Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹42.9 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹44.2 L+₹1.2 L (2.89%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹46.3 L+₹3.3 L (7.77%)Rejected-Finance HOUSE NO 165 A VILLAGE POST MORTA DISTT GHAZIABAD U P PIN 201003 | GHAZIABAD | GHAZIABAD | UTTAR PRADESH | 201003 | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹47.7 L+₹4.7 L (10.9%)Rejected-Finance | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹48.4 L+₹5.4 L (12.6%)Rejected-Finance N A | NA | NA | 121004 | L-5 | Rejected-Finance L-5 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
26 Feb 2024, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
ADDN/ALTN TO CERTAIN OTM BUILDINGS, MAIN GATE AND PROVN OF CHAIN LINK FENCING AT CERTAIN LOCATIONS AT AF STN CHANDINAGAR IN AOR OF GE (AF) FARIDABAD
2024_MES_640803_1
GE (FBD)/AF-87/2023-2024
Open Tender
Civil Works
Item Rate
180 days
Chandinagar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹94,000
Yes
9 Apr 2024
5 Feb 2024
28 Feb 2024
5 Feb 2024
26 Feb 2024
19 Feb 2024
5 Feb 2024 - 9 Feb 2024
Amount
Taking down of old existing roof treatment of any description incl scrub and remove loose concrete, brick tiles, mud fuska, plaster, bitumen, oil grases and any other materials that might effect adhesion by wire brushing the surface and cleaning of the surface throughly with water and disposed off old materials from site complete all as specified and directed by Engineer-in-Charge.
M&L for 50 mm thick cement concrete 1:2:4 type B-0 ( using 12.5 mm graded stone aggregate) as in padding/ base on roof complete all as specified and directed by Engineer-in-Charge.
M&L for 20 mm thick plastering in CM 1:4 on RCC roof slab, finish even and smooth for receive water proofing APP membrane using WPC @ 3% by weight of cement complete all as specified and directed by Engineer-in-Charge. Note : WPC will be measured and paid separately.
Supply only Integral water proofing compound complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of the plastered roof surfaces and fix the APP polymeric water proofing membrane of minimum 3 mm thickness & weighing not less than 3.6 Kg / Sqm of , black finished reinforced with non-woven ployster 160 gsm matt with a thermofusible finish laid over primer conforming to IS:3384-1965 @ 0.5 Kg/Sqm and thereafter apply compitable hot blown bitumen 85/25 @ 1.20 Kg/Sqm torching overlaps with a propane or a butane gas torch with a overlap of 75 mm at the sides and 100 mm at the end sealing complete all as specified and directed by Engineer-in-Charge.
Dismantling water tanks and removing to store of capacity n exc 500 ltrs complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 500 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed by Engineer-in-Charge.
Dismantling water tanks of capacity exc 500 and n exc 1000 ltrs and removal to contractor's store yard, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 1000 ltrs capacity Rotational moulded polyethylene water storage tanks tripple layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work built in cement mortar in any position including all quoins, arches & pillars etc complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick or concrete surfaces of walls, facia etc to be finished even and smooth (w/o using extra cement) complete all as specified and directed by Engineer-in-Charge.
M&L for preparing newly plastered surfaces and applying two coats of distemper oil emulsion including priming plastered and other surfaces with chalk whitening/putty preparatory to distempering on surfaces of walls complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment from walls, fins, chajja etc shall include brooming down or steel wire brushing, scrubbing down smoke soot, moulds, moss and efflorescence salts and treating oil and greasy spots and removing debris/ malba to low lying area out side of MOD land and applying 3 mm thick a layer of wall care water proof putty on scrapped/uneven surfaces to match with the existing surfaces before application of primer/distemper and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frame with shutters (without taking off shuttters from frames) size exc 1.5 Sqm but not exc 4 Sqm each each and removing from site and making good disturbed surfaces as per existing complete all as specified and directed by Engineer-in-Charge.
S&F powder coated aluminium frame of standard section for doors, windows , ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engineer-in-Charge.
M&L 5 mm thick tinted sheet glass ordinary quality and glazing with oil putty/rubber/aluminium beading in square pane complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing for toughened glass frameless partition, 12 mm thick Toughened Glasspartitions upto 3.00 M with proper machine edge finish in angle & fixed in the flooring with Aluminium 'U' channel & flushed with the ceiling. Glass panels to be formed as per approved modules 12 mm thick clear toughened glass edge polished and accurate designed holes to be installed by means of steel angle or spider fittings of an . The structural Glass walls system shall be complete with proper water tight silicon sealants /gaskets. M.S Brackets to support the structure system shall be hot dipped galvanized and slots in the brackets to be pre drilled not flame cut. All bolts,nuts,washers shall be 300 series non magnetic stainless steel and lock washers to be provided at all bolting connections. All anchor fasteners . All structural silicone shall be of Dow Corning make. The Rates includes all material, Labour, Wastages, Cost of scaffolding,fixing & Finishing with frosted design film etc complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing for 12 mm thick Toughened Glass frameless doors upto 2.10 M with all as per required arrangement & proper machine edge finish in angle & fixed in the flooring side with Aluminium 'U' channel . Glass panels to be formed as per approved modules 12 mm thick clear toughened glass edge polished and accurate designed holes to be installed by means of steel fittings of Including Floor spring , Lock approved make, Door Handle both side, all works including labour, wastages, cost of scaffolding, finishing with frosted design film etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing factory made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 48x40 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified by the manufacturer and as per directions of Engineer-in-Charge
M&L for grinding/polishing to existing terrazo flooring by mechanical machine method complete all as specified and directed by Engineer-in-Charge.
Material and labour for 18 to 22 mm thick machine cut pre-polished Kota stone slabs in riser of steps, skirting, dado and pillar laid over 10 mm thick cement screed bed in CM 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and directed by Engineer-in-Charge.
Demolition of PCC cement concrete above ground floor and paving n.exc 15 cm thick (below or above ground level) un reinforced complete complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:4:8 type D-2 (40mm graded stone aggregate ) for sub base 75mm thick complete all as specified and directed by Engineer-in-Charge.
Material and labour for 600x1200 mm size first quality vitrified tiles 10-15mm thick Dark shade, high glossy, polished, in floors etc,, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20 mm thick screed bed in cm 1:6 complete all as specified and directed by Engineer-in-Charge.
All as per item No 27 above but area of each tile n exc 0.36 Sqm in vertical surface such as skirting, dado and risers including 10 mm thick rendering in cm 1:4 on brick or concrete surfaces of wall to receive vertical tiles.
S&F 75mm size brass handles, cast type polished bright complete all as specified and directed by Engineer-in-Charge.
S&F magnatic catch for wooden cabinate shutters complete all as specified and directed by Engineer-in-Charge.
Dismantling timber scantling as in fillets, rails, posts, rafters, purlins, etc under 40 sq.cm in section of framed work complete all as specified and directed by Engineer-in-Charge.
M&L second class soft-wood as in scantlings of timber framed and fixed wrought complete all as specified and directed by Engineer-in-Charge.
M&L for 2nd class HW plain fillet n exc 3 sqcm square rectangular or triangular in section clean sawn secured with nails or brads complete all as specified and directed by Engineer-in-Charge.
Material and labour for 12mm thick PVC Prelaminated board, prelaminated one side with decorative choice laminations & other side balancing white lamination, fixed with screws to timber frame work and fixed in repairs complete all as specified and directed by Engineer-in-Charge.
Material and labour for 18mm thick PVC Prelaminated , board, prelaminated one side with decorative choice laminations & other side balancing white lamination, fixed with screws to timber frame work and fixed in repairs complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs continuous (piano) hinges mild steel bright finish or electrogalvanised 30mm flaps complete all as specified and directed by Engineer-in-Charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) any thickness, including cover fillets and grid frame work complete all as specified and directed by Engineer-in-Charge.
M&L for Providing and fixing in true horizontal level 605 mm. X 605 mm. false ceiling system using hot dipped galvanized steel section, exposed surface with pre-coated capping, main tee of size 24 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to centre maximum and rotary stitched cross tee of size 24 x 27 mm, having 0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 24 x 27 mm, having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the wall. The above grid is suspended at every 1200mm c/c. in both directions using 2.0 mm complete all as specified and directed by Engineer-in-Charge.
Excavation in post holes each n.exc 0.5 Cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25Cm watering and removing surplus soil to a distance n.exc 50m and making good surface in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in for fixing angle iron and coping including necessary form work complete all as specified and directed by Engineer-in-Charge.
S&F MS work as in post and strutt and fencing, drilled and countersunk for balusters running bars for doors balusters,noising to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts,posts and struts in fencing including cutting tops to shape as directed drilling hoes nothcing for wire etc flat iron fillets ( for securing wire mesh ) including all necessary drilling bolting or riveting etc. and similar work conforming to Fe - 290 Gde E - 165 complete all as specified and directed by Engineer-in-Charge.
Supply only Chain link MS galvanised fencing, any size or type complete all as specified and directed by Engineer-in-Charge.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed by Engineer-in-Charge.
M&L for TMT Bars 10 mm dia & over, cut to length bent to shape, reuired, including cranking bending and fixing to beam slab, chajja for faciliating guniting complete all as specified and directed by Engineer-in-Charge.
M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including portions framed and hung as gates, including pintle hinges,stops, hand-made sliding bolts, etc complete all as specified and directed by Engineer-in-Charge.
M&L in applying two coats of synthetic enamel paint over a coat of red oxide primer to new steel and iron surfaces over 10cm in width or girth including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
Demolition of stone slab and tiles of any description or thickness in floors, approns etc laid, bedded and pointed in any mortar and removing rubbish off the premises including Taking down cement plaster including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for 15mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces of walls finished even and smooth w/o using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for providing PVDF aluminium composite panels with fire resistent mineral filled core material as in interior/exterior wall cladding upto G+2 storeyed external wall surface shall consist of following complete all as specified and directed by Engineer-in-Charge. (i) Aluminium sheet making a total panel thickness of 6 mm with outer surface finished with PVDF based coating 0.25mm ,inner surface finished with a thin coat of polyster paint. The cleness of aluminium cover sheet shall be 0.50 mm inner core shall be of LDPE (ii) aluminim framing of section 25 mmx50 mm x1.50mm thick , (iii) aluminium grid shall not be exceed 1.0 Sqm each the aluminium grid not more than 1 m c/c shall be fixed with MS angle 30x30x5 mm projected 150mm from surface of wall, (iv) Colour shall be approved by GE. (v) Joint shall be sealed with silicon weater proof sealing compound with help of masking Tapes. Note: Canopy,borders, projections etc will be measured in Sqm for payment purpose.
M&L for cut outs/ metal sign board of dogs Size 1.2m X 1.5m PVDF aluminium composite panels with fire resistent mineral filled core material printed with vinayl OR print with 3 M retro reflective tapes on ACP Sheet fixed on the ACP Sheet with the help of high bond double side taps Of 3M Grey VHB taps 2 mm thick complete all as specified and directed by Engineer-in-Charge. Note: coloure and Type of dogs choice shall be approved by GE.
M&L for 3d Stainless steel LED lighted letters OR print with 3 M retro reflective tapes on ACP Sheet above 12 inch complete all as specified and directed by Engineer-in-Charge. Note: Size shall be approved by GE.
S&F powder coated aluminium window and ventilator shutters , side hung type / sliding without sash bars, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, ruber packing , anodised aluminum snap beading , screws, anodised aluminium fittings such as peg stays 150mm long (1nos). hinges type B-21 100mm long (2nos) suitable handle (1nos) complete all as specified and directed by Engineer-in-Charge.
M&L for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 complete all as specified and directed by Engineer-in-Charge.
S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
S&F for mild steel work in tubular trusses and vertical post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed by Engineer-in-Charge.
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall , fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for powder coated aluminium partition fixed type/with out sash bars aluminium section weighing 0.55Kg/RM incl necessary jointing cleats, glazing clips rubber packing aluminium snap beading, screw etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing ordinary quality sheet glass 5mm thick in panels of aluminium door and window etc fixed with aluminium clip and rubber beading all as specified exc 0.5 Sqm complete all as specified and directed by Engineer-in-Charge.
Material and labour for 9mm thick Prelaminated particle, board, exterior grade, prelaminated both side with both side decorative choice laminations fixed with screws/beading to timber/aluminium frame work complete all as specified and directed by Engineer-in-Charge.
Supply and fixing powder coated aluminium door shutters, aluminium section weighting 0.55 Kg/ RM including necessary jointing cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, powder coated aluminium snap beading screws etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair aluminium (die cast) body door closer hydraulically regulated designation No.3 universal type suitable for aluminium door shutters of width 851 to 1000mm and of weight between 61 to 80Kg complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for double action floor spring hydraulically regulated made ou of minium 1.25mm thick aluminium allooy sheet foundation box, main body with stainless steel cover governing pivot made of brass, other parts made of MS heavy duty and fixed complete all as specified and directed by Engineer-in-Charge.
M&L for FISSURED TEGULAR Edge mineral fibre ceiling tiles 600X600 mm of size 600mmx600mmx12 to 15 mm having NRC 0.55, Light reflectance of >84% (WT), thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 99% , having Fire Performance CLASS O / CLASS 1 (BS 476) complete all as specified and directed by Engineer-in-Charge.
Taking down carefully aluminium point wiring (light, Socket or power) complete including fittings and fixtures such as switches, ceiling roses pendents, regulators, sockets etc for taking credit to be measured separetly including making good the disturbed portion/surface complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with colour coding multistranded copper conductor cable, PVC insulated and unsheathed size 1.5 sqmm with PVC concealed Conduit ( dia not less than 20 mm) with fixing accessories for one light /fan/bell point controlled by one switch with pressed steel concealed terminal boxes covered with 3mm thick laminated sheet incl. contineous earth wire of PVC insulated unsheathed multi stranded copper conductor cable size 1.5 Sqmm for earth wire connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No 65 above but for one 3/5 pin socket 5 Amp on same board, with 1.5sqmm wire with 1.5sqmm earth wire.
All as per item No 65 above but for one 3/5 pin socket 5 Amp on independent board with 2.5 sqmmwire with 2.5 sqmm earth wire .
All as per item No 65 above but for 3 pins socket outlet 15 Amps independent with 4.0 sq mm incl contineous earthing with multistandred copper conductor PVC insulated unsheathed size 4.0 Sq mm complete all as specified and directed. Note:- (For item 65 to 68 ) Cost making good disturbed surface below existing point wiring taken out vide item No 65 and cutting chases and making good of disturbed surfaces by cement & sand mortar (1:3) and surface finish as per adjustment surface conduit and all accessories as required for concealed point wiring vide item No 65 to 68 as applicable shall be deemed to be included in the unit rate quoted against these items.
S&F Modular switch flush type, 5/6 Amps, single pole one module white colour 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Modular switch flush type, 15/16 Amps, single pole one module white colour 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Modular socket 3 pins combined, 5/6 Amp, flush type (multi purpose) two module ,230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Modular socket 5 /6 pins combined, 15A/16 Amp, flush type(multi purpose) two module 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Modular white cover plate with frame suitable for six module way 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Modular white cover plate with frame suitable for 16 module way 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Modular metal flush box suitable for six module way 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Modular metal flush box suitable for 16 module way 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Ding Dong door bell 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Modular Bell push flush type 5 Amps, single pole one way 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F ceiling rose, PVC / Polycarbonate isolated body ,surface backlite, 65x50mm, three terminals, 230 Volts, AC complete all as specified and directed by Engineer-in-Charge.
S&F LED tube light fittings 20W (4 feet) wall mounted LED batten extruded PVC heat sink provided for efficient heat dissipation & integrated electronic driver optics diffused complete including electrical connection with copper cable from ceiling rose to fittings and including taking down existing fittings complete all as specified and directed by Engineer-in-Charge.
S&F Skylite recess mounting,36W, LED 2'x2' luminaire integrated electronic driver, optics diffused, complete including electrical connection with copper cable from ceiling rose to fittings and taking down old Unserviceable light fittings of any type and any size complete all as specified and directed by Engineer-in-Charge.
M&L for submain wiring with 2X6.0 SQMM+1X6.0SQMM Earth Wire single core PVC insulated FR sheathed copper cable connecting to common earth dolly in and including heavy duty PVC concealed Conduit 25mm and dismantling and taking down existing unserviceable wiring, all accessories complete all as specified and directed by Engineer-in-Charge. Note:- (i)Cost making good disturbed surface below existing point wiring and cutting chases and making good of disturbed surfaces by cement & sand mortar (1:3) and surface finish as per adjustment surface conduit and all accessories as required for concealed point wiring as applicable shall be deemed to be included in the unit rate quoted against these items.
S & F in repairs single pole and neutral sheet metal enclosures for Distribution board (DB's)suitable for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail 240 V, 50 Hz supply double door SP&N DB system 12 ways complete all as specified and directed by Engineer-in-Charge.
S & F of single pole and neutral sheet metal enclosures for Distribution board (DB's)suitable for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail 240 V, 50 Hz supply double door SP&N DB system 8 ways complete all as specified and directed by Engineer-in-Charge.
S&F RCBOs for earth leakage,over load & short circuit protection 2 pole ,32 Amp rating, 300 mA capacity suitable for 240 Volts and including taking down existing MCB/ RCCB complete all as specified and directed by Engineer-in-Charge.
S&F MCB SPN 40-63 Amps 240V incl all termnials, fitting etc. including taking down complete all as specified and directed by Engineer-in-Charge.
S&F MCB SP 06 to 40 Amps 240V incl all termnials, fitting etc including taking down complete all as specified and directed by Engineer-in-Charge.
M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level),and top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised means of earth wire 4 mm dia with bolts, nuts & check nuts, and washers of galvanised iron protection pipe light grade of 15 mm dia and watering pipe medium grade of 20 mm dia and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC 1:3:6 type C-2 all as shown in electrical plate No-3 of SSR part-I of 2009 connected to earthing test point all as specified and indicated including all earth work excavation, returning filling and disposal of surplus soil and testing on completion complete all as specified and directed by Engineer-in-Charge.
S&F LED Focus Light 25/35 watt of pressure die cast aluminium housing with mid power LED as lightening source and PC cover having top opening inbuilt LED driver with IP66 protection and impact resistance of IK-07 complete with nut bolts, washers etc including electrical connection with copper cable from ceiling rose to fittings complete all as specified and directed by Engineer-in-Charge.
Supply and install hi wall split type Air conditioner with (2.0 ton) indoor/outdoor unit complete with inverter technology , cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 ton complete all as specified and directed by Engineer-in-Charge. .Note: (i) Rate of AC Installation , all connections, nut-bolts, washers, complete labour, testing, Copper tubing ( incl both pipe size of pipe 1/2" and 1/4" ) upto 3.0 mtr with electric wire , drain pipe complete are incl in quoted rate and Copper tubing , electric wire and drain pipe exceeding 3.0 mtr are measured and paid separately
Supply & fix Voltage stabilizer for automatic operation single phase naturally air colled indoor type &designed for input variation between 170 volts to 250 volts with output voltage stabilized at 230 with accuracy of +-2.5% and capacity 5 KVA complete all as specified and directed by Engineer-in-Charge.
S&F single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole 20 amps MCB complete all as specified and directed by Engineer-In-Charge.
S&F of copper tubing outer dia ( 1/2" and 1/4") suitable for 1.5 TR AC including nitril rubber thermal insulation capacity complete all as specified and directed by Engineer-in-Charge.
M&L for stand ( wall mounted type & Floor mounted type ) of suitable for split type AC complete all as specified and directed by Engineer-in-Charge.
M& L for PVC drain pipe 110mm complete all as specified and directed by Engineer-in-Charge.
M&L for submain wiring with 2X4.0 SQMM+1X4.0SQMM Earth Wire single core PVC insulated FRLSH sheathed copper cable connecting to common earth dolly in and including heavy duty PVC Cascing & Caping all accessories complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling, including spreading levelling and well ramming in layers not exceeding 25cm apart complete all as specified and directed by Engineer-in-Charge.
Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushoning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed by Engineer-in-Charge.
M&L for sub class `B` bricks for cable protection complete all as specified and directed by Engineer-in-Charge.
Supplying ,laying and testing XLPE cable insulated screened, PVC bedded galvanized steel strip of wire armored , electric power cable (Heavy duty ) 1100 volts grade with stranded aluminum conductorof size 50 sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 10 sqmm 4 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc complete all as specified and directed by Engineer-in-Charge. Note: (i) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways and Aluminium thimbles/lugs are incl in the quoted rates. (ii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
airstack india
NAVEEN KUMAR TYAGI
36SHRI RADHEY ASSOCIATES
Gaurav India Corporations
M/s Kanha Enterprise
MAHABIR SINGH
UNIVERSAL ENTERPRISES
PG CONSTRUCTION AND COMPANY
stage.html
html • 0.07 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .