| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹37.0 L+₹2.6 L (7.63%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹37.7 L+₹3.4 L (9.84%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹37.7 L+₹3.4 L (9.84%)Rejected-Finance 307 SADAR BAZAR LUCKNOW UP 226002 | LUCKNOW | UTTAR PRADESH | 226002 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹38.3 L+₹3.9 L (11.4%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L5 | Rejected-Finance Being L5 |
Tender Value
₹40.5 L
EMD Value
₹81,000
Closing Date
19 Jul 2023, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (UP) PIN 226002
PROVN OF LED SECURITY LIGHTS WITH POLE NEAR SECURITY FENCE (3000 MTR) AND SECURITY POSTS WORK (12 NOS) OF 11 GRRC AND SPL REPAIR/REPLACEMENT OF SPLIT/WINDOW TYPE AC AGAINST BER AT BASE HOSP UNDER GE E/M LUCKNOW
2023_MES_604312_2
GE/EM/LKO/EXT(ELECT)/T-17 OF 2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹81,000
Yes
11 Sept 2023
8 Jul 2023
21 Jul 2023
8 Jul 2023
19 Jul 2023
14 Jul 2023
Amount
Supply and installed steel tubular swaged pole type 410 SP - 31 (9 mtr long) complete with MS base plate of size 300x300x6mm thick at bottom, welded at the centre with through hole of 14mm dia at a height of 300mm above the coping finial cap and painted with two coats of aluminium paint over a coat of red oxide primer with writing number including excavation upto required depth and PCC type C-2 1:3:6 (using 40mm graded) at bottom and PCC type B-1 1:2:4 (20mm graded) for mass filling and pole coping (60x60x30cm) and rendering of coping with 10mm thick in1:6 cement mortar complete all as specified and directed.
Supply & laying LT cable U/G XLPE insulated armoured heavy duty electric cable 1100 volts grade Aluminium conductor 16 Sqmm 4 core. Laid in trenches/fixed on poles, walls or under floors etc complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply & laying LT cable U/G XLPE insulated armoured heavy duty electric cable 1100 volts grade Aluminium conductor 25 Sqmm 4 core. Laid in trenches/fixed on poles, walls or under floors etc complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply & laying LT cable U/G XLPE insulated armoured heavy duty electric cable 1100 volts grade Aluminium conductor 35 Sqmm 3.5core. Laid in trenches/fixed on poles, walls or under floors etc complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply & laying LT cable U/G XLPE insulated armoured heavy duty electric cable 1100 volts grade Aluminium conductor 50 Sqmm 3.5 core. Laid in trenches/fixed on poles, walls or under floors etc complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately .
Supply & laying LT cable U/G XLPE insulated armoured heavy duty electric cable 1100 volts grade Aluminium conductor 16 sqmm 2core. Laid in trenches/fixed on poles, walls or under floors etc complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and fixing / passing through pipe from junction box to street light connection,1100 volts grade heavy duty cable with PVC solid insulated aluminium conductor served with an inner sheathing PVC tape and overall PVC sheathed 6 sq mm 2 core nominal cross section, complete all as specified and directed.
Supply & Fixing security light Bracket made out of GI light grade pipe of 40 mm bore 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp 50mm x 500 and 04 sets of nuts,bolts and washers painting with two coats of synthetic enamel paint over a red oxide primer complete all as specified and directed.
Supply and fixing Junction box of size 200mm x 140mm x 95mm outdoor type, weather proof, factory made out of PVC sheet 1.8mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and out going cable / wire complete comprising with the followings :- (a) Bus bar with four aluminium strips, 63 Amps cap. insulated with insulators, incl colour coding , including PVC cable of suitable size from bus bar to MCB (b) MCB SP 5 to 30 Amps, - 01 No (c) clamp made out of 25mm x 3mm flat iron duly welded with nuts & bolts complete all as specified and directed.
Supply and fixing Junction box of size 200mm x 140mm x 95mm outdoor type, weather proof, factory made out of PVC sheet 1.8mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and out going cable / wire complete comprising with the followings :- (a) Bus bar with two aluminium strips, 63 Amps cap. insulated with insulators, incl colour coding , including PVC cable of suitable size from bus bar to MCB (b) MCB SP 5 to 30 Amps, - 01 No (c) clamp made out of 25mm x 3mm flat iron duly welded with nuts & bolts complete all as specified and directed.
Supply and fixing of 90 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing with screws , street light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110>_ lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted Driver THD, open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD , and provided with company LOGO ingraved on housing of the Street light complete all as specified and directed. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement
Supply and fixing of 120 W LED flood light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing with screws , flood light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110>_ lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted IP 66 electronic LED potted driver with open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD and provided with company LOGO ingraved on housing of the flood light complete all as specified and directed. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement
Material & Labour for earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6.0 mm thick buried directly in ground surrounded by charcoal or coke and slat (earth pit not less than 2.25 meter deep below normal ground level) with top edge plate at a depth of not less than 1.50 meter below gorund level connected to and including galvanised earth lead wire 4mm dia fixed by means of nuts, bolts check nuts & washers protected by GI pipe 15mm bore (ligh grade) and connected to main switch board or main control board all as specified and directed in electric plate No 5 of SSR Part -I including testing on completion. (Note : (a) The units rate includes the cost of excavation & earth work in any type of soil charcoal & salt in altemate layers, 20mm GI Pipe (light grade) for watering 15mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made.)
M&L for earthing complet with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m in deep below ground level with top edge of the plote not less than 1.5m deep below normal ground level connected to and incl 32x6mm dia galvanised strip as earth strip by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2020) part-I incl 50mm bore GI pipe for protection upto 5 mtr length and PCC 1:2:4 type B-1 as in pit excavation and earth work in any type of soil charcoal common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron fixing and wiremesh and testing on completion all as specified and directed.
Excavation in trenches n. exc 1.5 m wide & n. exc 1.5 m in depth for stay assembly / laying under ground cables / erection of pole and getting out in hard/dense soil, complete all as specified.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified.
Removal of excavated surplus material (Soil) to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5mtr above the starting point complete all as specified.
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
M & L for laying well burnt brick work with fly ash bricks as per IS 12894 -2002 in trenches perpendicular to axis of the cable complete all as specified and directed.
Boring/drilling (Horizontly) manually/ mechanically under existing road upto 100 CM in depth) suitable for passing GI Tubing 40 to 100 mm bore complete all as specified and directed.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
Supply, installing, testing and commissioning in replacement factory made , tested , CPRI approved powder coated Timer panel board (Dimention of Cubical/enclosure not less than 600mmx450mmx450mm) ,cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The timer panel shall be dust and vermin proof IP-54 class protection and outer shell made of of 3.15 mm CRCA MS sheet, inner shell made of 2.0 mm thick CRCA MS sheet , 40x40x6mm thick MS angle iron frame work, the cubical have bottom support of angle iron 50x50x6mm duly coated with zink metal coating,front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following :- Contd/----
Item No 22.00 contd/--- (a) Incoming :- (i) MCCB 4 pole , 63 Amps,50 Hz,415 Volts, 16 KA, with thermal magnetic release - 01 Nos Item No 22.00 contd/--- (ii) 3 pole power contractor AC 3 rating 40 Amp, 240 Volt AC -01 Nos (iii) Astronomical Digital Timer Switch 240 V AC -01 Nos (iv) Digital VAF+PF meter with RS 485 Cl-1 -01No (v) CTs ratio 200/5 A ,class 1, ISI marked -01 sets of three (vi) Indicating lamp- 01 set of three (vii) Four Pole , Aluminium bus bar 150 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
Item No 22.00 contd/--- (b) Outgoing (i) MCCB 4 pole , 40 Amps,50 Hz,415 Volts, 16 KA thermal magnetic release - 02 Nos Note - Plateform of panel fixed with PCC 1:4:8 type D-2 with 40mm graded crused stone ,15 cm thick in foundation,brick work in CM 1:6 with sub class B old size bricks ,rendring 15 mm thick in CM 1:6 on exposed surface and 100 mm thick PCC padding 1:3:6,type C-1 using 20mm graded crushed stone aggregate on Top and grouting bolts etc for panel.The plate form shall be such that it is of a height 45 cm above the nearest road level. All out going feeder shall be connected by cable through suitable size gland plate/glands. All MCCB with adjustable protection for over load and short circuit protection and confirming to IEC60947-II/IS 13947 -II (Latest Version). The MCCBs shall have spreader links and barriers as standard feature of manufacture.
Supply & Fix CI cable route indicator 100mm dia 5mm thick duly engraved with "LT 1100Volts" having CI rod 10mm dia 50 to 70 cm long. Duly welded to round plate complete with PCC 1:4:8 complete all as specified and directed .
S&F GI pipe light graded 80mm dia as per protection to cable along the pole / across the road crossing /through culvert /passing through ceilling /wall with necessary/ clamps 02 nos (flat iron 50x6mm) with nuts and bolts complete all as specified and directed .
Supply, installing, commissioing and testing , split Air Conditioner of capacity 1.5 TR (Hot & Cold) 3 star with inbuilt air ioniser and plasma filter, rotary compressor,auto clean function, indoor sound level 32 db, front panel display, wireless LCD remote, precoated aluminium fins, , auto fan speed, electric driven , suitable for working on 230 volts, single phase, 50 Hz supply complete including remote operation complete all as specified and directed. The rate is included for following item-: (a) Fixing the cooling unit with grouting nuts, cutting groove to wall for gas pipe & water drainage pipe (b) S&F cutting, bent to shape copper pipe of appropriate size from outdoor unit to indoor unit by cutting holes to wall including brazing the copper pipe fixing union including making good disturbed surfaces as existing. (c) S&F PVC pipe 20 mm dia transparent flexible heavy duty for water drainage pipe of upto 06 RM at site. (d) Insulation of both the copper pipes with insulating material and covering the complete pipe with PVC casing & caping of size 75 x 75 mm/reqd size for mechanical protection of copper pipe complete. Contd/---
Item No 25.00 contd/--- (e) Charging of correct qty of refrigerant gas after necessary brazing/fixing of both the outdoor/indoor unit and testing complete on load to obtain 18 degree celsius temperature at specified amps. (f) All other connected civil work like hole cutting & other misc work reqd for installation of split AC for proper functioning as directed by EIC. (g) outdoor AC portion to be fixed on wall mounted stand as suitable for fixing of AC.
S&F plug and socket DBs with Single pole MCB rated 32 Amps capacity with socket plug top 2 pin and earth plug complete all as specified of standered make including making good disturbed surface of wall etc complete all as specified and directed.
S&F sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20 mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
Yaduvanshi Traders
Ajanta Associates
M/s Vatsh Raj and co
santosh electronics
Diamond Electric Co.
Ajanta Motor Store
M/s A.K Construction
Puma Power
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .