Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC | L1 | Accepted-AOC Bing lowest tenderer | |
| 2 | L2₹38.9 L+₹1.7 L (4.68%)Rejected-Finance A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | L3₹39.3 L+₹2.1 L (5.72%)Rejected-Finance FLAT NO 002 GROUND FLOOR MAHAVIR VILLA C H S PLOT NO 259 SECTOR NO 21 NERUL E NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-Finance Being other than lowest tenderer | |
| 4 | L4₹41.2 L+₹4.1 L (11.0%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest tenderer |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
16 Mar 2020, 6:00 pmClosed
GE (NW) KUNJALI
DR HOMI BHABHA ROAD, NAVY NAGAR, COLABA, MUMBAI-400005
8261 SPECIAL REPAIRS TO ROOF OF HEADQUARTERS WESTERN FLEET OFFICE BUILDING P194 ADDITION ALTERATION TO OLD INDUSTRIAL WINDOWS IN C NO 08 SYS DEPARTMENT BUILDING NO P 188 ADDN ALTN TO FIRE ESCAPE LADDER AT HEADQUARTER WESTERN FLEET OFFICE BUILDING P 1
2020_MES_318305_3
8261/E8
Open Tender
Civil Works
Item Rate
275 days
GE (NW) KUNJALI
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹95,000
Yes
20 Apr 2020
2 Mar 2020
18 Mar 2020
2 Mar 2020
16 Mar 2020
2 Mar 2020
2 Mar 2020 - 2 Mar 2020
Amount
Dismantling wrought iron or mild steel work of any description not otherwise specified for complete all as specified and directed
Dismantling asbestos cement (corrugated, semi-corrugated etc.) sheets in roof covering complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing) and remove outside MD land complete all as specified and directed.
Taking down cement plaster on brick /concrete surfaces built in cement mortar including raking out joints, backing for key scrubbing down with water etc complete all as specified and directed.
Disconnecting existing tanks, 5000 litres capacity, setting aside (or lowering if required) for repair, cleaning, etc and hoisting if required reconnecting and re-fixing in position.
M&L for Cutting chases in brick work for inserting water proofing membrane in to the parapet walls/column & making good to facing wher required and pointing in CM 1:3 to the groves, cutting n exc. 10 cm girth complete all as specified and directed.
All as per Srl itemNo. 6 here in before but cutting in concrete n exc. 10 cm girth.
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finishing the surface even and smooth without using extra cement all as specified and directed.
M&L for rendering 5 mm thick in CM 1:3 on fair faces of brick work or concrete surfaces in ceiling finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for plastering in CM 1:4, 20 mm thick in two coats (15 mm under coat plus 5mm finishing coat) with water proofing compound at the rate of 2% by weight of cement and finishing the surface even and fair complete all as specified and directed. (WPC will be measured and paid seperately).
M&L for sagol finish on newly plastered surfaces of wall / ceiling, to a thickness not less than 1mm trowlled to an even and smooth finish complete all as specified and as directed.
S&F cold rolled mild steel sections (angles) as in rafters, purlin etc. fixed with angle cleat or other connecting plates, conforming to Fe-410-W (Gde-250, quality-A) complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI baseds corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L for PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate, as roof kerbs / padding, with WPC @ 2 % by weight of cement, etc complete all as specified. (WPC will be measured and paid seperately).
M&L for the roof / floor surface thoroughly wire brushed, washed and dried up and cleaned of all foreign matter and dust to receive bituminous primer, apply bituminous based cold applied primer @ 270 to 300 gms/Sqm manufactured by the same agency as that of APP all as per manufacturers instructions. Laying 5 layered, 4 mm thick APP (A tactic poly propylene) modified membrane reinforced with 180 GSM (Gms/Sqm) of non woven polyester mat, applied by thermo fusion using LPG torch on the bottom portion of the membrane with an overlap of 75mm in longitudinal direction for accessible roof complete all as specified and directed.
M&L for cement concrete tiles 20CmX20CmX25 mm thick, machine pressed, set jointed and pointed in neat cement slurry in floors over and including 15 mm thick bedding layers in CM 1:6 complete all as specified and directed.
S&F 40 mm dia medium grade galvanized steel tubing with all fittings fixed to walls, ceilings or laid under floors and including taking down exiting tubing and connections all as specified and directed.
Supply only integral water proofing compound.
M&L for preparation of new steel surfaces exc 10cm width of girth and applying two coats of enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old decorated steel surfaces of any description over 10 cm width or girth, applying a coat of synthetic eanmel paint complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall, applying two coats of oil emlusion distemper over a coat of alkali primer and primer putty complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls, applying three coats of white wash complete all as specified and directed.
All as per Item No. 22 above but in ceiling
M & L for preparation of newly plastered wall surfaces, over 10cm girth, applying two coats of anti-fungal , weather resistant emlusion over a coat of exterior wall primer complete all as specified and as per manufacturer's instruction.
M & L for preparation of old decorated wall surfaces, over 10cm girth, applying one coat of coats of anti-fungal, weather resistant emlusion complete all as specified and as per manufacturer's instruction.
M&L for aluminium anodized grill with suitable anodized aluminium frame of F/H section with suitable fixing screws / attachment etc complete all as per M/S Deco Grill Design No DG -102, 7.5mm size grill all as per manufacturer's specifications.
S&F solar control film 50 micron non reflective type, sticked to glass as per manufacturers instructions complete all as specified and directed. (Make - Garware or equivalent as approved by GE).
S&F powder coated aluminium frame / shutters for doors, windows, ventilators etc. including joining cleat for fixing, PVC rollers, locking arrangement, rubber beading, rubber gasket, screws, handles, hinges, tower bolts etc. complete all as specified. Make: JINDAL / HINDALCO / INDALCO. Note :- (i) Glazing and wire mesh shall be measured and paid separetely. (ii) Item shall be paid as per weight of aluminium section. (iii) the rate quoted shall be inclusive of the cost of neoprene beading, glazing pins, screws and powder coated fittings such as hinges, handles, locking arrangement etc. as required which shall not be measured for arriving the weight. (iv) The rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work and including matching the existing surface area.
M&L for complete removal of existing treatment on wall surfaces and applying two coats of Birla white cement and alkali resistance primer, sanding the surfaces and finally applying two coats of oil bound distemper complete all as specified and directed.
S&F for rolled mild steel sections of Grade Fe 410-W, (Gde- E-250) quality-A, as in post, runners, rafters, purlins etc fixed with connecting plates including bending, welding etc complete all as specified and directed.
S&F for rolled mild steel sections of Grade Fe 410-W, (Gde- E-250) quality-A, as in stairs (framed) including stringers, treads, landing, balusters, hand rails etc, including cleats, brackets including bending, welding etc complete all as specified and directed.
S&F for mild steel plates of Grade Fe 410-W, (Gde- E-250) quality-A as in connecting plates, base plate etc. welding etc complete all as specified and directed.
Taking down steel windows / ventilators / chowkhat / frame with shutters exc 1.5 sqm but not exceeding 4 sqm each (without taking off shutters from the frames) complete all as specified and directed.
Dismantling of wall panneling, partition and ceiling boards (fibre, pulp, insulation) or insulation boards, bonded wool, blanket slab incl aluminium grid frame work complete all as specified and as directed
M&L for 12 mm thick pre-laminated Medium Densityboard,both side decorative lamination interior grade,fixed in aluminium/ wooden frame work.
M&L 12mm thick plywood grade BWP, type BB fixed with screw to timber/aluminium frame work complete all as specified and directed.
M & L 0.9 mm thick Decorative texture finish laminate type 1, of surface finish, colour and pattern as approved, fixed with approved adhesive as per maker,s instructions.
S&F 12 mm thick Medium density fibre board, exterior grade, fixed to timber/ Aluminium frame work with screws
S&F aluminium anodised sliding door bolt 300m long, with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified and directed.
S&F Extrude aluminium anodised alloy handles, fabricated type 150mm size.
Removal of debries, old concrete, spoils etc exc. 5 Km complete all as specified and as directed outside MD land
Taking down carefully old U/S point wiring copper / Aluminum (light / fan / Sockets / power) complete with switches, sockets, fan regulators, ceiling roses, lamp holders, brackets, removing material form site and making good to disturbed surfaces complete all as specified and as directed.
Taking down old U/S MCB DBs complete with MCBs, isolator etc of any type and capacity from wall/ceiling etc & making good to the disturb surfaces all as directed all as specified
M&L for point wiring with FRLS PVC insulated, un-sheathed, multi stranded copper conductor cable of 1.5sqmm size, 1100volts, (Make: Havells/ Finolex/ Plaza) drawn through and including non metalic rigid PVC casing and caping not less than 25mm with all accessories fixed on wall//ceiling/truss including FRLS PVC insulated, unsheathed, multi stranded copper conductor cable of 1.5sqmm size as earth continuty conductor connected to common earth dolly including required numbers and size of PVC moulded box with cover plate in any size fixed on wall for fixing the switches, switch sockets, sockets, regulators etc complete all as specified for:- NOTE: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex / Plaza (c) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit.
One light point controlled by one 5A switch
One Fan point controlled by one 5A switch
One 5A flush type switch socket point on same board board
One 5A flush type switch socket point on independent board
M&L for point wiring complete with proper clour coding using PVC insulated unsheathed multistranded copper conductor cable 4.0 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 4.0sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including PVC modular box with cover plate complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex / Plaza (c) Switch socket measured & paid separately.
S & F modular switch 1 way 6A, 1 module complete all as specified and directed. Make: Anchor/Roma/Legrand.
S & F modular socket, 6A - 2/3 pin combined 2 modules complete all as specified and directed. Make: Anchor/Roma/Legrand.
S & F modular switch socket combination 6/16A, 2/3 pin, combined 2 module complete all as specified and directed. Make: Anchor/Roma/Legrand.
S&F for modular fan step regulator, 120W - 2 modular complete all as specified and directed. Make: Anchor/Roma plus/Legrand
S & F ceiling rose surface bakelite 65 x 50mm, flush type, 3 terminals complete all as specified and directed.
Supply and fixing in repair Ultra slim edge lit type recess mounting LED 2X2 Luminaire 36 watt and extruded aluminium housing with anti-glare diffuser provides high quality ecomonic energy saving lighting LED Luminaire suitable for 600 x 600 mm modular/POP/Gypsum ceiling complete all as specified and as directed. Make: Crompton cat No LCPL-36-CDL(2X2) / C&S cat No LTCRSLM36WATT2X2 or equivalent Cat part in Surya / Philips
S&F in repair of vertical type TPN DB 4 Way, 415V with 200A busbar, double door type, IP43- IK 09 protection suitable for housing MCB's all as specified and directed. Make: Legrand cat No 5077 30 or equivalent cat No. in Seimens/GE.
S&F in repairs of MCCB sheet metal enclosure for holding MCCB of up to 160 Amps capacity four pole type including fixing accessories etc. complete all as specified and directed. Make :Legrand cat No 5078 01 or equivalent cat No. in Standard/GE/Seimens/C&S
S & F MCB SP 63 Amps,10KA 'C' Curve 240V complete all as specified and directed. Make: Legrand cat No 4085 98 or equivalent Cat part in Seimens/GE.
S & F MCB SP 6-32 Amps,10KA, 'C' series 240V complete all as specified and directed. Make : Legrand/Seimens/GE
S & F Ceiling fan 5 Star Rated 1200 mm sweep heavy duty type complete with and suitable for operation on 230 Volts single phase 50 Hz AC supply and connectin up with and including two core PVC insulated, PVC sheathed copper conductor flexible cable 24/ 0.2 mm including fixing and making connection and fixed by completed all as specified and directed. Make: Havells/CG/ khaitan
M&L for sub-main wiring with 2 runs of 4.0 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC conduit not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 4.0 sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex / Plaza
Supply and lay PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100volts grade, cross-sectional area 25 sq. mm 4 core with suitable accessories laid in trench/ duct / along pole/wall etc including making connection complete all as directed. Note : 1. The cost of thimbles/lugs & cable gland etc is incl in quoted rate and no extra payment will be made for it. Make- Polycab/ Havells/ Finolex
Supply and fix Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, full threded screws and (Narayan) nylon rawl plugs etc. surfaced on walls / roofs complete all as directed.
Supply and fix in repair MCCB 100Amps, 4 pole, 415V, 16 KA with suitable copper wire connection along with lugs, spreader terminal of suitable size and making connections including taking down the existing unsrviceable MCCB from the panel complete all as directed. Make :Legrand cat No 4200 15 or equivalent cat No. in Seimens/GE/C&S
Supply and fix anti static covering (The term anti-static refers to a very specific electrical resistance range of between 10⁹ and 10 to the 11 and only) for flooring fullu up to 20-25cm height on all side of floor including door plinth complete all as directed. Make : BASF, CIPY, FOSROC, SIKA, PIDILITE
Supply, install, testing and commissioning wall mounted Split inverter AC, electric driven, 1.5 TR capacity units indoor/ outdoor, single phase, 240V, 50 Hz complete with cordless remote control unit, fitted with high quality rotary compressor and with in built air ioniser and plasma filter for better indoor air quality with 5 star rating including inbuilt of voltage stabiliser complete all as specified and as directed. Make: Voltas/Hitachi/Mitsubishi Notes:- (i) Rate of supporting brackets for outdoor units is deemed to be included in rate quoted. (ii) Supply and fixing copper tubings of appropriate dia for suction line and for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing though pipe and making good distrubed surface also deemed to be included in this item
Supply, install, testing and commissioning wall mounted Split inverter AC, electric driven, 2 TR capacity units indoor/ outdoor, single phase, 240V, 50 Hz complete with cordless remote control unit, fitted with high quality rotary compressor and with in built air ioniser and plasma filter for better indoor air quality with 5 star rating including inbuilt of voltage stabiliser complete all as specified and as directed. Make: Voltas/Hitachi/Mitsubishi Notes:- (i) Rate of supporting brackets for outdoor units is deemed to be included in rate quoted. (ii) Supply and fixing copper tubings of appropriate dia for suction line and for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing though pipe and making good distrubed surface also deemed to be included in this item
S & F in repair of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A complete all as specified and directed. Make :Legrand cat No 5078 10 or equivalent cat No. in Seimens/GE/C&S
S & F and installed of new 20 Zone fire alarm control panel with complete accessories all as specifed and dirceted
S & F and installed of new Electric Hooter with complete accessories all as specifed and dirceted
S & F and installed of new Combine smoke / Heat dectector with complete accessories all as specifed and dirceted
S & F of conventional manual pull station single action approval UL listed I (ANNUNCIATING DEVICES) with complete accessories all as specifed and dirceted Note:Need connect with back box Addressable mini monitor module eith back box.
M&L for maintenace free chemical earthing system for safe earthing electrode (SEE) designed with pipe technolgy with hot deep copper plated (80-100) micron MS pipe size of outer pipe 80mm and inner pipe 40mm, 3mtr long inside filled with crystaline conductive mixture (CCM) having non corrosive and conductive properties complete eith two bag of black fill compund mixed with soil all around the earth pipe for smooth charge dissipation complete with bricks wall earth pit of size 450mm x 450mm with RCC pit cover. (03 Nos for each earthing pit) Note :- (1) The specified values of earth resistance ie less than 1 Ohm shall be subjected to soil condition. in generalresistivity of soil of the above the area is 8 to 16 ohms mtr with above earthing resisitivity could be achieved upto 3 ohms. However by connecting in grid of three earthing 1 ohm could be achived. (2). Earth strip will be measured and paid seprately.
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire all as specified and directed.
Supply and lay PVC insulated, armoured heavy duty electric cable with Copper conductor, 1100volts grade, cross-sectional area 1.5 sq. mm 2 core with suitable accessories laid in trench/ duct / along pole/wall etc including making connection complete all as directed. Note : 1. The cost of thimbles/lugs & cable gland etc is incl in quoted rate and no extra payment will be made for it. Make- Polycab/ Havells/ Gloster
Rohit Enterprises
Sri Tirupati Enterprises
SRI CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .