Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 LAccepted-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Lowest tender accepted | |
| 2 | L2₹13.6 L+₹1.6 L (13.6%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹14.0 L+₹2.0 L (16.5%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹14.0 L+₹2.0 L (16.6%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹14.6 L+₹2.6 L (22.1%)Rejected-Finance NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
30 Jul 2022, 6:00 pmClosed
GE (AF) Adm Area Agra 282008
GE (AF) Adm Area Agra 282008
REPAIR REPLACEMENT OF LT UG CABLES LT CABLE END BOX MCCBS AND OTHER ALLIED WORKS IN CAMP AREA UNDER GE AF ADM AREA AT AF STATION AGRA
2022_MES_535574_1
8000-1973/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF Station Agra
Class E
Cat b i
8 documents required · 8 mandatory
₹500
Yes
GE AF Adm Area Kheria Agra
₹30,000
Yes
13 Aug 2022
4 Jul 2022
1 Aug 2022
4 Jul 2022
30 Jul 2022
18 Jul 2022
4 Jul 2022 - 16 Jul 2022
Amount
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for laying for cables etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any type of soil including removal of sand, bricks/PCC covers laid for cable proection complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exc. 25 cm in any type of soil complete all as specified and directed.
Removing surplus excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Material and labour for old size sub class 'B' bricks well burnt, laid flat as in cable protection complete all as specified and directed.
Re-laying of old serviceable bricks item retreived from Sl No.01 here-in before for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable all as directed.
M&L for local sand cushioning with dry and clean over and under the cable for protection of cable, 80 mm sand laid before laying the cable 150 mm sand after laying the cable and punned down complete all as directed
Material and labour for replacement of GI tubing light grade 100 mm bore for cable protection fixed on pole/wall or laid in floor/trenches/drain etc. complete with necessary clamp, nut, bolts, washers and socket for fixing the pipe and making good the disturbed surface of wall, floor or roof etc all as specified and directed.
Material and labour for replacement of GI tubing light grade 50 mm bore for cable protection fixed on pole/wall or laid in floor/trenches/drain etc. complete with necessary clamp, nut, bolts, washers and socket for fixing the pipe and making good the disturbed surface of wall, floor or roof etc all as specified and directed.
Material and labour for replacement of GI tubing light grade 40 mm bore for cable protection fixed on pole/wall or laid in floor/trenches/drain etc. complete with necessary clamp, nut, bolts, washers and socket for fixing the pipe and making good the disturbed surface of wall, floor or roof etc all as specified and directed.
Taking out old unserviceable LT UG cables of size 10 to 70 Sq mm 2/3.5/4 Core from trenches, poles/walls and floor for removing of fault or re-laying (Necessary earth work shall be measured and paid under respective item of Schedule) complete all as directed.
Taking out old unserviceable LT UG cables of size 95 to 150 Sqmm 3.5/4 Core from trenches, poles/walls and floor for removing of fault or re-laying (Necessary earth work shall be measured and paid under respective item of Schedule) complete all as directed.
Re-Laying XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 10 to 70 Sqmm 2/3.5/4 Core (Item retreived from item 21 here-in-before) laid in trenches or fixed on wall/floor/poles after removing fault complete all as specified and directed.
Re-Laying XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 95 to 150 Sqmm 3.5/4 Core (Item retreived from item 22 here-in-before) laid in trenches or fixed on wall/floor/poles after removing fault complete all as specified and directed.
Supply and Laying in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 120 Sqmm 3.5 core complete all as specified and directed.
Supply and Laying in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 95 Sqmm 3.5 core complete all as specified and directed.
Supply and Laying in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 70 Sq mm 3.5 core complete all as specified and directed.
Supply and Laying in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 50 Sq mm 3.5 core complete all as specified and directed.
Supply and Laying in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 35 Sqmm 3.5 core complete all as specified and directed.
Supply and Laying in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 25 Sqmm 4 core complete all as specified and directed.
Supply and Laying in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 16 Sqmm 4 core complete all as specified and directed.
Supply and Laying in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 10 Sqmm 2 core complete all as specified and directed.
M&L for replacement of existing unsv cable end terminal joints with new cable end terminal joints (heat shrinkable) any type along Pole/panel etc. suitable for XLPE 1100 Volts aluminium conductor cable of size 120-185 Sqmm 3.5 core and testing after jointing. Note:- Rate quoted including necessary excavation, returning filling, removal etc for taking out loop/ cutting of burnt cable for required length for making end joint.
All as per item No. 22 but for cable size 50-95 Sqmm 3.5 core
All as per item No. 22 but for cable size 16-35 Sqmm 3.5 core
M&L for replacement of existing unsv cable straight through joints with straight through joints (heat shrinkable) any type suitable for XLPE 1100 Volts aluminium conductor cable of size 120-185 Sqmm 3.5 core and testing after jointing. Note:- Rate quoted including necessary excavation, returning filling, removal etc for taking out loop/ cutting of burnt cable for required length for making end joint.
All as per item No. 25 but for cable size 50-95 Sqmm 3.5 core
M & L for drilling suitable dia horizontal bore holes for insertion / laying of 40/50/100 mm bore GI tubing of any description below/under road surface/floors etc with using mechanical or manual devices as required at site including making good disturbed surface to match with the existing streta after laying pipes complete all as specified and directed
M&L for replacement of existing unsv Bus Bar Panel with new Bus Bar Panel of capacity 400 Amps copper bus bar 04 Nos with fixed on insulator welded with iron angle of size 50 x 50 x 6 mm thick grounting in floor, 0.45 mm depth grounting with PCC 1:3:6 upto ground level all as specified and directed. Cat Part No IHBC040004 of Make-Havells or equivalent in Legrand/L&T
M&L for replacement of existing unsv Bus Bar Panel with new Bus Bar Panel of capacity 250 Amps copper bus bar 04 Nos with fixed on insulator welded with iron angle of size 40 x 40 x 6 mm thick grounting in floor, 0.45 mm depth grounting with PCC 1:3:6 upto ground level all as specified and directed. Cat Part No IHBC025004 of Make-Havells or equivalent in Legrand/L&T.
M&L for replacement of existing unsv Bus Bar Panel with new Bus Bar Panel of capacity 200 Amps copper bus bar 04 Nos with fixed on insulator welded with iron angle of size 40 x 40 x 6 mm thick grounting in floor, 0.45 mm depth grounting with PCC 1:3:6 upto ground level all as specified and directed. Cat Part No IHBC020004 of Make-Havells or equivalent in Legrand/L&T.
M&L for replacement of existing unsv Bus Bar Panel with new Bus Bar Panel of capacity 100 Amps copper bus bar 04 Nos with fixed on insulator fixed on pole with bracket made out of FI of size 25 mm x 3 mm- 02 Nos including providing nut, bolt and washers, all as specified and directed. Cat Part No IHBC010004 of Make-Havells or equivalent in Legrand/L&T.
Clearing of bushes/small plants upto root level around and surroundings areas E/M installations (i.e. Two Pole/ Four structures, outdoor-substation yards & other Misc E/M installations etc.) soft and loose soil including surface dressing n.exc 15 cm deep and removing debris to a distance n.exc 50m complete all as directed
Restringing (without taking down) of existing ACSR’s conductorsand earth wires including cradles, of any description, size & shape and in any position, as in LT/HT overhead lines, on existing poles, including opening of connections and binding wires, restringing and tightening of conductors/earth wire in position, removing sag, binding to insulators with new aluminum wire, making and connecting jumper connections etc. including testing complete all as specified and directed. The quoted rates shall be deemed to include the following provisions also :- (i) Setting/adjusting etc in position of cradles. (ii) Old serviceable spacers of ACSR conductor shall be reused and fixed as directed by Engineer-in-Charge.
Material & labour pin type porcelain, vitreous, white, brown or green insulator including one GI nut bolt 100 mm height 65 mm dia for 1100 Volt complete including taking down old unserviceable insulator all as specified and directed.
Material & labour Shackle type, porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts for 1100 Volt 100 mm height & 115 mm dia with GI straps 31x5 mm & dia of volt 14 mm complete including taking down old unserviceable insulator complete all as specified and directed.
M&L for danger notice plate of size 20 cm x 15 cm x 1.6 mm thick mild steel sheet viterous enamelled white with letters figures and conventional skul and bones in signal red colour and fixed with MS clamps, bolts, nuts and washers of approved size for LT , 415 volts complete all as specified and directed.
M&L for prepration of old painted surface of steel tubular poles of 9 mtr long including cross arms, cable protection pipe, bus bar box and painting of complete area with one coat of aluminum paint from 1.5 mtr above ground level to top of pole and a height of 1.5 mtr from the ground level synethetic enamel paint in alternate strips / layer (30 cm wide) with white and blue colour including writing the pole number in white letters on black background and cleaning /cutting the grass/bushes at a radius of 2 mtr surrounding the pole all as directed.
M&L in replacement of existing unsv MCCB 250 Amps current carrying capacity 36 KA, AC 415 Volts Ics= 100% Icu, four pole with magnetic/ thermal adjustable type setting complete all as specified and directed.
M&L in replacement of existing unsv MCCB 160 Amps current carrying capacity 25 KA, AC 415 Volts Ics= 100% Icu, four pole with magnetic/ thermal adjustable type setting complete all as specified and directed.
M&L in replacement of existing unsv MCCB 63 Amps current carrying capacity 16 KA, AC 415 Volts Ics= 100% Icu, four pole with magnetic/ thermal adjustable type setting complete all as specified and directed.
Trimming up of tree branches upto 3 mtr all around LT overhead lines, removing cut branches from site as directed. Note :- (i) The overhead lines will be kept clear from all trees by trimming of tree branches with 3 mtr all around the line. (ii) Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department.
M&L for replacement of existing UNSV sign board with new sign board of size of 6 x 4 feet box type in cuboid shape made out of acrylic sheet on both side framed with stainless steel pipe including writing alphabatic letters of height 150 mm computerised with refelctive sheets providing LED 20 Watts tube light fitting - 02 Nos inside the box to be made all as directed and fixed with stainless steel pipe heavy duty 50 mm dia and to be fixed outside the installations including making all electric connections using 4 sqmm multi stranded aluminium cable as required at site duly burried in ground along with required PCC and top of the sign board should be 2.3 mtr above GL complete all as directed and specified. Note: Excavation, PCC removing extra soil etc. is deemed to be included in the rates quoted
M&L in replacament of existing old unsv earthing with steel earth plate electrode of size 600x600x6mm thick buried directly in ground to a depth not less than 3.25 mtr deep below normal ground level with top edge of the earth plate not less than 2.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earth lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate, 40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe light grade with funnel and wire mesh, complete all as per SSR with PCC chamber, 50mm thick RCC cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way, adequate qty of charcoal dust and salt layers all around the earth plate, including earth work in any type of soil, removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed.(Note: Excavation and earth work is deemed to be included in the rates quoted).
Taking down existing old unsv LT panel board with all accessories and Supply, installing, erecting, commissioning and testing new factory made LT panel board cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement, panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including TPN copper bus bar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation 0.45 mtr above floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :-
Taking down existing old unsv LT panel board with all accessories and Supply, installing, erecting, commissioning and testing new factory made LT panel board cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including TPN copper bus bar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :-
M&L for dismantling the cable connections of four pole/ three pole Air circuit breaker of capacity upto 1000 Amps, 415 V, 50 Hz of Make Legrand/ CG/ L&T/ABB/ Havells/ C&S, strip opening the Air circuit breaker, inspecting the parts for serviceability/ overhauling complete and carrying out the following maintenance:- a) Cleaning the insulation parts including bushings with CTC solution. b) Checking the alignment and condition of movable and stationary contacts and adjust them all as per manufacturer's instructional manual. c) Check the bolts, nuts, washers, cotter pins and all terminal connections are in place and tights. Replace the worn-out parts. d) Check arc chutes for damage. e) Clean and lubricate the operating mechanism with a light machine oil for pins and bearings and with a non-hardening grease for the wearing surfaces. Adjust breaker operating mechanism all as per manufacturer's instructional manual. f) Checking / inspecting shunt trip coil for serviceability and replacing the same if required. g) Checking control device free for operation. j) Check after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functional.
S&L/ fixing to wall/hanger in replacement of unsv 1100 volts grade heavy duty PVC insulated aluminium conductor, served with inner sheathing of PVC in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire one twin core cable of size 10 Sqmm multi-strand complete all as specified and directed .
CHAHAR CONTRACTOR AND SUPPLIERS
Balaji Associate
M/s S.M. Construction
MUKTA AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .