| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.7 L+₹1.2 L (21.6%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹7.6 L+₹2.1 L (39.0%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹7.7 L+₹2.2 L (39.7%)Rejected-Finance SURVEY NO 93 392 PACHMARHI NEAR MILITARY HOSPITAL PAHMARHI HOSHANGABAD M P 461 881 | PACHMARHI | HOSHANGABAD | MADHYA PRADESH | 461881 | L4 | Rejected-Finance L4 | |
| 5 | L5₹7.7 L+₹2.2 L (39.9%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
13 Jun 2024, 6:00 pmClosed
CWE JAIPUR
Military Engineer Services, HQ Commander Works Engineer, Kalyan Marg, Banipark, Jaipur-06
REPAIR AND MAINT OF AC REFRIGERATION DEEP FREEZER WATER COOLER AND CONNECTED ITEMS AT NIWARU MIL STN UNDER AGE (I) NIWARU
2024_MES_654250_1
CWE/JPR(N)/82357/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
NIWARU JAIPUR
As per NIT
8 documents required · 8 mandatory
₹500
AGE(I) NIWARU
₹20,000
Yes
13 Jul 2024
16 May 2024
15 Jun 2024
16 May 2024
13 Jun 2024
31 May 2024
16 May 2024 - 30 May 2024
Amount
Dismantling and taking out window type air conditioner of capacity 1.5/2 Ton, transporting to the nearest workshop for repairing including dismantling cleaning,replacement of necessary new spares/items, testing on load and back after repairs, re-installing in its original position, making all required connections and commissioning complete all as specified and directed. Note :- Spares parts will be measured and paid separately.
Dismantling and taking out split type air conditioner of capacity 1.5/2 Ton, transporting to the nearest workshop for repairing including dismantling cleaning,replacement of necessary new spares/items, testing on load and back after repairs, re-installing in its original position, making all required connections and commissioning complete all as specified and directed by Engineer-in-charge. Note :- Spares parts will be measured and paid separately.
Dismantling and taking out Refrigerator of any type capacity or make, transporting to the nearest workshop for repairing including dismantling cleaning,replacement of necessary new spares/items, testing on load and back after repairs, re-installing in its original position, making all required connections and commissioning complete all as specified and directed by Engineer-in-charge Note :- Spares parts will be measured and paid separately.
Disconnecting all electrical connections and taking down Deep freezer of type any make, transporting to the nearest workshop for repairing including dismantling cleaning,replacement of necessary new spares/items, testing on load and back after repairs, re-installing in its original position, making all required connections and commissioning complete all as specified and directed by Engineer-in-charge. Note :- Spares parts will be measured and paid separately.
Supply only the following spares/items of window/split type air conditioner of capacity 1.5/2 Ton. (Note: Make of spares shall be of the same original manufacturer as per existing) :-
Overload protection relay
Thermostat
Starting capacitor AC 230 V, 40-60 MFD
Copper capillary Tube of any size
Front grill suitable for any type or capacity for window type AC
(Hermitically sealed compressor unit comprising of the compressor coupled with inbuilt AC single phase 230V motor and other standard compressor accessories complete for window type / split type air conditioner of 1.5 Ton capacity. (Make: Usha / Voltas / Godrej).
Hermitically sealed compressor unit comprising of the compressor coupled with inbuilt AC single phase 230V motor and other standard compressor accessories complete for split type air conditioner of 2 Ton capacity. (Make: Usha / Voltas / Godrej).
Blower motor suitable for any make/model/capacity with single shaft/double shaft
Plastic fan blade suitable for any make/model/ capacity for split type AC
Compressor mounting rubber set
Electronic circuit complete suitable for 1.5/2 Ton A/C (PCB)
Cooling coil complete set
Condenser complete set
Supply only the following spares/items of refrigerator of 180/215/320 Ltr of capacity (Note: Make of spares shall be of the same original manufacturer as per existing) :-
Box type relay
Thermostat
Drier 1/4 size
Cooling coil
Condenser
(Copper capillary Tube size of 1/4 inch outer dia
Copper tubing of size 5/16 inch dia
Magnetic door gasket
Ice tray
Vegetable tray
Aluminium grill rack
Pigmy lamp 15W
Fan Motor
Hermitically sealed compressor unit comprising of the compressor coupled with inbuilt AC single phase 230V motor and other standard compressor accessories complete for Refregerator 180/ 215 ltrs capacity. (Make:Shriram / Kirloskar / Usha / Voltas / Godrej).
Hermitically sealed compressor unit comprising of the compressor coupled with inbuilt AC single phase 230V motor and other standard compressor accessories complete for Refregerator 258/320 ltrs capacity. ( Make:Shriram/Kirloskar/Usha/Voltas/Godrej).
Compressor mounting rubber set
Supply only the following spares/items of Deefrezer 200/ 320 Capacity.
Box type relay
Thermostat
Drier
Cooling coil
Condenser
Copper capillary Tube size of 1/4 inch outer dia
Copper tubing of size 5/16 inch dia
Copper tubing of size 3/8 inch dia
Magnetic top door gasket
Hermitically sealed compressor unit comprising of the compressor coupled with inbuilt AC single phase 230V motor and other standard compressor accessories complete for deep freezer 200/320 ltrs capacity. ( Make:Shriram/Kirloskar/Usha/Voltas/Godrej).
Compressor grouting rubber set
M&L for flushing out refrigerant pipes, vacuuming the hermitically sealed compressor, charging of refrigerant (Floran-22) in adequate quantity, connecting suction and discharge lines and conducting leakage test for windows/split type air conditioner of 1.5/2 Ton capacity complete all as specified and directed by Engineer-in-charge.
M&L for flushing out refrigerant pipes, vacuuming the hermitically sealed compressor, charging of refrigerant (Gas 134A) in adequate quantity, connecting suction and discharge lines and conducting leakage test for any type/make/capacity of refrigerator complete all as specified and directed by Engineer-in-charge.
M&L for flushing out refrigerant pipes, vacuuming the hermitically sealed compressor, charging of refrigerant (Floran-600A) in adequate quantity, connecting suction and discharge lines and conducting leakage test for any type/capacity of Deep freezercomplete all as specified and directed by Engineer-in-charge
M&L for Shifting of window/split type A/C, any capacity, any make and re-installing in its original position, making all required connections and commissioning complete all as specified and directed by Engineer-in-charge.
M&L for Shifting of Split type A/C , any type / any capacity, any make with necessary addition / alteration to window / wall complete all upto entire satisfaction complete all as specified and directed by Engineer-in-charge
Taking out the unserviceable blower motor from AC of any capacity and transporting to workshop for repair, dismantling & removing the burnt winding & rewinding it with same gauge, super enameled copper winding wire, varnishing, heating including replacement of minor hardwares and refixing & testing complete all as specified and directed by Engineer-in-charge
M&L for dismantling of existing unserviceable voltage stablizer for repairs including replacement of relays, electronic voltage sensor circut and meter, micro switch, indicating light, RC filters and other connected items for making functional and rewinding of unserviceable transformer with super enameled copper wire of appropriate size, varnishing assembling and testing complete of capacity 1 KVA to 5 KVA upto satisfactory function of any capacity complete all as specified and directed by Engineer-in-charge
S&F in repair plug top 15A, 240 volts, complete all as specified and directed by Engineer-in-charge. (Make: ISI marked product of Anchor/Havells/Legrand)
S&F in repair plug top 5A, 240 volts.complete all as specified and directed by Engineer-in-charge. (Make: ISI marked product of Anchor/Havells/Legrand)
S&F in repair sheet metal enclosure with metal clad socket & plug top and MCB single pole neutral 32 Amps complete all as specified and directed by Engineer-in-charge. (Make: Havells / Indo Asian / HPL)
Dismantling/taking down of water cooler (40/80) Ltr for repair such as fan motor,compressor and other minor rep & fixing works as in item no. 18.01 to 18.06 from any place any capacity, transported to workshop & back after repair and testing complete all as specified and directed by Engineer-in-charge. (i) Spare Parts required for replacement shall be measured separately under respective supply only items given here-in-after under respective items. (ii) Gas will be measured and paid separately.
Supply only Compressor ( Sealed unit ) suitable for 40/80 Ltr. Water Cooler,complete all as specified and directed by Engineer-in-charge.
Supply only Fan Motor 1/10 H.P Single phase,230V for water cooler,complete all as specified and directed by Engineer-in-charge.
Supply only Thermostate for water cooler ISI marked,complete all as specified and directed by Engineer-in-charge.
Supply only Starting capacitor 60 to 80 MFD 230 volts, 50 Hz. complete all as specified and directed by Engineer-in-charge.
Supply only over load relay suitable for Water cooler 40/80 ltr, complete all as specified and directed by Engineer-in-charge.
Supply only Fan Motor blade as per sample complete all as specified and directed by Engineer-in-charge.
M/S Sheeba Enterprises
Gaurav & company
Dev Enterprises
Shree Karni Electrovision
M/S TRADE LINKERS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .