Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 LAccepted-AOC 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L1 | Accepted-AOC BEING LOWEST AND REASONABLE | |
| 2 | L2₹13.5 L+₹8,474 (0.63%)Rejected-AOC | L2 | Rejected-AOC NOT BEING L1 | |
| 3 | L3₹22.8 L+₹9.3 L (69.2%)Rejected-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-AOC NOT BEING L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical NOT BEING ENLISTED IN APPROPRIATE CATEGORY |
Tender Value
₹24.2 L
EMD Value
₹48,320
Closing Date
25 Oct 2021, 6:00 pmClosed
GE EM RR HOSPITAL
GE EM RR HOSPITAL DELHI CANTT-10
CA No GE/H-23/2021-22 REPAIR/MAINT OF ALL TYPES OF FANS GEYSERS HOT FOOD TROLLIES AND OTHER CONNECTED ITEMS AT AHRR UNDER GE E/M RR HOSPITAL DELHI CANTT-10
2021_MES_478105_1
GE/H-23/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE EM RR HOSPITAL
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE EM RR HOSPITAL
₹48,320
3 Jan 2022
27 Sept 2021
27 Oct 2021
27 Sept 2021
25 Oct 2021
11 Oct 2021
Amount
Taking down unserviceable ceiling / exhaust / cabin / wall / air circulator / padestal fans of any type / make / capacity from various locations of AHRR complex by disconnecting the electrical connection and overhauling the same comprising of cleaning the fans to remove sticky dust with cloth or emery paper, oiling, greasing, including replacement of defective parts such as split pins, terminal block, rubber reel, PVC bush, body screws, MS stator shaft work, Machining of shaft & fan body for making housing etc, applying one coat of synthetic enemal paint match with existing surface (white/green/gray colour) after prepration of old surfaces, marks MES Nos & AGE E/M RRH using black colour on all types fans and refixing the same in position after repair and testing complete all as specified and directed by Engr-in-Charge. Note- 1. Testing of fans will be carried out in presence of JE E/M/ Engineer-in-Charge. 2. Any parts other than indicated in item shall be measured and paid seperately under repective items here-in-after as supply only, however labour charges for taking down and fixing of these parts (except item catered M&L ) are deemed to be included in quoted rates. 3. Contractor ensure to depute the electrician once a day for attending and taking out/down and refixing again duly repaired the any type of fan with in 08 hrs after receiving the complaint.
M&L for rewinding of ceiling fan mortar of 1200 to 1400mm dia sweep including cutting and removing the old defective/burnt winding wire, cleaning the core of the fan motor, rewinding the fan motor with and including super enameled copper winding wire of appropriate/same gauge using insulating materials, varnishing the core assembly, drying the winding for adequate period to remove the moisture content, strengthening the winding and re-assembling the core including testing to the speed and flow of the fans, complete all as specified and directed by Engr-in-Charge.
All as per srl item no 02 here-in-before but for Exhaust fan of 230 to 380 mm sweep size.
All as per srl item no 02 here-in-before but for Exhaust fan of 450 mm sweep size.
All as per srl item no 02 here-in-before but for Exhaust fan of 600 mm sweep size of 3 HP capacity .
All as per srl item no 02 here-in-before but for Wall fan / air circulator /pedestal fan of 400-450 mm sweep size.
All as per srl item no 02 here-in-before but for Wall fan / air circulator of 600 mm sweep size.
Supply and fixing in replacement of Blower fan dynamically balance suitable for 5 HP 415 V , 3 phase exhaust hood for 450 to 600 mm sweep complete all as specified and directed by Engr-in-Charge.
Supply only metallic bush suitable for ceiling / exhuast / air circulator / Padestal fan of any type / size / make, complete all as specified and directed by Engr-in-Charge.
Supply only ball bearing suitable for ceiling / exhuast / air circulator / Padestal fan of any type / size / make, complete all as specified and directed by Engr-in-Charge.
Supply only capacitor of 2.5 mfd, 440V, 50 Hz suitable for ceiling / exhaust / cabin / air-circulator / Padestal fan of any type / make / size, complete all as specified and directed by Engr-in-Charge.
All as per srl item no 11 here-in-before but of 3.15/4 mfd capacity.
All as per srl item no 11 here-in-before but of 6/8.0 mfd capacity.
Supply only metallic fan blades (Set of 3 or 4 blade)) of existing pattern & colour scheme including screws suitable for ceiling fan of any make / model / sweep size, complete all as directed.
All as per srl item no 14 here-in-before but for Exhaust fan of upto 300-380 mm sweep size.
All as per srl item no 14 here-in-before but for Exhaust of 450 mm sweep size.
All as per srl item no 14 here-in-before but for Pedestal fan 400 to 450mm sweep size.
All as per srl item no 14 here-in-before but for Pedestal fan of 600 mm sweep size.
All as per srl item no 14 here-in-before but for Wall fan/Air circulated fan 400 to 450 mm sweep size.
All as per srl item no 14 here-in-before but for Wall fan/Air circulated fan 600 mm sweep size.
Supply only PVC fan blade of existing pattern and colour scheme including screws suitable for exhaust/wall fan / cabin fan / Padestal fan of any type / make / sweep size, complete all as specified and directed by Engr-in-Charge.
Supply only PVC clamp holder for capacitor with screw of any type and size, complete all as specified and directed by Engr-in-Charge.
Supply only heavy gauge fan hanging clamp fabricated out of MS flat with rubber reel, nut, bolts, washer with split pins, complete all as specified and directed by Engr-in-Charge.
Supply only factory made ceiling fan down rod 0.3 m long, made out of heavy grade MS conduit of 19/20 mm outer dia, with hole at both ends for passing cable, cut at one end for fixing of fan, hole at other end for fixing fan clamp, duly painted with white synthetic enemel paint of 1st quality, complete all as specified and directed by Engr-in-Charge.
All as per srl item no 24 here-in-before but 0.6 m long complete all as specified and directed by Engr-in-Charge.
All as per srl item no 24 here-in-before but 0.9 m long complete all as specified and directed by Engr-in-Charge.
All as per srl item no 24 here-in-before but 1.2 m long complete all as specified and directed by Engr-in-Charge.
Supply only, in replacement, PVC insulated, PVC sheathed, multistranded copper conductor wire of 0.75 Sqmm size, three core, ISI marked, complete all as specified and directed by Engr-in-Charge.
Supply only in replacement, PVC insulated, PVC sheathed, multistranded copper conductor wire of 1.5 Sqmm size, three core, ISI marked, complete all as specified and directed by Engr-in-Charge.
M&L for rewinding of blower fan motor 5 HP capacity including cutting and removing the old defective/burnt winding wire, cleaning the core of the fan motor, rewinding the fan motor with and including super enameled copper winding wire of appropriate/same gauge using insulating materials, varnishing the core assembly, drying the winding for adequate period to remove the moisture content, strengthening the winding, replacement of bearing and re-assembling the core including testing to the speed and flow of the fans, complete all as specified and directed by Engr-in-Charge.
Taking down unserviceable Geysers of any capacaity/type/make from various locations by disconnecting the electrical connection and Overhauling the geysers for necessary repair work comprising opening, descaling, brushing and cleaning of storage tank and examining of water tightness of storage tank after cleaning and descaling, checking & connecting earth continuity of electric items, adjusting of pressure release valves, checking of dead weight, cleaning of vent hole, including replacements of all defective parts of the geysers after repair, applying one coat of synthetic enemal paint (white colour) after prepration of old surfaces, marks MES Nos & AGE E/M RRH using black colour and testing complete all as specified and directed by Engr-in-Charge. Note- 1. Testing of Geysers will be carried out in presence of JE E/M/ Engineer-in-Charge. 2. Any parts other than indicated in item shall be measured and paid seperately under repective items here-in-after as supply only, however labour charges for taking down and fixing of these parts(except parts catered as M&L or S&F) are deemed to be included in quoted rates. 3. Contractor to ensure to depute the electrician once a day for attending and taking out/down and refixing again duly repaired the geyser with in 08 hrs after receiving the complaint.
Material and labour for brazing / welding of inner steel tank at leaking spots including necessary pressure testing of geyser inner tank at 35 lb per sqinch for geyser of any type / make / capacity complete all as specified and directed by Engr-in-Charge.
Supply only heating element 2 KW capacity ISI Marked suitable for geyser of any type / Make and capacity complete all as specified and directed by Engr-in-Charge.
All as per srl item no 33 here-in-before but 1.5 KW capacity.
All as per srl item no 33 here-in-before but 3 KW capacity.
Supply only of thermostat ISI Marked suitable for geyser of any type and capacity including making necessary electric connection and testing the geyser complete all as specified and directed by Engr-in-Charge.
Supply only of inner shell of suitable size made of stainless steel, duly pressure tested for 25 Metre water head, suitable for geyser 10 litres capacity with and including all suitable fixing accessories complete all as specified and directed by Engr-in-Charge.
All as per Srl No items No 37 here-in-before but 25 ltrs capacity
All as per Srl No items No 37 here-in-before but 35 ltrs capacity
All as per Srl No items No 37 here-in-before but 50 ltrs capacity
Supply only of outer shell of suitable size made of steel sheet ISI Marked for geyser of any type/Make and 10 litres capacity complete with two coats of synthetic enamel paint over one coat of primer by spray gun with all suitable accessories, complete all as specified and directed by Engr-in-Charge.
All as per Srl No items No 41 here-in-before but 25 ltrs capacity
All as per Srl No items No 41 here-in-before but 35 ltrs capacity
All as per Srl No items No 41 here-in-before but 50 ltrs capacity
Supply only of copper connection pipe of 15mm bore heavy duty chromium plated 450 mm long , 15mm bore and C P brass adopter with rubber washer for hot water outlet connection, ISI Marked for geyser of any type / Make and capacity complete all as specified and directed by Engr-in-Charge.
Supply only of indicator lamp set of Red &Green colour, suitable for geyser of any type / Make and capacity ISI marked including making necessary electric connection complete all as specified and directed by Engr-in-Charge.
Supply only of new insulating material made of PUF / glass wool of superior quality of 16 Kg / Cum density in geyser of any Type/Make of 10 ltrs to 25 litres capacity complete all as specified and directed by Engr-in-Charge.
All as per srl item no 47 here-in-before but for 35 ltrs to 50 litres capacity.
Supply only appratus plate assembly 6 hole/9 hole complete with inlet / outlet, thermostat pipes with drain plug and screw including clamps for holding the elements, nuts, bolt etc, for geyser of any type/Make and 10 ltrs to 50 litres capacity complete all as specified and directed by Engr-in-Charge.
Supply only bottom cover plate (2 valves) with matching colour of geysers of any type and capacity complete all as specified and directed by Engr-in-Charge.
Supply only non return valve in position ISI marked made out of cast copper alloy, internally screwed on one end and externally screwed on other end suitable for iron pipe of size 15 mm, suitable for geysers of any type/Make and capacity complete all as specified and directed by Engr-in-Charge.
Supply only blow off type fusible plug brass nut with lead as fusible material complete all as specified and directed by Engr-in-Charge.
Supply only 15mm bore 600 mm long flexi connection braided pipe of best quality ISI marked suitable heavy duty for cold/hot water and complete connection with geyser including all accessories complete all as specified and directed by Engr-in-Charge.
S&F in repair GI fastner 10 mm dia x 100 mm long duly threaded with GI nut and washer etc for holding geyser (set of 04 Nos) including fixing arrangement by making necessary holes and using cement mortar(1:2) or PCC 1:2:4 and making good the disturbed surface as per existing complete all as specified and directed by Engr-in-Charge. (Note: 04 Nos fasteners shall be measured as one job)
All as per Srl No items No 54 here-in-before but 150mm long
Supply only PVC plug top 3 pin 25 amp suitable for 3 pin 25 amps socket complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCB protected modular AC/Geyser box complete with and including 6 pin socket, plug top, modular cover plate, mini MCB SP 25 Amp capacity and PVC gang box etc, complete all as specified and directed by by Engineer-in charge.
S&F in repairs mini MCB C Curve type, 10 kA, 25 Amp, Single Pole with over load and short circuit protection complete all as specified and directed by Engr-in-Charge.
Supply only vaccum release valve complete all as specified and directed by Engr-in-Charge.
Supply only Pressure release valve complete all as specified and directed by Engr-in-Charge.
M & Lin repair of hot food trolley of any shape and size including broken wheel base, pulling handle, hinges, doors, door supports, chains, leakages of water etc using stainless steel sheet (Gd-304) of min 2.0 mm thickness and SS (Gd-304) brackets, angles, hollow tubes, flats etc of any shape of size with and including SS hinges, screws / fasteners, complete electrical work, all kind of machine works i.e. cutting, SS welding, bending, moulding, grinding, polishing, buffing etc to get the required strength, shape and size, fixed to any position and makes functional complete all as specified and directed by Engr-in-Charge. Note : 1. The cost of all kind of SS material i.e. sheet, angle, tube flat, all kind of fittings & fixtures i.e. hinges, screws / fasteners, handles etc (except the parts catered here-in-after as supply only) are deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. 2. The cost of transportation (to and fro) and other necessary equipment shall be arranged/brought by contractor and no extra cost shall be paid to the contractor in this effect. 3. The defective spare parts as catered supply only shall be paid and measured seperately in relevant items here-in after. 4. The trollies will be checked once in a month and records mantained properly.
Supply only 25 Amps socket multipurpose complete all as specified and directed by Engr-in-Charge.
Supply only PVC insulated, PVC sheathed, multistranded copper conductor wire of 2.5 Sqmm size, three core, ISI marked, complete all as specified and directed by Engr-in-Charge.
Supply only 150 mm dia caster wheel with swivel type heavy duty supporting base plate bracket complete with nut and bolts etc suitable for hot food trolley, complete all as specified and directed by Engr-in-Charge.
Supply only 150 mm dia caster wheel with fixed type heavy duty supporting base plate bracket complete with nut and bolts etc suitable for hot food trolley, complete all as specified and directed by Engr-in-Charge.
Supply only dry type U shaped heating element 2 KW of length minimum 2 mtr suitable for hot food trolley, complete all as specified and directed by Engr-in-Charge.
Supply only capacitor of 1.5/2.0 mfd, 440V, 50 Hz suitable for ceiling / exhaust / cabin / air-circulator / Padestal fan of any type / make / size, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair metal body louvers heavy duty including fixing accesoories of size 230 mm sweep to 380 mm sweep complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair metal body louvers heavy duty including fixing accesoories of size 450 mm sweep complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair metal body louvers heavy duty including fixing accesoories of size of 600 mm sweepcomplete all as specified and directed by Engr-in-Charge.
Supply only 25 Amps switch, one way, single pole complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of fresh air fan PVC body single phase, 240 volts, upto 1200 RPM of 300mm sweep, copper winding complete all as specified and directed by Engr-in-Charge.
All as per sl item No 75 But 250 mm Sweep.
Supply only fresh air fan motor single phase, 240 volts, upto 900 RPM suitable for 250mm to 300mm complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engr-in-Charge.
All as per item Sl No 78 but of size 1400mm with Min Air delivery 245 CFM and service value complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, BEE 5 Star rated with Squirrel cage induction motor complete all as specified and directed by Engr-in-Charge.
All as per item Sl No 80 but of size 1400mm
Suplply only PCB (Printed Circuit Board) for existing digital type geyser of capacity 25 ltrs including control remote and digital display complete all as specified and directed by Engr-in-Charge.
M&L for maintenance / servicing of Automatic/ sensor silliding door including replacement of defective /spare parts/items such as such as side plate, timming belt, hanger roller, cable tray Plates motor, controller belt connector Belt adjust Pully etc excluding Door Glass, when required by automatic door technician / Engineers must be qualidfied to work on automatic door to BS 7036 and make it in proper functning complete all as specified and directed by Engr-in-Charge. Note :-1. To provide the evidence that parameter are adhered too and safety devices are in place2. if the faultsfound which affects safe operation of the door, then the door operating equipement must be switched off and the door made safe.
Supply and fix in repair SMPS for assembly for automatic sliding door ES 200 Easy, CS 85 complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair MDU controller assembly assembly for automatic sliding door ES 200 Easy complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair motor assembly for automatic sliding door (CS 85) complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair return pulley assembly CS 85 for automatic sliding door (CS 85) complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair of Air Circulator fan 230Volts single phase oscillating 4500mm sweep suitable for wall mounting complete all as specified and directed by Engr-in-Charge.
All as per sl item no 88 but of sweep 600mm
Supply and fix in repair electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair stepped type electronic fan regulator flush type on the exiting phenoic laminated complete all as specified and directed by Engr-in-Charge..
CHAUHAN ENTERPRISES
RUCHIKA ENGG.WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .