Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹18.1 LAccepted-AOC | L-1 | Accepted-AOC CWC-I decided to accept the revised L-1 offer of M/s Bandhu Engineers, Kanpur at Rs. 18,06,875.00 and to place work order for execution of the subject work as per the condition of the T.E. | |
| 2 | L-2₹19.4 L+₹1.4 L (7.54%)Rejected-Finance MN 34 VINUAPUR INDRA NAGAR KANPUR 208026 | KANPUR | KANPUR | UTTAR PRADESH | 208026 | L-2 | Rejected-Finance Rate quoted by the firm is Rs. 19,43,075.00 which is at the rate of -4.71 percent below the estimated amount. | |
| 3 | L-3₹19.9 L+₹1.9 L (10.4%)Rejected-Finance 34 VINAVAPUR INDRA NAGAR KANPUR 208026 | KANPUR | KANPUR | UTTAR PRADESH | 208026 | L-3 | Rejected-Finance Rate quoted by the firm is Rs. 19,94,825.00 which is at the rate of -2.18 percent below the estimated amount. | |
| 4 | Rejected-Technical PLOT NO 3528 AWAS VIKAS NO 3 PANKTI KALYANPUR ROAD KANPUR 208017 | KANPUR | KANPUR | UTTAR PRADESH | 208017 | - | Rejected-Technical CWC I decided not to open Price bid of M/s Acchyut Trading Co. | |
| 5 | Rejected-Technical | - | Rejected-Technical CWC I decided not to open Price bid of M/s Kanhaya Electric Works |
Tender Value
₹20.4 L
EMD Value
₹40,800
Closing Date
24 Aug 2023, 5:00 pmClosed
Executive Director
Ordnance Factory Kalpi Road Kanpur-208009
Strengthening of power supply and repairing of wiring of bldg. no. 1 (AWEIL HQ) at OFC, Kanpur.
2023_AWEIL_164087_1
OFC/EOC/11/RF/2023-24
Open Tender
Electrical Works
Item Rate
180 days
Ordnance Factory Kanpur
All Contractors including Contractors who have registered with Ordnance Factory Kanpur have to download tender documents and upload the same duly signed and sealed.
2 documents required · 2 mandatory
₹0
₹40,800
Yes
2 Nov 2023
11 Aug 2023
28 Aug 2023
11 Aug 2023
24 Aug 2023
11 Aug 2023
Amount
Material & Labour excavating in trenches , not exceeding 1.5 mtr. Wide and not exceeding 1.5 mtr. in depth; for cable trench and getting out in soft soil as required and directed by EIC.
Material & Labour for necessary excavation work in soft soil for each additional 1.5m or part thereof in depth beyond the first 1.5 mtr and getting out in soft soil as directed by EIC.
Material & Labour for returning, filling in, including, spreading, levelling, watering and well ramming in layers not exc 25 cm. in soft soil.
Material & Labour for demolition concrete of any description and in any position not otherwise specifically provided for cement concrete (unreinforced)
Material & labour for cement concrete type B2 1:2:4 (40mm graded aggregate)
M & L for cutting chases in brick wall for concealed conduit wiring suitable for 25 or 32mm conduit , pinning in, making good to facings and pointing in cement mortar 1:3 to ends or edges of landings, steps, cils,sunshades,shelves, lintels etc. exceeding 10 cm but not exceeding 20 cm girth .
Supply and fixing of Bands,strips,support,frames including nut & bolts for fixing wall/floor mounted LT panel, MCB DB or similar articles conforming to FE-290GDE E -165.
Material & Labour for GI Pipe 25 MM dia light grade duty for watering in earthing system as required and directed by EIC. (Make-JINDAL,BHUSAN,TATA)
Material & Labour for GI Pipe 80 MM dia MEDIUM GRADE grade duty for protection of cable as required and directed by EIC.(Make-JINDAL,BHUSAN,TATA)
Material and labour for wiring of circuit for Building security light fitting with the following sizes of FRLS PVC insulated copper conductor, single core cable in PVC conduit (HMS GRADE) , 25mm dia. (ISI Marked) ( Make :- AKG, POLYTUBE, ASSOCIATE) on pillars or any other places .Cable size 2 x 2.5 Sq.mm + 1 x 1.5 Sq.mm earth wire including all materials and fixing accessories. (Make-FINOLEX, POLYCAB, HAVELLS, KEI , GRANDLAY ).
Material and labour wiring for circuit/submain circuit with earth wire with on Shed pillar or above existing false ceiling after removing the Armstrong make false ceiling tiles and then executing wiring works above the false ceiling tiles area of approximately 5 metre height, the same is to be re-installed in the same place and making good ,if any damage may occured that will be repaired/replaced by the L.O.I firm with the following sizes of FRLS PVC insulated copper conductor, single core cable in HMS grade PVC conduit on walls/roofs/or any other places .Cable size 2 x 4 Sq.mm + 1 x 2.5 Sq.mm earth wire including all materials and fixing accessories . Make of wire -FINOLEX, POLYCAB, HAVELLS, V- GUARD, KEI and Make of PVC conduit pipe :- AKG, PLAZA, ASSOCIATE.
Material and labour wiring for circuit/submain circuit with earth wire with on Shed pillars or above existing false ceiling after removing the Armstrong make false ceiling tiles and then executing wiring works above the false ceiling tiles area of approximately 5 metre height ,the same is to be re-installed in the same place and making good ,if any damage may occured that will be repaired/replaced by the L.O.I firm with the following sizes of FRLS PVC insulated copper conductor ,single core cable in steel conduit on walls/roofs/or any other places .Cable size 2 x 6.0 Sq.mm + 1 x 4.0 Sq.mm earth wire including all materials and fixing accessories . ( Make of wire - FINOLEX, POLYCAB,HAVELLS, V- GUARD,KEI ) and Make of PVC pipe :- AKG, PLAZA, ASSOCIATE.
M&L for Earthing complete with Copper earth plate electrode 60 × 60cm. × 3.15 mm thick, buried directly in ground earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less 'than 1.5 metres below normal ground level, connected to Copper earth strip size 20 x 3 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
Material & Labour for providing Earth continuity conductor 4 mm dia for loop earthing of cables, conduits, DB etc. complete.
Supply and fixing 5 amps to 32 amps rating , 240 volt, 10 KA ,"C" Curve miniature circuit breaker single pole. Make:Legrand, Hager,Siemens , INDOASIAN.
Supply and fixing 32 amps rating ,240 volt , 10 KA ,"C" Curve miniature circuit breaker single pole and neutral. Make:Legrand, Hager,Siemens , INDOASIAN.
Supply and fixing 25 to 63 amps rating , 415 volt , 10 KA ,"C" Curve miniature circuit breaker tripple pole . Make:Legrand, Hager,Siemens , INDOASIAN.
Supply and fixing 40 to 100 amps rating , 415 volt , 10 KA ,"C" Curve miniature circuit breaker tripple pole and neutral . Make:Legrand, Hager,Siemens , INDOASIAN.
M & L for laying or fixing or passing through pipe including termination on both sides for XLPE or PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade size 185 sqmm 3 & 1/2 core. Make-FINOLEX, POLYCAB, GRANDLAY, GLOSTER.
M & L for laying or fixing or passing through pipe including termination on both sides for XLPE or PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade size 95 sq.mm. & 3 & 1/2 core. Make-FINOLEX, POLYCAB, GRANDLAY, GLOSTER.
M & L for laying or fixing or passing through pipe including termination on both sides for XLPE or PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade size 50 sq.mm. & 3 & 1/2 core. Make-FINOLEX, POLYCAB, GRANDLAY, GLOSTER.
S & F of Single pole and neutral Powder coated Sheet Metal 8 Way 230 volt MCB Distribution Board double door for single pole Outgoing & facility for using SP MCB as incomer, complete with fixing arrangements. Make: Legrand, HAGER, INDOASIAN , Schnider.
S & F of Powder coated Sheet Metal 8 Way 415 volt Tripple Pole Neutral MCB Distribution Board double door for Single pole Outgoing & facility for using TP MCB as incomer, complete with fixing arrangements . ( Make:Legrand, Hager, Siemens Schnider, INDOASIAN)
M & L for PVC or XLPE insulated, armoured heavy duty electrical cable with Copper conductor, 1100 Volt grade size 16 sq.mm 4 core including termination on both sides. ( Make-FINOLEX, POLYCAB, HAVELLS, V- GUARD, KEI, GRANDLAY )
M & L for PVC or XLPE insulated, armoured heavy duty electrical cable with Copper conductor, 1100 Volt grade size 10 sq.mm 4 core including termination on both sides. ( Make-FINOLEX, POLYCAB, HAVELLS, V- GUARD, KEI, GRANDLAY )
Supply and fixing 4 way surface/recess mounting , Double door, vertical type,415 volt ,TPN MCB distribution board ,of sheet steel, dust protected , duly powder painted, inclusive of 160 amp. tinned copper bus bar ,common neutral link ,earth bar ,din bar for mounting MCBs ,with provision of 100 amp STP 36 KA MCCB as incommer ,interconnection between incommer MCCB and busbars (but without MCBs and CCBs) as required. Make:Legrand, Hager, Siemens, INDOASIAN.
Supply and fixing MCCB 3 POLE ,415VOLT,Adjustable type , thermal magnetic release 125 amp with breaking capacity 25 KA with enclosure box. ( Make:Legrand, Hager, Siemens, INDOASIAN)
Supplying and installing following size of perforated pre-painted M.S. cable trays of size 300 mm width X 50 mm depth X 1.6 mm thickness with perforation not more than 17.5%, in convenient sections, joined with connectors, supported horizontally with suitable M.S. angle including bolts & nuts, painting etc as required.
Material & Labour for Cast iron top cover for earthing pits Size minimum 12 inches x 12 inches.
Dismantaling / removing of old Panels /switching system / Distribution boxes and making good on the surface .
m/s sagar electricals
SHAKTI ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .