Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.9 CrAdmitted-Finance | -11.95% | ₹4.9 Cr | L1 | Admitted-Finance |
Tender Value
₹5.6 Cr
EMD Value
₹11.2 L
Closing Date
2 Feb 2026, 6:00 pmClosed
GM RSRDC LTD JAIPUR
GM RSRDC LTD SETU BHAWAN, JHALANA DOONGARI, JAIPUR
SITC of MGPS and MOT Works at Medical Hospital Banswara
2026_RSRDC_531341_1
RSRDC NIT No. 651/2025-26 Dated 22.01.2026 Sl No 2
Open Tender
Construction Works
Percentage
240 days
Medical Hospital Banswara
PLEASE REFER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹5,900
PD RSRDC ELECT I JAIPUR THROUGH NEFT/RTGS/IMPS
₹11.2 L
PD RSRDC ELECT I JAIPUR
10 Feb 2026
23 Jan 2026
3 Feb 2026
23 Jan 2026
2 Feb 2026
24 Jan 2026
30 Jan 2026
SITC of Oxygen Manifold System (16+16) with tail pipes NRV -manifold system comprise of bank of 16+16 cylinders (Bulk cylinder of D type) capacity manifold high pressure copper pipe of size 1/2"ID x14 swg (approx. 2.0320 mm) & high pressure fitting made of high tensile strength brass be used to connect the cylinders to the header assemblies with 32 no's non return valves & 32 no's high pressure flexible tail pipe is made of copper pipe of 1/3"x16 swg (approx. 1.6256 mm) the manifold is hydraulically tested at 225kg/cm2 pressure it is also degreased and is to be offered duly wrapped in a polythene bag make CE Approved/CE certified Note : Providing of Cylinders is in the scope of Hospital / End Client.
S/1/T/C of Fully Automatic Oxygen Control Panel, as per HTM-2022/02-01 of UK NFPA99C of USA as per enclosed technical specifications - (Imported) (European CE with 4 digit notafied body no / UL Listed)
S/1/T/C of Oxygen Outlets (imported) as per HTM-2022/02-01 of UKINFPA99C of USA as per enclosed technical specifications - (Imported) (European CE with 4 digit notafied body no / UL Listed
SITC of Oxygen emergency system - Emergency manifold system comprise of bank of 6+6 cylinders (Bulk cylinder of D type) capacity manifold high pressure copper pipe of size 1/2"ID x14 swg (approx. 2.0320 mm) & high pressure fitting made of high tensile strength brass be used to connect the cylinders to the header assemblies with 12 no's non return valves & 12 no's high pressure flexible tail pipe is made of copper pipe of 1/3"x16 swg (approx. 1.6256 mm) the manifold is hydraulically tested at 225kg/cm2 pressure it is also degreased and is to be offered duly wrapped in a polythene bag. One High pressure Imported and approved make Double gauge regulator with manual pressure setting option and showing cylinder and line pressure make CE Approved/CE certified Note : Providing of Cylinders is in the scope of Hospital / End Client.
S/1/T/C of Oxygen probes (imported) as per HTM-2022/02-01 of UKINFPA99C of USA as per enclosed technical specifications - (Imported) (European CE with 4 digit notafied body no / UL Listed
SITC of BPC (back pressure compensated) flow meter with humidifer made of nickel plated body , double jacketed with flow gradations marked on it . Desired flow will be setteled through rotary knob . Flow range should be between 0 to 15 1pm & work should be executed as per direction of engineer in charge .
MEDICAL NITROUS OXIDE SYSTEM
SITC of Nitrous Oxide Manifold System (4+4) with tail pipes NRV - manifold system comprise of bank of 4+4 cylinders (Bulk cylinder of D type) capacity manifold high pressure copper pipe of size 1/2"ID x14 swg (approx. 2.0320 mm) & high pressure fitting made of high tensile strength brass be used to connect the cylinders to the header assemblies with 8 no's non return valves & 8 no's high pressure flexible tail pipe is made of copper pipe of 1/3"x16 swg (approx. 1.6256 mm) the manifold is hydraulically tested at 225kg/cm2 pressure it is also degreased and is to be offered duly wrapped in a polythene bag make CE Approved/CE certified Note : Providing of Cylinders is in the scope of Hospital / End Client
S/1/T/C of Fully Automatic N20 Control Panel, as per HTM-2022/02-01 of UKINFPA99C of USA as per enclosed technical specifications - (Imported) (European CE with 4 digit notafied body no / UL Listed
SITC of Nitrous Oxide emergency system - Emergency manifold system comprise of bank of 1+1 cylinders (Bulk cylinder of D type) capacity manifold high pressure copper pipe of size 1/2"ID x14 swg (approx. 2.0320 mm) & high pressure fitting made of high tensile strength brass be used to connect the cylinders to the header assemblies with 2 no's non return valves & 2 no's high pressure flexible tail pipe is made of copper pipe of 1/3"x16 swg (approx. 1.6256 mm) the manifold is hydraulically tested at 225kg/cm2 pressure it is also degreased and is to be offered duly wrapped in a polythene bag. One High pressure Imported and approved make Double gauge regulator with manual pressure setting option and showing cylinder and line pressure make CE Approved/CE certified Note : Providing of Cylinders is in the scope of Hospital / End Client.
S/1/T/C of N20 Outlets (imported) as per HTM-2022/02-01 of UKINFPA99C of USA as per enclosed technical specifications - (Imported) European CE with 4 digit notafied body no / UL Listed
S/1/T/C of N20 probes (imported) as per HTM-2022/02-01 of UKINFPA99C of USA as per enclosed technical specifications - (Imported) European CE with 4 digit notafied body no / UL Listed
MEDICAL COMPRESSED AIR SYSTEM
S/1/T/C of Air Compressor with Compressed air plant complete pacakage unit total capacity 4500 LPM (imported) - as per HTM 2022/02-01/ NFPA99C as per enclosed technical specifications (European CE with 4 digit notafied body no / UL Listed
S/1/T/C of Air-4 Bar Outlets as per HTM-2022/02-01 of UKINFPA99C of USA as per enclosed technical specifications - (Imported) (European CE with 4 digit notafied body no / UL Listed
S/1/T/C of Air-4 Bar probes, as per HTM-2022/02-01 of UKINFPA99C of USA as per enclosed technical specifications - (Imported) (European CE with 4 digit notafied body no / UL Listed
SIIITIC of Air-7 Bar Outlets , as per HTM-2022102-01 of UKINFPA99C of USA as per enclosed technical specifications - (Imported) (European CE with 4 digit notafied body no / UL Listed
SIIITIC of Air-7 Bar probes, as per HTM-2022102-01 of UKINFPA99C of USA as per enclosed technical specifications - (Imported) (European CE with 4 digit notafied body no / UL Listed
MEDICAL VACCUM CENTRAL SYSTEM
S/I/IT/C of Vacuum central system with pump only complete pacakage unit total capacity 7500 LPM (imported) - as per HTM 2022/02-01/ NFPA99C as per enclosed technical specifications and list of approved makes (European CE with 4 digit notafied body no / UL Listed
SIIITIC of Vacuum Outlets , as per (imported) HTM-2022102-01ofUKINFPA99C of USA as per enclosed technical specifications - uropean CE with 4 digit notafied body no / UL Listed
SIIITIC of Vacuum probes, as per (imported) HTM-2022102-01ofUKINFPA99C of USA as per enclosed technical specifications - European CE with 4 digit notafied body no / UL Listed
SITC of suction unit (Suction Controller and Collection Jar) with posibility to configure required capacity capacity collection Jar and should meets the requirements as per BSEN ISO 100793:2009. The unit must designed to operate with the vaccum line of MGPS. The collection Jar must accumpained with Vaccum regulator suitable for 0-14.7 psig with flow rate 0-55 Lmp (min) for operating temperature - 18°C to 50°C with ON/OFF facility. The collection Jar should be transparent, made of high quality polycarbonate that can be autoclaved at 121°C for 20 minutes for reuse and provided with auto stop to avoid over spill and contamination of the suction source when the jar collection reached optimized level. The complete unit supplied with filter to protect the source and pipe line from bacterial contamination.
600 m1 Capacity collection Jar
Supply, Installation, testing & commissioning of Theatre Vacuum Unit (2 jar nos capacity 2000 Ml) ( Imported) European CE with 4 digit notafied body no
SITC of MGPS of medically grade as per BSEN-13348 with third party certification from Lloyds/TUV, degreased (ie free from oil, grease and particulate matters) seamless copper pipe confirming to ASTM B88 and all copper joining done by brazing with AWSA5.8, classification BCuP-5 or BS 1845 following procedure in accordance with ASTM B828 after purging with nitrogen. All pipe cutting shall be carried out with a radial pipe cutter and copper pipe fitting's shall comply with B4 alloy designation. Adequate support shall be provided while laying pipeline testing shall be done at 17 bar and after testing pipe shall be painted with two coat of enamel paint as per colour codification as per ISO 7396-Part-I 2016.
SITC of Valve box made of CRCA sheet duly powder coated with transparent window which is installed in the MGPS for oxygen and vaccum line and should comply with ENIS05211:2001 complete with ball type valves and gauses as required for oxygen compressed air and vaccum line (three gas)
For Two Gas
For Three gas
For Four gas
For Five gas
SITC of microprocessor based auto alarm system (digital type) suitable for medical gas service provided with audible and visual alarm for MGPS Zoning. It should monitors the current status of oxygen /compressed air pressure in distribution pipeline of central medical supply system and trigger the alarm to alert. The system should comply BSEN ISO:7396-1:2007
For Two Gas Services
For Three Gas Services
For Four Gas Services
For Five Gas Services
SITC of non lubricated ball type GM Isolation Valve with adapter & PTFE Seat having quarter turn handle opening of following sizes suitable for flow capacity 1500 LPM at 4.7 bar with maximum allowable pressure of 30 bar and suitable for working temperature ranging - 20°C to 130°C.Valve should be CE approved/ CE certified.
For 12 MM OD pipe
For 15 MM OD pipe
For 22 MM OD pipe
For 28 MM OD pipe
For 42 MM OD pipe
For 54 MM OD pipe
SITC of Bed Head Panel of 1200 -1500 MM long made out from high strength extruded aluminium with powder coating with 4 nos 6/16 Amp switch socket and provision forfour Nos gas outlet point work should be executed as per directions of engineer in charge and of CE certified makes.
P&F of Bed Panel accessories like Monitor Tray, Utility Basket, Vacuum Slider, Infusion Pump Pole with IV hooks, with proper nut bolts and screw and with proper finishing & work should be executed as per directions of engineer in charge of CE certified/ CE Approved .
Monitor Tray
Utility Basket
Vacuum Slider
Infusion Pump Pole
Sub: Modular Operation Theater 03 Nos
S/1/T/C of SS 304 sandwitch puf panel Walls and ceiling for of Operating Area as per tender technical specification enclosed
S/1/T/C of paint as pertender technical specification enclosed
SITC of recess mounted cleanroom flat LED panel of 595 x 595 mm size as per specifications
S/1/T/C of Touch Surgeon control panel, mounted flush in the theatre wall, complete set with electrical Distribution Board, as per enclosed tender technical specifications (Imported).
S/1/T/C of Twin Plate X-ray viewing Screen designed to provide a high level of control luminance without flicker. Size:- 1000x700x95 Deep, indigenous, complete set as per enclosed tender technical specifications. (Indian)
S/1/T/C of Seamless flooring with perfectly curved fish- covings resistance to mechanical stress and dynamic load and having Electro static discharge (ESD) I (anticonductive) protection characteristics 2 mm thick, washable- complete. As per enclosed tender technical specifications. (Imported)
S/1/T/C of Pass Box, Hatch should be provided in each Operation Theatre to remove waste materials from the operation theatre to the dirty linen area just adjacent to operation theatre- as per technical specification (Indian)
S/1/T/C of Scrub Sink- 3 bay- made in Stainless steel 304 Finish, having Sensor & Foot Operated with Thermostatic Mixing valve control to Size maintain the water temperature, Indigenous complete set, as per enclosed tender technical specifications.(lndian
S/1/T/C of Automatic Sliding door, Complete with Automation Unit, frame, viewing window. complete set, as per enclosed tender technical specifications. (extruded aluminium) (Indian)
Each 2100mm x 1500 mm (height x width of door frame)Automatic
Each 2100mm x 1000 mm (height x width of door frame)Automatic
S/1/T/C of LED OT light European CE Certified/UL listed I FDA as per technical specifications.(imported)
S/1/T/C of camera for OT light as per technical specifications.(imported)
S/1/T/C of Flat panel monitor as per technical specifications.(imported)
S/1/T/C of Single Arm Pendant with 1000mm long horizontal arm with both horizontal and vertical movemen , imported, as per CE Certified / UL Listed, complete set, as per enclosed tender technical specifications. (Imported)
S/1/T/C of Double Arm pendant with 1000mm+800mm long horizontal arms with both horizontal and vertical movement , imported, as per CE Certified/ UL listed, complete set as per enclosed tender technical specifications. (Imported)
S/1/T/C of writing board, indigenous, complete set as per enclosed tender technical specifications. (Indian)
S/1/T/C of PRD , indigenous, complete set as per enclosed tender technical specifications. (Indian)
S/1/T/C of Storage Unit , indigenous, complete set as per enclosed tender technical specifications. (Indian)
SITC of : Isolation Panel system with insulation monitoring and insulation fault location floor mounted dust and vermin proof (IP30) compartmentlaized cubical type 10 KVA medical isolation panels shall comfirm to following IEC statndard IEC 60364-7-710, IEC 61439-1 and -2, IEC 61557-8, IEC 61558-2-15 (IEC test certificate to be attached with panel) .The panel shall be fabricated out of 14 gauge CRCA sheet steel required hardware duly treated throgh 7 tank process for derusting. The panel door shall have trnsparant inspection window. The panel shall have following 1 no 10 KVA isolation transformer, 1 no Insulation monitor suitable for all outgoings, 1 no 63 Amp 10 KA 4 pole MCB, 12 nos 16/20 Amp 2 pole C curve MCB, all required suitable rating current transformer for incomer & outgoing, 1 no digital voltmeter & ammeter, suiatble for monitoring insulation fault, transfomer fault, insulation fault location. The panel shall be capable to perform insulation test. The Insulation monitor & fault locator should have inbuilt RS485 communication protocol. Panel shall be capble of detecting overheating of cables inside the OT isolation panel and sending alarm as well as alart over BMS. including making necessary connection etc complete in all respect of make PIECO / Bender /
SITC of 10 KVA 3 Phase Input, 3 Phase Output advance DSP controlled UPS with IGBT based rectifier, LCD display, double conversion / Digital Signal Processing UPS, with full load 30 minute battery back up, with required cabling for incoming & outgoing connection of as per enclosed technical specifications and & list of approved makes EMERSON / APC / NUMERIC / REILLO.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.34 MB
SBD.pdf
Tender Documents • 1.27 MB
Technicalspecifications.pdf
Tender Documents • 0.62 MB
circularofJV06062023.pdf
Tender Documents • 0.23 MB
BOQ_947061.xls
BOQ • 0.33 MB
various_Circulars_orders.pdf
Tender Documents • 1.42 MB
Engineering_Cost.pdf
Tender Documents • 0.38 MB
projectdirectorbankaccountnumberdetails.pdf
Tender Documents • 0.28 MB
AnnexureABCD_RTPPAct2012_AnnexureC.pdf
Tender Documents • 0.10 MB
Rs1000StampFeeforaffidavit.pdf
Tender Documents • 0.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .