Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹80.0 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹91.6 L+₹9.6 L (11.7%)Rejected-Finance RONGMEN B IV BARAPANI PO SHILLONG 793103 | RI BHOI | MEGHALAYA | 793103 | 2 | Rejected-Finance Not being Lowest | |
| 3 | 3₹91.8 L+₹9.8 L (11.9%)Rejected-Finance | 3 | Rejected-Finance Not being Lowest | |
| 4 | 4₹95.9 L+₹13.9 L (16.9%)Rejected-Finance 16 GANGADHAR BABU LANE C R AVENUE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | 4 | Rejected-Finance Not being Lowest | |
| 5 | 5₹96.2 L+₹14.2 L (17.3%)Rejected-Finance | 5 | Rejected-Finance Not being Lowest |
Tender Value
₹72.8 L
EMD Value
₹1.3 L
Closing Date
26 Mar 2022, 6:00 pmClosed
CWE SHILLONG
HQ CWE SHILLONG SE FALLS SHILLONG MEGHALAYA - 793011
SPECIAL REPAIR AND REPLACEMENT OF LT OVERHEAD LINE WITH LT UNDER GROUND XLPE UG CABLE FOR OFFRS MD ACCN AND ALLIED WORKS AT UMROI MIL STN UNDER GE UMROI
2021_MES_490106_1
8515/UMR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
UMROI
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE UMROI
₹1.3 L
Yes
20 May 2022
19 Feb 2022
28 Mar 2022
19 Feb 2022
26 Mar 2022
12 Mar 2022
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cable all as specified and directed at site.
Excavation in trenches in hard/dense soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cable all as specified and directed at site.
Returning, filling in including spreading, leveling, watering and well ramming excavated soft/loose soil in layers , all as specified and directed at site
Removing excavated material surplus (soil ) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
M&L for sand cushioning to under ground cable using locally available fine clean dry river sand over,under ground UG cable laid in trenches and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge.
M&L for common burnt clay bricks (locally available best quality), sub-class ‘B’ for cover LT underground cables , laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and directed.
S&F in repair for 50mm bore tubing “light grade” in trenches/ on pole for protection of cables complete all as specified & directed by Engineer-in-charge.
All as per item No 7.00 above but for 40mm bore complete all as specified and directed by Engineer-in-Charge
All as per item No 7.00 above but for 80mm bore complete all as specified and directed by Engineer-in-Charge
Supply ,laying & testing in trenches / pole cable XLPE insulated screened PVC bedded galvanised steel strip or wire, armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 volts earthed grade of cross sectioal area of 300 Sqmm and 3.5 core wth all fitting accessories eg. lux etc. specified and directed .
All as per item No 10.00 above but for 240 sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
All as per item No 10.00 above but for 185 sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge .
All as per item No 10.00 above but 70 sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge
All as per item No 10.00 above but for 35 sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge
All as per item No 10.00 above but for 16 sq mm 4 core complete all as specified and directed by Engineer-in-Charge
Dismantling of old/rusted aluminium conductor steel reinforced of any size and removing the same from site of work all as specified and directed by Engineer-in-Charge. Note :- The dismantling of the existing LT OH line, ACSR conductor and its connected items will be removed after testing completion of UG cable network.
S&F new PVC cable Junction Box IP66 "halogen free and weather proof" for out door installation size 200 x 160 x 98 mm suitable for street light incoming and outgoing cables up to 10 to 25 sqmm 4 core (with terminal) & MCB SP 6 Amp, including nuts,bolts,cable glands & MS clamps fixed to pole all as directed.
Material & labour for Sub main wiring with two runs of single core 2.5 Sqmm (Nominal Area) in aluminium/steel conduit insulated and unsheathed multi standed copper conductor cable LT 1100 volts grade drawn thorugh into metallic rigid conduit including PVC insulated stranded copper conductor nominal cross section area 2.5 Sqmm contineous earth continuity wire complete all as specified. Note : Two run of 2.5 Sqmm cable one run of 2.5 Sqmm earth continuity wire for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run complete all as specified and directed.
M&L for earthing complete with Galvanized earth plate electrode 60 cm x 60cm x 6.00 mm buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with the top edge not less than 1.5 mtr below ground level connected to GI strip 20 X 3 mm as earth lead by means of bolts, nuts, check nuts and washers of steel and other end connected to earthing test point including funnel, 20mm dia GI pipe medium grade for watering pipe and 32mm bore GI pipe, light grade for protection of GI strip, wire mesh, charcoal or coke and common salt in alternate layers all around the earth electrode compacted thickness 15 cm, earthing pit in PCC (1:3:6) type C1, 50 mm thick pre-cast RCC cover slab (1:2:4) type B1 set in CM (1:4), reinforced with 8 mm dia TMT bars @ 10 cm c/c and suitable handle of 10 mm dia MS round bars including earth work in excavation in soft/loose soil, desposal of soil not exc. 50 meter complete and testing on completion all as shown in electrical plate No-3 of MES schedule, part-I complete all as specified and directed. NOTES 1). The unit rate include GI strip from top of earth plate upto 7.5 meter above ground level. completion complete and including taking down old u/s.
Supply, install, testing and commissioning outdoor type LT panel of suitable size , CPRI approved factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both ront and rear door painted with powder coated paint and aluminium bus bar 750 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items:- (Main Panel NO-I). Incoming :-(a) ACB 4 Pole,630 A, 415 V, 50 kA.- 01 Nos. (C&S,AHA06N4P*MP3.1(S),Micro Pro3.1). (b) LCD multifunction meter - 01 No. (c) CTs 320/5 A - set of 3. (d) Phase indicator lamps (RYB) -set of 3. (e) Aluminium bus bar 4 strip -750 amps. (f) Internal connection by aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc. Outgoing :-(a) MCCB, 4 Pole, 200 Amp, 415 V, 35 kA - 02 No (for FP-I And FP-II). (b) MCCB, 4 Pole, 63A, 415 V, 36 kA - 02 Nos.(for Chhotapani & spare 1- Nos). (c) MCB,TPN, 32A, 240 V, 18 kA - 01 No. (For street light).
Supply, install, testing and commissioning outdoor type LT panel of suitable size , CPRI approved factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both ront and rear door painted with powder coated paint and aluminium bus bar 375 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items:- (Main FDR Panel No-II). Incoming :- (a) MCCB, 4 Pole, 250A, 415 V, 25 kA.- 01 No. (b) LCD multifunction meter - 01 Nos. (c) CTs 320/5 A - set of 3. (d) Phase indicator lamps (RYB) -set of 3. (e) Aluminium bus bar 4 strip -375 amps. (f) Internal connection by aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc. Outgoing :- (a) MCCB, 4 Pole, 63 Amp, 415 V, 30 kA - 03 No (for Officer qtr blocks). (b) MCCB, 4 Pole, 200 A, 415 V, 36 kA - 01 Nos.(for FP No-03). (c) MCB, TPN, 32 A, 240 V, 18 kA - 01 No. (For street light)
Supply, install, testing and commissioning outdoor type LT panel of suitable size , CPRI approved factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both ront and rear door painted with powder coated paint and aluminium bus bar 900 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items:- (Main Panel No-III). Incoming :- (a) MCCB, 4 Pole, 600A, 415 V, 50 kA.- 01 No. (b) LCD multifunction meter - 01 No. (c) CTs 320/5 A - set of 3. (d) Phase indicator lamps (RYB) -set of 3. (e) Aluminium bus bar 4 strip -900 amps. (f) Internal connection by aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc. Outgoing :- (a) MCCB, 4 Pole, 200 Amp, 415 V, 36 kA - 01 Nos (for FP No-04). (b) MCCB, 4 Pole, 300 Amp, 415 V, 50 kA - 01 Nos.(for FP No-05). (c) MCCB, 4 Pole, 63 Amp, 415 V, 30 kA - 02 Nos.(for offr qtr blocks)
Supply, install, testing and commissioning outdoor type LT panel of suitable size , CPRI approved factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both ront and rear door painted with powder coated paint and aluminium bus bar 300 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items:- (Feeder Panel-I). Incoming:- (a) MCCB, 4 Pole, 200A, 415 V, 36 kA.- 01 No. (b) Phase indicator lamps (RYB) -set of 3. (c) Aluminium bus bar 4 strip of 300 Amps. (d) Internal connection by aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc. Outgoing:- (a) MCCB, 4 Pole, 63 A, 415 V, 36 kA - 04 Nos.(for 4 offrs block qtrs)
Supply, install, testing and commissioning outdoor type LT panel of suitable size , CPRI approved factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both ront and rear door painted with powder coated paint and aluminium bus bar 300 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items:- (Feeder Panel-II). Incoming:- (a) MCCB, 4 Pole, 200A, 415 V, 36 kA.- 01 No. (b) Phase indicator lamps (RYB) -set of 3. (c) Aluminium bus bar 4 strip of 300 Amps. (d) Internal connection by aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc. Outgoing:- (a) MCCB, 4 Pole, 63 A, 415 V, 36 kA - 04 NoS.(for offrs block qtrs)
Supply, install, testing and commissioning outdoor type LT panel of suitable size , CPRI approved factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both ront and rear door painted with powder coated paint and aluminium bus bar 300 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items:- (Feeder Panel-III). Incoming:- (a) MCCB, 4 Pole, 200A, 415 V, 36 kA.- 01 No. (b) Phase indicator lamps (RYB) -set of 3. (c) Aluminium bus bar 4 strip of 300 Amps. (d) Internal connection by aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc. Outgoing:- (a) MCCB, 4 Pole, 63A, 415 V, 36 kA - 01 No.(for bde cdr house). (b) MCCB, 4 Pole, 63A, 415V, 36 kA - 02 Nos.(01 nos for block no-128, 01 nos for cdr guard resi.)
Supply, install, testing and commissioning outdoor type LT panel of suitable size , CPRI approved factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both ront and rear door painted with powder coated paint and aluminium bus bar 300 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items:- (Feeder Panel-IV). Incoming:- (a) MCCB, 4 Pole, 200A, 415 V, 36 kA.- 01 No. (b) Phase indicator lamps (RYB) -set of 3. (c) Aluminium bus bar 4 strip of 300 Amps. (d) Internal connection by aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc. Outgoing:- (a) MCCB, 4 Pole, 63 A, 415 V,36 kA - 04 Nos.(for offrs qtr blocks)
Supply, install, testing and commissioning outdoor type LT panel of suitable size , CPRI approved factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both ront and rear door painted with powder coated paint and aluminium bus bar 450 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items:- (Feeder Panel-V). Incoming:- (a) MCCB, 4 Pole, 300A, 415 V, 50 kA.- 01 Nos. (b) Phase indicator lamps (RYB) -set of 3. (c) Aluminium bus bar 4 strip of 450 amps. (d) Internal connection by aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc. Outgoing:- (a) MCCB, 4 Pole, 63 A, 415 V, 36 kA - 06 Nos.(for offrs qtr blocks)
Materials and labour for PCC ( 1:4:8) type D-2 Using 40 mm graded stone aggregate as in foundation of stay assembly , poles struts etc. complete all as specified and as directed .
Materials and labour for PCC ( 1:2:4) type B-1 Using 20 mm graded stone aggregate as in couping of pole etc including form work and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed .
S&F in replacement nature switch in enclosure made out of UV stablized, FR grade special moulding compound, rust proof, electric shok proof, vermine proof outdoor pole mountable with mounting bracket made out of FI and nut, bolts, washers including cable glands, openable door with lock comprising with power contactor three phase rating, 20 amps 4 pole-01 no, MCB SP 20 Amps-03 Nos for max load 5kw including taking down existing nature switch,Ip 66 enclosure complete all as directed. MAKE:- Kakatiya Energy System Ltd.cat NO. SWADEEP-66-5kw3p, 5KW, 3P, IP-66 encloser(Hensel make)or equivalent make in Indo asian/Legrand.
Dismantling Barbed wire/chain link fencing of any gauge & size exceeding 4 Kg/Sqm complete all as directed by Engr-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, getting out in soft/loose soil complete all as specified and directed.
M & L type B2 1:2:4 (using 40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire all as specified & directed.
Supply only PVC Coated mild steel Galvanised wire Chain link fencing square mesh of any size and any type, made out of Exc 3.80 mm dia wire complete all as specified & directed
S & F of Mild steel in nosing to steps including embeding in concrete and screwing etc; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 all as specified and directed by Eng-in-charge.
Supply only mild steel 10mm dia round bars to secure Chain link fencing complete all as specified & directed
S & F of Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long having diameter of neck 5 to 10 cm all as specified and directed by Eng-in-charge.
M & L for Preparation of new or previously untreated Surfaces of any description, over 10cm in width or girth,not otherwise described and painting two coats of synthetic enamel paint over a coat of red oxide on steel surfaces of any discription all as specified and directed by Eng-in-charge.
M & L for Surface excavation in Soft/Loose n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out all as specified and directed by Eng-in-Charge.
M&L hard core with broken stone or boulders of gauge 63 mm but n exc.100mm, deposited spread & levelled in layers n.exc 15 cm thick water & rammed to a true surface, complete all as specified and directed.
M & L Precast cement concrete solid blocks in PCC 1:3:6 type C1, using 20 mm graded stone aggregate & set in cement motar 1:6 , embeded in earth vertically not exc. 30 cm deep as in kerb, complete all as specified and directed.
M & L for preparing of new undecorated surfaces (plastered or un-plastered) by brooming down and applying 3 coat of white wash on walls including cornices all as specified and directed by Eng-in-charge.
S & F of pre polished machine pressed precast concrete interlocking paver block any shape and size conforming to IS-2006 of 80mm thickness, M-40 Grade with grey cement and no pigment all as specified and directed by Eng-in-charge.
M & L 30 mm thick Sand filling under floors or in foundations including watering and consolidation all as specified and directed by Eng-in-Charge.
M & L Reinforced cement concrete (nominal mix) in B1 1:2:4 (using 40 mm graded aggregate) as in drain Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses all as specified and directed.
M & L for Formwork to faces of drain walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for fair finished surfaces all as specified.
M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
Add or deduct to the item no.48 above for each 25mm girth or part thereof over or under 30cm complete all as specified and directed
M & L for framed brackets of angles or tees with web and flanges cut to shape drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates. riveting etc. n exc 10 kg brackets, conforming to FE.290. GDE-E-165 (Brackets over 10 Kg Each) to be measured under structural steel all as specified and directed by Eng-in-charge."
M & L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) Fe-410-W(Gde?E-250) quality?B forming holes, without any attachment complete all as specified and directed.
M & L for Preparation of new or previously untreated Surfaces of any description, over 10cm in width or girth,not otherwise described and painting two coats of synthetic enamel paint over a coat of red oxide on steel surfaces of any discription all as specified and directed by Eng-in-charge.
Dismantling insulators any type, any size complete all as directed.
Dismantling of GI Earth wire 40mm or any size complete all as directed.
Reshifting of Transformer within complex 315 KVA as per site requirement from temp pump house, sub stn 5 to sub stn 6 & 7 including transportation and laboure T &P Hydra machine required for shifting of transformer complete including disconnecting the cables/ connection and reconnecting the cables at new shifted site complete all as directed.
M/s Jaiswal and Co
N.V.ENGINEERING
HAMZA CONSTRUCTION CO
SRI HARSHITA ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .