GE I R and D Chandipur
GE I R and D Chandipur, Post- Chandipur, PIN-756025
REPAIR MAINTENANCE OF PACKAGE CENTRAL AIR CONDITIONING PLANTS AND CONNECTED WORK AT TECHNICAL AREA OF ITR CHANDIPUR AND REPAIR OF SUMMER APPLIANCES AND VOLTAGE STABLIZERS IN TECH AND LCS AREA AT CHANDIPUR
2021_MES_487217_3
8680/CDP
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chandipur
As per tender documents
7 documents required · 7 mandatory
₹500
GE I R and D Chandipur
₹70,000
Yes
12 Mar 2022
22 Jan 2022
19 Feb 2022
22 Jan 2022
17 Feb 2022
31 Jan 2022
Amount
NOTE (Applicable for all items) :- The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A' PART-I
M&L for dismantling and overhauling of condenser/Chiller water pump set of capacity 15 HP, dismantling pump and motor separately, cutting the burnt out winding from slots and rewinding the same by existing size and gauge of super enamalled copper wire including varnishing, heating, repairing the insulating materials, repalcing bearings, bushes and remetalling the shaft including necessary heat treatment , and repairing the pump , including replacing the gland packing , bearings and all rusted nuts and bolts, washers and remetaling the Impeller of suitable size and bore for lifting the water from source and reassembling the motor and pump with gland packing includings painting of pump amd motor assambly complete with two coats of super enameled paints over one coats of red oxide, fixing the motor & pump at its position and connecting the suction and delivery water pipe and testing under working conditions, complete all as specified and directed.
All as per Sl Item No. 1.01 here- in- before but of capacity 12.5 HP squirrel cage induction motor . (Make-Siemens/CG/Kirloskar/Beacon)
All as per Sl Item No. 1.01 here-in-before but 10 HP capacity.
All as per Sl Item No. 1.01 here- in- before but 7.5 HP Capacity.
All as per Sl Item No. 1.01 here- in- before but 5.0 HP Capacity.
All as per Sl Item No. 1.01 here- in- before but 3.0 HP Capacity.
All as per Sl Item No. 1.01 here- in- before but of capacity 1.5/2 HP
M&L for repair and servicing to squirrel cage induction motor 3 phase 415V, 12.5 HP Kirlosker make or any others make by dismantling of motor from the pump set removing the stater/rotor separately, cleaning, varnishing, heating and drying re-erecting, aligning with the pump, testing, including replacing the bearing and bush, polishing and re-metalling the shaft including necessary heat treatment. Reassembling the motor and pump with new gland packing, supply and fix new gland nuts, bolts, with gland mounting nuts & bolts washers complete , painting the motor and pumps with two coats of synthetic enamel paint after preparing the surfaces all as directed by Engineer-in-charge. fixing the motor & pump on their own base and connecting the suction and delivery water pipes and testing with proper working condition complete all as directed .
All as per Sl Item No. 1.08 above but induction motor of capacity 10.0 HP.
All as per Sl Item No. 1.08 above but induction motor capacity 7.5 HP.
All as per Sl Item No. 1.08 above but induction motor capacity 5.0 HP.
All as per Sl Item No. 1.08 above but induction motor capacity 3.0 HP.
All as per Sl Item No. 1.08 above but induction motor capacity 2/1.5 HP.
Supply Fabricate and fixing of MS angle/MS plate/flat/rod for cooling tower frame, CT fan base, cooling tower ladders, and all supports made out of suitable size along with welding/MS nuts, bolts and washers, hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removimg existing unserviceable rusted one ,all as specified and directed by Engineer-in-Charge
M & L for dismantling and taking out unserviceable and defective parts of compressor of chiller Units of Central type AC Plants of capacity 25 to 50 TR of any make,and model after disconnecting the discharge & suction line removal of necessary electrical connection etc. Dismantling compressor body complete and carry out the repair work as per the following :- (a) Repairs to crank shaft, connecting rod, piston, piston pin valve plate by remetaling, cutting/grinding and polishing as required and by supply and replacing all spare parts with new one as required and directed. (b) Repairs /fixing by replacing of all new discharge and suction reeds, big end and small end bush, all bearing, all piston rings, capillary drier cum filter with new one all as specified and directed . (c) Repairs/fixing by replacing of all new kinds of gasket, washers, scappring made of Nylon/ Tuflon sheet/ rubber/fibre sheet as required with new one and all as directed. (d) Repair of Oil pump kit by , dismantling and cleaning, greasing oiling along with new gasket all as required and directed. (e) M & L for Repair/replacement of old u/s copper pipe line as per existing size and shape when found leaking/damage at the time of leak check including necessary flairing, brazing as required and replacement of end fittings made of copper including brass flange nuts, brass dead cap and brass pipe as per site requirement and as directed.( Note : - The cost of new Copper pipe is also included in the same job ) (f) Supply and fix in repair of all u/s rusted bolts, nuts and washers of any kind/made of any metalical/any size and shape as per site requirement with new one all specified and directed. (Note :- The cost of all types/sizes of new nuts , bolts and washers are included in the same job. (g) After the repair work re-assembling the plant and check for leak in system with the help of Nitrogen gas. in case of any leak is detected the repair is to be carried out without any extra cost nitrogen/refrigerant gas. (h) After leak repair release Nitrogen and charge with refrigerant gas and testing to be carried out. Note : The cost for Nitrogen gas for Leak test, Charging/top up of Compressor oil and refrigerant gas (R-22) and necessery spares will be measured & Paid separately against respective items of this schedule.
Supply only Suction reed as per existing make and model .
Supply only Discharge reed as per existing make and model.
Supply only Main Bearing as per existing make and model
Supply only Thrust Bearing as per existing make and model
Supply 0nly Piston Pin as per existing make and model.
Supply only Piston as per existing make and model.
Supply only Piston Ring as per existing make and model
Supply only Discharge and Suction Ring as per existing make and model.
Supply only Gasket Set asper existing make and model
M &L for Carrying out cleaning and de-scaling of iron deposited in condenser shell and tube and outside of the shell and tube of condenser by using chemical suitable for Descalling for the condensor unit of the compressor with the help of monoblock pump set , recommended by manufacturer manual of the respective plant by using complete with satisfactory for Capacity 3x26TR central type Scroll chiller AC Plant at PP Buildings , all specified and directed by Engr - in charge. ( Make : Blue Star or Equivalent as approved)
All as per Sl Item No. 1.25 here -in-before but compressor of capacity 3x27.5 TR at TIC (Knowledge Centre) Buildings (Make : ACCEL or equivalent as approved)
All as per Sl Item No. 1.25 here -in-before but compressor of capacity 3x 30 TR at AC Magzine Buildings (Make : VOLTAS or equivalent as approved)
All as per Sl Item No. 1.25 here -in-before but compressor of capacity 3x90 TR at New MPO Buildings (Make : Carrier or equivalent as approved)
Pressure testing / leak arresting , vaccumising with dry nitrogen gas / oil charging, incl replacing the unserviceable strainers all as required and testing complete for Central type AC plant of capacity 25 to 50 TR TR at location/building of ITR tech area and LC area. Note :- Refregerant Gas R-22 and strainers will be measured and paid seperately under suply only items
Pressure testing / leak arresting , vaccumising with dry nitrogen gas / oil charging, incl replacing the unserviceable strainers all as required and testing complete for Package type AC plant of capacity 5.5 TR to9 16.5 TR at any location/building of ITR tech area and LC area. Note :- Refregerant Gas R-22 and strainers will be measured and paid seperately under suply only items
Supply only for Recharge/Top up refrigerant R- 22 (Mefron) or equivalent in Central type AC Plants of various capacities complete all as directed .
Supply only for Recharge/Top up refrigerant R- 410/413/407C or equivalent in various type of Package/Central type AC Plants of various capacities complete all as directed .
Supply and charging/top up of compressor oil in various central type AC plants, Type : HPL-68 or equivalent as per existing sample (Make : SERVO/INDIAN OIL or equivalent as approved)
M & L for Supply , assembly and erection of GSS duct 120 GSM rectangular/ Square boxed, incl all accessories such as MS Angles frame at ducts joints for support of ducts , corner, cleat, carriage bolt Gasket and appropriate sealant on longitudinal joints etc comlpete of size 20 SWG icluding taking down unserviceable part and all as directed at site .Make :- SAIL/TATA/JINDAL
M&L for exposed duct thermal insulation with 50 mm thick thermocol including other binding like CPRX for fixing/bonding of thermocol and plastic and hassain clothes as covering mterials and finished with cement mortar / lath plaster with the help of wire mess of appropate size and finally painting two coat with suitable materialslike samosan / distamper or any other water resistance materials to match with existing surface complete all as specified and directed including taking down old unsv materials.
M&L for painting to complete chilled water type Central Air Conditioning plant of 3X30 TR capacity at AC Magzine, including complete chiller unit, compressor, motor, condenser refrigerant pipe, water pipe, chilled water pipe line, AHU, cooling tower, LT panel board complete plant with two coat of synthetic enamelled paint including preparation of surfaces and as per colour code all as specified and directed by Engineer - in - charge .
All as per Sl Item No. 1.36 above but for 3X 27.5 TR chiller type AC Plant at TIC Building
Servicing of electric control panel/compressure control pannel board by taking out the burnt wire. Supply & fixing new wire of existing specification with clipping and socketing and dressing properly complete including replacement of the unserviceable spares. Note-U/S spares to be measured and paid seperately as supply only items under this schedule .
S&F in repair oil seal, O ring, carbon bushing of shaft of central Type AC Plants compressor of 27.5 TR capacity . (Make-ACCEL, model-SMC-8-65 or equivalent as approved)
All as per Sl Item No. 1.39 above here in before but 30/35 TR capacity. ( Make-VOLTAS/ACCEL)
S&F MS pipe 100 mm dia heavy grade with all fittings laid in floors or fixed to walls and ceilings including taking down old MS pipe for Central AC Plant (Make : Tata steel/Jindal steel)
S&F MS pipe 80 mm dia heavy grade with all fittings laid in floors or fixed to walls and ceilings including taking down old MS pipe for Central AC Plant (Make : Tata steel/Jindal steel)
S&F MS pipe 65 mm dia heavy grade with all fittings laid in floors or fixed to walls and ceilings including taking down old MS pipe for Central AC Plant (Make : Tata steel/Jindal steel)
S&F in repair for Insulation of M S Pipe with PUF slab 30 mm thick and including applying bituminuous/CPRX compound and AluminiumI cladding sheet with 26 gauge complete for size 65 mm dia MS pipe
S&F in repair for Insulation of M S Pipe with PUF slab 40 mm thick and including applying bituminuous/CPRX compound and AluminiumI cladding sheet with 26 gauge complete for size 100 mm dia MS pipe
S&F in repair of refillable type drier filter suitable for central type AC Plant of capacity 26/27.5 /30/35 TR capacity. (Make: Voltas/carrier/Accel)
S&F in repair V Belt (A-52) for compressor motors ,CT fan motors, and blower motors (Make-FENNER/PALYP).
All as per Sl Item No. 1.47 above but for B-84 V belt.
All as per Sl Item No. 1.47 above but for B-86 V belt.
All as per Sl Item No. 1.47 above but for C-105 V belt.
All as per Sl Item No. 1.47 above but for SPA-1120 V belt.
S&F in repair entering water temperature(EWT) sensor suitable for 26 TR scroll type AC Plant.(Make: Blue star as per existing model ).
S&F in repair leaving water temperature(LWT) sensor suitable for 26 TR scroll type AC Plant.(Make: Blue star as per exixting model).
Supply and fixing of of PVC Fills of size (600x300x150mm), blue colour, sutable for any type of cooling tower of central air conditioning plant
S&F in repair electronic timer 3-30 sec ,5 A,24 volt AC (Cat No.HODT2COZ of GE or equivalent)
S&F in repair power contactor model no. MNX 25 for AC circuit with AC Coils voltage 220 Volt ,over load relay 25-45 Amps. (Make:Cat No.-CS94110 - L&T )
S&F in repair power contactor model no. ML 3 for AC circuit with AC Coils voltage 220 Volt ,over load relay 10-25 Amps ( Cat No.- SS90721,and 2NO+2NC front mounted block. (Make- L&T or equivalent as approved)
S&F in repair power contactor model no. ML 1.5 for AC circuit with AC Coils voltage 220 Volt ,over load relay 10-25 Amps (Cat No.- SS91851KOOO,and 2NO+2NC front mounted block. (Make- L&T or equivalent as approved )
S&F in repair air break contactor with one NO & NC. (Make-Model no. 3TF-34 of Siemens or equivalent of L&T)
S&F in repair of single phase preventer 40 Volts in balance VSP II.(Make-Minilec)
S&F in repair power contactor model no. MNX `12E 4 pole 10 Amps for AC circuit with AC Coils voltage 220 Volt , Make L&T
S&F in repair power contactor model no. MNX-12 4 pole 10 Amps for AC circuit with AC Coils voltage 220 Volt , Make L&T
S&F in repair Safety valve 300 PSI of copper material suitable for 25 TR to 90 TR capacity Central/package type AC plant (as per existing make and model)
S&F in repair thermometer 0-06 suitable for 25 TR to 90 TR capacity Central/package type AC plant (as per existing make and model)
S&F in repair Pressure gauge of maximum 20 Kg of pressure suitable for 25 TR to 90 TR capacity Central/package type AC plant (as per existing make and model)
Servicing and Maintenance including minor repairs and making in serviceable condition of the package type AC Plants of 5.5/7.5/11.0/16.5 TR capacity comprising of all minor parts and machineries including charging of R - 410/407/22 Gas and l when ever required repair and maint of compressor and blower motor Air filters de-humidifying coils lt control pannels , PCB, ducts and accessories of all gauges and meters and keeping in perfect working condution all as specified and directed by the Engr-in-charge .Note : Leak test,refrigerant Gas will be measured and paid seperately under relevent items of schudle if any required .
S&F in repair three phase Control PCB for package type AC plant of 5.5 TR Capacity, (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge.
S&F in repair three phase Control PCB for package type AC plant of 7.5 TR Capacity, (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge.
S&F in repair three phase Control PCB for package type AC plant of11.0 TR Capacity, (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge.
S&F in repair three phase Control PCB for package type AC plant of16.0 TR Capacity, (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge.
S&F in repair Air sensor for package type AC plant of 5.5/7.5/11.0 TR Capacity, (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge.
S&F in repair Coil sensor for package type AC plant of 5.5/7.5/11.0 TR Capacity, (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge.
S&F in repair PVC Cable/wire Connectorof size 20mm dia (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge.
S&F in repair PVC Cable/wire Connectorof size 25mm dia (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge.
S&F in repair fan capacitor of 10+-2% mfd capacity suitable for out door unit of package type AC plant of 5.5/7.5/11.0 TR Capacity, (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge.
Supply and fixing in repair 2.5 Core 3 Sqmm multistrand copper conductor PVC insulated sheathed flexible cable suitable for connection of package type AC plant.
Supply and fixing in repair 4 Core 10 Sqmm multistrand copper conductor PVC insulated sheathed flexible cable suitable for connection of package/central type AC plant.
Supply and fixing in repair MCB TPN 63 Amps for connection of package/central type AC plant as main incommer
Supply and fixing in repair MCB TP 40 Amps for connection of package/central type AC plant.
Supply and fixing, V belt of suitable sizes for 5.5TR capacity Package type AC plant blower motor . Make : FENNER/Dunlop
Supply and fixing for V belt of suitable sizes for 7.5 TR blower motor Make : FENNER/Dunlop
Supply and fixing for V belt of suitable sizes for 11.0 TR blower motor Make : FENNER/Dunlop
Supply and fixing for V belt of suitable sizes for 16.5 TR blower motor Make : FENNER/Dunlop
M & L for replacement of U/S canvas cloth of package/centraltype AC planrs including provisiong of zip 150 mm lenth for opening and closing arrangements and properlly fasterners with bolts and nuts between the ducts all as directed by the Eng-in-charge
Supply and fixing Flow swithch 25 mm dia suitable for 26 TR central AC plant all as specified and directed by engr in charge .
Supply and fixing GI tubing 40 mm bore medium grade with all fittings laid in trenches, floor, roof and wall and tank connection complete including cutting and thereading with all fittings like tee, elbow bend union reducer hex nipple etc and all as required at site and directed.
Supply and fixing GI tubing 25 mm bore medium grade with all fittings laid in trenches, floor, roof and wall and tank connection complete including cutting and thereading with all fittings like tee, elbow bend union reducer hex nipple etc and all as required at site and directed.
Supply and fixing GI tubing 20 mm bore medium grade with all fittings laid in trenches, floor, roof and wall and tank connection complete including cutting and thereading with all fittings like tee, elbow bend union reducer hex nipple etc and all as required at site and directed.
S&F in repairs gun metal gate valve ISI marked with iron wheel head, screwed both ends for iron pipe of 40 mm bore including taking down the unserviceable existing ones.
S&F in repairs gun metal gate valve ISI marked with iron wheel head, screwed both ends for iron pipe of 25 mm bore including taking down the unserviceable existing ones.
S&F in repairs gun metal gate valve ISI marked with iron wheel head, screwed both ends for iron pipe of 20 mm bore including taking down the unserviceable existing ones.
Supply and fix in repair PVC Ball valve (minimum wt 690 gms) ISI marked high presssure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of size 40mm bore and fixed.
Supply and fix in repair PVC Ball valve (minimum wt 690 gms) ISI marked high presssure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of size 25 mm bore and fixed.
Supply and fix in repair PVC Ball valve (minimum wt 690 gms) ISI marked high presssure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of size 20 mm bore and fixed.
SCHEDULE 'A' PART-II
Taking out unserviceable Receprocating type compressor of Window /Split Type AC 1.5 Ton capacity, from site and replacement of compressor with new one to match with existing make/Model (R Compressor) and fixing of new compressor sealed unit in position, charging required quantity of refrigerant gas R-22/R-134a as per existing design of AC, brazing of discharge and suction line including leak testing complete as directed by the Engineer-in-charge Make :- Kirlosker / Hitachi / Hillie / Copeland / Danfoss. Note: Cost of copper capilary of any sizes, rubber pad bushing, modification work for fixing new compressor etc required for completing the repair is deemed to be included in the cost.
All as per Sl Item No. 2.01 above but Window /Split type AC 2 TR capacity.
Taking out unserviceable Rotary type compressor of Window/ Split Type AC 1.5 Ton capacity, from site and replacement of compressor with new one to match with existing make/Model (R Compressor) and fixing of new compressor sealed unit in position, charging required quantity of refrigerant gas R-22/R-134a as per existing design of AC, brazing of discharge and suction line including leak testing complete as directed by the Engineer-in-charge Make :- Kirlosker / Hitachi / Hillie / Copeland / Danfoss. Note: Cost of copper capilary of any sizes, rubber pad bushing, modification work for fixing new compressor etc required for completing the repair is deemed to be included in the cost.
All as per Sl Item No. 2.03 above but Window /Split type AC 2 TR capacity.
M/L for Gas charging with R-22 refrigerant gas for Split / Windows ACs of any make, model and capacity, Refrigerator and Water coolers of any make, Model of any capacity in position or by taking down including leak testing to achieve desired suction pressure and temperature and all as directed by Engg-in-Charge. Note: Leakage or loss of gas due to imperfect workmanship will not be measured. Only the qty of gas utilised as per design of machine will be measured after successful gas charging.
M/L for Gas charging with R-407/R-410/R-410A refrigerant gas for Split / Windows ACs of any make, model and capacity, Refrigerator and Water coolers of any make, Model of any capacity in position or by taking down including leak testing to achieve desired suction pressure and temperature and all as directed by Engg-in-Charge. Note: Leakage or loss of gas due to imperfect workmanship will not be measured. Only the qty of gas utilised as per design of machine will be measured after successful gas charging.
Cleaning, servicing including carrying out preventive maintenance of summer appliances viz. indoor and out door unit of Split Air conditioners and complete unit of Split Type AC 2.0 TR Capacity using suitable cleaning solution, chemicals, tools and minor spares viz. screws, washers, insulation tapes, thimbles, PVC fasteners etc. as per site requirement and as directed. Cleaning of the condensor, evaporator, fins and cooling coils shall be done using Blower / Vacuum cleaner, cleaning clothes, nylon brushes etc till scales and dirts are removed including cleaning of drain pipe line and replacement of unserviceable spares if any and ensuring its serviceability by keeping the AC in good working condition all as specified and directed by Engineer-in-Charge. Note :- 1. During servicing work, if any major fault is observed, the machine will be repaired under respective item of the schedule under Supply and fix in repair work, and thereafter servicing will be undertaken and completed. 2. Spares required for repair of unserviceable machines if any will be measured and paid under respective item of this schedule as "Supplied only" items. However, for servicing work, cost of minor spares to be replaced if any and not specified in this schedule viz. screws, washers, teflon seal, rubber bush, insulation tape, copper thimble, copper connecting jack, short length connecting wire, markers etc upto Rs 100 is deem to be included in the rate of the item. 3. Cost of taking down, reinstallation and transportation if required for the servicing / repair work is deem to be included in the price. 4. Servicing and repair work will be carried out within the contract period as and when required as per the site requirement and as directed by Engg-in-Charge.
All as per Sl Item No. 2.07 above but Split Type AC 1.5 TR Capacity
All as per Sl Item No. 2.07 above but Window type AC 1.5/2 TR Capacity
All as per Sl Item No. 2.07 here-in-before but for Water cooler of any capacity , make and model. The inner water tank of water cooler should be cleaned using bleaching powder and keeping the inner tank clean from bacteria and formation of scales and ensuring its serviceability all as specified and as directed by Engineer-in-Charge.
All as per Sl Item No. 2.07 here-in-before but for Refrigerator of any capacity, make and model. The inner water tank of water cooler should be cleaned using bleaching powder and keeping the inner tank clean from bacteria and formation of scales and ensuring its serviceability all as specified and as directed by Engineer-in-Charge.
Supply only thermostat for water cooler / refrigerator / deep freezer of any capacity and make.
Supply only relay for any type of water cooler /refrigerator/deep freezer of any capacity & make.
Supply only PCB suitable for split type A/C 1.5 TR capacity of any make/ model
Supply only PCB suitable for split type A/C 2 TR of any make.
Supply only Digital Display Unit suitable for split / window type A/C 1.5/ 2 TR of any make and model.
Supply only Air sensor suitable for split / window type A/C 1.5/2.0 TR of any make/ model
Supply only Coil sensor suitable for window / split type A/C1.5/ 2 TR of any make/ model
Supply only Running capacitor 45+5 mfd for Window / Split type Air conditioner of of any capacity.
Supply only Running capacitor 60+5 mfd for Window / Split type Air conditioner of of any capacity.
Supply only Running capacitor 36 mfd for air conditioner of any capacity & water cooler of any capacity
Supply only Running Capacitor capacitor 50+5 mfd for Air conditioner 2 Ton Capacity
Supply only Capacitor of 2.50 mfd capacity suitable for all split / wiondow type AC Blower Fan of any make and model .
Supply only capacitor of 4.0 mfd capacity suitable for all split / wiondow type AC Blower Fan of any make and model .
Supply only capacitor of 6.0 mfd capacity suitable for all split / wiondow type AC Blower Fan of any make and model.
Supply only auto swing motor for indoor unit of split A/C of capacity 2/1.5 TR of any make and model to match with existing design conditions.
Supply only Power contactor suitable for Split AC of 3.0 TR capacity of any make and model to match with existing design conditions.
Supply only Brass angle valve of size 5/8 inch for split AC 1.5/2TR capacity.
Supply only Brass angle valve 1/4 inch for split AC 1.5/2TR capacity.
Supply only Brass angle valve 1/2 inch for split AC 1.5/2TR capacity.
Supply only Nitrile Foam Insulation for copper tube of size 5/8 inch suitable for split AC including provision of requisite PVC fasteners.
Supply only Nitrile Foam Insulation for copper tube of size 1/4 inch suitable for split AC including provision of requisite PVC fasteners..
Supply only Nitrile Foam Insulation for copper tube of size 1/2 inch suitable for split AC including provision of requisite PVC fasteners..
Supply only PVC ball valves / float valve for water cooler of any capacity & make
Supply only brass chromium plated push button tap outer / Inner thread ISI marked suitable for water cooler of any type of size 15 mm.
Supply only Thermostat for Window AC of capacity 1.5 TR/2.0 TR to match with existing design conditions.
Supply only relay of model 1622Y suitable for Window type AC of any capacity and to match with existing design conditions..
Supply only Over load relay of 16 Amps capacity suitable for Window type AC of any capacity and to match with existing design conditions..
Supply only Remote Universal type suitable for all type of split / window AC of any make and model or any capacity and to match with existing design conditions..
Supply only PVC Drain pipe of size 1/2" size suitable for Split type AC of any capacity.
Supply only , main Drain pipe of indoor unit of size 3/4 ", PVC Flexible type suitable for Split type AC of any capacity.
Supply only Rubber Bush for Fan Motor of out door unit of split type AC and Window type AC of any capacity and any make and model .
Supply only Flairing Nuts of Size 5/8 for out door unit of Split type AC of Any make and model.
Supply only Flairing Nuts of Size 1/2 for out door unit of Split type AC of Any make and model.
Supply only Flairing Nuts of Size 1/4 for out door unit of Split type AC of Any make and model.
Taking down unserviceable Fan Motor of Window / Split type AC 1.5/2.0 TR capacity and of any make and model, removing burnt winding, insulation material, cleaning the surfaces, rewinding the motor with super enameled copper winding wire of same gauge and size including insulation material and varnishing and re-fixing at site all as directed by Eng-in-Charge.
Taking down unserviceable Condenser fan motor of water cooler/refrigerator/deep freezer of any capacity, make and model, removing burnt winding, insulation material, cleaning the surfaces, rewinding the motor with super enameled copper winding wire of same gauge and size including insulation material and varnishing and re-fixing at site all as directed by Eng-in-Charge.
Supply and fixing in repair, Out door Bracket ISI marked suitable for fixing out door unit of Split type ACs of any make and capacity along with MS clamps, bracings, supports, bolts, nuts & washers, PVC rawl plug etc and making good disturbed surface of wall in CM 1:3 including painting to match with existing surface and all as directed.
Supply and fixing in repair Condenser Fan motor ISI marked of window/split Ac of any make and capacity and water cooler of any capacity, make and model and all as directed.
Supply and fixing in repair Blower Fan motor assembly of indoor unit of split AC 1.5/2TR of any make and model and all as directed.
Supply and fixing in repair Condenser Fan Blade marked suitable for 1.5 / 2 Ton Split Type Air conditioner of any make and model and all as directed.
Supply and fixing in repair Fan Blade suitable for Water Cooler of any capacity / Make and model and all as directed.
M/L for carrying out spray painting complete unit of window type AC of any make, model and capacity after dismantling, and painting on sheet metal enclosers interanally and externally with two coats of synthetic enamel paint of approved make and shade after preparation of surface and writing the MES/SM Nos, re-assembling and reconnecting the AC unit at its installed location complete all as directed.
All as per Sl Item No. 2.55 above but for outdoor unit of split AC of any capacity make and model.
Supply and fixing in repair Copper Condenser Coil ISI marked suitable for Window type AC of 1.5TR capacity of any make and model to match with existing design conditions.
Supply and fixing in repair Copper Condesser Coil ISI marked suitable for Window type AC of 2.0 TR capacity of any make and model to match with existing design conditions.
Supply and fixing in repair Copper Condesser Coil ISI marked suitable for Split type AC of 1.5 /2.0TR capacity of any make and model to match with existing design conditions.
Supply and fixing in repair Cooling Coil suitable ISI marked for Window type AC of 1.5 TR capacity of any make and model to match with existing design conditions.
Supply and fixing in repair Cooling Coil ISI marked suitable for Window type AC of 2.0TR capacity of any make and model to match with existing design conditions.
Supply and fixing in repair 4 Core 4 Sqmm multistrand copper conductor PVC insulated sheathed flexible cable suitable for AC / water cooler / Refrigerator / AC / Voltage stabilizer.
M &L for Sub main wiring in PVC conduit of required size 2 run of 6 sqmm PVC insulated copper conductor cable wih one run of 4 sqmm PVC insulated copper conductor cable as continuity earth wire, including taking down existing old unsv point wiring , all as speified and directed .
Supply and fixing in repair /replacement of MCB Protected Power unit comprising of suitable capacity SPN MCB, 3 pin Socket and On/Off Motor Starter suitable for controlling AC and including making good to existing disturbed works completete all as directed and specified, and taking down old unserviceable plug socket for offering credit.
M&L for Earthing in repair complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to galvanised iron strip 25 mm x 4 mm as earth lead by means of bolts, nuts, check nuts & washers etc, GI earth lead strip duly protected by and including 40 mm dia GI pipe (light grade) and 20 mm GI pipe (medium grade) for watering and connected to control switch as directed including necessary earth work in soft /loose soil and disposal of excavated soil to a distance not exceeding 50 m, PCC(1:3:6) type C1 as in concrete pit, 50 mm thick precast RCC (1:1.5:3) type A1as in cover slab duly reinforced with 8 mm dia TMT bar @ 100 mm c/c both way and two nos lifting handle made cut of 10 mm dia TMT bar and set in cement mortar (1:4) , funnel, and salt , in alternate layer, testing etc complete and as specified in electrical plate No 3 of SSR Part-I including taking down old earthing pit.
Supply and fixing in repair Electronic Circuit Board Suitable for Out door unit of Split type AC 1.5/2.0 TR (Voltas Inverter model ) and all as per Existing make and model , All as specified and directed by Engr - in - Charge
Supply and fixing in repair Electronic Circuit Board Suitable for Indoor unit of Split type AC 1.5/2.0 TR (Voltas Inverter model ) and all as per Existing make and model , All as specified and directed by Engr - in - Charge
ALLIANCE
Bansal And Co
M/s R.C REFRIGERATION
Shree Mahavir Associates
Bidder Name
ALLIANCE
Bansal And Co
M/s LADHANIA BROTHERS
M/s R.C REFRIGERATION
Shree Mahavir Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .