Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 LAccepted-AOC NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹21.6 L+₹2.2 L (11.6%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹21.9 L+₹2.5 L (12.8%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹22.8 L+₹3.4 L (17.6%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹24.5 L+₹5.1 L (26.3%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
15 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR
REPAIR MAINT OF INTERNAL ELECTRIC SUPPLY FANS AND ALLIED WORKS IN TECHNICAL AND MES AREA AT AF STN GORAKHPUR
2023_MES_596605_1
9037/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE(AF) GORAKHPUR
Class d cat b i
8 documents required · 8 mandatory
₹500
Yes
GE(AF) GORAKHPUR
₹70,000
Yes
14 Aug 2023
19 May 2023
17 Jun 2023
19 May 2023
15 Jun 2023
2 Jun 2023
19 May 2023 - 27 May 2023
Amount
Taking down carefully point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
M&L for point wiring controlled by one 5A switch using 1.5 sqmm cable (nominal area) stranded copper conductor (FRLS), single core, PVC insulated and unsheathed cable, 1100 V grade in and including concealed PVC conduit of size not less than 20mm dia all as directed with sunken type pressed steel terminal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor PVC insulated and unsheathed cable as in earth wire connected to common earth dolly completed all as specified and directed for following :- (a) One Light/fan point controlled by one switch
(b) One 5 Amps socket point controlled by one 5 Amps switch on same board.
(c) One 5 Amps socket point controlled by one 5 Amps switch on independent board.
(d) One bell point controlled by one 5 Amps bell push.
M&L for point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wall with top cover and plate including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3 pin 15 Amps socket independent. Note for item Nos 2 to 7 :- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
M&L for point wiring controlled by one 5A switch using 1.5 sqmm cable (nominal area) stranded copper conductor (FRLS), single core, PVC insulated and unsheathed cable, 1100 V grade in and including PVC casing caping all as directed with sunken type pressed steel terminal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor PVC insulated and unsheathed cable as in earth wire connected to common earth dolly completed all as specified and directed. (a) One Light/fan point controlled by one switch
(b) One 5 Amps socket point controlled by one 5 Amps switch on same board.
(c) One 5 Amps socket point controlled by one 5 Amps switch on independent board.
(d) One bell point controlled by one 5 Amps bell push.
M&L for point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including PVC casing caping with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wall with top cover and plate including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3 pin 15 Amps socket independent. Note for item Nos 8 to 12 :- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
S&F switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed.
S&F socket outlet, 3/5 pin, 5/6 amps flush type complete all as specified and directed.
S&F socket outlet, two in one 3 pin, 5/6 & 15/16 amps flush type complete all as specified and directed.
S&F switch piano, flush type 15/16 amp, single pole, one way 240 volt complete all as specified and directed.
S&F bell push, flush type 5 amp, single pole, one way 240 volt complete all as specified and directed.
S&F ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed.
S&F fan regulator electronic step up type, SP 230 volt complete all as specified and as directed.
S&F lamp holder polycarbonate insulated body with back plate suitable for batten fittings complete all as specified and directed.
S&F Call bell ding dong, AC single pole 240 volts complete all as specified and directed.
Taking down old unserviceable light fittings conventional type from wall surface / ceiling or any position and making good the disturbed surfaces all as specified and directed.
S&F 10 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No. ENDURA LINE ARNE OBS10WLED865SPCWH or equivalent in Bajaj / CG.
S&F 20 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No. ENDURA LINE ARNE OBS20WLED865SPCWH or equivalent in Bajaj / CG.
S&F recess mounting LED luminaire of size 2'x2' white 34 watt, 230 volts for ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- Havells Cat part No. PLUTONEO2X2PLR34W LED840S or equivalent in Bajaj /CG.
S&F recess mounting LED luminaire round shape 12 watt, 230 volts for ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- Havells Cat part No.INTEGRAHEDLR12WLED840S or equivalent in Bajaj /CG.
S & F including testing LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
S&F including testing energy saving, die cast aluminium housing IP 65 protection, 25 W LED flood light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps, nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:-Havells Cat No. ENDURA CITYLITEPLAT PLUS SL25WLED 757S ASYBOPC or equivalent iin Bajaj/ Philips/ CG/ WIPRO
S&F including testing Inbuilt sensor based smart LED 40 WATTS, 6500K (Nuetral white) auto dimmable recess mounted Scene 2x2, made from C, white powder coated housing , opaque glore free diffuser for optimum light output pre wired with all accessories and all as per site requirement complete all as specified and directed. Make:-Shakti Fixture Pvt. Ltd . Cat No.SZRSRMX040-iSS or equivalent iin Bajaj/ Philips / CG/ WIPRO
Supply and in repairs including Installation of Smart RF Single Phase Meter with the following specifications: • AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt 865-867 MHz Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry.MAKE:L&T (cat part no WM101BC7DLPR6INN) or equivalent in Secure or Schneider.Notes: (1) Meters would have 5 years OEM Warranty. (2) The DCU /Gateway and software could be installed later if rquired.Make : L&T or HPL
S&F 40mm bore GI pipe, light grade with all fittings laid in trenches, road crossing and fixed to walls, on poles etc for cable protection complete all as specified and directed.
Supply and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed for service connections of 6 Sqmm size twin core flat solid conductor Service main cable complete from pole to distribution board main controlling switch complete all as specified and as directed.
S&F in replacement brackets made out of 40/50mm dia medium grade GI pipe 1.50 mtr long bent to shape and size fixed on location using new 2 nos 30x5mm FI clamps made to shape incl nuts, bolts & washers complete all as specified and directed.
Taking down carefully old and unserviceable sub main wiring of 2/3 runs or main-wiring of any size of aluminium conductor cable from any position including wood batten, PVC conduit, steel conduit, PVC Casing caping etc including making good disturbed surface of wall ceiling etc complete all as specified and directed.
M&L for sub main wiring with 2 Nos single core PVC insulated unsheathed 2.50 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 2.5 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 2.5 sqmm conductor cable, 1 No 2.5 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
M&L for sub main wiring with 2 Nos single core PVC insulated unsheathed 4.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 4.0 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 4.0 sqmm conductor cable, 1 No 4 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
M&L for sub main wiring with 2 Nos single core PVC insulated -unsheathed 6.0 Sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 6.0 Sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 6.0 Sqmm conductor cable, 1 No. 6.0 Sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
S&F sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one Triple pole MCB 32 Amp complete all as specified.
Taking down old unserviceable MCCB DBs / MCB DB / Main Switches including MCBs/ MCCBs/ Isolaters, complete all as specified and as directed. Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces.
S&F factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed.
S&F factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed.
S&F factory made epoxy powder coated distribution board SPN 12 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
S&F factory made epoxy powder coated distribution board SPN 8 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
S&F factory made epoxy powder coated distribution board SPN 4 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
S&F sheet metal enclosure distribution board SPN 2 ways complete all as specified and directed.
S&F MCCB, 4 pole, 63 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.
S&F MCCB, 4 pole, 100 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.
S&F MCCB, 4 pole, 125 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.
S&F MCB, SP, 6 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, SP, 40 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, SPN, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, TP, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, TPN, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified.
S&F sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one Triple pole MCB 32 Amp complete all as specified.
S&F in replacement U/S and broken exhaust fan (air freshener) single phase 230/240 volt AC 250mm sweep with louvers, plastic body, with twisted copper flexible wire 23/0.0076mm including taking down old fan and deposited in MES store complete all as specified and directed.Make: Havells/Bajaj/CG.
S&F in replacement U/S and broken exhaust fan (air freshener) single phase 230/240 volt AC 300mm sweep with louvers, plastic body with twisted copper flexible wire 23/0.0076mm including taking down old fan and deposited in MES store complete all as specified and directed.Make: Havells/Bajaj/CG.
S&F in replacment U/S and broken exhaust fan single phase 230/240 volt AC 450mm sweep, with painted louvers, metal body, with twisted copper flexible wire 23/0.0076mm including taking down old fan and deposited in MES store complete all as specified and directed. Make: Havells/Bajaj/CG.
S&F in replacement unsv wall mounted fan single phase 230/240 volt AC 400mm sweep, with regulator, oscillation type complete fixed properly on wall and connecting /testing as directed. Note Old unsv fan will be deposited to E/M store yard. Make: Havells/Bajaj/CG.
Repairing of light point (normal/ flameproof), fan point, socket point 5A/15A, switches sockets, fan regulator, light fixtures any type, lamp any type, MCB DB's & all electrical accessories in day to day/door to door maintenance and making it serviceable in all respect with replacement of any major part but including small length of wires (not more than 50cm) adhesive cable and other connected minor accessories by providing sufficient and skilled manpower. Work shall also include to check & removal of current leakages in Bldgs and any urgent nature of work as and when directed. The scope also include cutting of existing Bakelite sheet to accommodate new elect fittings/fixtures like switches, sockets, fan regulators etc. Note :- (a) The rate quoted by the contractor for Each complaint is deemed to be included consisting of minimum 03 complaints in working hours between 0900 AM to 0500 PM in Tech and MES area by engaging one electrician and one helper. (b) The contractor or his representative will take complaint from MES complaint Register through MES job card. (c) The contractor will made separate items register with location and signature of user. (d) The contractor will maintain complete details of Job cards (Working/Off working hours) and items involved with date and user signature. (e) The ladder and T&P as required will be provided by the contractor. (f) Risk factor & security pass will be the contractor's end. (g) Material will be measured and paid separately in the relevant item here after. (h) All supply material shall be deposited by contractor in MES store yard and issued in every Job Card as per requirement. (j) The tradesmen should be available at MES area complaint cell (In MES Complex), after completing their daily Job Cards as well as during off working hours / Night / Sunday / Holiday. (k) Any complaint will be attended within 3 hours as received from MES, failing which a panel recovery of Rs. 500/ Complaint will be revovered from the contractors dues and no dispute will be intertained tater date.
All as per Item No. 61 above but for attending the electrical complaints during off working hours / Night / Sunday / Holiday time for 12 hours. Note :- All as per item No 61 above but the rate quoted by the contractor for 'Each Job' is deemed to be included 01 complaint in Tech & MES Area
Supply only fan regulator electronic step up type, SP 230 volt complete all as specified and as directed.
Supply only switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed.
Supply only modular switch single pole 1 way, 1 module, 6 Amp complete all as specified and directed.
Supply only modular switch single pole 1 way, 1 module, 16 Amp complete all as specified and directed.
Supply only modular socket out let multipurpose 6A -2/3 pin, SP 1 way 2 module complete all as specified and directed.
Supply only modular socket out let multipurpose 6A/16A-2/3 pin, SP 1 way 2 module complete all as specified and directed.
Supply only modular bell push pole 1 way, 1 module, 6 Amp complete all as specified and directed.
Supply only switch socket combination multipurpose 5 pin 5/15 Amps
Supply only switch socket combination multipurpose 5 pin 5 Amps
Supply only switch piano, flush type 15/16 amp, single pole, one way 240 volt complete all as specified and directed.
Supply only socket outlet, 3/5 pin, 5/6 amps flush type complete all as specified and directed.
Supply only socket outlet, two in one 3 pin, 5/6 & 15/16 amps flush type complete all as specified and directed.
Supply only bell push, flush type 5 amp, single pole, one way 240 volt complete all as specified and directed.
Supply only ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed.
Supply only Call bell ding dong, AC single pole 240 volts complete all as specified and directed.
Supply only lamp holder polycarbonate insulated body with back plate suitable for batten fittings complete all as specified and directed.
Supply only Starter for tube light 36/40 watt, 240 volts complete all as specified and directed.
Supply only LED tube rod 18/20 watt (4ft), 240 volts complete all as specified and directed.
Supply only lamp LED 9/12 watt, 240 volts complete all as specified and directed.
Supply only tape insulation, 1100 volts grade 20mm width, 15 mtrs long complete all as specified and directed.
Supply only capacitor of capacity 2.5 mfd PVC body complete all as specified and directed. Make:- EPCOS/JYOTI/ USHA
Supply only capacitor of capacity 3.15 mfd PVC body complete all as specified and directed. Make:- EPCOS/ JYOTI/ USHA
Supply only single run of single core PVC insulated unsheathed cable of size 2.5 Sqmm, FR copper stranded conductor complete all as specified and directed.
Supply only wire flexible 23/0.0076, twin core twisted, PVC insulated copper stranded conductor complete all as specified and directed.
M&L in replacement for factory made gate light junction box, single phase, 2 wire, 240 volts, weather proof pole mounted made out of 1.63 mm thick MS sheet of size 250x150x100mm depth, with properly insulated aluminium buses - 02 Nos of 32 Amps rated current cap with holes for connecting of cables, hinged door and locking bolt, handle complete all as specified and directed.
Supply and fixing in replacement ceiling fan 5 star rated, 1200mm sweep , 230 Volts, 50 Hz AC, complete with blades,with anti suicide down rod, set of canopy and connecting up including three core PVC insulated multi stranded copper conductor cable of size 2.5 Sqmm wire which shall be passed through PVC flexible conduit, from ceiling rose/connentor to fan of length not less than 1.0 meter complete all as specified and directed.Note Old unsv fan will be deposited to E/M store yardMake: Havells/Bajaj/CG. Make - Usha/ Bajaj/ Havells
Supply & fix in replacement complete fan hanging assembly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans & down rods complete all as specified and directed.
Supply & fix in replacement 300mm long down rod 15 mm dia, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc. complete all as specified and directed.
Supply & fix in replacement 900mm long down rod 15 mm dia, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc. complete all as specified and directed.
M&L in repairs earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, burried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate ot less athn 1.50 m below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI lead wire of 4 mm dia.(7.50 m Long) by means of nuts, bolts and washers, checknuts of GI and protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe light grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wiremesh, earthing test point etc complete including necessary earth work and excavation in any type of soil , PCC 1:2:4 type B1 earth pit and Precast RCC cover 65 mm thick duly reinforced with 6 mm dia. MS round bars @ 100mm C/C both ways,with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SI Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
M&L in repairs earthing complete in replacment with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip of size 32/6mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
Taking out & removing old burnt-out winding and rewinding of motor of ceiling fans 1200/1400 mm sweep of any description and rewinding of fan motor with appropriate size super enameled copper wire approx 200 gram including insulating material such as illumines paper, letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of the department for the following Fans:- Make of winding wire: Atlas/Finolex/ Devi Dayal
All as per item No. 94 above but rewinding of motor of exhaust fans of 225/250 mm sweep with 170 gram winding wire.
All as per item No. 94 above but rewinding of motor of exhaust fans of 300/400 mm sweep with 200 gram winding wire.
All as per item No. 94 above but rewinding of motor of air circulating fan of 400 mm sweep with 300 gram winding wire.
All as per item No. 94 above but rewinding of motor of pedestal fan of 400 mm sweep with 400 gram winding wire.
PITAMBARI TRADERS
M/s A.K Construction
Yaduvanshi Traders
Unitech India
Pioneer Engineering works
DEEP ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .