Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.5 LAccepted-AOC | ₹42.5 L Quoted ₹43.5 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹44.0 L+₹45,350 (1.04%)Rejected-Finance 203 NIVAAN LAXMI SOCIETY PLOT NO 169 SECTOR 19 KHARGAHAR NAVI MUMBAI 410210 | RAIGAD | MAHARASHTRA | 410210 | ₹44.0 L+₹45,350 (1.04%) | L2 | Rejected-Finance NOT ADMITTED BEING L2 |
| 3 | L3₹44.0 L+₹53,330 (1.23%)Rejected-Finance | ₹44.0 L+₹53,330 (1.23%) | L3 | Rejected-Finance NOT ADMITTED BEING L3 |
| 4 | L4₹45.3 L+₹1.8 L (4.05%)Rejected-Finance | ₹45.3 L+₹1.8 L (4.05%) | L4 | Rejected-Finance NOT ADMITTED BEING L4 |
| 5 | L5₹46.2 L+₹2.7 L (6.25%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹46.2 L+₹2.7 L (6.25%) | L5 | Rejected-Finance NOT ADMITTED BEING L5 |
| Sl No | Description | Qty | Unit | venus enterprises L7 | Shri Krishna Trading Corporation L3 | Nexus Infratech L1 | M.K Enterprises L5 | VARDHAMAN CONSTRUCTION COMPANY L8 | K N CONSTRUCTION L4 | BALAJI TRADERS L2 | Om Sai Enterprises L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Notes : - (i) The is at Serial No 6 of TPP 2025-26 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department. | |||||||||||
| 2.00 | Taking down carefully copper /aluminium point wiring (light, fan socket or power) through stove enamelled steel conduit/pvc conduits including complete fittings such as switches, ceiling roses, pendants, regulators, sockets,, switch sockets, electrical fittings etc removing and making good disturbed surfaces of walls/ceiling etc, complete all as specified and directed. | 798 | Point | 120 ₹95,760 | 140 ₹1,11,720 | 45 ₹35,910 | 29 ₹23,142 Lowest | 120 ₹95,760 | 100 ₹79,800 | 130 ₹1,03,740 | 127 ₹1,01,346 |
| 3.00M&L for Point wiring with 1.5 Sqmm single core, multi stranded copper conductor, 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable in concealed PVC conduit, ISI marked including all accessories as approved with & including PVC 1.5 mm multi stranded insulated unsheathed FRLSH copper wire, ISI marked of green colour for continous earth, including sunken box made out of suitable thickness and not less than 60 mm in depth GI/MS/ pressed steel terminal box duly concealed in wall, duly painted including laminated hylum/maonite sheet cover thickness 3mm for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer including cutting chases and making good disturbed surfaces as per existing for the following complete all as specified and directed :- Note : (i) Casing / capping on ceiling deem to be included in point wiring. (ii) Wiring to be done as per approved colour code. | |||||||||||
| 3.01 | One light /fan/ call bell point controlled by one switch | 50 | Point | 940 ₹47,000 | 950 ₹47,500 | 890 ₹44,500 Lowest | 969 ₹48,450 | 980 ₹49,000 | 950 ₹47,500 | 950 ₹47,500 | 980 ₹49,000 |
| 3.02 | One 5 pin socket outlet 5 Amps on independent board | 30 | Point | 1,045 ₹31,350 | 1,050 ₹31,500 | 955 ₹28,650 Lowest | 969 ₹29,070 | 1,035 ₹31,050 | 1,050 ₹31,500 | 1,050 ₹31,500 | 1,035 ₹31,050 |
| 3.03 | One 5 pin socket outlet 5 Amps on same board | 20 | Point | 235 ₹4,700 | 250 ₹5,000 | 125 ₹2,500 Lowest | 169 ₹3,380 | 245 ₹4,900 | 250 ₹5,000 | 250 ₹5,000 | 245 ₹4,900 |
| 3.04 | One light point controlled by 2 way switch SP, 5 Amp, 240 Volts | 10 | Point | 910 ₹9,100 | 850 ₹8,500 Lowest | 940 ₹9,400 | 1,109 ₹11,090 | 900 ₹9,000 | 850 ₹8,500 Lowest | 850 ₹8,500 Lowest | 900 ₹9,000 |
| 4.00 | All as per BOQ Serial item no 3.00 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLSH PVC insulated sheathed cable with FRLSH PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board complete all as specified and directed. | 10 | Point | 1,035 ₹10,350 | 950 ₹9,500 Lowest | 1,290 ₹12,900 | 999 ₹9,990 | 1,030 ₹10,300 | 950 ₹9,500 Lowest | 950 ₹9,500 Lowest | 1,030 ₹10,300 |
| 5.00 | M&L Point wiring with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked, PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in casing caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by EIC, with & including PVC 1.5 mm multi stranded insulated unsheathed FRLSH copper wire, ISI marked of green colour for continous earth, including sunken box made out of suitable thickness and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted including 3mm hylum /masonite sheet cover for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer for One light /fan/ call bell point controlled by one switch complete all as specified and directed.
Note : Wiring to be done as per arroved colour code. | 150 | Point | 810 ₹1,21,500 | 750 ₹1,12,500 | 680 ₹1,02,000 Lowest | 739 ₹1,10,850 | 800 ₹1,20,000 | 750 ₹1,12,500 | 750 ₹1,12,500 | 800 ₹1,20,000 |
| 6.00 | All as per BOQ Serial item no 5.00 above but One light point controlled by 2 way switch, SP, 5 Amp, 240 Volts | 10 | Point | 960 ₹9,600 | 950 ₹9,500 | 750 ₹7,500 Lowest | 939 ₹9,390 | 990 ₹9,900 | 950 ₹9,500 | 950 ₹9,500 | 990 ₹9,900 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
26 Jun 2025, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REPAIR REPLACEMENT OF POINT WIRING SUB MAIN WIRING LIGHT FITTINGS SWITCHSOCKETS AND DISTRIBUTION BOARDS AND MAINT OF METER PANELS MAIN LT PANELS LT XLPE CABLE MCCB MCB AND ALLIED WORKS ETC INSIDE LT PANEL ROOMS IN COMMON AREA NOFRA EM AT NS KARANJA
2025_MES_712613_1
8130/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE NW KARANJA
D and above b i
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹98,000
Yes
13 Sept 2025
5 Jun 2025
28 Jun 2025
5 Jun 2025
26 Jun 2025
19 Jun 2025
Amount
Notes : - (i) The is at Serial No 6 of TPP 2025-26 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department.
Taking down carefully copper /aluminium point wiring (light, fan socket or power) through stove enamelled steel conduit/pvc conduits including complete fittings such as switches, ceiling roses, pendants, regulators, sockets,, switch sockets, electrical fittings etc removing and making good disturbed surfaces of walls/ceiling etc, complete all as specified and directed.
M&L for Point wiring with 1.5 Sqmm single core, multi stranded copper conductor, 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable in concealed PVC conduit, ISI marked including all accessories as approved with & including PVC 1.5 mm multi stranded insulated unsheathed FRLSH copper wire, ISI marked of green colour for continous earth, including sunken box made out of suitable thickness and not less than 60 mm in depth GI/MS/ pressed steel terminal box duly concealed in wall, duly painted including laminated hylum/maonite sheet cover thickness 3mm for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer including cutting chases and making good disturbed surfaces as per existing for the following complete all as specified and directed :- Note : (i) Casing / capping on ceiling deem to be included in point wiring. (ii) Wiring to be done as per approved colour code.
One light /fan/ call bell point controlled by one switch
One 5 pin socket outlet 5 Amps on independent board
One 5 pin socket outlet 5 Amps on same board
One light point controlled by 2 way switch SP, 5 Amp, 240 Volts
All as per BOQ Serial item no 3.00 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLSH PVC insulated sheathed cable with FRLSH PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board complete all as specified and directed.
M&L Point wiring with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked, PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in casing caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by EIC, with & including PVC 1.5 mm multi stranded insulated unsheathed FRLSH copper wire, ISI marked of green colour for continous earth, including sunken box made out of suitable thickness and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted including 3mm hylum /masonite sheet cover for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer for One light /fan/ call bell point controlled by one switch complete all as specified and directed. Note : Wiring to be done as per arroved colour code.
All as per BOQ Serial item no 5.00 above but One light point controlled by 2 way switch, SP, 5 Amp, 240 Volts
All as per BOQ Serial item no 5.00 above but one 5 amp socket point on same board
All as per BOQ Serial item no 5.00 above but one 5 amp multi socket indepenedent
All as per BOQ Serial item no 5.00 above but using 2.5 sqmm (nominal area) multistranded FRLSH PVC copper conductor cable/wire with & including 2.5 sqmm size PVC insulated unsheathed copper conductor cable for earth continuity (green colour) for one 5 pin socket outlet 5 / 15 Amp multi purpose independent point controlled by 15 Amp switch, SP one way, 240 Volts & Socket, complete all as specified and directed.
All as per BOQ Serial item no 5.00 above but using 4 sqmm (nominal area) FRLSH PVC multistranded copper conductor cable/wire with & including 2.5 sqmm size PVC insulated unsheathed copper conductor cable for earth continuity (green colour) for one 5/15 Amp socket point controlled by 15 Amp switch, SP one way 240 Volts & Socket, complete all as specified and directed.
M&L for Point wiring for One light /call bell point controlled by one switch with PVC insulated unsheathed electric cable 1100 volts grade, single core, FRLSH cable having multistranded copper conductor of 1.5 Sqmm nominal cross sectional area, ISI marked, drawn in existing concealed conduit with & including 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor FRLSH cable, ISI marked as continuous earth conductor connected to earth dolly by providing suitable lugs with & including 3.0 mm laminated hylum sheet /masonite sheet cover cover of suitable sizes to be fixed/ mounted on existing MS/ GI sunkun boxes for mounting of fittings like switches, sockets, fan regulators etc fixed with galvanised screw and cup washer complete all as specified and directed. Note : Wiring to be done as per arroved colour code.
All as per BOQ Serial item no 11.00 above but for One fan/exhaust fan point controlled by one switch
All as per BOQ Serial item no 11.00 above but for One 5 pin socket outlet 5 Amps on same board
All as per BOQ Serial item no 11.00 above but for One 5 pin socket outlet 5 Amps on independent board
All as per BOQ Serial item no 11.00 above but for One light point controlled by 2 way switch SP, 5 Amp, 240 Volts
All as per BOQ Serial item no 11.00 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLSH PVC insulated sheathed cable with & including FRLSH PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for one 5 pin socket outlet 5 / 15 Amp multi purpose independent point controlled by 15 Amp switch, SP one way, 240 Volts & Socket, complete all as specified and directed.
S&F switch piano type flush button type single pole one way 5 Amps 240V front operated complete all as specified and directed.
S&F Switch socket combination 2 in 1 3 pin, 5 A and 15Amp flush type universal complete all as specified and directed.
S&F socket 3 pin 5 A flush type complete all as specified and directed.
S&F Bell buzzer 240v 50hz complete all as specified and directed.
S&F Bell push 240v 50 hz complete all as specified and directed.
S&F ceiling rose PVC/polycarbonate, isolated body surface Bakelite 65mm dia three terminals complete all as specified and directed.
S&F in repairs switch piano flush button single pole, one way, 6 Amp complete all as specified and directed.
S&F in repairs Switch socket outlet 2 in 1, 3 pin, 6 Amp flush type complete all as specified and directed.
S&F in repairs Socket outlet 2 in 1, 3 pin, 6 Amp flush type complete all as specified and directed.
S&F in repairs Switch bell push flush type 5 Amp complete all as specified and directed.
S&F in repairs Switch socket combination outlet 15 Amp, 5-in-1, controlled by one switch complete all as specified and directed.
S&F in repairs Switch flush button, single pole two way, 6 Amp complete all as specified and directed.
S&F in repairs Socket type EME fan 5 step regulator switch/socket type for ceiling fan of suitable size complete all as specified and directed.
S&F in repairs Lamp holder/angle holder insulated body with black/white plate for batten fittings complete all as specified and directed.
S&F in repairs modular step type fan regulator 120 watt, AC, 220V, 50hz, complete all as specified and directed.
S&F in repairs modular switch 1 module 6 amp one way complete all as specified and directed.
S&F in repairs modular switch 1 module 16 amp one way complete all as specified and directed.
S&F in repairs modular socket 2 module universal type 5/6 amp one way complete all as specified and directed.
S&F in repairs modular socket 2 module universal type 6/16 amp one way complete all as specified and directed.
S&F in repairs modular bell push 6A 1 module complete all as specified and directed.
S&F in repairs Bell buzzer, ding dong AC,230V, 50hz single pole complete all as specified and directed.
S&F in repairs modular cover plates with frame up From 1 /2 to 3 module as per site requirements complete all as specified and directed.
S&F in repairs modular cover plates with frame up from 4 to 12 module as per site requirements complete all as specified and directed.
S&F in repairs modular metal flush box as per site requirements from 1/2 to 3 modules complete all as specified and directed.
S&F in repairs modular metal flush box as per site requirements from 4 to 12 modules complete all as specified and directed.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 4.0 Sqmm (with colour code), drawn in and including non metallic rigid PVC conduit of 25/20mm dia/casing capping/ suitable size, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surfaces/ recess including taking down existing submain wiring complete all as specified and directed. Note: - Two runs of 4.00 sqmm cable and one run of 4.00 sqmm cable of earth continuity conductor shall be measured as one unit length.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 6.0 Sqmm (with colour code), drawn in and including non metallic rigid PVC conduit of 25/20mm dia/casing capping/suitable size, ISI marked with & including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess including taking down existing submain wiring complete all as specified and directed. Note: - Two runs of 6.00 sqmm cable and one run of 6.00 sqmm cable of earth continuity conductor shall be measured as one unit length.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 10.0 Sqmm (with colour code), drawn in and including non metallic rigid PVC conduit of 25mm/suitable size dia/casing capping/suitable size, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 10.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess including taking down existing submain wiring complete all as specified and directed. Note: - Two runs of 10.00 sqmm cable and one run of 10.00 sqmm cable of earth continuity conductor shall be measured as one unit length.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 4.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping/suitable size with & including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess including taking down existing submain wiring complete all as specified and directed. Note: - Two runs of 4.00 sqmm cable and one run of 4.00 sqmm cable of earth continuity conductor shall be measured as one unit length.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 6.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping/suitable size with & including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess including taking down existing submain wiring complete all as specified and directed. Note: - Two runs of 6.00 sqmm cable and one run of 6.00 sqmm cable of earth continuity conductor shall be measured as one unit length.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 10.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 10.00 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess including taking down existing submain wiring complete all as specified and directed. Note: - Two runs of 10.00 sqmm cable and one run of 10.00 sqmm cable of earth continuity conductor shall be measured as one unit length.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 2.5 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 20mm dia/casing capping/suitable size , ISI marked with & including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 2.5Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess including taking down existing submain wiring complete all as specified and directed. Note: - Two runs of 2.5sqmm cable and one run of 2.5sqmm cable of earth continuity conductor shall be measured as one unit length.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 2.5 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping/suitable size, with & including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 2.5 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess including taking down existing submain wiring complete all as specified and directed. Note: - Two runs of 2.5 sqmm cable and one run of 2.5 sqmm cable of earth continuity conductor shall be measured as one unit length.
M&L for cutting of wall/ceiling/column for laying submain wiring of any size including making good the surfaces as per existing complete all as specified and directed.
S&F in repairs 45 W LED building security light fitting with suitable size bracket/angle with three core flexible wire to fit security light IP 66 protection complete all as specified and directed.
S&F in repairs LED batten with 20/22W LED tube light approx 4 feet in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed and specified.
S&F in repairs LED batten with 24W LED tube light approx 4 feet in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as specified and directed.
S&F in repairs double door MCB DB made out of 18 SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP, 240 volts 100 Amps rated bus bar 12 way double door openable type, concealked on wall complete all as specified and directed.
S&F in repairs double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 8 way double door openable type, concealed on wall complete all as specified and directed.
S&F in repairs double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 4 way type, concealed on wall complete all as specified and directed.
S&F in repairs single door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 2 way type, concealed on wall complete all as specified and directed.
S&F in repairs double door MCB VTPN DB 4 way made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 4 way type, concealed on wall complete all as specified and directed.
S&F in repairs double door MCB TPN DB 4 way made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 4 way type, concealed on wall complete all as specified and directed.
S&F in repairs double door MCB VTPN DB 8 way made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 4 way type, concealed on wall complete all as specified and directed.
S&F in repairs 6 to 32 amp MCB single pole 240 V 10 KA (C-Series) complete all as specified and directed.
S&F in repairs SPN 32 AMP MCB DP 240 V 10 KA (C-Series) complete all as specified and directed.
S&F in repairs LED recess/surface mounted 2x2 luminarie 36w fitting, 220 V, AC, 50HZ suitable surge protection, high power factror,driver etc complete including flexible wire and connected accessories complete all as specified and directed.
S&F in repairs LED Bulk head fittings 9/10W luminaire including LED light driver holder 220 V, AC, 50HZ connecting up with three core flexible copper conductor calbe of suitable size complete all as specified and directed.
S&F in repairs LED tube rod 20 watt, 220V, AC, 50HZ change with existing any tube rod including flexible wire and connected accessories complete all as specified and directed.
S&F in repairs Batten MS suitable for 18/22/24W LED rod 220V,AC,50HZ with accessories including suitable 1.5 sqmm 2 core wire for connecting with ceiling rose complete all as specified and directed.
S&F in repairs LED batten 10w, 2 feet with LED tube light 220V,AC,50HZ in wall/surface connecting with all required accessories like flexible cable from ceiling rose etc complete all as specified and directed.
S&F in repairs MCCB 4 pole, thermal magnetic release range 100 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed.
S&F in repairs MCCB 4 pole, thermal magnetic release range 125 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed.
M&L for attending daily complaints by checking & repairing of DBs/meter panel board/circuits/submain wiring/switches /sockets etc and other connected work including rectification of faults using minor spares complete all as specified and directed
S&F in repairs MCCB 4 pole, thermal magnetic release range 63 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed.
S&F in repairs MCCB 4 pole, thermal magnetic release range 40 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed..
Taking out cover plate of bus conductor duct (of any size) of multistoreyied building, inspection, cleaning, servicing including replacement of rusted nuts bolts,insulators etc. cutting of damage end of outgoing cables and reconnection using proper size of cable lugs and preparation of old painted surface by scrapping and brooming down and including M&L for two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F in repairs three pin top of capacity 15 amp, AC, 220V complete all as specified and directed.
S&F in repairs PCRD plug of capacity 15 amp, AC, 220V complete all as specified and directed.
S&F in repairs epoxy coated connector of capacity 100A post type for bus bar trunking system complete all as specified and directed.
Taking out two wire from meter and bus bar/MCB SPN/SP (with safety) and replace it with & including 2 run of 6 sqmm wire of meter with suitable size of cable lugs both end and reconnection with meter and bus bar/MCB SPN/SP complete all as specified and directed. NOTE : Rate of lugs will deemed to be included in quoted rate by the contractor.
S&F in repairs existing sunken/terminal box of size approx 10cm x 10cm, concealed/surface mounted with & including hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed.
S&F in repairs existing sunken/terminal box of size approx 15cm x 7.5cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed.
S&F in repairs existing sunken/terminal box of size appro 20cm x 15cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed.
S&F in repairs existing sunken/terminal box of size approx 20cm x 25cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed.
S&F in repairs emergency bulb LED 10W, 230V, 50Hz with 2/4 hour backup complete all as specified and directed.
S&F in repairs round/square type, recessed /surface 12W/14W warm white LED downlight dimmable with high lumen 230V, compatible with Legrand Dimmer as per sample complete all as specified and directed.
S&F in repairs RCCBs 63 Amps double pole 100mA breaking capacity complete all as specified and directed.
S&F in repairs RCCBs 40 Amps double pole 100mA breaking capacity complete all as specified and directed.
S&F in repairs decorative light suitable for holder B-22/E-27 complete all as specified and directed.
M&L for taking out and refixing of tube light, mirror light etc after cleaning and any type rectifiying defect using minor spares, etc complete all as specified and directed.
S&F in repairs LED batten with 20/22W LED tube light (four feet) with sensor in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as specified and directed.
S&F in repairs LED batten with 9/10 W LED tube light two feet mirror type with sensor in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as specified and directed.
S&F in repairs LED batten with 20W LED tube light (four feet) with inverter type with 2 hrs backup in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as specified and directed.
S&F in repairs led bulb of 9/10 watt complete all as specified and directed.
M&L for servicing and cleaning of geyser of any capacity including taking out from existing position and refixing after reapirs complete all as specified and directed.
M&L for checking of ceiling fan of size 1200/1400mm and changing of defective parts, cotter pin/ nut bolt etc complete all as specified and directed.
M&L for earthing with GI earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) type B1 using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering, 40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test point including testing on completion and taking down old u/s materials complete all as specified and directed. NOTE: (i) The earth chamber shall be constructed 0.50m away from the edge of earth pit and the cost of the same is deemed to be included in quoted unit rate. (ii) GI Strip and protection pipe upto 7.5m is deemed to be included in the quoted unit rate. (iii) GI watering pipe upto 1.2m s deemed to be included in the quoted unit rate.
S&F in repairs GI strip 32mm x 6 mm with saddle in wall for loop earthing and ground grid complete all as specified and directed.
S&F in repairs fan rod of size 1/1.5 feet suitable for mounting ceiling fan of size 1200/1400 mm complete all as specified and directed.
Supply, laying, jointing, connecting & testing XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts/ of the following sizes including taking out cable cover & cable complete all as specified and directed:-
4 core 25 Sqmm
4 core 35 Sqmm
2 core 10 Sqmm
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in any type of soil including taking out faulty cable/cable covers and GI pipe complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed.
Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point complete all as specified and directed.
M&L for dry river sand as sand cushioning for protection of UG cable including punning of sand in layers complete all as specified and directed. NOTE: Punned thickness shall be measured for payement purpose.
Supply & laying un-reinforced precast concrete cable cover class LV type 1, flat size 250mm x 150mm x 40 mm complete all as specified and directed.
Taking out old un-reinforced precast concrete cable cover class LV type 1, flat size 250mm x 150mm x 40 mm complete all as specified and directed.
Laying only un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm complete all as specified and directed.
M&L for 50mm bore GI pipe light grade with all fittings laid in trenches including taking down old pipe of any size complete all as specified and directed.
S&F in repairs flexible wire 1 sqmm X 2 core complete all as specified and directed.
S&F panel board consisting of space to fix 9 nos meter with & including providing 9 nos MCB DP 40 with enclosure for protection of meter, double door type, fixed type, wall mounted with 2 to 3mm thick CRCA sheet enclousure duly powder coated. The rates including taking down old meter and connecting in new panel with required wires with out any extra cost, aluminium bus bar vertical type different colour consisting of the following complete all as specified and directed.:- INCOMING (i) MCCB 100 AMP 4 P 25 kA thermal magnetic based with o/c, s/c protection & ROH - 01 No (ii) Indicating lamps RYB- 03 Nos. (iii) Digital type voltmeter and ammeter. OUT GOING :(i) 40 amp MCB DP 10 kA with enclosure- 9 Nos. (ii) Space for refixing existing/Automatic meter electrical meter -09 Nos. NOTE- Contractor shall visit the site to prepare panel as per size requirements to fit in below stair case.
S&F panel board consisting of space to fix 5 nos meter and providing 5 nos MCB DP 40 with enclosure for protection of meter, double door, fixed type, wall mounted, with 2 to 3mm thick CRCA sheet enclousure powder coated. The rates including taking down old meter and connecting in new panel with required wires with out any extra cost, aluminium bus bar vertical type different colour consisting of the following complete all as specified and directed.:- INCOMING (i) MCCB 100 AMP 4 P 25 kA thermal magnetic based with o/c, s/c protection & ROH - 01 No (ii) Indicating lamps RYB - 03 Nos. (iii) Digital type voltmeter and ammeter. OUT GOING : (i) 40 amp MCB DP 10 kA with enclosure - 5 Nos. (ii) Space for refixing existing /Automatic meter electrical meter -06 Nos. NOTE- Contractor shall visit the site to prepare panel as per size requirements to fit in below stair case.
S&F in repairs modular type AC box with three pin socket and plug top and 20 amp with & including 1 no. single pole MCB 20 amp, C-series complete all as specified and directed .
S&F in repairs two way sheet metal enclosure with three pin socket and plug top with & including 1 no. 20 amp single pole MCB, C- series complete all as specified and directed .
BALAJI TRADERS (BID ID -3337019)
Shri Krishna Trading Corporation (BID ID -3337499)
K N CONSTRUCTION (BID ID -3337980)
M.K Enterprises (BID ID -3337953)
Om Sai Enterprises (BID ID -3337476)
venus enterprises (BID ID -3337271)
VARDHAMAN CONSTRUCTION COMPANY (BID ID -3338176)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .