Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.7 LAccepted-AOC | L1 | Accepted-AOC DUE TO L1 | |
| 2 | L2₹42.3 L+₹3.6 L (9.26%)Rejected-AOC RZF 498 MG MARG RAJ NAGAR II PALAM DELHI CANTT 110077 | NEW DELHI | DELHI | 110077 | L2 | Rejected-AOC HIGHER RATE | |
| 3 | L3₹42.5 L+₹3.8 L (9.72%)Rejected-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-AOC HIGHER RATE | |
| 4 | Rejected-Technical 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | - | Rejected-Technical Reject due to required category not found |
Tender Value
Refer Docs
EMD Value
₹87,292
Closing Date
9 Nov 2023, 6:00 pmClosed
GE NEW DELHI
GE NEW DELHI, SP MARG NAR ABHM GATE NO 5
ADDN/ALTN TO CORRIDORS OF ROOM NO 42, KASHMIR HOUSE FOR HOUSING OF SERVERS FOR PROJECT NGF AND DIA THIN CLIENT OF HQ IDS UNDER GE NEW DELHI
2023_MES_622204_2
NIT No GE/ND-64/2023-24
Open Tender
Miscellaneous Works
Item Rate
270 days
GE NEW DELHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE NEW DELHI
₹87,292
Yes
15 Jan 2024
27 Oct 2023
11 Nov 2023
27 Oct 2023
9 Nov 2023
27 Oct 2023
Amount
Taking down chowkhats or frame without taking off shutters exc 1.50 sqm but n.exc 4.0 sqm .
M&L for factory made solid WPC (wood particle composite) of approved colour door frame of size 100mmx63mm single rebate 100% lead free made from single extruded process material with density 0.78 Kg/RM complete all as speicifed and directed. Make : Echon/Rajshree or equivalent marke in approved list of CEWC and as approved by GE
S&F 30mm factory made solid WPC (Wood particle composite) moulded door shutter single extruded with 2.4 or 6 raised panel design on the front side with 10mm deep moulded on single sise with wooden grain texture. The density of the door shutter shall not be less than 600 Kg/Cum. 100% lead free door complete all as specified and directed. Make : Echon/Rajshree or equivalent marke in approved list of CEWC and as approved by GE
Dismantling wall & ceiling boards of any description as in panelling ceiling, partition, cup boards etc incl cover fillets in any surfaces complete all as specified and as directed
M&L for providing and fixing False ceiling at any height with semi perforated 12mm thick mircro tegular edge GRG (Glass Fiber Reinforced Gypsum) false ceiling tiles of size 595x595mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.85 (with 50mm thick glass wool) as per IS 8225 :1987, Noncombustile as per BS 476 (part-4) -1970 and light reflectance of 75-85% to be laid in true horizontal level or in slope as per site requirement suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @ 120 grams per sqm including both sides) Comprising of main - T runners of size 15x32mm of length 3000mm, cross-T of size 15x32mm of length 1200mm and secondry intermediate cross T of size 15x32m of length 600mm to from grid module of size 600x600mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fastners, 6mm dia fully threaded hanger rod up to 1000nn length and L shape level adjuster of size 85x25x2mm. Galvanized iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/partion with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wass SS screws. The work shall be carried out as per specificatons, drawing and as per direction of Engineer-in-Charge complete all as specified and directed.
S&F prelaminated PVC rigid foam sheet wall panelling of 5 mm thick stuck on inner frame work of 35 mm wide strips of 5 mm thick rigid foam sheet. The strips should have a groove of 6 mm width and 2 mm depth for sinking the head of screw used to fix the strips to the all and should be placed vertically at equal intervals of 300 mm C/C. The PVC strips to be fixed to the all using 65 mm long MS screws through the groove in the strip by using PVC fasteners including necessary moulding work on doors, windows, pillers and opening etc complete all as directed at site Note:- (a) Work for fixing of wall panelling shall be got executed through manufacturers authorised applicators only under the close supervision of their technical staff. (b) The entire qty of wall panelling and their allied ancillaries shall be procured directly from the manufacturer or their authorised dealer only.
S&F powder coated aluminium partition n.exc 1.20 Sqm in each panel using 95.6 mm x 44.8mm x 1.6mm frame work with 12 mm thick exterior grade veneered particle boards with decorative veneers on both faces/5.50 mm thick frosted glass as directed by Engr-in-Charge including aluminium beading for fixing board (Make: GLASS Make MODI/ FLOAT/ ATUL).
S&F powder coated aluminum door using 96.6mm X 44.8 mm X 1.6 mm aluminium chowkhats 84.0 x44.7mmX1.6mm section vertical styles 101.60X44.88X1.6mm rails including mortice lock vertical type mild steel 100 mm size (Make : Godrej/Harrison) 02 Nos tower bolt 150 mm , door handles, SS butt hinges 125 mm 04 Nos, hydraulic door closer and fittings complete all as specified and directed by Engr-in-Charge bottom panel with 12 mm thick laminated Novapan and top panel with 5.5 mm thick plain glass fixed with snap beading rubber of suitable size Make of glass (MODI/FLOAT/ATUL).
M&L for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) confirming to Fe 410 -W (Gde E- 250) quality A comlete all as specified and as directed
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius in CM 1:6 with old size bricks complete all as specified and as directed.
M&L for 15 mm thick ready mix plaster on brick or concrete surfaces of wall in two layers (thickness of each layer not more than 10 mm finished even & smooth. The first layer shall be prepared as per manufacturer instructions, relevant IS code and Engineering practices. The complete work of this item shall be executed only by a skilled labour of the trade complete all as specified and directed by Engr-in-Charge
S&F ZEBRA venetian blinds horizontal type incl guide rail, pulling thread etc incl taking down existing pelmets.
Taking down carefully old point wiring (Light / Fan/ Socket/ Bell Point ) with aluminium/ copper conductor cable complete including fittings such as ceiling rose, holders, regulators, bell, switch and socket from existing concealed conduits and making good the disturbed surface of wall/ floor complete to match with the existing surface/finishes complete all as specified and as directed.
Material and labour for point wiring with PVC insulated unsheathed multi stranded, single core, FRLSH, copper conductor cable of size 1.5 sqmm 1100 Volts including one run of PVC insulated unsheathed multi stranded, single core, FRLSH , copper conductor cable of size 1.5 sqmm as earth continuity conductor connected to common earth dolly drawing through PVC concealed conduit but including provision of new galvanised modular concealed box with suitable back & front plate for housing the modular switches, sockets & fan regulators for the following :-
One light/fan point controlled by one No., one way switch.
One 6 Amp socket outlet point controlled by one No., one way switch on same board
One 6 Amp socket outlet point controlled by one No., one way switch on independent board
One 16 Amp socket outlet point controlled by one No., one way switch on independent board with cable of size 2.5 sqmm 1100 Volts including one run of size 1.5 sqmm as earth continuity conductor complete all as specified and as directed. Note : - . (i) No cutting shall be done in the roof for laying PVC conduit for ceiling point wiring. In this specified portion wire shall run through the existing conduit or surface new conduit shall be provided as required. (ii) In case the wiring is encountered with any beam/column, then the wiring will run on surface to avoid any damage to the RCC portion.
S&F modular switch with cover plate 1 way 6 Amp, SP, one module 230 volts AC complete all as specified and as directed.make :indoasian cat part -810700 or equivalent
S&F modular switch with cover plate 1 way 16 Amp, SP, one module 230 volts AC complete all as specified and as directed.make -indoasian cat part-810701
S&F in replacement modular socket with cover plate outlet 2/3 pin combined 6 Amp, 230 volts two module AC complete all as specified and as directed.make indoasian cat part 810719 or equivalent
S&F in replacement modular socket with cover plate outlet 2/3 pin combined 6/16 Amp, 230 volts two module AC complete all as specified and as directed.make ;Indoasian cat part 810721
Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type , glare free light complete with driver complete.
M & L submain wiring size of cable 2 x10 sqmm complete along with cable 1x 10 sqmm FRLSH type for continuous earth wire and connected to common earth dolly complete all as specified and directed. Note :- Two run of 10.0 sqmm copper conductor cable,one run of 10 sqmm copper cable and one run of PVC conduit shall be measured as one unit length
M & L submain wiring size of cable 2 x6 sqmm complete along with cable 1x 6 sqmm FRLSH type for continuous earth wire and connected to common earth dolly complete all as specified and directed. Note :- Two run of 6.0 sqmm copper conductor cable,one run of 6 sqmm copper cable and one run of PVC conduit shall be measured as one unit length
M & L submain wiring size of cable 2 x 4 sqmm complete along with cable 1x4 sqmm FRLSH type for continuous earth wire and connected to common earth dolly complete all as specified and directed. Note :- Two run of 4 sqmm copper conductor cable,one run of 4 sqmm copper cable and one run of PVC conduit shall be measured as one unit length
Supply and fix in replacement of factory made concealed sheet steel distribution boards, double door, SPN, 12 way, 230 volts AC, IP 43 with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing complete all as specified and directed.
Supply and Fix in replacement factory made 4 way load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 4 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as outgoing complete all as specified and directed. Note : Rate of MCCB TPN 125 Amp included in the quoted rate
Supply and fix in replacement MCB SP 5-32 Amp, 10kA complete all as specified and directed.
Supply and fix in replacement MCB SPN 40-63 Amp, 10kA complete all as specified and directed.
Supply and fix in replacement MCB SP 40-63 Amp, 10kA complete all as specified and directed.
Supply & FIX in replacement Modular AC box complete with MCB 20-32 Amp, 230 volts AC complete all as specified and directed.
Supply, installation, testing and commissioning of Split Air-conditioner with inbuilt stablizer of upto (5KVA) of cooling capacity 2 TR consisting air cooled copper condenser coil , suitable for working on single phase 230V,50Hz power supply etc. complete in all respect.Rating as per E-in C's policy during installation .
S & F conduit pipe 20mm for LAN/TV/telephone/internet wires concealed into wall or above the fall ceiling for each computer table as per the site requirment complete all as specfied and directed
S& F modular type socket for LAN connection/telephone conncetion /USB connection complete all as specified abd directed NOTE : Make and module of socket must be same as that of switch boards
Supply and installation of 62.5 KVA silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per relevant IS norms and Alternator as per relevant IS norms complete with relay panel and switch gears And AMF panel Note : PCC foundation, MS sheet shed 15x15x12 ft & MS wire mesh caging of of size 15x15 ft with provision of entry gate (as directed by Engr in Charge ) included in the quoted rate
M & L 185 sqmm XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade.
M&L 50 sqmm XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade
Supply installation testing and comissioning Fire fighting system for the server room and connected area. Note :The designe of fire fighting s/m to be approved by the accepting officer before installation .The contractor will submit certificate of compeletion of work of similar nature of fire fighting before intallation
Fire extinguisher 5/6 kg gas operated automatic type
Single Loop networkable addressable type fire alarm control panel with touch-screen.
addressable type optical smoke + heat detector(multi) incorporate an LED, clearly visible from the outside, to provide in-dication of alarm or fault actuation.
Response indicator as per technical specification etc. as required.
sounder incorporate an integral line isolator
manual call point to monitor and signal to the control and indicating equipment status. Provide an integral red LED to indicate activation.
GI Box suitable for installation of detectors on true Ceiling
2x1.5 sq.mm 1.1KV grade copper conductor armored FRLS as per specifications in cable trays, clamped including anchor fasteners to wall with suitable clamps, saddles fixing bolts.
EXIT light, self contained 6W luminaire complete with flush mounting frame ,sign label,fluorescent tube and battery and with label EXIT/RIGHT/LEFT/UP/DOWN as required..
Earthing complete with copper earth electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level with top edge of the earth plate st a depth not less than 1.5 m below ground level connected to and including copper strip of size 20x3 mm by means of nut ,bolt ,check nut and washer etc made of copper alloy and connectio to tst point and earth dolly all as shown in electrical plate No 3 SSR part I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber ,precast 50 mm thick in cement concretet (1:2:4) type B1 with CI frame funnel ,GI pipe 20 mm bore medium grade for waterring and 40 mm bore GI pipe medium grade for protection and test point complette . Note : GI strip up to 7.5 mtr length shall be included in this item rate evel) with top edge of the pl
M & L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in GI pipe or fixed to poles or any other indicated situation for loop earthing etc. as required coper strip 20x3 mm complete from the machineries /plants up to the test point all as directed by engr in charge
Supply and fix Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw all as directed
S & F GI pipe light grade including all GI fittings fixed on wall ,laid under floor /roads of size 40 mm dia bore for cable protection all as directed
supply and fix cable tray made of GI (dimensions width 300mm to 600mm and deptrh 150mm to 300mm ) suitable to put under flooring for laying LAN/TV cable and otherelectric wires completet all as specified and directed .Note: material required such as nut bolts ,L shaoed angle made of MS and other welding work included
S and fixing of Digital smart door lock for home /offices with RFID,fingerprint ,Pin code and remote access .there is an inbuilt doorbell in this lock with low batter indiaction ,and recording history .Fingerprint capacity upto 100,password capacity upto 100 suitable for non sliding glass doors completet all as specified and directed
M & L accessories for LAN conncetion including fixing to the wall or laying above false ceiling with clipo/clamps/gitti/pench/bend etc
CAT 6 UTP cable for LAN
2m patch cable
1m patch cable
9 U wall Rack
Patch panel for rack
IO gang box with faceplate with keystone jack
Fiber optic LIU Box
Fiber cable
Fiber patch cord
Casin capin
Supply and fixing CCTV camera wired networking ,advamced night vision up to distance 30 mtr even in total darkness ,Records every image in crystal-clear 3 MP definition completet all as specified and directed .NOTE : connecting to system using conduit /cacin capin included in the quoted work .
Supply and fix UPS for 30 min back up three phase AC input 300 to 450V and out put 415 V ± 1% of capacity 12.5 KVA
MRITUNJYA ASSOCIATES
RUCHIKA ENGG.WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .