Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.3 LAccepted-AOC | L1 | Accepted-AOC Acceptance | |
| 2 | L2₹27.8 L+₹51,208.50 (1.88%)Rejected-Finance WARD NO 02 LAKHUWALI PO THE PILIBANGAN DISTT HANUMANGARH RAJASTHAN 335803 | HANUMANGARH | RAJASTHAN | 335803 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹33.0 L+₹5.7 L (20.9%)Rejected-Finance 5 B5 JAWAHAR NAGAR IN FRONT OF KAPAS BHAWAN SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹34.2 L+₹6.9 L (25.4%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹34.9 L+₹7.6 L (27.9%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
7 Sept 2023, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
SPL REPAIR OF TOILET BLOCK OF BLDG NO P-12,PROVN OF CAR PARKING SHED, COLLAPSIBLE GATE AND CONSTRUCTION OF CEMENTED FLOOR UNDER AGE B/R-II AT SUARATGARH MIL STN
2023_MES_613544_1
GE (A) SOG - Token No 38/23-24
Open Tender
Civil Works
Item Rate
180 days
SURATGARH
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ARMY SURATGARH
₹92,000
Yes
7 Oct 2023
12 Aug 2023
9 Sept 2023
12 Aug 2023
7 Sept 2023
26 Aug 2023
Amount
Demolition of brick work, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-charge.
M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster or cement lime plaster on stone surface/brick surfaces of walls including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed by Engineer-in-charge.
M&L for 10mm thick rendering in cement mortar (1:6) on fair faced surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed.
M&L for 5mm thick rendering in cement mortar (1:3) on brick or concrete surface of ceiling, finished even & smooth without using extra cement complete all as specified and directed.
M&L for removing loose ceiling plaster completely, cleaning and dripping mortars and curing of effected surface area, cleaning well expossed reinforcement and applying two coats of anti-corrosive paint to it, supply and fixing mild steel XPM mesh of size 25mm x 25mm (wire dia min. 2mm) to the effected ceiling surface either by welding with exposed reinforcement or by stapling nails or screw or tie with reinforcement, applying cement slury and 25mm thick microphone of 1:1:1 using 6mm graded aggregate and cuting it for 3 days and then making well finish the surface using cement mortar 1:3 complete all as specified and directed by Engineer-in-charge.
M&L for 15mm thick rendering in cement mortar (1:4) on fairsurface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed.
M&L for rough cast finish plaster with a mixture consisting of crushed stone or fine gravel aggregate mixed with coarse sand and cement in the ratio of 1:1:1 over & including 12mm thick rendering in cement mortar 1:3 on fair faces of brick masonry or concrete surfaces of walls complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for
M&L 25 mm thick PCC type B-0, (1:2:4) using 12.50 mm graded stone aggregate complete all as specified and as directed by Engineer-in-Charge
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
M&L for non skid ceramic joint free coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:4) complete all as specified and directed.
M&L for glazed ceramic tiles (coloured) 450mm x 350mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) including necesary cutting as per site requirment complete all as specified and directed by Engineer-in-charge.
Taking down old rusted & damaged steel windows/ventilators of any description and of any type & size with guard bars / grill including cutting holes for hold fasts & making good the disturbed portion complete all as specified & as directed.
Taking down chowkat or frame with shutters including fitting and fixtures area not exc 1.5 Sqm each (without taking off the wooden shutters from the frame) including cutting holes for hold fasts and making good disturbed surface with cement mortor or PCC after fixing new chowkats complete all as specified and directed by Engineer-in-charge.
Taking down chowkat or frame with shutters including fitting and fixtures area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the wooden shutters from the frame) including cutting holes for hold fasts and making good disturbed surface with cement mortor or PCC after fixing new chowkats complete all as specified and directed by Engineer-in-charge.
S&F pressed steel frames for door of size 105x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc made out of mild steel sheet of 1.25mm thickness complete all as specified and as directed by Engineer-in-charge.
S&F 30 mm thick factory made plain framed, panelled shutter (any number of panels) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces. The size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated using second class Hard Wood (Hollock or Bonsum) complete all as specified and directed by Engineer-in-charge.
M&L for cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in filling of pressed steel frame and hold fast block etc.
S&F factory made Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube complete all as specified and shown in relevant drawing of Item No 08095 in MES schedule (Part-II) and directed by Engineer-in-Charge
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside ith solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F 100mm size mild steel butt hinges cold rolled medium weight (ISI marked) complete all as specified & directed by Engineer-in-Charge.
S&F 200 mm long mild steel barrel tower bolt stove enamelled black with bright bolt (ISI marked) complete all as specified & directed by Engineer-in-Charge.
S&F 300mm long mild steel sliding door bolts clip type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate (ISI marked) complete all as specified & directed by Engineer-in-Charge.
S&F as in repair 150mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring overall length of cover plate 140mm (ISI marked) complete all as specified and directed by Engineer-in-Charge.
S&F 150mm long extruded aluminium handles, anodised, fabricated type (ISI marked) complete all as specified and directed by Engineer-in-Charge
S&F 200 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F 100mm size butt hinges of extruded aluminium alloy with galvanized mild steel hinge pin, anodized type C-21 (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F 4 mm thick figured glass, pin headed n exc 0.5 Sqm Pane fixed with and including necessary rubber gasket and aluminium beading all as directed
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 mixing water proofing compound @3% by wt of cement finished even and smooth (without using exra cement) in sunken portion all as specified.
Demolition of cement concrete in sunken portion including floor tiles complete all as specified and directed by Engineer-in-charge.
M&L for PCC in 1:5:10 type E2 (using 40mm graded agg) as in filling in foundation as in sunken floor complete all as specified and as directed by Engineer-in-charge.
M&L for preparation sunken surfaces by cleaning of and removal of loose concrete and filling cracks with polymer modified mortar using Dr. Fixit Pidicrete URP or equivalent in Forsoc, thermax, sikka and other approved make and applying 2 coats of Dr. Fixit Bath seal WPC in suken areas and laying a protective plaster in 10mm thickness in cement mortar (1:3) admixed with Dr. Fixit Pidicrete LW + @ 220ML per bag of cement applying mix of cement water in the ratio 1:1:5 by volume using DR FIXIT PIDICRETE URP chemical on floor and vertical surface of sunken floor as per manufacturers instructions complete all as specified and directed by Engineer-in-charge.
S&F as in repairs vitreous china wash down water closet pan (Pedestal pattern), white including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc. & including plastic WC seat cover white closed pattern with flat bottom and cover including cast iron 'P' or 'S' trap, PCC filling and connection to trap and flushing pipe complete all as specified & as directed by Engineer-in-charge. .Make :- Cera Cat Part "S1053105", Parryware Cat Part No "C022O" and Cera Cat Part No "B1520103", Parryware Cat Part No "E8309"
S&F as in repair vitreous china squatting pan Orissa pattern, white of size 580x440mm with integral foot rests (excluding flushing cistern and flush pipe) including cast iron 'P' or 'S' trap, PCC filling and connection to trap and flushing pipe, antisyphonage pipe etc complete all as specified and directed by Engineer-in-charge. Make :- Parryware Cat Part No "C0117", Cera Cat Part No "S3020105"
S&F as in repairs Health faucets (ABS body) of made of stainless steel chromium plated connected for EWC suitable for 15mm bore pipe with 1.25m long flexible tube and ABS wall hook including making connection complete all as specified and directed Make :- Jaquar Cat Part No "ALD-CHR-573", Kohler Cat Part No "K-98100IN-CP", Jhonson Cat Part No "S0426C"
S&F as in repair 15mm bore angle valve, cast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge. Make: Jaquar Cat Part No "FUS-CHR-29053", Kohler Cat part No "76390IN-9-CP"
S&F as in repair 450mm long PVC connection suitable for 15 mm bore with PTMT nuts on both sides complete all as specified and directed by Engineer-in-charge.
S&F as in repair 600mm long PVC connection suitable for 15 mm bore with PTMT nuts on both sides complete all as specified and directed by Engineer-in-charge.
S & F in repairs shower arm 15mm size 195 mm long with bend of 45 degree with flange of PTMT any colour(Min weight 40 gms). Make :- Jaquar Cat Part No "SHA-CHR-477", Kohler Cat Part No "26318IN-CP"
S&F in repair, 15 mm bore shower rose, 125 mm size or size as per Cat part mentioned below in makes, brass chromium plated with sweivel joint all as directed. Make :- Jaquar Cat Part No "OHS-CHR-1661", Kohler Cat Part No "K-23152IN-CP"
Supply & fixing as in repair cast iron nahani trap 75mm outlet dia with grating including jointing to waste pipe fixed in cement concrete type B-1(1:2:4) complete all as specified and directed
S&F as in repair 10 litre capacity PVC valveless symphonic action type low level flushing cistern (ISI marked) including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified and directed by Engineer-in-charge Make:- Parryware Cat Part No "E8109 SLIMLINE ECONOMY", Hindware Cat Part No "509801", Cera Cat Part No "B1010112"
Taking up or down 15mm dia, steel tubing & connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
Taking up or down 20mm dia, steel tubing & connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
S&F 20 mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
Disconnecting existing PVC tanks, settisng aside (or lowering if required ) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position incl cleaning and removing all scale and dirt, etc from tanks and from mounths or circulating pipes etc of capacity exc 500 litres and n.exc 1000 liters.
S&F as in repair rotational moulded polyethylene water storage tank ISI Marked (cylindrical vertical three layered with closed top) hoisted and fixed in position of capacity 1000 litres including ball brass valve, high pressure with polythene float and flynut screwed for 20 mm dia GI pipe, 25mm bore GI washout pipe 15 cm long fitted with check nut, 20mm bore over flow pipe 1.50 metre long fitted with brass anti-mosquito nest coupling at the end of over flow pipe & 15mm bore GI air vent pipe 1.30 metre long fitted with tee at the end of air vent pipe (All GI pipes shall be medium grade) complete all as specified and directed by Engineer-in-Charge.
S&F as in repair rotational moulded polyethylene water storage tank ISI Marked (cylindrical vertical three layered with closed top) hoisted and fixed in position of capacity 2000 litres including ball brass valve, high pressure with polythene float and flynut screwed for 20 mm dia GI pipe, 25mm bore GI washout pipe 15 cm long fitted with check nut, 20mm bore over flow pipe 1.50 metre long fitted with brass anti-mosquito nest coupling at the end of over flow pipe & 15mm bore GI air vent pipe 1.30 metre long fitted with tee at the end of air vent pipe (All GI pipes shall be medium grade) complete all as specified and directed by Engineer-in-Charge.
S&F as in repair 15 mm bore bib tap, cast copper alloy, chromium plated, long body, fancy type with capston head and screwed down and screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge.. Make : Jaquar Cat part No "CON-CHR-107KN", Kohler Cat Part No "K-16093IN-4-CP", Marc Cat Part No "MSP-2080", GROHE Cat Part No "20238000"
S&F as in repair 15mm dia stop valve cast copper alloy, fancy type with, chromium plated long shank and cup (concealed type) with crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-charge. Make : Jaquar Cat Part No "LYR-CHR-38083K", Kohler Cat Part No "16087IN-4-CP", Marc Cat Part No " JHONSON Cat Part No "T3177C"
S&F as in repair fancy type pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shank & fly nuts, screwed suitable for iron pipes of 15mm bore complete all as specified and directed by Engineer-in-charge. Make : Jaquar Cat Part No "FON-CHR-40011", Kolher Cat Part No "K-26042IN-4-CP", JHONSON Cat Part No "T2601C5".
S&F as in repair vitreous china wash basin white flat back of size 600 x 480mm including a pair of angle iron brackets, PVC connection of size 450mm and 32mm dia waste pipe, 15mm dia fancy type, cast copper alloy chromium plated pillar tap with capastan head screwed down high pressure with long screwed shank and fly nuts, 32mm dia full threaded PTMT waste coupling including cutting for and pinning in ends of brackets and 32mm dia high density polythelene (HDPE) pipes for pressure rating 6 Kg/Sqcm with all fittings such as sockets, bends, tapers, etc complete all as specified and directed by Engineer-in-Charge. Make : Jaquar Cat Part No - "JDS-WHT-25901", Kohler Cat Part No - "K-5583IN-1WH-0"
S&F as in repair grating doom 100mm dia of PTMT (Minimum weight 25 gms) complete all as specified and directed
S&F as in repair waste pipe PVC low density polyethylene 32 mm dia complete all as specifed and directed.
S&F as in repair brass aluminium anodised tubular towel rail 20mm dia; 'D' type, 600mm long between flanges fixed to plug with chromium plated brass screws including wooden or plastic cleat complete all as specified and directed by Engineer-in-Charge.
S&F as in repair chromium plated Soap dish holder including chromium plated brass screws and plastic cleats complete all as specified & directed by Engineer-in-Charge
Dismantling of cast iron drain pipe of 100mm bore, jointed in CM and taking out from trenches complete all as specified and as directed by Engineer-in-charge. Note :- Excavation & earthwork shall be measured and paid separately
Dismantling of cast iron drain pipe of 75mm bore, jointed in CM and taking out from trenches complete all as specified and as directed by Engineer-in-charge. Note :- Excavation & earthwork shall be measured and paid separately
Demolition and breaking up 150 mm bore drain pipes (salt glazed stone ware, AC or reinforced concrete) including concrete bed and haunching and removing rubbish to a distance not exc 50m complete all as specified and as directed by Engineer-in-charge.
Supply and fixing PVC (SWR) bends any radius bore 110 mm complete all as specified and as directed by Engineer-in-charge.
S&F 100mm bore cast iron sand cast soil, waste and vent pipe in any length with or without ears fixed with cement joints fixed to walls complete all as specified & directed by Engineer-in-charge.
S&F 75mm bore cast iron sand cast soil, waste and vent pipe in any length with or without ears fixed with cement joints, fixed to walls complete all as specified & directed by Engineer-in-charge.
S&F 100mm bore cast iron sand cast soil, waste and vent pipe in any length with or without ears fixed with cement joints, laid in trenches or in floor complete all as specified & directed by Engineer-in-charge. Note :- Cost of Excavation & earthwork is deemed to included to in the unit rate of this items nothing extra shall be paid on this account.
S&F 75mm bore cast iron sand cast soil, waste and vent pipe in any length with or without ears fixed with cement joints, laid in trenches or in floor complete all as specified & directed by Engineer-in-charge. Note :- Cost of Excavation & earthwork is deemed to included to in the unit rate of this items nothing extra shall be paid on this account.
S&F as in repair 75mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified and as directed by Engineer-in-charge.
S&F as in repair 100mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified and as directed by Engineer-in-charge.
S&F as in repairs Cast iron 100mm bore branch pieces, single (equal or unqual), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors complete all as specified and as directed.
S&F Cast iron 75 mm bore branch pieces, single (equal or unqual), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) bends any radius jointed with adhesive with oval access door complete all as specified and as directed by Engineer-in-charge.
S&F 75 mm bore PVC (SWR) bends any radius jointed with adhesive with oval access door complete all as specified and as directed by Engineer-in-charge.
S&F 110mm bore PVC (SWR) pipes single socketed in any length jointed with adhesive fixed to walls fixed with and including requisite Number of clamps made out of flat iron 25x4mm complete all as specified and as directed by Engineer-in-charge.
S&F 75mm dia cast iron cowl fixed with cement joints complete all as specified and directed by Engr-in-Charge.
Supply only integral water proofing compound (ISI marked) complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old decorated, plastered or pointed surfaces of ceiling by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots etc and applying two coat of white wash complete all as specified & directed by Engineer-in-Charge.
M & L preparation of plastered or unplastered surface for applying two coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives @ 1.43 litre / 10 sqm over a coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed by Engineer - in - Charge .
M&L for preparation of old decorated, plastered or pointed surfaces of wall by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots, washing, rubbing down and stopping of distempered surface, filling of cracks etc and applying two coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives @ 1.43 litre / 10 sqm complete all as specified & directed by Engineer-in-Charge
M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Dismantling bricks (laid flat or on edge) or brick tiles on roof terrace, in floors, channels, kerbs, aprons etc laid dry or laid dry and pointed and removing from site complete all as specified & directed by Engineer-in-charge.
Cutting or uprooting grass on old mud phuska, removing rubbish off the premises, cleaning surface and preparing to receive new mud plaster
Demolition of mud phuska in roof any thickness including plastering & leeping (whether full thickness removed or only part thereof) complete all as specified and directed.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed
Demolition of PCC as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed
M&L for wire brushing and cleaning concrete surface on top of roof providing 15mm thick screed in cement mortar (1:4) with water proofing compound over and including 40mm thick cement concrete (1:2:4) type B0 (using 20mm graded crushed stone aggregate) complete all as specified and directed by Engineer-In-Charge.
M&L for APP based polymeric membrane minimum weighing 3 kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced aplication over and including applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m, including cleaning of surface complete all as specified and directed by Engineer-In-Charge
M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3
M& L fo formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick complete all as specified and directed.
S&F mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-charge.
M&L for cement concrete nominal mix of M-20 (20 mm graded aggregate) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specifed and as directed.
M&L for 300 mm thick average consolidated thickness, mud phuska on flat roofs including 25mm thick mud plaster and 3 mm thick leeping plaster complete all as specified and as directed by Engineer-in-charge.
M&L for 40mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on mud phuska complete all as specified and as directed
M&L for 900 mm wide, 75 mm thick 1:3:6 PCC type C1 finished even and smooth laid to slope of 1 in 20, laid in alternate bays, each bay not exceeding 2.5 m length withh joint to be 10 mm groove at junction of wall aand plinth protection filled with filled with bituminous sealing compound of grade A/ Bituminous Mastic filler/sealant,
S&F factory made steel ventilator with top hung shutter including hinges, steel peg stay, handle and cutting holes in brick wall built in cement mortar for inserting lugs and making good dismantled portion in cement mortor (1:3) or cement concrete (1:2:4) type B-I complete all as specified and directed by Engineer-in-charge.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft / loose soil complete all as specified and as directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil & getting out complete all as specified and directed by Engineer-in-Charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance exc 250 metre and not exc 500 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for cement concrete (1:3:6) type D2 (using 40mm graded crushed stone aggregate) as in foundations, fillings and mass concrete completed all as specified and as directed by Engineer-in-Charge.
S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 ®complete all as specified and directed by Engineer-In-Charge.
S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed by Engineer-in-Charge.
M & L for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
M&L including preparation of newely steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loose soil complete all as specified and as directed by Engineer-in-Charge.
M&L for Continuous brick edging; old size bricks with burnt clay bricks of sub class 'B' with width equal to the width of the brick; laid dry on end vertically complete all as specified and as directed by Engineer-in-Charge.
M&L for Hardcore of broken stone and boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface completed all as specified and as directed by Engineer-in-Charge.
M&L for 75 mm thick plain cement concrete (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and as directed by Engineer-in-Charge.
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 20mm thick screed bed or bedding of cement mortar (1:4) complete complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully or drawing out from conduit, existing copper / aluminium point wiring for light, fan, bell, socket, power point etc complete including fixture and fittings such as switches, sockets, ceiling rose, pendent holder, light fittings, top sheet covers, fan regulators, MCB, DB, lamp, earth plug etc (excluding MS sunken boxes) and making good the disturbed surfaces of wall/ceiling complete all as specified and as directed by Engineer-in-charge. Note : Taking down of serviceable fittings shall be measured and paid separately.
M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in and including new PVC rigid conduit medium grade 20mm dia and suitable fittings, fixed on surface of wall or concealed or above ceiling with accessories such as pipe hooks, elbows, junction box, terminated in existing sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 1.5 sqmm PVC insulated unshethed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point,exhaust fan point controlled by one switch complete all as specified and directed by Engineer-in- charge.
All as per serial item No. 114 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per serial item No. 114 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per serial item No. 114 here-in-before but for One light point controlled by two way switches.
All as per Srl item No. 114 above, but wiring with cable of cross sectional area 2.5 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 2.5 Sqmm PVC insulated multistandard unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F switch socket combination 5 pin, 5/15 Amps, 230 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F sheet metal plug & socket DB, SP, with a two pin and earth plug with socket, 230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge.
S&F switch piano flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F switch piano flush button 5 Amps single pole, two way complete all as specified and directed by Engineer-in-charge.
S&F switch socket combination 3 pin, 5 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 3/5 pin, 5 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F Lamp holder, insulated body with back plate etc complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge.
S&F as in repair flush mounting factory made SPN DB 8 way, 240 Volt, double door, IP-43 protection, IK-09 with metal door with 200 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge.
S&F as in repair MCB 63 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F as in repair MCB 32 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F as in repair MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F as in repair MCB 63 Amps, SP 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F as in repair flush mounting factory made TPN DB 4 way, 240 Volt, double door, IP-43 protection, IK-09 with metal door with 200 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge.
S&F as in repair MCB 100 Amps, TPN 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade top of pipe with funnel & wiremesh, and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 including taking down old eathing complete all as specified and directed by Engr-in-charge. Notes :- (i) Cost of GI wire upto 7.5m is included in this item. (ii) PCC 1:2:4, Excavation, earthwork is included in the quoted rate of this item. (iii) Cost of GI tubing upto 7.5m is included in the quoted rate of this item. (iv) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber. (v) Minimum weight of reinforcement for RCC cover shall be 1 KG.
S&F as in repair Energy efficient decorative ultra slim prewired 9 / 10watt (600mm length) LED light fitting (Mirror light) (Day cool light), surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser & integrated electronic driver and all accessories fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LUMILINEBS9WLED865S PCWH / Syska cat part No SSK-T5T-9W / Crompton cat part No LCTLN-10-CDL or equivalent cat part No of makes mentioned in Appendix 'A' here-in-after.
S&F as in repair Energy efficient decorative ultra slim, prewired, Maxoled batten for 18 watt retro lamp, ultra bright, glass shell, glare free, wide angle single/ double side connection retrofit LED tube with G-13 lamp holder/patti 20 watt LED light fitting (Day cool light) including 20 watt LED tube with all accessories prewired fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge.
Supply, fixing and testing as in repair LED Street / Security light fitting of 30 Watt, 5700K - 6500 K (including LED drive and internally prewired) complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminum alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with IP -65 / 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distortion THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second including 10 KV surge protection in built or external. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including connection for street light from pole box with 1.5 Sqmm, 3 core PVC insulated stranded copper conductor FRLSH cable, 1100 Volts grade ISI marked including addition / alteration in bracket (if required) for fixing light fitting complete all as specified and directed by Engineer-in- charge.
Notes for srl Item No 137 :- (a) Tenderer shall submit test report of LED street light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. Contractor shall obtain warranty from the manufacturer of product on their letter head and submit the same to deparment alonwith his letter head. The product will be replaced free of cost in the following case :- (i) Manfacturing defects (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include supply and fixing street light fittings on street light bracket fixed on poles, If street light fitting requires to fixed on existing street light bracket and any addition alterration required in bracket for fixing street light, In that case cost of additional / alteration is included in the unit rate of this item, which also includes needful T & P and required accessories such as 1.5 sqmm, 3 core PVC insulated stranded copper conductor cable for connection from pole box to light fitting etc complete including making connection, testing etc complete .No extra payment is admissible on this account. (e) Light fittings shall be provided with 10 KV surge protection as mentioned in description of item. If 10 KV surge protection is not provided in light fitting for which cat part is mentioned in BOQ. Contractor has to provide light fitting with 10 KV surge protection without any extra cost to department. (f) Contractor shall write CA No on street light fitting with synthetic enamel paint which should be visible from ground level. Cost of the same is included in the unit rate of this item nothing shall be extra paid on this account..
S&F as in repair street light bracket made out of 40mm dia GI pipe light grade 1.20m long , bent to shape at 120 degree angle from vertical fixed along pole with and dirlling holes including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint including any addition / alteration (if required) for fixing street light complete all as specified and as directed by Engineer-in-charge.
S&F in replacement Sub main wiring complete with 2 single core 4 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 4 Sqmm size cable as earth continuous wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 4 Sqmm single core cable and one run of 4 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 35 sq mm 2 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc including taking down old cable complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
S&F as in repair Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account..
S&F collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc, erected in position and securing runners with holdfasts and brackets and making good shall be done with a mix of mortar or concrete not leaner than cement mortar 1:2 or PCC 1:2:4 tybe B-1 complete all as specified and directed by Engineer-in-Charge.
S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, cooler stand 12mm sq guard bar, framework of water tanks and similar works of quality Fe 290 (Gde E-165) etc complete all as specified and directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, filling & mass concrete complete all as specified and directed by Engineer-in-charge .
M&L for 150mm bore salt glazed stone ware drain pipes of grade ‘A’, ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested complete all as specified and directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate in bedding to drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested complete for 150 mm bore pipe complete all as specified and directed by Engineer-in-charge.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
M&L for cement concrete (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement complete all as specified and directed by Engineer-in-charge. Note : Forming fair finished channel for drain using extra cement shall be measured and paid for separately.
M&L for precast reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in cover slabs of drains, manholes, septic tanks, soakage wells etc. including placing in position and set in CM (1:6) complete all as specified & as directed by Engineer-in-charge. Note: - Reinforcement shall be measured and paid for separately.
S&F mild steel TMT bars 6 to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-charge.
M&L for 10mm thick rendering in cement mortar (1:4) on fair faced or on other than fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
Material & labour construction of Soak Well for 51 to 100 users as shown on drawing No.GE(A) /comp / 17 / 2016 complete all as specified and as directed by Engineer-in-charge. Notes : Irrespective to whether shown on drawing or not, excavation & earthwork shall be in any type of soil, brick work shall be in CM 1:4, over burnt brick bats shall be used for filling, PCC 1:4:8 type D2 using 40mm graded stone aggregate shall be provided in foundation, 20mm dia MS rungs made to shape painted with two coats of bituminous paint shall be provided, PCC 1:3:6 type C2 using 40mm graded stone aggregate shall be provided in plinth protection, 1.50m long 150mm bore cast iron sand cast inlet pipe shall be provided and slab shall be Precast RCC (1:2:4). Other details shall be as shown on drawings & as specified in particular specifications.
M&L for construction of Septic Tank for 100 users as shown on drawing No. BTD-016 sheet No. 1/3 to 3/3 complete all as specified and as directed by Engineer-in-charge. Notes : Irrespective to whether shown on drawing or not, excavation & earthwork shall be in any type of soil, RCC in foundation shall be M-20 (Nominal Mix) over lean concrete (1:3:6) using 40mm graded stone aggregate over brick hard core, all PCC shall be M-20 (Nominal Mix) using 20mm graded stone aggregate, all RCC work shall be M-20 (Nominal Mix), brick work shall be in CM 1:4, 20mm dia MS rungs made to shape painted with two coats of bituminous paint shall be provided. Other details shall be as shown on drawings & as specified in particular specifications.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge. -------------------------------------------------------------------------- Note :- A sum of Rs. 98728/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 27 & 28 (Schedule of Credit) of Tender documents.
Gill Construction Co
M/S MANIRAM BISHNOI
BANSAL BROTHERS
PAREEK AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .