Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.3 CrAccepted-AOC NO 167 1 MUTHUGOUNDENPALAYAM RING ROAD KUMARAPALAYAM ERODE 638 104 | ERODE | TAMIL NADU | 638104 | ₹40.3 Cr Quoted ₹42.1 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹42.6 CrRejected-AOC NO 93 KADAL THOTTAM VADAPALANI KUMARAPALAYAM POST NATHAKADAIYUR VIA ERODE 638 108 | ERODE | TAMIL NADU | 638108 | ₹42.6 Cr | L2 | Rejected-AOC Other than lowest bidder |
| 3 | L3₹42.9 CrRejected-AOC NO 5 2 28B RAMAN NAGAR SALEM MAIN ROAD METTUR DAM SALEM DISTRICT 636 403 | SALEM | TAMIL NADU | 636403 | ₹42.9 Cr | L3 | Rejected-AOC Highest bidder |
| Sl No | Description | Qty | Unit | kadal constructions L2 | Rajam Engineering Contractors L3 | BLUELEAF PROJECTS PRIVATE LIMITED L1 |
|---|---|---|---|---|---|---|
| 1.00Civil Works | ||||||
| 1.01 | Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. | 5,106 | Cum | 285 ₹17.2 L | 280 ₹16.9 L | 270 ₹16.3 L |
| 2.00 | Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification | 1,702 | Cum | 165 ₹3.3 L | 180 ₹3.6 L | 170 ₹3.4 L |
| 3.00 | Supplying and filling in foundation & basement with Stone Dust in layers of not more than 15cm.thick well rammed watered and consolidated complete complying with standard specification. | 870 | Cum | 405 ₹4.2 L | 400 ₹4.1 L | 380 ₹3.9 L |
| 4.00 | Supplying and filling in foundation & basement with M-sand in layers of not more than 15cm.thick well rammed watered and consolidated complete complying with standard specification. | 760 | Cum | 2,015 ₹18.1 L | 1,900 ₹17.0 L | 2,000 ₹17.9 L |
| 5.00 | Supplying and filling in foundation & basement with Gravel in layers of not more than 15cm.thick well rammed watered and consolidated complete complying with standard specification. | 870 | Cum | 555 ₹5.7 L | 600 ₹6.2 L | 550 ₹5.6 L |
| 6.00 | Cement concrete 1:5:10 (One Cement, five sand and Ten hard broken stone jelly) using 40mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not mote than 15cm thick, well rammed, consolidated and curing etc. complete complying with standard specification. | 507 | Cum | 6,135 ₹36.7 L | 6,050 ₹36.2 L | 6,300 ₹37.7 L |
| 7.00 | Damp proof course with Cement Mortar 1:4 (One Cement and Four sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used and finishing, curing etc. complete complying with standard specification. | 135 | Sqm | 345 ₹54,958.50 | 340 ₹54,162 | 300 ₹47,790 |
| 8.00 | Supplying and erecting steel centering including necessary supports for plane surfaces in foundation and basement for reinforced cement concrete works such as column footing, plinth beam, grade beam, stair case step, bed block etc. which require only normal strutting using M.S. sheets of size 90cmx60cm BG 10 gauge of stiffened and welded with mild steel angles of size 25mmx25mmx3mm for boarding laid over silver oak joists of size 10cm x6.50cm spaced at about 90cm centre to centre and supported by the casurina props of 10cm to 13cm dia spaced at 75cm centre to centre at suitable intervals etc. complying with standard specification. (The payment for centering shall be made only after the concrete is laid). | 2,195 | Sqm | 815 ₹21.1 L | 800 ₹20.7 L | 900 ₹23.3 L |
| 9.00 | Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting upto 4.90m to 5.50m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). | 5,430 | Sqm | 1,250 ₹80.1 L | 1,250 ₹80.1 L | 1,300 ₹83.3 L |
Tender Value
₹40.3 Cr
EMD Value
₹40.3 L
Closing Date
6 Feb 2026, 3:00 pmClosed
Superintending Engineer
O/o Superintending Engineer, PWD, Heritage Buildings Circle, Chepauk, Chennai -05
CONSTRUCTION OF A BRONZE GALLERY WITH TRADITIONAL ARCHITECTURAL DESIGN WITHIN THE EGMORE MUSEUM COMPLEX
2026_PWD_649677_1
85/HBC/2025-26
Open Tender
Civil Works - Buildings
455 days
Chennai
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹40.3 L
5 Mar 2026
31 Jan 2026
6 Feb 2026
31 Jan 2026
6 Feb 2026
31 Jan 2026
Civil Works
Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
Supplying and filling in foundation & basement with Stone Dust in layers of not more than 15cm.thick well rammed watered and consolidated complete complying with standard specification.
Supplying and filling in foundation & basement with M-sand in layers of not more than 15cm.thick well rammed watered and consolidated complete complying with standard specification.
Supplying and filling in foundation & basement with Gravel in layers of not more than 15cm.thick well rammed watered and consolidated complete complying with standard specification.
Cement concrete 1:5:10 (One Cement, five sand and Ten hard broken stone jelly) using 40mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not mote than 15cm thick, well rammed, consolidated and curing etc. complete complying with standard specification.
Damp proof course with Cement Mortar 1:4 (One Cement and Four sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used and finishing, curing etc. complete complying with standard specification.
Supplying and erecting steel centering including necessary supports for plane surfaces in foundation and basement for reinforced cement concrete works such as column footing, plinth beam, grade beam, stair case step, bed block etc. which require only normal strutting using M.S. sheets of size 90cmx60cm BG 10 gauge of stiffened and welded with mild steel angles of size 25mmx25mmx3mm for boarding laid over silver oak joists of size 10cm x6.50cm spaced at about 90cm centre to centre and supported by the casurina props of 10cm to 13cm dia spaced at 75cm centre to centre at suitable intervals etc. complying with standard specification. (The payment for centering shall be made only after the concrete is laid).
Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting upto 4.90m to 5.50m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting Centering for curved RCC Beam surfaces above 3.60m to up to 4.90m height etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60 to 4.90 m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
For circular columns
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kg/mᶾ and maximum water cement ratio of 0.45, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
For Foundation and Basement.
For Ground Floor.
For First Floor.
For Second Floor.
Providing and laying in position, Standardised Concrete Mix M-35 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kg/mᶾ and maximum water cement ratio of 0.45, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
For Second Floor .
Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials)
For Foundation and Basement.
Supplying, fabricating and placing in position Mild steel or Ribbed Tor steel rods for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 6313 Part I to IV in stages to suit the progress of work consist as per the detailed specification as below. (Measurements taken for the plinth area for the purpose of payment) including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing, etc., complete and as directed by the departmental officers. (The chemical should be got approved by Executive Engineer before use on work).
Stage-1: Spraying anti-termite chemical solution for the foundation before laying concrete, in bottom and sides of foundation.
Stage-2: Spraying anti-termite chemical solution to the grade beam level, spraying has to done for the grade beam, brick masonry contact with the back fill earth.
Stage-3: Spraying anti-termite chemical solution on the sand for the flooring before laying the flooring concrete. This treatment has to be carried out on the sand filling by making holes with crow bar to a depth of 60cms and at 60cms intervals on both direction and at junction of wall and flooring thoroughout.
Stage-4: Spraying anti-termite chemical solution alround building outside by making holes through bar before laying plinth protection and the holes to be closed after the treatment.
Brick work in Cement Mortar 1:6 (One cement and Six sand) using best quality of II class Ground moulded chamber burnt bricks of size 9" x 4 3/8" x 2 3/4" for superstructure including curing, etc., complete complying with standard specifiction.
For Foundation and Basement.
For Ground Floor.
For First Floor.
For Second Floor.
Exposed Brickwork in cement mortar 1:3 with waterproofing compound for the external wall using best quality of wirecut bricks for heritage works 9"x4"x3" for all the external walls pilasters above the natural ground level, including curing,etc., complete complying with standard specification and as directed by the Departmental Officers.
For Ground Floor.
For First Floor.
Lime Concrete 1:2:5 (One lime, two sand and five brick jelly) using 40mm gauge brick jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor finish, curing etc. complete complying with standard specification. (For flooring in toilet partions except water closet portions).
Providing,mixing,laying polymer based water proofing treatment for the sunken toilet by applying cement based,flexible,water proofing compound confirming to IS 2645, to a thickness of 1mm of the prepared surface of the roof slab/floor slab as per the specification mentioned above providing cement mortar1:3,water proofing cover plaster toa thickness of12mm over the membrane coating with administrative of approved make .Rate quated inclusive of preparation of surface which includes cleaning of surface polymer mortar curing labour tools and equipments etc Rate inclusive of cement,sand required for the treatment,the cost and labours for fixing 25mm dia pressure pipes 15kg/cm2 to alengthof 45cm for drip pipes etc complete.
Paving the floor with best quality Heritage pattern Cement tile of Bharat tiles brand of size 254 x 254 mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The design of the tiles should be got approved by the Architect before use on works)
Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Jet Black with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Dadooing the walls with best approved quality with printed design colour glazed tiles of size 300mm x 450mm x 8mm set in Cement Mortar 1:2 (One Cement and Two sand) 10 mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg./Sq.M. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) the proportion of brick jelly to lime being 32:12-1/2 by volume and laid over the RCC roof slab in a single layer of required design, slope and finished thickness by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
Finishing the top of roof with one course of machine pressed tiles of size 230 mm x 230 mm x 18 mm of apporved quality in Cement Mortar 1:3 (One cement and three sand) 12 mm thick mixed with water proofing compound conforming to IS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers.
Providing and Fixing Pelmet on the walls as per drawings and specification. Pelmet to be made using 12mm water and termite proof plywood cut and made into desired shape and size and fixed on to the wall on aluminum frame work, and finished using Interior emulsion, colour and finish as specified by the architect/engineer in charge.
Finishing the top of slopped roof, sun-shade with Mangalore Tiles of approved quality laid in cement mortar 1:3 20mm thick mixed with WPC at 2% by weight of cement used and top pointed with the same red oxide mixed mortar etc complete, Rates including the Teak Wood Reepers 50x25mm and Wooden Eaves Board as design complying with standard specifications
Providing and Fixing of Precast terracotta balustrade spaced at 300mm c/c between 230 mm high brickwork above and below the balustrade and Plastering with Cement Mortar 1:5 (One cement and five sand),12mm thick top and bottom of precast jally and as per drwgs and specification, The rate inclusive of all materials, labour power and conveyance of materials to the work site, loading & unloading etc., and as per drawing and design by the Departmetnal Officers and All the materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Art Plaster: using 1:3 Cement Mortar and finishing it with fine mortar using brick masonry set in 1:0.5: 3 cement mortar, plastered with 1:3 CM finished with 1:2 fine ground CM. for columns and fanlights
Providing plinth protection with a bed of 100 mm thick PCC (1:5:10) using 40 mm size Granite and on bed of PCC - Granolithic concrete flooring 40 mm thick using 6 mm to 12 mm size hard granite machine crushed metal laid over CC bed already laid, in alternative panels of size not exceeding 1.5 x 1.5 Mts. And finishing the top surface to required smoothness and slopes including grooves, thread lining as directed by the Engineer-in-charge including cast and conveyance of all materials to size including seigniorage charges, sales & other taxes on all materials and operational & incidental and labour charges like mixing of cement concrete, laying, curing, lift charges etc., and Overheads & Contractors profit complete including cost of CC bed for finished item of work.
Providing Cornices with moulding, decorative bands using cement mortar (1:3 Cement Mortar and finishing it with fine mortar using brick masonry set in 1:0.5: 3 Cement mortar, plastered with 1:3 CM finished with 1:2 fine ground CM) including inserting brick pieces, making templates to match the original work etc complete up to 450 mm thick/wide
Providing and Fixing false rafters on the RCC ceiling as per drwgs and specification. False rafter to be made using 12 mm water and termite proof plywood cut and made into desired shape and size and fitted with teak wood veneer, and fixed onto the ceiling using screws. and finished using French polish, colour and finish as specified by the architect/engineer in charge.
Supplying and fixing in position best approved of ISI quality PVC rain water down fall pipes of differnet dia having a pressure of 4 Kg./Sq.cm including cost of necessry PVC shoe, PVC bend, gratings of required diameter and special clamps, brass screws, nails, etc. The rate is to include cost of removable iron grating of appropriate size the size of teak wood plug to be used is 150 x 25 mm in front and 200 x 75 mm in rear (wall side) with a depth of 100 mm. The pipe is to be fixed by means of 'U' clamps ad screwed to the plugs to the type of 'U' clamps at the centre of the pipe to be fixed and as directed by the departmental officers.
110mm dia PVC pipe
160mm dia PVC pipe
Teakwood wrought & putup for joist, beam, rafters and purlins,etc., which are in full length new member placed for supporting the Madras Terrace roof/ Mangalore tiles roof or any other area in all floor as directed by the departmental officers by using well seasoned superior quality and approved variety of teakwood for heritage building work including fixing of iron holdfasts incase of doors, windows and ventilators etc.,and excluding cost of holdfasts and making necessary size holes in the masonry to receive the ends of wooden joists, beams, etc., all fixtures and fastenings etc., complete. Item to include all moulding and chamber to be made as per original design indicated by the Engineer In Charge. (The rate includes the cost of teakwood, labour charges for wrought and putup to the existing clue/design, fixing in position to true alignment and gradient wherever necessary. Complying with standard specifications and as directed by the departmental officers (sample of teakwood to be shown to the Executive Engineer concerned for approval before use on work). Application of Solignum on the wooden surface should also be done. In all floors
Supplying and fixing of Teak wood panelled door with door frame shutter two leaves shutter of size 0.70x3.00 using Teak wood scantling of thickness of 0.04m alround and centere and the panels should be covered with 12mm thick Teak wood planks and the shutter and door frame thickness 0.10m x 0.12m should be fixed in position with necessary furniture fitting such as 6-Nos cost of brass butt hinges 6” long, 4-Nos brass tower bolt 3”-00”, brass aldrop 10” with necessary screws and nails and painting the door shutter with one of primer etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing fully glazed shutters for windows openable type by using well seasoned teakwood of superior quality as per the original design and pattern instructed by the Engineer In Charge. The window shutter is made of vertical styles of size 80mm x 30mm. Both top and bottom rail is of size 80mm x 30mm. The window shutter panels is covered with 4mm thick plain glass which is fixed with teakwood reepers scantling of size 35mm x 30mm on both sides and the glass panel is divided into 6 parts. Item to also include making all the mouldings and design of the panels as in the existing evidence. Item to include complete finishing of the shutters as directed by the departmental officers.(The rate inclusive of cost of all teakwood materials, labour wrought and putup of door shutters, cost of all furniture fittings, cost of 4mm thick plain glass, labour charges for fixing the shutters in position etc., complete complying with standard specifications)
Supplying the damaged teak wood ornamental hand rail in stair case and verandha portion with superior quality of teak wood and kadasal work in all the members, the top member of size 8 x 6 cm with curved surface, in bottom member of size 10 x 8 cm, the internal vertical supports are 6.5 x 6.5 cm, the internal bracing and design members of side with 2.50 x 2.50 cm with complete kadasal works, the rate inclusive of cost teak wood, skilled labour charges, necessary screws, nails, etc., complete complying with standard specification as directed by the departmental officers.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work.
Supplying and fixing MS grills for doors, windows and ventilators of approved design and as directed by the departmental officers including cost of MS grills labour charges and cost of one of red oxide primer coat etc., complete complying with std. specification.
Special ceiling plastering and finishing the exposed surface of RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc. with Cement Mortar 1:3 (One Cement and Three Sand) 10 mm thick including hacking the surfaces and providing Cement Mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc. in all floors complying with standard specification as directed by the departmental officers
Plastering with cement mortar 1:5 (One cement and five sand) 12mm thick in all floors including finishing neatly curing etc. complete complying with standard specification.
White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed.
Painting walls with two coats of Plastic emulsion paint use primer in all floors using best freshlyl burnt white shell lime and best quality approved variety of colouring pigments, fevical type gum, brushes, scaffolding charges etc. complete complying with standard specification. Mineral colouring pigments not affected by lime should only be used (Stainers and colour solutions should not be used).
Painting the wall with two coats of Texture Finish Paint including labour charges of cement plastered wall surface ect., complete complying with standard specification.
Polishing the teak wood door with two coats of best French (Lac) polish with approved quality and brand over a coat of bee's waxing including preparing the wooden surface to receive polishing, etc., complete complying as per the standard specifications. (The make, quality and colour of french polish, bees vax should be got approved by the Executive Engineer before use on works.)
Varnishing the new wood work with two coats of best melamine varnish of approved quality and brand including preparation of surface etc.. The rate is inclusive the cost of all material, labour charges and finishing neatly etc., complete compluing with standard specification and as directed by the departmental officers.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Supplying and installation of Anutone / Woodfit / Saint Gobian / Equivalent Brand of Acoustic Fabric Wall Panelling of stretch fabric NRC wall fabric system by using FR Grade NRC fabric of size 1400mm width shall be stretched by using CC 25 with infill of synth pf polywool 10 X 25 mm thick, rigid vinyl stretch tracks half wrap / full wrap 15mm (FS15) and midseam 15mm (FS15), strand board, synth PF infill with requisite accessories & tools. CC 50mm is first installed on the wall along with the marking lines with metal fasteners inserted at 300mm centers. FS15 tracks to be installed on wooden base, after applying stick S7 adhesive on both surfaces for a true and continuous secure grip, and heavyduty fasteners at 150mm centers on one / both sides of stretch tracks. Strand square edge magnesite bonded pinewood fiber panels of size 600 x 2400 x 20mm having density 400 kg / m3, weight 4 kg which is fixed to wall with suitable fasteners. Sound synth PF polywool 10 x 25mm thick adhered on strand panel by using Stick 7 adhesive. Fabric of width 1400mm is then aligned to the stretch tracks by following the fabric thread line or pattern. The fabric is stretched and tucked into the stretch tracks and secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools. The systems to achieve noise reduction coefficient not less than 0.85 NRC, so as to have an neat appearance as directed by the department offices. The cost includes, cost of material, cost of labour, scaffolding, transportation, conveyance, etc., complying to standard specication. (AV room)
Post Tensioning Work: Design and execution of post tensioning work, including decoiling, the strands, cutting to the required lengths, supplying, laying of HT strands sheathing (GI corrugated ducts 0.3mm thick) jointing with couplers and inserting the strands, profiling, fixing liveend anchorages, including supply of stressing anchorages, suitable for 5-5 & 5-4 tendons, grout vents, making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of antibursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures with required tools, plants, and machineries, and consumables etc. (Shuttering, concreting & reinforcement steel shall be paid under respective items) at all heights including all leads, lifts, coordination, with the post- tensioning agency, preparation of drawings, obtaining approval from the Employer / Architect etc. Rate to include providing water, power, cement and admixture for grouting, packing of sheathing and anchorages blockings, filling of recess pockets after stressing using grouts (cement slurry mixed with approved admixtures) including providing access to post tensioning at all heights including all leads, lifts etc., all complete and as approved and as directed by the Employer Architect but excluding shuttering, concreting & reinforcement steel which shall be payable under respective items separately.
HARDWARE & ACCESSORIES • Top rail is made of stainless steel grade 304. There are two options for the top rail. First one comes with a rectangular cross section (Size to be 55mmx42mmx1.6 mm) and the other one comes with circular cross section (Diameter 32 mm). Surface finish will be brush type. A thin plastic film is pasted for surface protection. • Corner joinery section made from Stainless steel grade 304. Surface finish to be brush type. A thin plastic film pasted for surface protection. Size to be 35mm x16.4mm x 0.8 mm. • Wall joinery section with hamming profile made from Stainless steel grade 304. Surface finish to be brush type. A thin plastic film is pasted for surface protection. Size to be 21mm x 16mm x 0.8 mm. • Adjustable Pedestal Footing of base diameter 60 mm made from Stainless steel grade 316 giving an adjustable height of 100mm to 150mm. Surface finish to be matt type. • Spring loaded Butt Hinges made from Stainless steel grade 304. Surface finish to be matt type. Covers to be lacquer coated. • Coat hook with rubber stopper made from Stainless steel grade 304. Surface finish to be lacquer type. • Round Door knob diameter 30 mm with grooves for better hand grip made from Stainless steel grade 304. Surface finish to be matt type. • Rotating Thumb-turn locking system with privacy indicator made from Stainless steel grade 304. Surface finish to be lacquer type. • Anti-noise rubber padding of thickness 2 mm and width 10 mm
Supplying and fixingTitan Std Series Cubicles: Approx Sizes (W x D x H) 1000mm x 1550mm x 2100mm (Height is including 150mm gap from bottom) Door Size- 610 mm complete complying with standard specification and as directed by the departmental officers.
Supplying and fixingTitan Std Series Cubicles: Approx Sizes (W x D x H) 1500mm x 2100mm x 2100mm (Height is including 150mm gap from bottom) Door Size- 610 mm complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing Napkin destroyer with digital display model SM-20 wall mounting type including fixing the same in position with necessary screws, nails including labour charges for fixing in position etc., complete complying with standard specification and as directed by the departmental officers.
Nosing to the granite Slab by Cutting the granite slabs for 18mm to 20mm thick edges semicircular shape to required size and pollishing using hand machine and the nosing is made highlyh smooth and glossy. The cost includes labour charges and cost of machiniries and polishing charges etc. complete as directed by the Departmental Officers.
Construction of Inspection chamber or manhole of the following size including necessary earth work excavation in all soils to full depth as may be directed with sand filling at bottom of the chamber for 10cm thick, concreting CC 1:5:10 using 40 mm guage HBGs jelly 10 cm thick and sode walls 9" thick brick work in cement mortar 1:5 using Fly ash bricks filling the size of foundation with excavated earth, plastering with cm 1:3 20m thick for inside and bottom and making necessary benching with brick jelly cement concrete to the required slope and finishing neatly etc., complete.
Inspection Chamber of Size 0.90X0.90X1.80M
Inspection Chamber of Size 0.60X0.60X0.90M
Providing RCC pre-cast slab with 75mm thick in cement concrete 1:2:4 (one of cement two of sand and four of aggregate) using 20mm thick hard broken stone jelly and river sand including the cost of reinforcements grills and fabrication charges, moulding, curing finishing charges and fixing inposition nearly etc complete complying with standard specification and as direvted by the departmental officers.
Internal Water supply arrangements.
Supplying, laying and jointing UPVC Pipe (Un-Plasticized Polyvinyl Chloride) (Schedule-80) of approved quality and best variety conforming to BIS of the following dia including cutting, and fixing UPVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The UPVC Pipe (Un-Plasticized Polyvinyl Chloride)shall be got approved by Executive Engineer before use on
ABOVE GROUND LEVEL/Below ground level
15mm dia
20mm dia
25 mm dia
32mm dia
40mm dia
50mm dia
Supplying, laying and jointing UPVC Pipe (Un-Plasticized Polyvinyl Chloride) (Schedule-80) of approved quality and best variety conforming to BIS of the following dia including cutting, and fixing UPVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The UPVC Pipe (Un-Plasticized Polyvinyl Chloride)shall be got approved by Executive Engineer before use on
BELOW GROUND LEVEL
20mm dia
25mm dia
32mm dia
40mm dia
50mm dia
Supplying and fixing in position UPVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
Coupler
Elbow
Reducer
20 mm x 15 mm
25 mm x 20 mm
32 mm x 25 mm
40 mm x 32 mm
50 mm x 40 mm
Reducer Tee
20 mm x 15 mm
25 mm x 20 mm
32 mm x 25 mm
40 mm x 32 mm
50 mm x 40 mm
Reducer Elbow
20 mm x 15 mm
25 mm x 20 mm
32 mm x 25 mm
40 mm x 32 mm
50 mm x 40 mm
Hex Nipple
25 mm Dia
32 mm Dia
40 mm Dia
50 mm Dia
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
Fixing Gun Metal Gate Valve
Supplying and fixing in UPVC unions of heavy duty of approved quality and good variety of various sizes (The UPVC unions should be got approved by Engineer before use on works).
Supplying and fixing in position 15mm dia brass CP Brass BIB tap Jaquar or Equivalent (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
Supplying and fixing in position 15mm dia brass CP Brass Stop cock Jaquar or Equivalent (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand of size 600 x 450 mm shelf type with necessary plywood backing rubber buttons brass chromium plated screws, plugs etc. complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks)
Supplying and fixing in position best and approved quality chromium plated brass Towel Rail of 600mm length and with 20mm dia CP brackets of same materials including cost of TW plugs chromium plated brass screw etc. complete complying with standard specification.
Supplying and fixing in position best approved quality C.P. Brass Soap Tray of size 150 x 100 mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing in position best quality and approved make Indian made star white earthernware Vitreous wash hand basin of size 550 x 400mm (with pedestal ) Jaquar or Equivalent with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
Supplying and fixing Indian Water Closet (Oriya type) of size 580 x 440 mm white glazed earthern ware of approved quality with "P" or "S" trap conforming to IS 2556 part 12 with sand cushion and forming flooring alround the closet using 40 mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) using 40 mm broken brick jelly and finishing the top to required slope fixing in position and including giving necessary connection to 600mm lenght of 110mm dia PVC Soil pipe stacks(by dismantling masonry, RCC roof slaps and making good, the sisturbed portion to original condition without any leakage etc. complete as directed by the departmental officers and complying with standard specification. The cost is inclusive of 600mm PVC pipe of 110mm dia, sand filling for 0.45 cu.m, lime concrete 1:2:5 using 40mm brick jelly for 0.11 cu.m. (The water closet P or S trap are to be got approved by the Executive Engineer before use on works).
Supplying and fixing in position white / colour glazed European Water Closet wall mounted of best quality of Jaquar or equivalent with consealed flushing tank and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings.....
such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works)
Supply and fixing in position of best Indian make white / colour vitreous glazed earthernware lipped mouth flat back urinal with inbuilt auto flush system with Stainless steel bracket of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.)
Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
Nahani Trap of size 100 x 75mm with stainless steel gratings
Nahani Trap of size 75 x 50mm with stainless steel gratings
Supplying and fixing in position 150x100mm square mouth P or S trap stone ware gully trap with cast iron grattings of size 150x150mm with c.I air tight cover with necessary earthwork excavation, laid over a bed of brick jelly cement concrete 1:3:6, 150mm thick using 40mm size brick jelly including necessary brick work and plastering and giving connection to soil pipe etc., complete.
Supplying and fixing in position best quality PVC soil waste pipes of various size having ISI mark and pressure of 6 Kg/Sq.cm providing leak proof joints with PVC adhesive etc. including fixing to the walls with necessary T.W. plugs, brass screws mild steel clamps etc. and giving connection to the sanitary fittings including dismantling brick masonry /RCC works / roof slab etc. wherever necessary and making good the dismantled portion to the original condition, complying with standard specifications etc. complete (The PVC pipe should be got approved by the Departmental Officer before use on works).
110 mm dia PVC Pipe
75 mm dia PVC Pipe
Supplying and Fixing in position of the following PVC specials best approved quality conforming to ISS and providing leak proof joints with PVC adhesive etc., including fixing to wall with necessary teak wood plugs screws etc. such as plain bend, door bend, plain tee, door tee, offsets, Y-Junction, Plain or with door of various sizes best quality confirming to ISS and providing leak proof joint including fixing to wall and giving connection to the PVC soil stacks, dismantling the brick masonry or RCC floor of roof slab and redoing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved from the Executive Engineer before use on works).
PVC Elbow
110mm dia
75mm dia
PVC Elbow with Door
110mm dia
75mm dia
PVC Tee
110mm dia
75mm dia
PVC Tee with Single Door
110mm dia
75mm dia
PVC Tee with Double Door
110mm dia
75mm dia
PVC Bend
110mm dia
75mm dia
110mm dia
75mm dia
PVC "Y" with Single Door
110mm dia
75mm dia
PVC "Y" with Double Door
110mm dia
75mm dia
Supplying and fixing in position PVC 4 way junction plain or with door of various dia of best approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
PVC Double Tee with Single Door (4 way junction)
110 mm dia
75 mm dia
PVC Double Tee with Single Door (4 way junction)
110 mm dia
75 mm dia
Supplying and fixing in position PVC cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications. (The PVC cowl should be got approved by the Executive Engineer before use on works).
110 mm dia
75 mm dia
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 10 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
PVC Pipe 225mm dia 10 kg. / sq.cm
Providing , laying, spreading and compacting graded stone aggregates for Wet Mix Macadam 250mm thick, including premixing the materials with water at OMC in machanical mix plant, conveyaance of mixed materials by tipper to site, laying in uniform layers using pavers in sub base/ base course on well prepared surface and compacting with vibratory roller to acheive the desired density including cost of material, labour charges, rentals of machinery, fuel and all other incidental charges etc complete as per clause 406 of MORTH Rev-5
Supplying and laying of Inter Locking Paver Block stone 83mm thick over a base layer of sand filling including cost of materials laying and labour charges etc complete complying with standard specification and as directed by the departmental officers.
Drilling borewells any where in Tamilnadu including transportation from one place to another place within tamilnadu in alluvial soil or sedimentary strata of clay and sand or sandstone, shale, pebbles, boulders etc., by First taking pilot bore hole of 140/150/200mm dia and then enlarging to required dia by direct or reverse rotary muds circulation method using contractor's rig, fuel, labour for driling, bentonite mud and water required for drilling at the site shown by the departmental Officers including construction of mud pit only calyx drills are to be used. etc.60m to 90m
Reaming from 140/150mm dia pilot bore to 300mm dia bore as directed by the departmental officers.etc 60 m to 90 m
Charges for developing the borewell with air compressor of 300 cfm capacity (Minimum 8 hours) including transportation, labour and fuel charges for compressor as directed by the dept. officers etc. complete
Supplying PVC casing pipes of following dia of best and approved quality with or without slot for bore well as approved by the departmental officers etc. complete
140 mm dia Slotted pipe
140 mm dia Plain pipe
Supplying and fixing of PVC end cap of 140 mm dia for bore well as directed by the departemental officers.
Labour charges for inserting PVC casing pipe 140 mm assembly in the drilled bore hole including jointing the pipes with PVC couplers and charges for packing the annular space with pebbles etc. complete as directed by the departmental officers etc.
Supplying, laying and jointing UPVC Pipe (Un-Plasticized Polyvinyl Chloride) (Schedule-80) of approved quality and best variety conforming to BIS of the following dia including cutting, and fixing UPVC specials using PVC adhesives inserting the bore well etc., complete complying with standard specifications. The UPVC Pipe (Un-Plasticized Polyvinyl Chloride)shall be got approved by Executive Engineer before use on work)
32 mm dia UPVC Pipes
25 mm dia UPVC Pipes
Supply and Fixing in position of 3HP Jet Pump of best and approved quality including cost of Jet accessories,1 No of G.I Motor cover, cost of Electric starter and main switch of approved quality, charges for fixing the motor in position with necessary G.I. brackets, bolt, nuts and testing the motor etc., complete as directed by the departmental officers.
Fire figting
Supply and fixing of Fire fighting application oblique type stainless steel Hydrant Valve of size 63mm dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table “E”, bolts & nuts with washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, installation of Fire Fighting Application 180 degree swinging type, hose reel drum with 20mm dia braided thermoplastic hose of 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20mm dia ball valve and open and close spray nozzle, warm clip, etc., as per the standard pattern of any reputed make at every floor nearer to hydrant valve, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, and fixing in position of Fire Fighting Application Hose of 63mm dia of 15 metres length binded by copper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 as directed by the Departmental Officers. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR/ LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, and fixing in position of Fire Fighting Application 63mm dia stainless steel short length Branch Pipe with hexagonal type spray nozzle of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe as per IS 1239 to withstand a developing pressure of 10 kg. / sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: JINDAL / EQUIVALENT.
100mm dia
80mm dia
25mm dia
Wrapping and coating anti-corrosive treatment for the following under ground MS pipe having one coat of anti corrosive metal primer, one layer of asphalt tar tape wound over the MS Pipe as per standard methods as per standard specifications and as directed by the Departmental Officers.
100mm dia
Supply, erection, testing and commissioning of following sizes of Heavy Duty Foot Valve including all accesories, such as, MS flange of table ‘E’, gaskets, bolts & nuts, etc., installed at end of 150 / 200mm dia suction pipe line at sump including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete and as per standard specification and as directed by the Departmental Officers. Make: NORMEX / KARTAR / EQUIVALENT
80mm dia
Supply, erection, testing and commissioning of cast iron body and bronze internal non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary MS flange of table ‘E’, gaskets, bolts & nuts including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: NORMEX / KARTAR / EQUIVALENT
100mm dia
80mm dia
Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal Non-return valve of following sizes to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.
100mm dia
Supply, erection, testing and commissioning of Gun Metal Gate Valve of size 50mm dia size including necessary MS flange of table ‘E’, gaskets, bolts & nuts etc., installed at pump house delivery line for the purpose of priming water to suction line including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: LEADER / EQUIVALENT.
Supply, erection, testing and commissioning of Gun Metal Non-Return Valve of size 50mm dia including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc., installed at pump house delivery line for the purpose of priming to suction line so that to control one way including conveying, fixing and incidental charges etc., complete as per standard specification and as directed by the Departmental Officers. Make: LEADER / EQUIVALENT.
Supply and laying of following sizes of Armoured Aluminium / Copper Cables for electrical motor, control panel, pressure switch, jockey motor etc., all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: POLYCAB / PARACON / FINOLEX / EQUIVALENT.
3 core 10 sq.mm. armoured copper cable
2 core 2.5 sq.mm. armoured copper cable
Supply, erection, testing and commissioning of Pressure Gauge with 0 to 14 kg. range of reputed make with necessary valve, milling thread MS coupling fixed at delivery pipe line in pump house to read the developing pressure including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: H- GURU / ISI MAKE / EQUIVALENT.
Supply, erection, testing and commissioning of suitable Pressure Switch of reputed make line Indfoss or Donfoss including necessary valves, couplings, etc., connected with electrical main control panel and setup at proper differential so as to auto start and auto stop the electrical motor, jockey motor including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., completed as per standard specification and as directed by the Departmental Officers. Make: DONFOSS / INDFOSS / ISI MAKE / EQUIVALENT.
Supply, erection, testing and commissioning of 180 LPM, 70 metres Head Pressurization Pump with 10HP electrical motor of Kirloskar make with suitable base frame including necessary vibration bad mounting etc., including conveying, fixing and incidental charges, etc., complete as per standard specification and as directed by the Departmental Officers. Make: KIRLOSKAR / EQUIVALENT.
Supply, erection, testing and commissioning of Fire Fighting 4 Way Fire Brigade Inlet with necessary gun metal 63mm dia non return spring shutter arrangements, so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: KIARTAR / OMEX / EQUIVALENT.
Supply, erection, testing and commissioning of Air Release Valve of 20mm dia, so as to release airlock in 100mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: KARTAR / EQUIVALENT.
Designing, Fabrication and fixing of Riser Supporting Clamp using 50 x 50 x 6 mm M.S 'L' angle, fabrication in line with Building Pillers,20 mm including the charges of cutting, Grinding, welding, Painting with one coat of Metal Primer and twoc Coats P.O Red Enamel paint, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete and as per standard specification and as directed by the Departmental Officers.
Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT
Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT
Supply and fixing new PVC sintex tank of approved quality and make including loading and unloading charges and with necessary lifting charges and connection to GI/PVC pipes and without disturbed the masonary or RCC work wherever necessary action complete.
Manufacturing, supplying and fixing of Teakwood ornamental Entrance door of size 1.20x2.10m with the following specification. The outer frame of ornamental Entrance Door of size 150x100mm Teak wood scantling. The door consists of openable area 1.06x2.03m with single leaf. The each openable shutter consists of Top Panel for 1.10m height and bottom vertical panel for a height of 1.00m. The Shutter bottom rail is of 200x50mm size and middle, top and side rails are of size 150x50mm with corner designed beading works. The shutter pannel is of 50mm thick T.W.planks with special curving works. The outer frames corners are designed border works single side for entrance outer frame and on both sides for middle frame. The cost includes all kinds of furniture fittings, such as special type heavy Brass Aldrop 300x20mm 1 No, special type heavy Brass tower bolt 300mm length 1 No and 200mm length 1no, special type heavy brass hinges 200mm length 4Nos, special type door stopper 1 No, special type Ornamental door handles 2 Nos, Door bush and Door stopper etc., All the members are finshed with two coats of melamine polish outer the priming coat complete and as directed by the departmental Engineers.
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete.
Electrical
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) ( 4 points / Coil) Higher End
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End
Wiring with 3 x 1.5 sq.mm. (22 / 0.3) PVC insulated unsheathed single core copper conductor of 1100V grade in suitable steel conduit pipe concealed / surface mount in wall and ceiling with accessoires with necessary accessories with suitable colour for light looping point (8 points per coil) (Secondary or Looping Point)
Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour
Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion
Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour
Supply and fixing of 3nos.6A two module 5 pin socket , 3nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 2nos.6A two module 3 pin socket , 2 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
supply and fixing of 1nos 6A two module 5 pin socket, 1no 6A one model switch with model cover plate (plastic) on suitable module concealed box (GI) in flush with wall with connections. Higher end
Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 20Amps DP plug and socket in sheet enclosure with 32A DP MCB inflush with wall with earth connection. (For AC plug) Legrand (MDS) /Hagger (L&T) make)
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board of double door type with metal door with IP43 protection with 1 No. 25A DP 30mA RCCB as incoming and 6 Nos. 6A to 32A SPMCB outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB's should be with ISI mark (ELDB)
Supply and fixing of 12 way triple pole neutral MCB VTPN distribution board in sheet steel enclosure, door type with metal door with IP43 protection with Four pole 100A MCB as incomingand 4Nos. 6A to 32A TP MCB and 24Nos 6A-32A SPMCB as outgoing in flush with wall and making good of the concealed portion with earth connection.The MCBDB and MCB's should be ISI mark (SD-598)
Supply and fixing of 8 way triple pole neutral MCB 7 segment distribution board in sheet steel enclosure, door type with metal door with IP43 protection with Four pole 63A MCB as incoming, 3nos 40A 30mA RCCB as sub incomers and 24 Nos. 6A to 32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection.The MCBDB and MCB's should be with the ISI mark (like LDB / PDB) Higher end
Supply and fixing of 12 way triple pole neutral MCB 7 segment distribution board in sheet steel enclosure, door type with metal door with IP43 protection with Four pole 63A MCB as incoming, 3nos 40A 30mA RCCB as sub incomers and 36 Nos. 6A to 32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection.The MCBDB and MCB's should be with the ISI mark (like LDB / PDB)Higher end
Supply and fixing of 63A 4P 30mA RCCB in sheet enclosure in flush with wall with earth connection (AC ODU ) Higher end
supply and fixing of 63A FP Sheet Steel Enclosure with suitable 63A FP MCB on wall with suitable necessary connection. Higher end
Supply and fixing of 32A DP MCB in suitable sheet steel enclosure with inter connection. Higher end
Supply and Run of 1 of No.8 SWG copper wire for earth connection
Supply and Run of 25mm x 3mm Tinned Copper flat with necessary clamps/ supports on wall/ground to earth connections
Supply and run of 1 of 6sqmm CU wire for earth connection, including cost of all materials etc. all complete in all respects complying with relevant standard specification and as directed by the departmental officer.
Supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of 4Feet LED 20W Fitting with LED 20Wtube (HigherEnd)complete with Tw roundblocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting
supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 1 metre down rod on the existing fan clamp
Supply and erection of GI cable trays including tees, bends, right angles etc. including all fixing accessories like anchor fastner, GI threaded down rod, slotted channels, clamps, bolt nuts etc. as per site conditions of the following sizes:-
Perforated tray
600 x 70mm x 2mm
300 x 50mm x 2mm
150 x 50mm x 2mm
100 x 50mm x 2mm
Supply and Fixing of Tray cover
305 x 15mm x 2mm
155 x 15mm x 2mm
105 x 15mm x 2mm
Supply and laying of 3 Core X 4.0 Sqmm copper armoured cable
Supply and proiving End terminations of 3 Core X 4.0 Sqmm copper armoured cable
Supply and laying of 3 Core X 2.5 Sqmm copper armoured cable
Supply and proiving End terminations of 3 Core X 2.5 Sqmm copper armoured cable
Supply and laying of 3 Core X 1.5 Sqmm copper armoured cable
Supply and proiving End terminations of 3 Core X 1.5 Sqmm copper armoured cable
Supply, Installation, Testing and Commisoning of of 3C 1.5sqmm PVC insulated unarmoured sheathed FRLS flexible multistrand copper cable(WHITE - UPS and BLACK - Raw power) in existing trays / raceways / conduits with all accessories as reqd.
Supply, Installation, Testing and Commisoning of of 3C 2.5sqmm PVC insulated unarmoured sheathed FRLS flexible multistrand copper cable(WHITE - UPS and BLACK - Raw power) in existing trays / raceways / conduits with all accessories as reqd.
Supply, Installation, Testing and Commisioining of of 3C 4.0sqmm PVC insulated unarmoured sheathed FRLS flexible multistrand copper cable(WHITE - UPS and BLACK - Raw power) in existing trays / raceways / conduits with all accessories as reqd.
Supply, Installation, Testing and Commisioining of of 3C 6.0sqmm PVC insulated unarmoured sheathed FRLS flexible multistrand copper cable(WHITE - UPS and BLACK - Raw power) in existing trays / raceways / conduits with all accessories as reqd.
Supply, Installation, Testing and Commisioining of 100 x 45mm Aluminium Trunking box of 1.6mm thick and should be earthed every 3meters with 2.5sqmm copper wire including with all hardwares and accessories as required including all clamps and hardwares for fixing the same. Rate shall be inclusive of including floor cutting and rough plastering.
Supply, Installation, Testing and Commisioining of 50 x 25mm Aluminium Trunking box of 1.6mm thick and should be earthed every 3meters with 2.5sqmm copper wire including with all hardwares and accessories as required including all clamps and hardwares for fixing the same. Rate shall be inclusive of including floor cutting and rough plastering.
Supply and installation of powder coated MS Junction box of following sizes. The Aluminium junction box shall be earthed with 2.5sqmm copper wire with all hardwares and accessories as required including all clamps and hardwares for fixing the same.
Supply and Fixing of 15KVA 3 PHASE UPS (Three Phase In & Single Phase out) CAPACITY - SYSTEM WITH BATTERY - 2 HOURS BACK-UP
Supply and Fixing of 5KVA 1 PHASE UPS (Single Phase In & Single Phase out) CAPACITY - SYSTEM WITH BATTERY - 2 HOURS BACK-UP
Supply and erection of 10mm chequer plate with one coat of primer over a coat of enamel for stair case and landing area.
Earthing arrangements with GI Earth Plate including charcoal and salt with necessary excavation in all soils and to full depth as may be required and masonry work, re-filling the sides of foundation with excavated earth as per the standard specification and as directed by the Departmental Officers.
Supply and run of 1 of No.10 SWG CU wire for earth connection, including cost of all materials etc. all complete in all respects complying with relevant standard specification and as directed by the departmental officer.
Supply and run of 1 of No.12 SWG CU wire for earth connection, including cost of all materials etc. all complete in all respects complying with relevant standard specification and as directed by the departmental officer.
Supply and run of 1 of 25x6mm CU flat for earth connection, including cost of all materials etc. all complete in all respects complying with relevant standard specification and as directed by the departmental officer.
Supply & Fixing of 2m x 1m Rubber Mat
Supply & Fixing of First Aid Box complete with all First Aid Medicines
Supply & Fixing of Shock Treatment Chart fixed in glass frame
Supply & Fixing of Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms
Supply and clamping of 4 x 10 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps
Supply and clamping of 4 x 16 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps
Supply and clamping of 3-1/2 x 25 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps
Supply and laying of 3-1/2 x 300 sq.mm PVC LTUG aluminium armoured cable in already laid cable tray.
Supply and laying of 3-1/2 x 400 sq.mm PVC LTUG aluminium armoured cable in already laid cable tray.
Supply and fixing of brass cable gland for 4 x 10 sq.mm. PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 4 x 10 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Supply and fixing of brass cable gland for 4 x 16 sq.mm. PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 4 x 16 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Supply and fixing of brass cable gland for 3-1/2 x 25 sq.mm. PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3-1/2 x 25 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Supply and fixing of brass cable gland for 3-1/2 x 300 sq.mm. PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3-1/2 x 300 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Supply and fixing of brass cable gland for 3-1/2 x 400 sq.mm. PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3-1/2 x 400 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Lightning Protection System
Supply and running of Aluminium alloy Solid Round Conductor with 8mm dia of material AlMgSi as per IEC 62561-2 with Conductor Holder, glue, connectors, joints etc.
Supply and fixing of Air termination rod 16/ 10 mm( Lightning rod) 1.2m
Supply and fixing of Air termination rod 16/ 10 mm( Lightning rod) 2m
Supply and fixing of Air termination rod 16/ 10 mm( Lightning rod) 3m
Supply and fixing of Lightning counter - LCD display and battery
Supply and fixing of S.S test joint
Supply and running of Rust resistant non corossive 10 mm dia Copper Bonded Steel round conductor for Earth termination
Supply and fixing of S.S. conductor holder
Supply and fixing of Maintenance Free earthing with Copper rod of 17.2 mm dia and 3m length
Supply and running of 25mm X 6mm GI strip
Supply and running of HDPE Pipe 50mm / 38mm
Supply and running of HDPE Pipe 90mm / 76mm
Supply and running of Conduit Pipe 19mm (3/4”) Heavy Gauge with accessories
Supply and running of Conduit Pipe 25mm (1”) Heavy Gauge with accessories
Supply and running of Conduit Pipe 32mm (1 1/4”) Heavy Gauge with accessories
Panel - Supply, Installation, Testing and Commissioning of Indoor type LT Switchboards, Floor mounting type, Bottom/Top entry. Refer SLD for component details Enclosure: Compartmentalized Single front CRCA SHEET/CRGO (Cold rolled grain oriented sheet steel).Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm IP class:IP52/IP42 for Indoor/IP55 with weather proof enclosure for outdoor.Bus bars: Electrolytic grade conductivity as per standard IS 5082.Bus bars: Electrolytic grade conductivity as per standard IS 5082.Bus bar Material: Aluminium / Copper as specified with PVC heat shrinkable sleeves. Bus bar supports: DMC/FRP/SMC.Bus bar joints: Shrouded/Tinned.Protection releases: As per SLD (Adjustable over current & short circuit unless otherwise specified).Ics=Icu for all breakersUtilization category: All MCCB/ACB's shall be Cat:A for Ltg & raw power input distribution panel shall be with Cat: B.Louvers: Busbar chamber shall have louvers with fine mesh inside Shade: Epoxy powder coatedDesign: Modular type Design: Modular type Cable entry: As per site condition. For Humidified areas the copper bus bars shall be coated with tin. Note: 1. The Panel shall be fully as per the requirement of Electrical Inspectorate/ EB authorities.2. Auxiliary contactor to be provided along with auto-manual switch where ever required.3. All Incoming Breakers shall have LED RYB ON OFF TRIP Indication & Outgoing shall have LED 'ON / OFF / TRIP' indications without fail.4. CTs shall be of cast resin type only and CT burden shall be 10VA and class 1.0 accuracy shall be provided. 5. All doors to have double rubber gasket with shutter assembly & door seating frame.6. All AC feeders will have time delays of 0-60 Seconds.7. All MCCBs of 250A and above for non-ups loads will be microprocessor based and all the panel incomer MCCB shall be of microprocessor based. 8. All DLMs to be of dual source meters with RS485 port unless otherwise specified.9. The current density for Aluminium bus bars shall be 0.8 only.10. The current density for Copper bus bars shall be 1.2 only.12. All MCCB's shall have plug setting from (70 -100%) for < 250A & (40 - 100%) for > 250A. 13. All Lighting / RP and Lift panels shall have ELR for incomer 14. All test certificates must be provided immediately after commissioning.15. SAFETY CERTIFICATE FOR THE PANELS SHALL BE PRODUCED FROM CEIG.16. All meters shall be Digital type only.17. FRLS PVC copper wires shall be used for control wiring. 18. The Manufacturer should have the CPRI approval certificate for this capacity.
MAIN MV PANEL
INCOMER
1Nos – 630A 4P 35kA MCCB with Microprocessor releases
Breaker shall consists of following Metering Compartment:
1 Set – 3Nos. 630/5A CT CL1.0 10VA for Metering
1No. - Flush mounting Digital type Multi function meter with RS 485 port ( A,V,PF,kW ,kVA ,kVAr ,kWh ,kVAh )
1 Set – Indication lamps for Breaker ON(Red), Breaker OFF (Green), Breaker Trip (Amber) with control MCBs
SOLAR INCOMER
1Nos – 250A 4P 35kA MCCB with Microprocessor releases
Breaker shall consists of following Metering Compartment:
1 Set – 3Nos. 250/5A CT CL1.0 10VA for Metering
1No. - Flush mounting Digital type Multi function meter with RS 485 port ( A,V,PF,kW ,kVA ,kVAr ,kWh ,kVAh )
1 Set – Indication lamps for Breaker ON(Red), Breaker OFF (Green), Breaker Trip (Amber) with control MCBs
OUTGOINGS
2 Nos – 320A TPN 35kA MCCB with Microprocessor releases
Breaker shall consists of following Metering Compartment:
1 Set – 3Nos. 320/5A CT CL1.0 10VA for Metering
1No. - Flush mounting Digital type Multi function meter with RS 485 port ( A,V,PF,kW ,kVA ,kVAr ,kWh ,kVAh )
1 Set – Indication lamps for Breaker ON(Red), Breaker OFF (Green), Breaker Trip (Amber) with control MCBs
2Nos – 250A TPN 35kA MCCB with Microprocessor releases
Breaker shall consists of following Metering Compartment:
1 Set – 3Nos. 250/5A CT CL1.0 10VA for Metering
1No. - Flush mounting Digital type Multi function meter with RS 485 port ( A,V,PF,kW ,kVA ,kVAr ,kWh ,kVAh )
1 Set – Indication lamps for Breaker ON(Red), Breaker OFF (Green), Breaker Trip (Amber) with control MCBs
2Nos – 160A TPN 35kA MCCB with Microprocessor releases
Breaker shall consists of following Metering Compartment:
1 Set – 3Nos. 160/5A CT CL1.0 10VA for Metering
1No. - Flush mounting Digital type Multi function meter with RS 485 port ( A,V,PF,kW ,kVA ,kVAr ,kWh ,kVAh )
1 Set – Indication lamps for Breaker ON(Red), Breaker OFF (Green), Breaker Trip (Amber) with control MCBs
3 Nos – 100A TPN 35kA MCCB with Microprocessor releases
Breaker shall consists of following Metering Compartment:
1 Set – 3Nos. 100/5A CT CL1.0 10VA for Metering
1No. - Flush mounting Digital type Multi function meter with RS 485 port ( A,V,PF,kW ,kVA ,kVAr ,kWh ,kVAh )
1 Set – Indication lamps for Breaker ON(Red), Breaker OFF (Green), Breaker Trip (Amber) with control MCBs
1No - TYPE T1 surge protection device with circuit breaker protection
All CT's are Cast Resin insulated type.
BUS BAR RATING:
One set: 630A TPN 35kA for 1 sec .Suitable CU bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus as per CEA Rules & Regulations.
CABLE ENTRY - BOTTOM
Cable Gland Plate : 3mm thick Al sheets
Supply, Installation, Testing and Commissioning of ESSENTIAL PANEL
Main incomer Breaker: 250A MCCB ,25KA TPN -1no
Multi function Meter (A V F P.F KW KVA KWH KVAH) with RS485port, 250/5A 10VA CL:1.0 CT and wiring, Indication lamp - 1set
1No - TYPE T1+T2 surge protection device with circuit breaker protection
Outgoing Breaker: 160A TPN MCCB 25ka-2nos
Outgoing Breaker: 63A TPN MCCB 25ka-11nos
Outgoing Breaker: 32A TPN MCCB 25ka-2nos
Bus Bar: 250A TPN 35KA for 1 sec. Suitable CU bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus as per CEA Rules & Regulations.
Supply, Installation, Testing and Commissioning of AC PANEL - 1&2
Main incomer Breaker: 320A MCCB ,25KA TPN -1no
Multi function Meter (A V F P.F KW KVA KWH KVAH) with RS485port, 250/5A 10VA CL:1.0 CT and wiring, Indication lamp - 1set
1No - TYPE T1+T2 surge protection device with circuit breaker protection
Outgoing Breaker: 80A TPN MCCB 25ka-3nos
Outgoing Breaker: 63A TPN MCCB 25ka-4nos
Outgoing Breaker: 32A TPN MCCB 25ka-5nos
Bus Bar: 250A TPN 35KA for 1 sec..Suitable CU bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus as per CEA Rules & Regulations.
Supply, Installation, Testing and Commissioning of UPS PANEL - 1&2
Main incomer Breaker: 63A MCCB ,25KA TPN -1no
RYB ON OFF TRIP Indication lamp - 1set
Outgoing Breaker: 32A TPN MCB 10ka-4nos
Outgoing Breaker: 32A DP MCB 10ka-6nos
Bus Bar:63A TPN 25KA for 1 sec .Suitable CU bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus as per CEA Rules & Regulations.
Supply, Installation, Testing and Commissioning of LIGHTING PANEL - 1
Main incomer Breaker: 100A MCCB ,25KA TPN -1no
Multi function Meter (A V F P.F KW KVA KWH KVAH) with RS485port, 100/5A 10VA CL:1.0 CT and wiring, Indication lamp - 1set
1No - TYPE T1+T2 surge protection device with circuit breaker protection
Outgoing Breaker: 32A TPN MCB 10ka-10nos
Bus Bar: 100A TPN 25KA for 1 sec .Suitable CU bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus as per CEA Rules & Regulations.
Supply, Installation, Testing and Commissioning of POWER PANEL - 1
Main incomer Breaker: 160A MCCB ,25KA TPN -1no
Multi function Meter (A V F P.F KW KVA KWH KVAH) with RS485port, 160/5A 10VA CL:1.0 CT and wiring, Indication lamp - 1set
1No - TYPE T1+T2 surge protection device with circuit breaker protection
Outgoing Breaker: 63A TPN MCCB 25ka-10nos
Bus Bar: 250A TPN 35KA for 1 sec .Suitable CU bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus as per CEA Rules & Regulations.
Supply and erection of GI cable trays including tees, bends, right angles etc. including all fixing accessories like anchor fastner, GI threaded down rod, slotted channels, clamps, bolt nuts etc. as per site conditions of the following sizes:-
Ladder type trays
Supply and running of 600 x 70mm x2mm
Supply and running of 450 x 50mm x2mm
Supply and insallation maintenance free GI Earthing System comprising of 50mm dia and 3 mtr. long earth electrode of low carbon steel rod with 100 micron bonding and 25 kgs. of carbon based environment friendly backfill compound and suitable funnel, clamp with necessary 450x450x600 mm masonry work and with 38mm RCC cover slab for the brick masonry.
Supply & Laying of 25x3mm GI. Flat
Supply & Laying of 25x6mm GI. Flat
Supply & Laying of 50x6mm GI. Flat
Supply, Fabrication and Erection of M.S. Material for supports, iron embedded in the wall, steel structure in open area painted with two coats of primer and two coats of enamel paint.
Supplying, fixing, HT/LT cable route markers with 10 cm x 10 cm x 5mm. thick CI plate with inscription thereon, bolted / welded to 35mm x 35 mm x 6 mm. angle iron , 60 cm. long and fixing the same in ground as required. The cable route marker shall be fixed at both the ends of cable joints and at 10 Mts. spacing for straight runs.
Supply, Providing & fixing Fire Barrier mortar Hilti CP 636 of 50 mm thick with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 and UL 1479 for horizontal openings in fire rated floors or slabs and vertical openings in walls for passing service shafts. The service lines could be of various types like electrical cables trays, metal pipes, GI Ducts for AC, etc. The product shall be age tested as per Dafstb and DIBT standards. The product should be tested for mold resistance rating of 0 as determined by ASTM G21-96. The product shall be tested and approved by third party agencies such as UL and FM. The mortar should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable.(for electrical shaft cutout opening closing purpose)
The cables shall be laid in 1.0 mtr deep trench filled with sand to a depth of 150mm below cable and 150mm above the cable and covered with reinforced cable truffs for protection and back filling with fine earth free from stones. (Excess ground materials should be removed and disposed) Suitable hume pipes are to be laid at road crossings.(Ground Excavation & refilling, RCC Truffs, Hume Pipes paid separately)
Excavating the ground for laying the Cables and refilling the same after laying the cable.
Supply and filling the excavated trench with sand before and after laying cable.
Supply and Laying of 1000 x 300 x 50 mm RCC Truff for the above cable.
Supply and Laying of 300mm Dia Hume Pipe.
Control Cable
Supply and laying of 4 Core X 2.5 Sqmm copper armoured cable
Supply and proiving End terminations of 4 Core X 2.5 Sqmm copper armoured cable
Charges towards filing application, preparation of drawings in necessary formats for approval, follow up and arranging approval of drawings, scheme by Local electricity authority / Electrical Inspectorate, obtaining clearance and safety certificate from electricity authority / Electrical Inspectorate (CEIG / CEA) and preperation of As built drawing and handover document (3 set)
Supply, installation, testing and commisioning of interior rated architectural professional lighitng fixture 18W white with 28 OPtic Tolerance + 2 Degree, 1043 Lumens(Tolerance +- 10% with diemshion of over all dia ≤ 56mmx Length in to length≤ 121 surface mounted, deep led mounting, high gloss antiglare reflector, adjutable & 360° rotatable, precision beam IP 20 protection. The housing material should be of die cast aluminium, UV stablized high optical efficiency lense, No glass should be at the bottom, The luminaire should be capable to add attachments like honeucomb louvers, oval lenses, spread lenses, diffusion lens etc. It should have CRI>97 , SDCM≤2. The driver should be intergal (Make - Tridonic, BAG, Osram). Operating temperature should be of -20°C to +50°C range. Minimum 1% dimming. With overvoltage protection. Lifetime of luminaire (L90 - B10 @ Ta-25deg C) should be at least 50,000 burning hours. With Accessories like antiglare cylindrical screen & spread lens. The colour of the outer side of cylindrical screen should be same as the colour of the fixture, inner colour should be Matt Black. The luminaire should be BIS certified. (All the technical parameters of luminaire need approval from lighting consultant) (Make Delta/ Iguzzini/LED Linear
Supply, installation, testing and commisioning of interior rated architectural professional lighitng fixture 13W white with 11 OPtic Tolerance + 2 Degree, 568 Lumens(Tolerance +- 10% with diemshion of over all dia ≤ 56mmx Length in to length≤ 121 surface mounted, deep led mounting, high gloss antiglare reflector, adjutable & 360° rotatable, precision beamIP 20 protection. The housing material should be of die cast aluminium, UV stablized high optical efficiency lense, No glass should be at the bottom, The luminaire should be capable to add attachments like honeucomb louvers, oval lenses, spread lenses, diffusion lens etc. It should have CRI>97 , SDCM≤2. The driver should be intergal (Make - Tridonic, BAG, Osram). Operating temperature should be of -20°C to +50°C range. Minimum 1% dimming. With overvoltage protection. Lifetime of luminaire (L90 - B10 @ Ta-25deg C) should be at least 50,000 burning hours. With Accessories like antiglare cylindrical screen & spread lens. The colour of the outer side of cylindrical screen should be same as the colour of the fixture, inner colour should be Matt Black. The luminaire should be BIS certified. (All the technical parameters of luminaire need approval from lighting consultant) (Make Delta/ Iguzzini/LED Linear
Supply, installation, testing and commisioning of interior rated architectural professional lighitng fixture 18W white with 14 OPtic Tolerance + 2 Degree, 1095 Lumens(Tolerance +- 10% with diemshion of over all dia ≤ 56mmx Length≤ 121 mm surface mounted, deep led mounting, high gloss antiglare reflector, adjutable & 360° rotatable, precision beam IP 20 protection. The housing material should be of die cast aluminium, UV stablized high optical efficiency lense, No glass should be at the bottom, The luminaire should be capable to add attachments like honeucomb louvers, oval lenses, spread lenses, diffusion lens etc. It should have CRI>97 , SDCM≤2. The driver should be intergal (Make - Tridonic, BAG, Osram). Operating temperature should be of -20°C to +50°C range. Minimum 1% dimming. With overvoltage protection. Lifetime of luminaire (L90 - B10 @ Ta-25deg C) should be at least 50,000 burning hours. With Accessories like antiglare cylindrical screen & spread lens. The colour of the outer side of cylindrical screen should be same as the colour of the fixture, inner colour should be Matt Black. The luminaire should be BIS certified. (All the technical parameters of luminaire need approval from lighting consultant) (Make Delta/ Iguzzini/LED Linear
Supply, installation, testing and commisioning of interior rated architectural professional lighitng fixture 24W white with Framer Optic Tolerance + 2 Degree, 552 Lumens Tolerancee +- 10% with dia ≤ 66mmx Length in to length≤ 270 x height≤ 204 surface mounted, deep led mounting, high gloss antiglare reflector, adjutable & 360° rotatable, precision beam IP 20 protection. The housing material should be of die cast aluminium, UV stablized high optical efficiency lense, No glass should be at the bottom, The luminaire should be capable to add attachments like honeucomb louvers, oval lenses, spread lenses, diffusion lens etc. It should have CRI>90 The driver should be intergal (Make - Tridonic, BAG, Osram). Operating temperature should be of -20°C to +50°C range. Minimum 1% dimming. With overvoltage protection. Lifetime of luminaire (L90 - B10 @ Ta-25deg C) should be at least 50,000 burning hours. With Accessories like antiglare cylindrical screen & spread lens. The colour of the outer side of cylindrical screen should be same as the colour of the fixture, inner colour should be Matt Black. The luminaire should be BIS certified. (All the technical parameters of luminaire need approval from lighting consultant) (Make Delta/ Iguzzini/LED Linear
Supply, installation, testing and commisioning of interior rated architectural professional lighitng fixture 10Wwhite with 43 Optic Tolerance + 2 Degree, 780 Lumens Tolerancee +- 10% Length - ≤ 93 x Width ≤ 26 x Height ≤ 50 surface mounted, deep led mounting, high gloss antiglare reflector, adjutable & 360° rotatable, precision beamIP 20 protection. The housing material should be of die cast aluminium, UV stablized high optical efficiency lense, No glass should be at the bottom, The luminaire should be capable to add attachments like honeucomb louvers, oval lenses, spread lenses, diffusion lens etc. It should have CRI>90The driver should be intergal (Make - Tridonic, BAG, Osram). Operating temperature should be of -20°C to +50°C range. Minimum 1% dimming. With overvoltage protection. Lifetime of luminaire (L90 - B10 @ Ta-25deg C) should be at least 50,000 burning hours. With Accessories like antiglare cylindrical screen & spread lens. The colour of the outer side of cylindrical screen should be same as the colour of the fixture, inner colour should be Matt Black. The luminaire should be BIS certified. (All the technical parameters of luminaire need approval from lighting consultant) (Make Delta/ Iguzzini/LED Linear
Supply, installation, testing and commisioning of interior rated architectural professional lighitng fixture 2W black Non integral Optic Tolerance + 60 Degree, 100 Lumens Tolerancee +- 10% Length - ≤ 40mm x Width ≤ 40 x Height ≤ 50 , cabinet type eyeball 1 head LED lumianire, recessed mouting with trim, deep led mounting, antiglare snoot, adjutable, precision beam IP 20 protection. The housing material should be extrudded aluminium, trim should be powder coated in matt black color, UV stablized high optical efficiency lense, No glass should be at the bottom, It should have CRI>95 , SDCM≤2. The driver should be remote Make - Tridonic, BAG, Osram). Operating temperature should be of -20°C to +50°C range. Lofetime of luminaire (L70 @ Ta-25deg C) should be at least 50,000 burning hours. The luminaire should be BIS certified. (All the technical parameters of luminaire need approval from lighting consultant) (Make Regant/Philips/Hybec)
Supply, installation, testing and commisioning of interior rated architectural professional lighitng fixture 4W black Non integral Optic Tolerance + 60 Degree, 300 Lumens Tolerancee +- 10% Length - ≤ 200mm x Height ≤ 50 , cabinet type eyeball 1 head LED lumianire, recessed mouting with trim, deep led mounting, antiglare snoot, adjutable, precision beamIP 20 protection. The housing material should be extrudded aluminium, trim should be powder coated in matt black color, UV stablized high optical efficiency lense, No glass should be at the bottom, It should have CRI>95 , SDCM≤2. The driver should be remote Make - Tridonic, BAG, Osram). Operating temperature should be of -20°C to +50°C range. Lofetime of luminaire (L70 @ Ta-25deg C) should be at least 50,000 burning hours. The luminaire should be BIS certified. (All the technical parameters of luminaire need approval from lighting consultant) (Make Regant/Philips/Hybec
Supply, installation, testing and commissioning of linear Walk over step light 2W IKO3 200 Lumnes Length - ≤ 1200mm x section ≤ 75 x 40mm of following specifications: 1200MM long L shaped aluminium extruded, minimum 0.75 kg/meter, matt black powder coated after phosphochromate treatmen, top LED diffused rectangular oplescent white acrylic with all required hardware, LED drivers and accessories to mount the lumianire CRI>80. The luminaire should be BIS certified. (All the technical parameters of luminaire need approval from lighting consultant) (Make Regant/Philips/Hybec)
Supply, installation, testing and commissioning of linear Walk over step light 2W (Non integral) 200 Lumens ≤ 900mm x section ≤ 75 x 40mm of following specifications: 900MM long L shaped aluminium extruded, minimum 0.75 kg/meter, matt black powder coated after phosphochromate treatmen, top LED diffused rectangular oplescent white acrylic with all required hardware, LED drivers and accessories to mount the lumianire. The luminaire should be BIS certified. (All the technical parameters of luminaire need approval from lighting consultant(Make Regant/Philips/Hybec)
Supply, installation, testing and commissioning of linear Walk over step light 2W (Non integral) 200 Lumens ≤ 600mm x section ≤ 75 x 40mmof following specifications: 600MM long L shaped aluminium extruded, minimum 0.75 kg/meter, matt black powder coated after phosphochromate treatmen, top LED diffused rectangular oplescent white acrylic with all required hardware, LED drivers and accessories to mount the lumianire CRI>80IP 20 protection. The luminaire should be BIS certified. (All the technical parameters of luminaire need approval from lighting consultant) (Make Regant/Philips/Hybec)
Supply, installation, testing and commisioning of interior rated architectural professional linear fixture, 6W (Non integral) Aliminium fiinish 500 Lumens Lenth customized x section ≤ 18mm x 18mm surface mounted luminaire, IP 20 protectionSMD led mounting, adjustable clips. The housing material should be extruded aluminium,CRI>80 SDCM≤3. The driver should be remote (Make - Tridonic, BAG, Osram). The fixture colour should be similar to the surface color where the fixture is to be installed. Operating temperature should be of -20°C to +50°C range. Lifetime of luminaire (L70 @ Ta-40deg C) should be at least 40,000 burning hours. (Make Regant/Philips/Hybec)
SUPPLY, INSTALLATION, TESTING & COMMISIONING OF LIGHTING MANAGEMENT SYSTEM AS GIVEN BELOW. DALI Drivers -1300Nos Non Dali On-Off Curcuits -20Nos 4 Scene Keypads - 12Nos Double Door Distribution Board/Cabinet, IP44 Rated, 16/14 Gauge. With Accessories Like Switch Gears, Din Rails, Neutral Links, Earth Links, Glands etc. It Should Have Space of 300 Modules (1 Module = 1 Single Pole MCB). This Should be Capable to Accommodate Commission All The Controllers, MCB's, Din Rails, Neutral Links, Earth Links, Glands etc. Supply & Laying of 3 Core 1.5 Sq. MM Multistrand Copper Cable Complete with All Respect. - 3000Mtr (Make - Lapp) NX Cable, 2 Pair, No. Of strands/Diameter - 1/0.8 MM, Conductor Material - Solid Base Copper, PVC Insulated, 4 Core, OS, Outer Jacket - 800MtrMaterial - PVC, Temperature Rating - -30° C To +70° C, Voltage Rating - 300. (Make - Belden/Equivalent)
Supply, installation, testing and commisioning of outdoor architectural professional lighitng fixture, 3W 115LM 23.4 DEG Flood light Dark Brown surface mounted light fixture , 3000K D=42mm H=73mm integrated IP 65 Protection ,CRI>80 (Make Linea light/Led linear/alurays)
Supply, installation, testing and commisioning of outdoor rated architectural professional lighitng fixture, 8.4W white Linear light fixture recessed mounted, 3000K D=53mm H=120mm integrated IP 65 Protection (Make Linea light/Led linear/alurays)
Supply, installation, testing and commisioning of outdoor rated architectural professional lighitng fixture, 8W 59LM 9.2DEG SS Recessed up light 3000K D=92mm H=112mmCRI>80 integrated IP 65 Protection (Make Linea light/Led linear/alurays)
Supply, installation, testing and commisioning of Outdoor rated architectural professional lighitng fixture, 10W 1186LM Remote Linear light fixture surface mounted Diffuser , 3000K D=14mm H=14mm CRI>80 integrated IP 65 Protection Type LL1(Make Linea light/Led linear/alurays)
Supply, installation, testing and commisioning of outdoor rated architectural professional lighitng fixture, 200W fiiting IP 65 Protection Type LL1(Make Linea light/Led linear/alurays)
Supply, installation, testing and commisioning of outdoor rated architectural professional lighitng fixture, 200W Linear light surface mounted fiiting IP 65 Protection Type LL2(Make Linea light/Led linear/alurays)
Supply, installation, testing and commisioning of Outtdoor rated architectural professional lighitng fixture, 10W surface mounted Diffuser , 3000K D=15mm H=20mm L=2000mm CRI>80 integrated IP 65 Protection Type LL3 Vertical (Make Linea light/Led linear/alurays)
Supply, installation, testing and commisioning of outdoor rated architectural professional lighitng fixture, 160W linea fitting IP 65 Protection Type LL3 Vertical (Make Linea light/Led linear/alurays)
Supply, installation, testing and commisioning of Outdoor rated architectural professional lighitng fixture, 10W/m 650LM/M surface mounted Diffuser , 3000K D=15mm H=20mm L = 400mm CRI>80 integrated IP 65 Protection Type LL3 Horizontal (Make Linea light/Led linear/alurays)
Supply, installation, testing and commisioning of outdoor rated architectural professional lighitng fixture, 160W Linea light fiiting IP 65 Protection Type LL3 Horizontal (Make Linea light/Led linear/alurays)
VARIABLE REFRIGERANT FLOW (VRF) AIR-CONDITIONING SYSTEM
Inverter Scroll Compressor Modular VRF ODU
Supply, Installation, Testing and Commissioning of BMS Compatible VRF Indoor air conditioning units with direct driven fan, Evaporator coil, high efficient filter, inbuilt microprocessor thermostat, electronic expansion valve, provision of fresh air duct connection, drain pumps for ceiling suspended type and ductable units, necessary ceiling supports & vibration isolators, oil charging, power cabling from nearest socket( 3.0 RMT), control wiring and drain connection, etc. The capacities are as mentioned below:-
Ceiling Suspended Type
2.0 TR VRF 4way Cassette Indoor unit
Supply, Installation, Testing and Commissioning of Wired remote controller including wire between remote and indoor units
Supply, Installation, Testing and Commissioning of Central Remote Controller / equivalent for above circuits for monitoring and Controlling the VRF equipments. The CRC shall consists of LCD display, basic functions like ON/OFF, mode settings, temperature setting, fan speed setting, louver setting, timer, scheduling, holiday mode setting, error code, alarm, emergency trip, sensors, BMS interface bacnet / Modbus for thrid party system integration, etc.
AIR HANDLING UNITS
External Static pressure in the BOQ is of tentative. The vendor shall arrive the external static pressure calculation based on the approved shop drawings. If any enhancement on the actual parameters to meet the project requirement , then the same shall be considered in the quote by the HVAC Contractor. Also, vendor need to submit the total static pressure calculation.
Floor Mounted Air Handling Units with DX Coil (EC fans)
Supply, Installation, Testing and Commissioning of Double Skin Horizontal Air Handling Units as per the specifications. The AHU shall be 45±5mm thick panel with PUF insulation, thermal break profile, filter sections with MERV 8 and MERV 14 filters, commisioning set filters, min 6 row deep multiple DX cooling coil of 0.41mm thick copper tube & aluminium fins, copper header suitable for R-410a refrigerant, multiple EC fans with EC motors, fan outlet Velocity shall not exceed at 9 m/s, multiple expansion kit, communication kit, remote controller, sensor, limit switch, light, inspection glass, etc., spring vibration isolator for fan and motor, factory assembled volume control damper, internal power and control wiring, required length of power cable from the panel to the equipment, GI base frame complete as per specifications as required. AHU noise level shall be less than 65dBA at 1.5m distance. Fan motor shall be IE- 5 type and suitable for 415±10% volts, 50 cycles, 3 phase AC supply. The AHU shall be provided with suitable rating starter panel and components. The electrical panel shall have incoming breaker, single / Multiple outgoing breakers, speed controller, indication lamp, contactor, auto / manual switch, necessary relays, potential free contacts to be interlocked with fire alarm control module to trip the AHU incase of fire. The electrical starter panel shall have necessary relay, and potential free contacts for the following BMS provisions : (1) Auto / Manual command, (2) Auto/ Manual / OFF status, (3) Run status, (4) Trip Status.
The AHU shall have space provision to accommodate the EEV kit, remote controller & communication kit inside the AHUs
Capacity: 16 TR, Dehumidified Air: 4800 CFM, ESP: 30mm WC, Motor rating: 1 x 3.0 kW (Approx)
Capacity: 18 TR, Dehumidified Air: 6300 CFM, ESP: 30mm WC, Motor rating: 1 x 4.0 kW (Approx)
Capacity: 25 TR, Dehumidified Air: 8750 CFM, ESP: 30mm WC, Motor rating: 2 x 3.0 kW (Approx)
Capacity: 27 TR, Dehumidified Air: 12000 CFM, ESP: 30mm WC, Motor rating: 2 x 4.0 kW (Approx)
Capacity: 30 TR, Dehumidified Air: 12000 CFM, ESP: 30mm WC, Motor rating: 2 x 4.0 kW (Approx)
Capacity: 36 TR, Dehumidified Air: 14400 CFM, ESP: 30mm WC, Motor rating: 2 x 5.5 kW (Approx)
DX SYSTEM
SUPPLY & INSTALLATION OF AIR-CONDITIONER WITH COPPER COIL
2.0 TR Split Type AC Unit - 5 Star Rated
Supply and installation of 5 KVA capacity Automatic Voltage Stabilizer with time delay relay
Supply and fixing of MS stand for fixing outdoor unit
Refrigerant pipes for 2.0 TR with 13 mm insulation
VRF SYSTEM DOWNSTREAM WORKS
REFRIGERANT PIPE
6.4mm Dia
9.5mm Dia
12.7mm Dia
15.9mm Dia
19.05mm Dia
22.2mm Dia
25.4mm Dia
28.6mm Dia
31.8mm Dia
35.0mm Dia
41.2mm Dia
44.5mm Dia
53.98mm Dia
REFNET
Supply and fixing of Refnet joint
Supply, Installation, Testing and Commissioning of PVC Copper Unarmoured Shielded Cable as per OEM standard for Control cabling between indoor to outdoor units and CRC or BMS to VRF system. The rate shall be inclusive of 25mm dia Heavy duty PVC conduit necessary accessories and fixing arrangement.
SUPPLY AND FILLING REFRIGERANT GAS
DRAIN PIPE
Supply, Installation, Testing and Commissioning of Drain pump, tank including fitting arrangments of Ceiling suspended unit with controller, flow sensor and alarm- Aspen make, model max hi-flow, flow 55 l/hr & head 5m or equivalent
CABLE TRAY
Ladder type
150 mm x 50 mm
300 mm x 50 mm
450 mm x 50 mm
Powder coated Perforated tray
150 mm x 70 mm
300 mm x 70 mm
450 mm x 70 mm
Powder coated tray with Cover
150 mm x 70 mm
300 mm x 70 mm
450 mm x 70 mm
Supply, Installation, Testing and Commissioning of MS flat / angles / channels supports of various sizes including cutting, welding, grinding, fixing accessories and one coat of primer & two coats of enamel paints, minor civil works like grouting existing floors and walls etc. as required.
AIR DISTRIBUTION SYSTEM
Note: The colour shade for the air distribution equipments like ducts, diffusers, grilles, etc shall be approved by the Client / Architects before procurement and execution. The powder coating shall be 50 to 40 microns
The air distribution system comprises with support system of approved makes, wire suspension system for exposed duct areas, accessories like anchor fasteners and tie-rods, cradles, hot dip galvanised bolts and nuts, 4mm thick self-adhesive neoprene rubber gasket, stiffeners, chipping and plastering of openings made for duct supports etc., filling the gap with fibre glass wool and with fire sealant complete as per specification. The rates quoted shall include turning vanes, straightening vanes, splitters, inspection doors probe, provisions for BAS sensors, inlets with test openings enclosures complete with locking caps, chain, gaskets, insulating plugs, and extension for insulated ductwork etc. Rate shall be inclusive of Pressure testing as per SMACNA standards
RECTANGULAR DUCT
Supply, Fabrication and erection of fabricated ducting made up of GI Sheets of 22 Gauge thickness
Supply, Fabrication and erection of fabricated ducting made up of GI Sheets of 24 Gauge thickness
FLAT OVAL DUCT
Supply, Installation, Testing and Commissioning of air distribution system consists of factory fabricated GI sheet Flat Oval (elliptical) duct with pre insulated 13 mm thickness nitrile rubber materinal shall be FM & UL approved factory made fittings like bends, tees, wire hanging support with crimp arrangement supports, spacing and fixing as per SMACNA standards. The rate shall be inclusive of powder coating (Mat finish) for the ducts as per the approved colour shade by Client / Architect.
1.2mm thick GSS ducting (Gauge 18)
1.0mm thick GSS ducting (Gauge 20)
0.8mm thick GSS ducting (Gauge 22)
0.6mm thick GSS ducting (Gauge 24)
DOUBLE SKIN PLENUM
Supply, Installation, Testing and Commissioning of factory fabricated, 25-mm thick PUF filled double skin Supply air plenum suitable with extruded Al. profiles. The thickness of outer & inner skin GI sheet shall be 0.8 mm. The plenum shall be fabricated only after shop drawing approval, as per site conditions and assembled at site. The outer skin color shall be matched with the AHU unit colour else colour share to be get approval from Client / Architect.
Supply, Installation, Testing and Commissioning of GI louver volume control damper (low leakage) made out of 20G thick galvanized sheet steel frame and blades of 16G galvanized steel with suitable links, handles, levers and quadrants for manual control of volume of air flow and for proper balancing of air distribution system.
Rectangular
Supply, Installation, Testing and Commissioning of motorized Fire damper with sleeve (UL555) in supply air/return air streams. The damper shall be made out of 16G thick galvanized sheet steel frame and blades of 16G galvanized steel with air tight arrangement. The damper shall be provided with control panel, BMS compatible actuator(UL) of the motorized Damper shall have required torque to ON / OFF the actuator with 220 V / 24 V transformer duly encased and wired, combined smoke and heat sensor and transmitters, control / communication cables, etc. The control panel shall be suitable for receive/send signal from the Fire Alarm System and status shall be monitored thru BAS.The Rate shall be inclusive of the control cable from socket to actuator and actuator to control box (each 3Mts Approx).
Smoke & Fire Dampers.
BMS compatible Actuators UL with Control Panel & Wiring
Supply and fixing of extruded aluminum powder coated, Supply and return Air Grilles / Diffusers with Volume Control Damper
Supply, Installation, Testing and Commissioning of Powder coated supply air Extruded Aluminium Curved grilles with collar damper.per specifications. The rate shall inclusive of aluminium collar damper, necessary fixing and supporting arrangement for the grilles
Supply and fixing of Flexible Canvas Connection
Supply and fixing of Duct Mouth Dampers
Supply, Installation, Testing and Commissioning of Aluminium powder coated Fresh air & exhaust arrangement with storm proof louvers, volume control damper, MS weld mesh bird screen / mounting frame - 100mm louver spacing and 45 deg angle suitable for protection against splashing rain water fixed within a right aluminium frame.
Construction of PCC pedestals (1:4:8) for VRF Outdoor unit as per design approved by Architect / Consultant. The rate shall inclusive of Chipping & pastering, cleaning, etc.making the surface to as required.etc
INSULATION
The rate shall be inclusive of surface preparation, applying adhesive, laying insulation material, joint treatments with suitable overlapping / adhesive tape, etc., as per the tender specification and drawings.
The overlapping insulation on the duct flanges shall be 250mm max and this overlapping of insulation shall not be measured separately for billing purpose.
The measurements for insulation of ducts shall be made in actual square metres of bare uninsulated duct surface through all dampers, flanges and fittings.. The overlapping of insulation shall not be measured separately for billing purpose
Supply, Installation, Testing and Commissioning of Refrigerant pipe insulation with XLPE insulation materinal shall be FM & UL approved class O (tubular form) covering with reinforced aluminium foil with PET layer for UV protection and damage against mechanical impact.
19mm thick insulation for 6.4mm dia Copper pipes
19mm thick insulation for 9.5mm Dia Copper pipes
19mm thick insulation for 12.7mm Dia Copper pipes
19mm thick insulation for 15.9mm Dia Copper pipes
19mm thick insulation for 19.05mm Dia Copper pipes
19mm thick insulation for 22.2mm Dia Copper pipes
19mm thick insulation for 25.4mm Dia Copper pipes
19mm thick insulation for 28.6mm Dia Copper pipes
19mm thick insulation for 31.8mm Dia Copper pipes
19mm thick insulation for 35.0mm Dia Copper pipes
19mm thick insulation for 41.2mm Dia Copper pipes
19mm thick insulation for 44.5mm Dia Copper pipes
19mm thick insulation for 53.98mm Dia Copper pipes
Supply, Installation, Testing and Commissioning of Drain pipe insulation with XLPE insulation materinal shall be FM & UL approved class O (tubular form) covering with reinforced aluminium foil with PET layer for UV protection and damage against mechanical impact.
13mm thick insulation for 25mm Dia UPVC pipes
13mm thick insulation for 32mm Dia UPVC pipes
13mm thick insulation for 40mm Dia UPVC pipes
13mm thick insulation for 50mm Dia UPVC pipes
Supply, Installation, Testing and Commissioning of acoustic lining on the walls of mechanical plant room covered with 50 mm thick, 48 Kg/ Cu. Mtr with 600 X 600 tile form fiber glass sheet type with RP tissue covered with 26 SWG perforated aluminium sheet as per the approved shop drawings & specifications. The insulation work shall be fixed in suitable Galvanized steel (50 mm thick Clip on type) frame work
ACOUSTIC INSULATION
Supply, Installation, Testing and Commissioning of Acoustic insulation - materinal shall be UL approved, open cell Nitrile Rubber foam. The density of the same shall be within 140-180 Kg/m3. The maximum surface temperature the material should withstand is 105º C and minimum temperature should be -20ºC. The material should conform to Class 1 rating for surface spread of Flame as per BS 476 Part 7. The Thickness of the insulation material shall be as follows
15mm thick
UNDERDECK INSULATION- XLPE
Supply, Installation, Testing and Commissioning of underdeck insulation material shall be UL & FM approved with class O Crosslinked polyolefin foam with factory applied reinforced aluminium foil with PET layer
25mm thick
VENTILATION SYSTEM
Supply, Installation, Testing and Commissioning of Ventilation fan circular type units. The unit shall be 0.6mm GIS construction, direct driven centrifugal fan, High efficiency motor with IP21 protection, spring vibration isolator for fan and motor, with Sliding type filter, Fire retardant canvass connections on both sides, with acoustic enclosure for fan & noise level not exceed 65 dBA at 1.5m distance, internal power and control wiring, GI base frame complete as per specifications as required. Fan motor shall be suitable for 230V, 1 phase, 50Hz AC supply. Rate shall be inclusive of Suitable power cable from isolator to equipments (7.5 RMT approximately).
Fresh Air Fan with MERV 8 filter
Air flow rate : 400 CFM - 15mmWC
Supply, Installation, Testing and Commissioning of Ventilation fan cabinet inline type units. The unit shall be 0.6mm GIS construction, direct driven centrifugal fan, High efficiency motor with IP21 protection, spring vibration isolator for fan and motor, with Sliding type filter, Fire retardant canvass connections on both sides, with acoustic enclosure for fan & noise level not exceed 65 dBA at 1.5m distance, internal power and control wiring, GI base frame complete as per specifications as required. Fan motor shall be suitable for 230V, 1 phase, 50Hz AC supply. Rate shall be inclusive of Suitable power cable from isolator to equipments (7.5 RMT approximately).
Fresh Air Fan with MERV 8 filter
Air flow rate : 700 CFM - 15mmWC
Air flow rate : 1200 CFM - 15mmWC
Air flow rate : 1400 CFM - 15mmWC
Exhauts Air Fan
Air Qty: 300 CFM, ESP: 20mmWC
Air Qty: 4000 CFM, ESP: 20mmWC
Supply, Installation, Testing and Commissioning of Ventilation fan circular type units. The unit shall be 0.6mm GIS construction, direct driven centrifugal fan, High efficiency motor with IP21 protection, spring vibration isolator for fan and motor with acoustic enclosure for fan & noise level not exceed 65 dBA at 1.5m distance, internal power and control wiring, GI base frame complete as per specifications as required. Fan motor shall be suitable for 230V, 1 phase, 50Hz AC supply. Rate shall be inclusive of Suitable power cable from isolator to equipments (7.5 RMT approximately).
Exhauts Air Fan
Air Qty: 300 CFM, ESP: 20mmWC
Supply, Installation, Testing and Commissioning of AC Exhaust Fan 300mm (12”) Sweep (Light Duty)
SMOKE EXTRACT SYSTEM
Air Qty: 3000 CFM, ESP: 20mmWC , - Smokespill fans
Air Qty: 3700 CFM, ESP: 20mmWC , - Smokespill fans
Air Qty: 4200 CFM, ESP: 20mmWC , - Smokespill fans
Air Qty: 5500 CFM, ESP: 20mmWC , - Smokespill fans
Air Qty: 6000 CFM, ESP: 20mmWC , - Smokespill fans
RECTANGULAR DUCT
Supply, Fabrication and erection of fabricated ducting made up of GI Sheets of 20 Gauge thickness
Supply, Fabrication and erection of fabricated ducting made up of GI Sheets of 22 Gauge thickness
Supply, Fabrication and erection of fabricated ducting made up of GI Sheets of 24 Gauge thickness
INTRUSION ALARM SYSTEM
Supply, Erection, Testing and Commissioning of 24 Zone GSM Controller with key pad & display to know the door status The Rate Inclusive of power supply unit and wiring, cable gland, fishers, back box with cover plate, screw, base saddle, and other necessary etc.
Supply, Erection, Testing and Commissioning of 4core 1.0 sqmm multistrand copper PVC insulated FRLS armoured cable clamping at wall/ purlin/ ceiling / column etc. The Rate Inclusive of cable gland, base saddle with MS cover plate and necessary back box etc.all complete as reruired.
Supply, Erection, Testing and Commissioning of 'NO' door magnetic sensor with requires accessories.
Supply, Erection, Testing and Commissioning of Vibration sensors for Windows in areas with requires accessories.
Supply, Erection, Testing and Commissioning of Dual element Passive Infra-Red (PIR) motion sensors detection range 12m, Detection angle 110° with multi angle wall bracket, ABS housing requires accessories.
Supply, Erection, Testing and Commissioning of 6 HZS Hooter horn 12V DC, Audible Sound 85 db @ 1 mtr range. It is used for Emergency Alarm System, flashing every second, 4 candela settings:15/30/75/110cd output and 2 different tone audible sound. The Rate Inclusive of cable gland, fishers, back box with cover plate, screw, base saddle, and other necessary etc.
Design, Supply, Delivery, Hoisting, Erection, Testing and Commissioning including the freight up to site, Insurance, for the following items as shown on the equipment data and drawing for complete and satisfactory operation and to meet the NBC / BIS / State Fire Authority recommendation.
ADDRESSABLE FIRE ALARM SYSTEM
Addressable Fire Alarm Control Panel consists of displayboard which will have 160 Character Display with Touch key pad, Mother board 32 Bit Processor, In-built RS-485Networking Circuit for peer to peer networking, In-built USB 2.0 Port, Loop Card having 254 devices of bothdetectors and modules in a single line circuit, SLC supportsboth Class A and Class B wiring Approval: UL Listed
Addressable Active Repeater Panel consists of displayboard having 160 Character Display with Touch key pad,Mother board which will have 64 Bit Processor, InbuiltRS-485 Networking Circuit for peer to peer networking.
Addressable Detectors with base with Binary coded addresssetting. Dual LED’s for 360° visibility.
Smoke detector
Multi Sensor - Heat Cum Smoke detector
Addressable Manual Call Point - Resettable type - withback box with Binary coded address setting with StatusLED for 360° visibility.
Fault Isolator Module capable of monitoring shorted loopcircuit and automatically restore communications.
Supply, Erection, Testing and Commissioning of Addressable Control Module with Non Supervised Dual potential free contacts. Addressing shall be with user friendly rotary switches / Auto addressing. Shall have an LED indication for normal and active modes. The Rate Inclusive of cable gland, fishers, back box with cover plate, screw, base saddle, and other necessary etc.
Supply, Erection, Testing and Commissioning of Addressable Control Relay Module with Non Supervised Dual potential free contacts. Addressing shall be with user friendly rotary switches / Auto addressing. Shall have an LED indication for normal and active modes and operating at 24V DC, 2A, rated at 230V, provided. The Rate Inclusive of cable gland, fishers, back box with cover plate, screw, base saddle, and other necessary etc.
Supply, Erection, Testing and Commissioning of Addressable Monitor Module for monitoring the field NO/NC devices. Shall have Binary Coding Setting Dip Switch, Shall have an LED indication for normal and Active Modes. The Rate Inclusive of cable gland, fishers, back box with cover plate, screw, base saddle, and other necessary etc.
Supply, Erection, Testing and Commissioning of Sounder cum strobe 24V DC, Audible Sound 85 db @ 1 mtr range. It is used for Fire & Emergency Alarm System, flashing every second, 4 candela settings:15/30/75/110cd output and 2 different tone audible sound. The Rate Inclusive of power supply and wiring, cable gland, fishers, back box with cover plate, screw, base saddle, and other necessary etc.
POWER SUPPLY : 24VDC Power Supply with 5 amp rating,having LED indications for Power supply ON,batteryFail,Battery Charging,battery back up etc.
Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers.
Supply, Erection, Testing and Commissioning of 2core 1.5sqmm multistrand copper PVC insulated FRLS unarmoured cable (Outer sheath of cable shall be RED in colour) clamping at wall/ purlin/ ceiling / column etc. The Rate Inclusive of cable gland, base saddle with MS cover plate and necessary back box etc.all complete. complying with relevant standard specifications. (RED) (Only for the Drops - MCPs & hooters)
Supply, Erection, Testing and Commissioning of 40mm dia HDPE Pipe for laying of fire cable including necessary accessories like bend, junction box fixing of clamps etc., complete. Rate shall be inclusive of Excavation of earth and refilling with and 300 mm above and below of pipe then with earth consolidation compaction upto formed ground level.
Supply, Erection and Testing of 25mm dia PVC Heavy duty conduit for laying of cable including necessary accessories like bend, junction box fixing of clamps etc., complete. The conduit shall be recessed in wall including chipping, rough plastering etc.
Design, Supply, Delivery, Hoisting, Erection, Testing and Commissioning including the freight up to site, Insurance, for the following items as shown on the equipment data and drawing for complete and satisfactory operation and to meet the NBC / BIS / State Fire Authority recommendation.
The proposed Block B building Fire alarm detectors, modules, manual call point, hooters, cable routing etc. shall be integrated with Block A fire alarm panel and recommissioned with necessary accessories.
(Vendor is responsible for safe handling of detectors, modules, manual call points, devices, cables with accessories etc., if any damage occurs during removing etc., same shall be procured by vendor and install without extra cost)
Design, Engineering, Supply, Fabrication, Erection, Testing, Commissioning and Handing over of 1No 8 Persons passenger lift MRL as per following technical specifications including all taxes and duties. Technical Specifications: 1. Location: Bronze Gallery ,Govt.Museum,. Egmore,Chennai - 8. 2. No of Lift: One No. 3. Type of Lift: Passenger 4. Capacity of Lift 8 Persons. (544Kgs) 5. Speed: 1.00 mtr /Sec 6. Type of Drive: Microprocessor based Specific variable Voltage variable Frequency V3F drive with enhanced ride comfort and near zero leveling functions. 7. No of floor: Ground+1floors(2floors). 8. Total Travel: 8 Mtrs. (approximate) 9. Leveling Accuracy: High level accuracy with smooth & Jerk free stopping 10. Construction of car: Special car made of stainless steel finish No.4 hair line finished car panel complete with SS finished fall ceiling ,flooring, lighting fan etc., 11. Position of Machine: Directly above the lift level. 12.No. of Landing Entrance: One in front.
13.No. of Car Entrance: One in front only. 14. Landing Entrance Door: (V3F) side opening power operated sliding stain less steel No.4 hair line finished door with full height ultra slim infra red door safety curtain. 15. Lift well : 1900mm(width)x1900mm(depth). 16.Lift pit depth available: 1600mm 17.Car size: 1300mm(width)x1100mm(depth) X2200mm (height) (as per IS 14665(Part I) – 2000) 18.Car clear Opening: 1200mm widex 2000mm Height (as per IS 14665 (Part-I) – 2000) 19.Lift Machine Room less 20.Power Supply: 400/440v, 3 phase, 50 Cy/Sec A.C supply for power and 230 V, 50 Hz single phase AC supply for light. 21.Control: Micro processor Computer based – simplex collective Full collective logic system with/without attendant mode.
22.Car fittings: Compact fluorescent Lighting with 1 No.300mm sweep cabin fan. Lift Well: RCC construction with Brick masonry. 23. Indication: Up/Down Digital Direction scroll type and position indicator for all landing and in car. 24.Emergency Alarm Bell: Battery Operated Alarm Bell to be provided with automatic charging device. 25. Emergency Light: Battery operated Light to be provided with automatic charging device. 26. Fireman’s switch: To be provided at ground floor. 27. Minor Builders Work: To be Provided by lift contractor. 28.Scaffolding: To be provided by lift Contractor. 29.Stainless Steel sill angles and facia Plates: To be provided by lift contractor. 30. Steel for lift Machinery: To be Provided by lift contractor. 31.Servicing and Maintenance: Free Comprehensive servicing and maintenance should be provided by lift contractor during the guarantee period of one year.
32.Provision of intercom with phone: to be provided by lift contractor. 33.Lift License: Preparation of drawing, Payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate and lift license as per lift act should be done by lift contractor. 34. Automatic rescue device – To facilitate the landing of the nearest floor at the time of power failure This shall consist of suitable type battery system with charges inverter ,under voltage protection system etc. 35. Floor annunciate+C64r with music. 36. Special futures: a) Infra red door sensor with b) Full height screen. c)Full width half height rear panel Mirror. d)Voltage stabilizer for circuit control. e) Tubular Stainless Steel f)hand rail in car g)signal Fixtures h)Vandal proof S.S. button with S.S. cover i)Stain less steel door frames VF door operator
j)Call register signal k)Pit ladder l)Braille buttons m)Stainless steel facia for car operating panel and landing fixtures. n)ON-OFF switch for fan and light o) Over load warning indicator 37 .Over speed governor, phase failure and phase reversal relay, alarm bell, Guide brackets for car and counter weight, rubber padding under winding unit, Motor of adequate capacity, single reduction worm gear, electro magnetic brake with compression springs, car safety gears, buffer, electro mechanical door locks, emergency key, side supporting angels, motor over load protection devices, final limit switch, main suspension ropes, counter weights, lifting joint joist for mounting the machineries. 38. Guarantee: Guarantee for the Materials& workmanship of equipments complete should be offered by the Lift firm for a period of not less than one year. 39. Site testing in accordance with IS14665 should be carried out at the time of handing over. (SR)
Supply and clarnping of 3 ½ x 35 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps
Supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. PVC armoured LTUG cable with earth connection
Supply and providing cable end termination of 3-1/2 x 35 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 1 nos 40A TPMCB and .9Nos 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End
Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with Module Plastic surface mounting box on wall with 6A one way module switch with module front plate with painting of Suitable colour for Open PVC Light point / fan point (for electronic regulator) 5 points / coils Higher End.
Supply and fixing of WT bulk head fitting with guard suitable for 15 W LED Bulb
Supply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete without provision of hole in the wall
Earthing as per ISI specification with an earth electrode of 2.1mtr class ‘B” GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mmx6mm with necessary funneling arrangement with necessary masonry work with 38 mm RCC cover slab for brick masonry works.
Supply, Testing, Commissioning and Handing over of 1No 250 KVA Diesel Generator set of 0.8 P.F. Three Phase 415/420 Volts, 50 C/S, 1500 RPM CPCB-IV Norms Approved capacity compressing of Engine BHP/ suitable BHP of water cooled clock wise rotating feed pump with 200KW/250KVA operating capacity brush less alternator close coupled underneath fuel tank standard, safeties, LLOP with stop solenoid, battery with lead, Electric start and vibration fitting & accessories and Standard Manual panel control panel as detailed below including transporting of unloading changes. (A). ENGINE Water cooled diesel engine suitable for Generator application with a shaft output suitable at 1500 RPM under NTP conditions. The Engine shall comprise the following standard fitting flexible coupling, fly wheel air cleaner ,fan blower, radiator, water pump, fuel pump, fuel filter lubricating oil filter etc., (B) 12/24 Volt Electronic starting Equipment Complete with starter motor, dynamo, standard batteries with cable, flexible exhaust piping of 50 cms length
( C ) ENGINE INSTRUMENT PANEL / MOUNTED Starting push button/ staring key, lubricating oil temperature gauge, lubricating oil pressure gauge, water temperature gauge, safety control for low lubricating oil pressure, safety control for high water temperature, safety control for over speed, hour meter (mechanical) and RPM indicator, battery charging ammeter. The engine should be capable of providing 10% over load for one hour for every 11 hours continuous at full load .D). Alternator 250 KVA/200 KW capacity of brush less alternator AC, Three phase 50 c/s, 415/420V,0.8PF, 1500 RPM under NTP conditions conforming to ISO-8528 Part-V to be means of coupling
ERECTION AND TESTING AND COMMISSIONING Erection of 250 KVA Generator set with suitable foundation Pedestal height 5 ft with proper alignment of Genset including crane charges
Supply and installation of exhaust piping of sufficient length with suitable MS pipes so as to extend outside the generator room with necessary thermal insulations
Supply of lubricating oil and first charging of starting battery and supply of 320 ltrs for 250 KVA diesel to run the Gen set for minimum of 8 hours Diesel Rs.96+transport Rs.4=100.00
supply and fixing of 6 core 2.5 Sqmm copper cable on wall with MS clamps
Supply and fixing of 400 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with earth connection only.
Supply and laying of 2runs 3 ½ x 240 Sqmm PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 meter and refilling the earth to make good
Supply and clamping of 2 runs of 31/2 x 240 Sqmm PVC LTUG armoured LTUG cable with earth connection
Supply and fixing of brass cable gland for 3 ½ x 240 Sqmm PVC armoured LTUG cable with earth connection
Supply and providing cable end termination of 3 ½ x 240 Sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete
CLOSED CIRCUIT TELEVISION SYSTEM
Supply and Installation of 5MP IP Bullet Camera with motorised zoom.
Supply and Installation of 32 Channel Network video recorder with 2 SATA Interfaces.
Supply and Installation of 8TB Hard Disk Drive.
Supply and Installation of 24 Port PoE Switch.
Supply and Installation of 12 port Light guide Interconnect Unit (LIU) fully populated with modules/ adapters.
SC-LC Cables, Connectors etc.
Supply and Installation of 6U Rack with Accessories, connectors etc.
Supply and Installation of 43" Display, to be connected with NVR for camera viewing, complete with wall/ceiling/floor mounting arrangement as per specifications(24/7).
Supply and Installation 42U Rack with Accessories,connectors etc. as per specifications.
Supply and Laying of Cat-6 UTP 4 pair FRPVC Cable in existing conduit/pipe on surface/recess/concealed, with connectors, termination etc.
Supply and Laying of Optic Fibre Communication Outdoor cable (6 core, SMF) in existing pipe on surface/ recess/ concealed, with connectors/ adaptors, termination etc.
Supply and Laying of 25 mm dia, PVC Conduit (ISI Marked) with all bends, Tees & other accessories.
HT WORKS
11 KV OUTDOOR RING MAIN GEAR (RMG) Supply Erection testing and commissioning of 11KVA 25KA 630Amps 3 Panel HT outdoor RING MAIN GEAR Switch board suitable for outdoor installation comprising two incomer panels with Air Break /load breaks switches and one outgoing panel with vaccum circuit breakers complete confirming to TANGECO standard specification and as per the following specification with Mechanical inter lock between incomers
1.Supply and Erection of 1 no. draw out type 11KVA 25 KA 630 Amps Horizontal draw out /Horizontal VACCUM CIRCUIT BREAKER Fitted with motor (230 V AC )operater spring charged Mechanism, with ON and OFF mechanical indicator Anti pumping Device 110 V DC Shunt trip and closing coils (DC source of supply to be derived from a power pack suitable for three triping and two closing operation incorporated on Incoming panel only) Mechanical operation counter,4 No + NC spar AUX contact with contact multiplication contractor for customer use. Automatic Safety shutter, Mechanical close /Trip knob Mechanical ON/OFF Indication, operation andle,230V AC to 110V DC Power pack operation Handle.
2.Supply and Erection of 2 nos. of 11KV 630 Amps 25 KA HT Air Break /Load Break switch with mechanically inter locked each switch, front operated spring assisted manual closing mechanism 2 NO +NC Aux contact.
3. 11KV /Root 3/110V Root 3- Three phase 3 limb 50 VA Class 0.2 Resin cast Draw out type potential Transformer complete with HT and LT HRC Fues with sealing arrangement - 3 NOS.
4.Current Transformer of suitable Ratio /5-5A Dual core (core 1-5VA clas 0.2 for metering &bcrore 2-15VA 5 P20 For protection -3 nos
6. Protection: IDMT two over current and one earth fault Relay with high set Inst Elements 1.3 seconds 1No Master Trip relay (Megawin MVAJH 13 equivalent) -1 No.
7. Breaker ON/OFF indication LED type 2 Nos. AutonTrip /Healthy Trip and spring charged indication LED type -3 Nos phase indicating Lamps.
8. TNC Breaker control switch -1No Local Remote seletor switch -1No-
9. panel Mounting Surge Arrester 9KV,10KA -3No.
10. 630Amps copper bus bar PVC sleeved & requried.
11.Submission of RMG Drawing to TANGEDCO panel earthing arranging CT/PTInspection and obtaining TANGEDCO aproval (DATA-X)SOR(M - 1958) Including Civil work for RMG Plinth of height 150mm Foundation 2.5Mtr x1.55Mtrx150mm, Liasioning charges for TNEB MRT Higher official Inspection at manufacturing unit factory, Transport charges and Erection, testing and commissioning charges.
11 KV INDOOR VACCUM CIRCUIT BREAKER Supply Erection,testing and commissioning of 11KV, 25KA, 630Amps HT INDOOR THREE PANEL VACCUM CIRCUIT BREAKER For Consumer POS With 18KV, 10kA Polymer Type Surge Arrester. Horizontal Draw Out VCB fitted with Manual / Motor Operated spring charging mechanism with 230V AC Motor & Motor Control Switch, Mechanical ON/OFF indicator Operation Counter, Automatic safety shutters & push Shunt trip Coil, 110V DC. Closing Coil, 110V DC. Spare auxiliary contact, 6NO+ 6NC. Anti pumping Feature, 110V DC. Power pack 230V- 110V AC/110V DC Potential Transformer, Three Phase, Resin cast, Dry type, Fixed Potential transformer with one set of HTFS/LTFS and one no. Neutral Link of Ratio: (11KV/V3)/(110V/V3) Current Transformer, Single phase, Resin Cast, Dry Type Current Transformer,
Core 1: for meter, Cl-0.5s, 5VA,
Core 2: for protection, Cl-5P20, 15VA. Metering, MFM, Digital Ammeter & Digital Voltmeter With Fault Level tripping & Fault Recording. Protection, Numerical Non-directional IDMT. (M - 1954) Including Civil work for RMG plinth of height 150mm foundation 7.5m x 1.55m x 150mm, liasioning charges for TNEB MRT Higher official inspection at manufacturing unit factory, Transportation charges and Erection , testing and commissioning charges.
11 KV OUTDOOR VACCUM CIRCUIT BREAKER Supply Erection,testing and commissioning of 11KV, 25KA, 630Amps HT Outdoor Single PANEL VACCUM CIRCUIT BREAKER For Consumer POS With 18KV, 10kA Polymer Type Surge Arrester. Horizontal Draw Out VCB fitted with Manual / Motor Operated spring charging mechanism with 230V AC Motor & Motor Control Switch, Mechanical ON/OFF indicator Operation Counter, Automatic safety shutters & push Shunt trip Coil, 110V DC. Closing Coil, 110V DC. Spare auxiliary contact, 6NO+ 6NC. Anti pumping Feature, 110V DC. Power pack 230V- 110V AC/110V DC Potential Transformer, Three Phase, Resin cast, Dry type, Fixed Potential transformer with one set of HTFS/LTFS and one no. Neutral Link of Ratio: (11KV/V3)/(110V/V3) Current Transformer, Single phase, Resin Cast, Dry Type Current Transformer Core 1: for meter, Cl-0.5s, 5VA,Core 2: for protection, Cl-5P20, 15VA. Metering, MFM, Digital Ammeter & Digital Voltmeter With Fault Level tripping & Fault Recording. Protection, Numerical Non-directional IDMT. Transportation charges and Erection , testing and commissioning charges
HT CABLES
Supply and Laying of 300 sq.mm. 3 core HT XLPE 11KV (E) SISMV11U3 x 3002424 armoured cable in suitable size RCC cable truf in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and clamping of 300 sq.mm. 3 core HT XLPE 11KV (E) SISMV11U3 x 3002424 armoured cable on post or on wall with MS Clamps.
Supply & Fixing of 300 sq.mm. 3 core HT Cable Indoor Terminations XLPE 11KV (E) - Belted PILC Cables - EPKT 4961 .
500KVA TRANSFORMER Supply erection testing and commissioning of 500KVA/11KV /433V off load tap changing copper wound outdoor type distribution transformer conforming to relevant ISI 180 Level -1 standard and fitted with the following: a)HV cable end box suitable for Connection 3 core 300 Sq mm 11 KV, XLPE HT cable b) LV cable end box suitable for connection 3 runs of 31/2x300 Sq mm LTUG Cable c)Conservator with shut off valve d) Conservator drain plug valve e) Dehydration silicagel breather f) Expansion vent g) 4Nos plain rollers H) Thermometer pocket with dial type thermometer with caillary tubing with maximum reading position. i) Drain plug/valve) Filter valve j) Oil filling hole and cap k) Oil level gauge l) two body earhing terminals m) Rating and terminal marking plate n) Lifting hooks /lifting eyes,jacking pad to facilitate movement of transformer and easy handiling-1 No (Each)
n) Lifting hooks /lifting eyes,jacking pad to facilitate movement of transformer and easy handiling-1 No (Each) n) OFF load hand opereted tap changing switch at standing height from ground level. o) Tapping on primary widing for voltage and vaiation 5% to +5% p)Neutral on LV side to be available for 4 wire supply and brought out thought bushing for earthing q)Air release device r)The transformer should be supplied with first filling of oil All removable cover shall be provided with weather proof hot oil from the tank Sakthi/Rowson /Voltech /IPL )/35i Eco power/eq Including Charges for civil work and unmovable for the transformer wheel arrest for AI frame work with fixing on the transformer 100mm x 50mm channel provided, Transportation and transit insurance @2%, Erection , testing and commissioning charges with Test report
AUTOMATIC POWER FACTOR CORRECTION
RELAY PANEL (APFCR PANEL)
Supply and erection of 200 KVAR 415/440Volts 50Hz 3 Ph automatic power factor correction panel, 9 stage, (at 0.95 lag), made up of powder coated, 16 SWG CRCA sheet steel enclosure with 1 1/2" x 1 1 1/2" x 1/2" AI Frame work with RCC concreting foundation and bolted to masonry pedestal with Delta Connected capacitors (BCH/EPCOS) MOO Type operating in multiple stage with 3 current and Voltage Transducers (CVT) at the phases simultaneously to activate the desired power factor switching time between steps 120 seconds, switching off time in case of fault 3 seconds with a LCD display to show the following Parameters. a. Vr – R phase Line Voltage b. Vy – Y phase Line Voltage c. Vb – B phase Line Voltage d. Ir – R phase Line current e. Iy – Y phase line current f. Ib – B phase Line Current g. KW – Present Kilo Watts h. RKVA – Present KVAR Demand
i. KVA – Present KVA j. PF – Present Power Factor k. Number of Capacitor bank ON/OFF l. Provision to indicate the imbalanced load m.Provision to indicate the change in phase Sequence n. The APFC Panel Should also have built in protection for current imbalance. For high Voltage/Low Voltage cut off, single phase Preventer, provision for inductor coil to cater the in-rush currents, line surges, Current Limiters, Current Sensor, etc., with connection complete and as per the relevant IE Rules. Eight Stages of Automatic Power Factor control panel with necessary connection. Make. (Matrix /L&T /or equivalent
MV Panel Supply, erection, testing and commissioning of 800A draw out type floor mounted MV cubical panel board bus bar chamber dust and vermin proof and accommodating the following d sine with Thermal Magnetic Release MCCB’s and 2 No. ACB as Incomer units with the following items of work complete to satisfy the latest IE rules and CEIG guidelines. Supply and fixing of suitable bus bar chamber made up of 16SWG MS sheet steel(1.6mm) with 4Nos.2Runs 2” X 1/2” tinned copper bus bar for 3 phases and neutral (2x 50mm x 12mm) and 2 Nos. of ear thing bus of size 1” X 1/8 tinned copper bus(25mm x 3mm) on suitable bus bar insulator(Epoxy insulator) with maximum creep age distance and supported on MS Base channel frame work of size 4”X 2”X ¼”–1Set
Incoming 1)Supply and fixing of 1 No. 800A 4pole ACB, 1No 630 4 POLE ACB , microprocessor based, EDO/MDO breaker 433V LT ACB confirming to IS 13947–2 IEC 60947–2 with suitable capacity with all accessories for standard horizontal manual draw out type ACB equipped with auxiliary contacts and all accessories for closing and opening operation with Micro processor Based SR 18 G relay, over current trip device adjustable to LTD, STD andrelease for over current protection UV release with time delay, EF release short circuit protection, Mains CTs for 3 phases lockout, features, separate mold base for each pole for easy maintenance all relevant protection safety accessories as per CEIG, IE rules in force with inter connection and terminations as required in specification.
Outgoing 1) Supply and fixing of 630A TPN MCCB-2Nos 2) Supply and fixing of TPN 400A MCCB 2Nos.250A TPN MCCB 2Nos-. Inter connecting the all LT ACB’s and MCCB’s to bus bar with suitable insulated tinned copper flats and painting/PVC sleeve color coding of phases and neutral indication. Double Earth connection of the MCCB’s and ACB’s to earth bus using suitable tinned copper flats by 2 runs of 1”X 1/8” Supply and fixing of LED lamp arrangements with toggle switches to the control to each phases and with rigid connection in suitable separate compartments within the cubicle by CEIG rules with , 2 sets, of supply and fixing Electronic Trivector EC,300N class 0.5 flush mounting L&T or equivalent make–ModelER300N.Supply and fixing of danger board withSiemens grey powder coating with super scribing the names of places to which supply is fed feeder sizes of cables direction of cables etc. Erection of panel board complete with suitable foundation bolts and nuts including suitable M.S Channel, concreting ,testing andcommissioning (L&T,C&S,SIEMENS,ABB)
Supply and Laying of 3 runs 3 1/2 x 300 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated ata depth of 0.75 metre and refilling the earth to make good.
Supply and clamping of 3 runs3 1/2 x 300sq.mm PVC LTUG armoured Alu cable on post or on wall with MS Clamps.
Supply and Laying of 3 1/2 x 240 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated ata depth of 0.75 metre and refilling the earth to make good
Supply and clamping of 3 1/2 x 240 sq.mm PVC LTUG armoured Alu cable on post or on wall with MS Clamps.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.58 MB
PQconditionbronzegallery.pdf
Tender Documents • 0.43 MB
BOQ_778886.xls
BOQ • 0.90 MB
PriceTenderbronzegallery.pdf
Additional Documents • 1.15 MB
Download all tender documents and submit your bid