Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-AOC H NO 2086 UMRA TEH HANSI DISTT HISAR 125033 | HANSI | HISAR | HARYANA | 125033 | L1 | Accepted-AOC due to lower rates |
Tender Value
₹2.2 L
EMD Value
₹5,000
Closing Date
27 Dec 2019, 5:00 pmClosed
Executive Engineer
Executive Engineer Provincial Division PWD BandR Branch Faridabad
Special repair for renovation of High Dependency Unit in existing B.K. Hospital at Faridabad REINVITED
2019_HRY_113357_1
9375-9424
Open Tender
Civil Works - Buildings
Works
60 days
NIT Faridabad District Faridabad
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Executive Engineer Provincial Division PWD BandR
₹5,000
12 Aug 2021
20 Dec 2019
31 Dec 2019
20 Dec 2019
27 Dec 2019
20 Dec 2019
Amount
Special Repair for renovation of High Dispensary Unit in existing B.K. Hospital at Faridabad [RE-INVITED]
Dismantling Brick Work, Tile Masonry or Tile Lining and Tile Terracing in cement [HSR 8.5b]
Removing door and windows (wood and steel) with chowkats by making Recesses in walls when the wall is not to be dismantled doors:-[HSR 8.18a]
Removing door and windows (wood and steel) with chowkats by making Recesses in walls when the wall is not to be dismantled windows:-[HSR 8.18b]
Scraping white wash & colour wash [HSR 8.32a]
Scraping cement plaster. [HSR 8.32c]
Dismantling white or coloured glazed tiles (to be carefylly removed) [HSR 8.38]
Providing & Fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. The tiles should have Humidity Resistance. (RH) of 99%, Light Reflectance 285%, Thermal Conductivity K-0.052-0.057 w/m K,Fire Performance ance as per (BS 476 pt-6& 7) in true horizontal level suspended on interlocking TGrid of hot dipped all round galvanized iron section of0.33 mm thick (galvanized@ 120 gsm) comprising ofmain T runners of 15x32 mm of length 3000 mm, cross T ofsize 15x32mm oflength 1200 mm and secondary intermediate cross T of size 15x32mm oflength 600 mm to form grid module of size 600×600 mm suspended from ceiling using galvanized mild steel item (galvanised @ 80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2mm, spaced at 1200 mm centre to centre along main •T'. The system should rest on periphery walls/partitions with the help of GI perimeter wall angle of size 24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with helop of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S.screws. The exposed bottom portion of all Tsections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights.i The work shall be carried out as per specifications, draw ings and as per directions of the Engineer-In-Charge. With or without groves. [HSR 13.92]
Painting two coats with synthetic enamel Paint in all shades on old wood-work or metallic or plastered or concrete surfaces to give an even shade including rubbing down old paint. [HSR16.5]
Proving & fixing aluminum works for doors, windows, ventilators & partition with extruded built up std. tubular sections / appropriate Z section and other sections of approved make conforming to IS: 733 and IS :1285 fixed with raw plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required neoprene felt etc. aluminum sections shall be smooth, rust free straight mitered and jointed mechanically wherever required including cleat angle aluminum snap beading for glazing / panclling C.P. brass / stainless steel screws, all complete. Fixed portion (Anodized aluminum transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15). [HSR 17.95]
Providing & fixing aluminum work for door & window, ventilators and partition with extruded built up standard tubular section / appropriate Z section and other section of approved make conforming to IS, 733 and IS : 1285 fixed with raw plugs and screws or with fixing clips or with expansion hold fastener including necessary filling up of gap at junction, at top, bottom & side with required neoprene felt etc. aluminum section shall be smooth, rust free straight mitered and jointed mechanically wherever required including cleat angle. Aluminum snap beading for glazing/paneling CP brass/stainless steel screw, etc. complete. Shutter of door, window & ventilators including providing & fixing hinges/ pivots and making provision for fixing of fitting wherever required including the cost of PVC/neo preme gasket required including aluminum fitting [HSR 17.96]
Providing & fixing glazing in aluminum door, window, ventilator, shutters & partitions etc. with PVC/Neo preme gasket etc. complete (cost of aluminium snap beading shall be paid in basic item) with fo [HSR 17.98b]
Providing aluminum jali of thickness 7 mm thick with opening 75 x 75 mm of inclduing anodizing and fixing in frame with cost of screws etc. complete. [HSR 17.100]
Providing, Laying and fixing ceramic/ vitrified tile / of any size of approved make in floors/dados, laid in any pattern as specified over base of 3 mm thick adhesive of reputed brands such as Pidilite, Laticrete, Ferrouscrete & Valendure as per IS specification 15477-2004 using 5 Kg. adhesive per Sqm area of tiles and jointed with cement slurry mixed with pigment to match the shade of tiles. [NS item].
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .