| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.4 L+₹99,362.90 (3.16%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹33.6 L+₹2.1 L (6.73%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹38.6 L
EMD Value
₹77,240
Closing Date
27 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH DELHI CANTT-10
GE NORTH DELHI CANTT-10
PROVN OF RAIN WATER HARVESTING FACILITY FOR REDUCING WATER LOGGING AT MAP PHASE I MAP PHASE II MD ACCN AND KEY LOCATION POINT KLP GATE AT 21 SIG GROUP AT ANAND PARBAT MIL STN AND PROVN TOILET BATHROOM BLOCK FOR OR LINES AT ENTITY B 61 WEU AND PROVN O
2023_MES_579208_1
GE/NORTH-61/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE NORTH DELHI CANTT-10
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE NORTH DELHI CANTT-10
₹77,240
Yes
18 Mar 2023
6 Feb 2023
1 Mar 2023
6 Feb 2023
27 Feb 2023
13 Feb 2023
Amount
B/R Portion:- Surface excavation in soft/loose soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified and directed.
Excavation in trenches n exc 1.5 m wide and n. exc 1.5 m in depth; for foundation n exc 10 sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm in soft/loose soil, complete all as specified and directed.
Removing excavated material n. exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point., complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed.
M&L PCC 1:3:6 type C2 as in in fdn filling and mass concrete using 40 mm graded crushed stone aggregate, complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in surface channel, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in CM 1:6, complete all as specified and directed.
Brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed.
M&L treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (area of the sub structure in contact with backfill to bemeasured) complete all as specified and directed.
M&L treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M&L treating the soil under plinth protection at the rate of 5 liters of emulsion per square metre of surface area complete all as specified and directed.
M&L Treating the soil along with external perimeter of building at the rate of 2.25 litres of emulsion per metre of the perimeter wall complete all as specified and directed.
M&L for 15mm thick Ready mix Cement Plaster work on faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for 5mm thick Ready mix Cement Plaster work on faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified.
M&L three coats of white wash on newly plastered surfaces of wall including preparation of surfaces, complete all as specified and directed.
M&L three coats of white wash on newly plastered surfaces as in ceiling including preparation of surfaces, complete all as specified and directed.
M&L for preparation of new plaster surfaces and applying two coats of cement base paint over alkali resistence primer on wall complete all as specified and directed.
M&L for broken stone or boulders hardcore of gauge n. exc. 63 mm, deposited, spread and levelled in layers n. exc. 15cm thick, watered and rammed to a true surface, complete all as specified and directed.
M&L for 75mm thick cement concrete type D-2 1:4:8 (40mm graded crushed stone aggragate) as in sub base of floor, complete all as specified and directed.
M&L for sand filling 75mm thick under floors or in foundations including watering as required complete all as specified and directed.
M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in levelling course, complete all as specified and directed.
M&L for non skid coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.11 sqm but n. exc. 0.18 sqm, as in floors set and jointed in neat cement slurry and pointed in coloured cement over and including 15mm thick screed/bedding layer in CM 1:6, complete all as specified and directed.
M&L for glazed coloured ceramic tiles of size 450x350x7mm thick as on vertical surfaces such as skilting/dado over and including 10mm thick rendering in CM 1:4, complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed.
S&F 3mm thick steel glass ordinary quality and glazing with oil putty in squares area not exceeding 0.5 Sqm in each pane, complete all as specified and directed.
M&L for preparing new surfaces of steel of any description, over 10cm width or girth not other wise described and appliying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and directed.
S&F factory made solid panel PVC door shuter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails & MS frame shall be covered with heat moulded plain colour PVC `C” channel having a PVC sheet strip of 20mm width stuck inside with solvent cement of stiles and plain colour PVC sheets for top rail,lock rail & bottom rail, on either side & as gap insert for top rail & bottom rail & panelling of plain colour PVC sheet to be fitted in the MS frame welded/Sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, in opening as per specification & drawing.
S&F Rolled mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, framework of water tanks and similiar works conforming to Fe.290.Gde-E-165 complete all as specifed and directed.
S&F for 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
M/L preparation of new wooden surfaces of any description over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of pink primer all as directed and specified.
S&F aluminium handle cast type anodized 150mm, complete all as specified and directed.
S&F 100mm butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed.
S&F aluminium anodized barrel tower bolts of extruded section of length 150mm and fixed with choromium screws plated wood series, complete all as specified and directed.
S&F 300mm size aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and directed .
S&F GI tubing 15mm bore medium grade with all fittings and fixed complete to wall, coiling or laid in floors of , complete all as specified and directed.
M&L for cutting chasses for concealed water tubing of 15mm dia and making good, complete all as specified and directed.
S&F GI tubing 20mm bore medium grade with all fittings and fixed complete to wall, ceiling or laid in floors, complete all as specified and directed.
S&F 10 Ltrs capacity PVC low level valve less flushing cistern (white) symphonic action type with all fittings such as inlet ball valve bloat and handle and flush pipe of polythene, complete all as specified and directed.
S&F vitreous china squattting pan, 'Orissa' pattern, size 580 x 440mm, white, with "P" or "S" trap, with integral foot rests excluding flushing cistern but including connection to trap, anti syphonage pipe etc. complete all as specified and directed.
S&F 32mm dia flush pipe of polyethylene of low or high density of PVC for low level cistern etc complete all as specified and directed.
S&F PVC connection 15mm dia, 450mm long with brass coupling/unions on both ends suitable for flushing cistern and WHB, complete all as specified and directed.
S&F fancy type, chromium plated, long body, bib taps, 15mm bore with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F angle valve cast copper alloy C.P 15mm bore screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipes or for union complete all as directed and specified.
S&F vitreous china wash hand basin with stand white flat back of size 550x400mm including cutting for and pinning in ends of brackets, PVC flexible waste pipe 32mm dia, brass chromium plated waste fittings etc complete all as directed and spcified.
Plain cement concrete M-10, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 75mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified & directed. Note:- The unit rate include for use of form work (straight or curved).
S&F PVC water tanks 500 ltr cap rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as directed and spcified.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as directed and spcified.
M&L RCC M-25 (design mix) using 20mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as spcified.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as spcified.
M&L RCC M-25 (design mix) using 20mm graded crushed stone aggregate as in Columns, pillars, piers, posts and struts, complete all as specified.
Form work to soffits of suspended slab such as roof slabs, floor slabs and similar work; n. exc 200mm thick(horizontal or sloping) complete all as specified and directed
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders bressummers, lintels, cantilvers, shelves including sup-ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed
Form work to edges of concrete flats, floor and roofs n. exc 20 cm wide horizontal or sloping and similar work exc 10cm but n exc 20cm wide, complete all as specified and directed
Mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooking for columns hooking ends and binding with and for and including MS wire (annealed) not less than 0.9mm dia.
M&L, mild steel bars 5 mm dia and over upto and including 10 mm dia in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality confirming to TMT bars, complete all as specified and directed.
M&L for RCC M-25 (Design Mix) using 20mm graded aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies deck slabs and in shelves and the like all complete all as specified and directed.
M&L RCC M-25 (Design Mix) using 20mm graded crushed stone aggregate as in beams, Cantilivers, bressummers, lintels over 1.5 mtr span, complete all as specified and directed
M&L for cement concrete (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches complete all as specified and directed
S&F 75mm bore dia PVC (SWR) bends, complete all as specified and directed
M&L PVC (SWR) 75mm floor trap with grating including jointing to waste pipe fixed in solvent cement complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches complete all as specified.
S&F PVC 75mm (SWR) junction single (single T) equal or unequal with access door complete as specified.
S&F PVC 110mm (SWR) junction single (single T) equal or unequal with access door complete as specified.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed
S&F 110mm PVC (SWR) vent cowl complete all as specified and directed
S&F vitreous china urinal, half stall type, white (back wall type) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe. (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe complete all as specified and directed
S&F 32mm dia PVC waste pipe for WHB and Urinal with union complete all as specified and directed.
S&F CP soap dish fixed to wall with suitable rawl plug complete all as specified and directed. Make:- Jaquar Cat Part No AKP-35731P or Prayag Cat Part No BA - 25 or in equivalent as approved.
S&F 20mm dia brass CP towel rail 600mm complete all as specified and directed Make:- Jaguar Cat. No. 7781 or in equivalent as approved.
S&F urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (minimum weight 60 gms) complete all are specified and directed.
S&F 20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipeand fixed. (Minimumweight 15mm-142gms/2 0 m m - 2 1 0 g m s . /25mm-455gms/ 40mm- 690 gms) ®
M&L for APP polymeric water proofing membrane minimum 3mm thick and weighting not less than 3.6 kg / sqm of black finished reinforced with non woven polyster matt, with fusable finish laid over compatable bitumen primer at the rate of 0.35 ltr/Sqm torching overlaps with a propane or abutane gas torch, with a over lap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufactur's instructions including preparation of surface, taking down/demolition of any type of roof treatment over and including 15mm thick cement scrred bed in CM 1:4 complete all as specified and directed.
M&L 20mm gun metal globe of gate valve with iron wheel head, screwed both ends of size complete all as specified and directed.
S&F 15mm dia, pillar taps, cast copper alloy capstain heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F shower rose fancy type bass chromium plated 125mm heavy duty pattern with swivel joints type screwed for 15mm bore including jointing to pipe or unions complete all as specifed and directed.
M&L PCC 1:3;6 type C-2 using 40mm graded crushed stone aggregate as in concrete bed to drain pipe including packing under haunching against the side of pipe after they are laid and tested for 150 mm dia bore pipe all as specified and directed.
M&L 150mm bore dia salt glazed stone ware drain pipe laid and tested in trenches complete all as specified and directed.
Providing, precast cement concrete Type B1 1:2:4 (20mm graded crushed stone aggregate set in Cement Mortar 1:4 as in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and as directed.
M&L cutting into existing manholes for connecting new drains/pipes of dia 150mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed.
M&L for machine pressed precast concrete interlocking payer block any shape and size confirming to IS -15658-2006 of 60mm thickness (M-35 Grade) with grey cement and no pigment all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in CM 1:4, complete all as specified and directed.
Extra for forming fair finished drain of channel 30cm inner girth in cement concrete using extra cement including forms, moulds itred 5 stopped ends etc
Add or deduct for each 25mm girth or part thereof over or under 30 cm girth
Excavation over areas n.exc 1.50m deep and getting out in soft/loose soil complete all as specified and directed.
All as per the description of srl Item No. 89 above additional 1.5 m or part thereof in depth beyond first 1.5 m complete all as specified and directed.
M&L for loose filling with stone aggregates of guage 40 to 80mm in soakage pits, soakage wells complete all as specified and directed.
M&L for gravel/moorum fillings in floors or pavings spread and levelled in layers not exc 15cm thick, watered and rammed to true surface complete all as specified and directed.
M&L for sand filling (200mm thick) under floors or in foundations including watering and consolidation all as specified and directed.
M&L for drilling 250mm dia bore hole by DTH cum Rotary at any depth below the ground level in any kind of rock/soil up to 40m depth including disposal of surplus soil to a distance not exc. 50 mtr away complete all as specified and directed.
S&F self preforated unplasticised PVC pipes 250mm dia of pressure rating 10 Kg/Sqcm fixed complete to wall or ceiling or in floors complete all as specified and directed.
E/M Portion:- M&L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories,GI metal flush box of 1.60mm thick suitable for modular/conventional switches/sockets/fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete for the followings :-
One light point controlled by one, one way switch 06 Amps.
One Exhaust fan point controlled by one, one way switch 06 Amps.
One 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
All as per the description srl item No 96 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 16 Amps socket outlet point on independent board with 1.5 Sqmm nominal cross sectional area copper conductor cable as continuous earth wire.
S&F switch piano flush type 5/6 Amps single pole one way 230 Volts, complete all as specified and directed.
S&F switch piano flush type 15/16 A single pole one way 230 Volts, complete all as specified and directed.
S&F socket Outlet 2 in 1, 3 pin 5 Amps flush type 230 Volt, complete all as specified and directed.
S&F Socket Outlet 2 in 1 3/6 pin 5and15 Amp flush type 230 Volts, complete all as specified and directed.
S&F Sheet metal enclosure DB 4 way, single pole and neutral with 200 Amps rated bus bar, 230 volts, glazed, double door type, IP-43, including connecting all connections of wire to MCBs with proper lugs & arrangements, making good to the disturbed surface, complete all as specified and directed.
S&F MCB DP 32 Amp, 240 Volts, AC of breaking capacity 10 KA, 'B' curve complete all as specified and directed.
S&F MCB SP 240 Volts, AC 6 to 32 Amps, breaking capacity 10 KA, 'B' curve complete all as specified and directed.
S&F wall mounted LED batten with polycarbonate housing and initigarated electronic drive 18/20 Watt fixture 4 feet provided for efficient heat dissipation with policorbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in replacement surface and wall mounted LED batten 10 watt 2 feet long extruded aluminium housing provided for efficient heat dessipation with polycarbonate diffusser and integrated electronic drive, pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete all as specified and directed.
S&F of energy efficient wall mounted LED bulk head luminaire of polycarbonate housing and enclosed with acrylic diffuser 10 watt , 230 volt, AC, IP-65 protection complete all as specified and directed.
S&F exhaust fan 300 mm sweep, steel body, 230V, AC, heavy duty with louver shutter including cutting of hole at wall complete incl connection complete all as specified and directed.
S&F of ceiling rose 6 Amp 3 terminal incl connection complete all as specified and directed.
M&L for earthing complete with galvanised mild steel earth plate electrode 60cm x 60cm x 6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed.
Supply and laying or fixing or passing through pipe 1100V grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sqmm 2 core nominal cross section in service connection complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and not exc 1.5 Mtr deep in soft soil & getting out including levelling of bottom surface to required level complete all as specified and directed.
Sand cushioning to under ground cable with a layer of sand 8 cm before laying the cable and 15cm after laying the cable (10 cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed.
Sub class ‘B bricks, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and as directed
Removing excavated material /soil from site to a distance not exc 50mtr and depositing where directed at a level not exc 1.5mtr above the starting point complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
M&L for GI pipe 40mm, light grade with clamps made out of MS flat 40 x 5mm thick, fix on pole/wall complete all as specified and directed.
M&L for making hole 80mm dia below the road in by drilling machine or hand drill without damaging road for inserting pipe 40mm dia for drawing of cable, complete all as specified and directed.
M&L for cutting of existing GI pipe line 25mm dia including threading for inserting tee / nipples etc for new pipe connection as required, complete all as specified and directed.
Supply & Laying GI pipe 20mm dia bore, medium grade ISI marked including all fittings complete all as specified and directed.
S&F heavy duty brass/gun metal ball valve, 20mm bore with handle head, screwed both ends for iron pipe, ISI Marked complete all as specified and directed.
VEDIT ENTERPRISES
ASHUTOSH BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .