-in-Charge.
All as per item Srl No. 58 above but for 35 Ltr capacity -ditto-
All as per item Srl No. 58 above but for 50/100 Ltr capacity -ditto-
Supply and fixing in repair rubber gasket for water heater storage type of any capacity and suitable as per the existing, complete all as specified and directed
Supply and Fixing in repair plug top 15/16 Amps for Geyser, complete all as specified and directed. Make:- Havells/ Anchor/Leader/Plaza
Supply and fixing in repair PVC sheathed three core copper conductor flexible wire of size 2.5 Sqmm for connecting geyser, complete all as specified and directed. Make:- Finolex/Polycab/L&T
S & F in repairs sheet metal enclosure SPN with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified.
Supply and fixing in repair of safety valve for geyser of 25/35/50 litre capacity, as per existing make complete all as specified and directed
Supply and fixing in repair of non return valve 15mm dia for geyser of 25/50 litre capacity, complete all as specified and directed.
Supply and fixing in repair heavy duty PVC connector 600mm long 15mm dia with PTMT nut for geyser of 25/50 litre capacity, complete all as specified and directed.
Supply and fixing in repair copper inner tank of geyser capacity 15/25 litre and refilling of glass wool, refixing, connecting and testing, complete all as specified and directed.
All as per item Srl No. 68 above but for 35 Ltr capacity -ditto-
All as per item Srl No. 68 above but for 50 Ltr capacity -ditto-
Supply & fixing in repair stop cock brass 15mm dia, complete all as specified and directed.
M&L for preparation of surface of Geyser of capacity 25/35/50 Ltr by scraping, removing old paint etc and applying two coats of synthetic enamel paint complete all as specified and directed.
Supply and fixing in repair of compressor fo refrigerator of 165 to 200 ltr capacity as per the existing complete all as specified and directed.
Supply and fixing in repair of thermostat for refrigerator of 165 to 200 ltr capacity.
Supply and fixing in repair of thermal relay for refrigerator of 165 to 200 ltr capacity.
M&L for Charging refrigerant R134A and testing for proper cooling and leakage complete for refrigerator of 165 to 200 ltr capacity all as specified and directed.
Supply and fixing in repair of compressor fo refrigerator of 210 to 335 ltr capacity as per the existing complete all as specified and directed.
Supply and fixing in repair of thermostat for refrigerator of 210 to 335 litre capacity.
Supply and fixing in repair of thermal relay for refrigerator of 210 to 335 litre capacity.
M&L charging refrigerant R134A and testing for proper cooling and leakage complete for refrigerator of 210 to 335 ltr capacity all as specified and directed.
Supply and fixing in repair of compressor for deep freezer of 210 to 400 ltr capacity as per the existing complete all as specified and directed.
Supply and fixing in repair of thermostat for deep freezer of 210 to 335 litre capacity.
Supply and fixing in repair of thermal relay for deep freezer of 210 to 335 litre capacity.
M&L for Charging refrigerant R134A and testing for proper cooling and leakage complete for deep freezer of 210 to 400 ltr capacity all as specified and directed.
M&L for disconnecting the electric supply from the mains, transporting the window/split type air conditioner capacity 1.5/2.0 ton from original location to workshop to carry out the servicing complete and re-fixing at the original position after repairs and making the ACs fully functional and testing for satisfactory working, complete all as specified and directed.
Taking out old burnt/unserviceable compressor from the air conditioner 1.5/2.0 ton capacity and supply and fixing new compressor as per the existing, re-fixing in position incl testing satisfactory working complete all as directed.
M&L for charging refrigerant gas R134A in 1.5/2.0 ton capacity window /Split type air conditioner complete including testing for satisfactory working after flushing out and cleaning the surface with nitrogen gas for checking the leakage, complete all as specified and directed.
Supply and fix in repair blower motor suitable for 1.5/2.0 ton capacity air conditioner all as directed.
Supply and fix in repair thermostat suitable for 1.5/2.0 ton capacity air conditioner all as directed.
Supply and fix in repair of running condenser 36 Mfd, complete all as directed.
Supply and fix in repair of starting condenser 100/120 Mfd, complete all as directed.
Supply and fix in repair of relay suitable for 1.5/2.0 ton capacity air conditioner, complete all as directed.
Taking out unserviceable/burnt stabilizer of 3 KVA to 5 KVA capacity, rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, replacement of knobs, LED's etc. and making fully functional on load as connected to Refrigerator/Deep freezer/AC complete all directed.
All as per item Srl No. 93 above but for capacity 0.25 to 1 KVA -ditto-
Material and labour for servicing of 1 KW Hot water dispenser of capacity 20 Ltr including replacement of unserviceable parts i.e bushes, bearings, heating coil of cap , burnt cable and other essential parts to make the dispenser fully functional complete all as specified and drected.
M&L for Dismantling the complete fuel injector pump of water heating plant of various capacity upto 2000 ltrs, transporting to trade workshop for repairs and complete servicing and refixing the same after satisfactory repairs, reinstallation, testing and commissioning complete, all as specified and directed.
Material and labour for calibration and complete repair of fuel injection pump of water heating plant of various capacity upto 2000 ltrs, on work bench for fine spray and machining work and refixing the same for satisfactory functioning, complete all as specified and directed.
Supply and fix in repair nozzle of hot water plant as per existing size complete all as specified and directed.
Supply and fix in repair pressure meter suitable for hot water generator as per existing size complete all as specified and directed.
Supply and fix in repair fuel filter suitable for hot water generator as per existing size complete all as specified and directed.
Supply and fix in repair solenoid switch for hot water generator as per existing size complete all as specified and directed.
Supply and fix in repair ball valve 15mm dia bore size complete all as specified
Supply and fix in repair burner gasket suitable for hot water generator as per existing size complete all as specified and directed.
Supply and fix in repair digital type electronic temprature gauge with thermostat control relay suitable for 2,00,000 K Cal/hr capacity hot water generator as per existing size and testing complete all as specified and directed.
Supply and fix in repair photo ignition transformer suitable for hot water generator/plant as per existing size and testing complete all as specified
Supply and fix in repair fire proof current lead suitable for hot water generator/plant as per existing size and testing complete all as specified.
Supply and fix in repair indicator assembly, complete all as specified
Supply and fix in repair bimetallic overload relay 4.0 - 6.5 Amps type ML complete all as specified
Supply and fix in repair electromagnetic rod combined with positive/ negative terminals suitable for hot water generator of any capacity as per existing size and testing complete all as specified and directed.
Supply and fix in repair photo censor suitable for hot water generator/plant as per existing size and make incl testing complete all as specified and directed.
Supply and fix in repair USB relay box incl sequence meter suitable for hot water plant as per existing size and make incl testing complete all as specified and directed.
Supply and fix in repair high pressure diesel/fuel pipe with internal and outer threads suitable for hot water generator/plant as per existing size incl testing complete all as specified and directed.
M&L for dismantling fuel tank of water heating plant, servicing, decarboning, cleaning, removing of of complete water plant and reassembling the same after cleaning properly by removing all deposited particles, dust, carbon etc, complete all as specified and directed.
Supply and fix in repair 40mm dia safety valve as per existing complete all as specified
M&L for disconnecting and taking out burnt hot water plant blower motor, transporting to workshop, dismantling carefully, cutting out burnt windings, cleaning the slots and rewinding with super enamelled copper winding wire of appropriate gauge & weight incl all insulating materials, varnishing, drying, heating etc and incl replacement of ball bearings as per existing, reassembling and refixing at original site and testing, complete all as specified and directed.
Supply and fix repair sensor board suitable for water heater 15/ 25 Ltr capacity complete all as specified and directed. Make :- Venus/bajaj/Usha
Supply and fix in repair indoor unit complete 1.5 TR capacity suitable for existing Split AC unit complete all as specified and directed.
Supply and fix in repair outdoor unit cabinet complete 1.5 TR capacity incuding condenser, condenser motor, blower, blower motor etc complete all as specified and directed
S & F in repairs water heater outer body cover along with glass wool insulation suitable for 25 ltr capacity as per existing make and model complete all as specified and directed
Ditto as per item No 119 here in before but of water heater capacity 35 ltr -ditto-
Ditto as per item No 119 here in before but of water heater capacity 50 ltr -ditto-
S & F in repairs Condensing unit suitable for outdoor unit of 1.5 / 2 TR Split/window type AC unit, complete all as specified and directed. Make : Voltas/Carrier/Hitachi
Supply and fix in repairs strainer drier for 1.5 ton window/ split type AC complete all as directed.
S & F in repairs cooling coil for refrigerator of any capacity complete all as directed.
S & F in repairs Freezer chest door suitable for any capacity refrigerator complete all as directed.
Supply and fix in repair legs of refrigerator/water cooler of existing size/guage made of mild steel complete and applying anti rust paint complete all as directed.
S & F in repairs Voltage Stablizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 130v to 300 V with output voltage stabilized at 220 V with accuracy of + 5% capacity 5 KVA complete all as specified and directed.
S & F in repairs copper pipe for suction and discharge 5/8'' & 3/8" dia incl provn of new insulation over the pipes for split ACs complete all as directed.
S & F in repairs copper pipe for suction and discharge 1/2'' & 1/4" dia incl provn of new insulation over the pipes for split ACs complete all as directed
S & F in repairs new PCB unit (remote control) of 1.5 / 2 TR capacity of Split type AC unit of existing make & model complete all as directed
ms new dar water star
M/S M.Y Enterprises
M/S MIR SAJAD ENTERPRISES
CHINAR CONSTRUCTION TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .