Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC S NO 279 1 1A PLOT NO 113 KUTWAL COLONY SASTHE WASTI LOHEGAON PUNE 411 047 | PUNE | MAHARASHTRA | 411047 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹20.7 L+₹1.9 L (10.0%)Rejected-Finance | L2 | Rejected-Finance Higher Bidder | |
| 3 | L3₹33.1 L+₹14.3 L (76.3%)Rejected-Finance | L3 | Rejected-Finance Higher Bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Eligibility Criteria Not Fulfilled |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
6 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
REPAIR MAINTENANCE OF HT NETWORK AND OTHER CONNECTED ITEM AT INS MANDOVI UNDER GE P NAVY MANDOVI
2021_MES_464440_1
85454/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE (P) NAVY MANDOVI
₹39,000
Yes
1 Dec 2021
2 Aug 2021
8 Sept 2021
2 Aug 2021
6 Sept 2021
23 Aug 2021
60 days
Amount
Excavation in trenches n.exc 1.5m wide & n.exc 1.5m in depth for laying & removing of cable any sizes and getting out in soft disintegreted rock/ laterite rock all as specified and as directed.
Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata all as specified and as directed.
Removing excavated disintegrated rock soil to a distance n.exc 50m, depositing where directed at a level n.exc 1.5m above the starting point all as specified and as directed.
Supply and Lay dry river sand /m -sand in trenches for cable protection all as specified and as directed. Note : Punned thickness only shall be measured & paid
Supply and lay un-reinforced precast concrete ISI marked cable covers, class HVP , type- I with peak, size 300mm x 180mm x 40mm, all as specified and as directed.
Supply and fix in trench/on wall in repairs GI tubing light grade for road crossing and cable protection of the following sizes
(a) 80 mm dia
(b) 100 mm dia
M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for pole and stay foundation all as specified and as directed.
M & L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate including use and waste of form work for pole coping/ any description all as specified and as directed.
M & L for graded coarse aggregate (broken stone or boulders) of size 40 mm in sub - station yard for laying/spreading all as directed and as specified.
Dismantling old and unserviceable RCC poles any type including breaking cement concrete complete, supply and errection of new prestressed concrete pole, 11.0 metres long, 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 complete all as directed and as specified. Note : Earth work and PCC foundation shall be measured and paid separately.
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6.0 mm thick as per IS 3043 of 1987 buried directly in to the ground ( earthpit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to the galvanised earth lead by means of bolts , nuts check nuts and washers of galvanized iron or steel using GI strip 32 x 6 mm as earthing lead as shown in electric plate No -5 of SSR- Part-1 connected to earth test point all as specified or indicated including testing on completion and necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1 :3:6 type C-1 using 20 mm graded stone aggregate, pit, funnel, 15 mm dia meduim grade watering pipe, 40 mm dia GI medium grade earth lead protection pipe, CI frame and cover , wire copper lugs etc mesh, charcoal and common salt in alternate layer complete all as specified and as directed. Note : GI earth wire upto 7.5 RM is included in the unit rate quoted.
Dismantling of existing old unserviceable ACSR of any size from any description,material and labour for providing new ACSR including stringing through existing RCC poles,fixing insulators,jumpers with polythene pipe,aluminium binding wire etc complete of different parts all as specified and as directed Notes:- (i) Rates for new aluminium cable terminal lugs are included in unit quoted rate (ii) ACSR conductors weasel/mink type shall be provided as per site requirement and as directed by Engineer in charge
S & F Galvanized Iron cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length bent to any shape drilling holes, fixed on poles or jointed by means of elect welding complete including painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surfaces including taking down / dismantling the old items complete all as specified and as directed.
Dismantling of existing old unserviceable earth wire and cradle guard of any size form the position, material and labour for providing new GI wire 4 mm dia (8 SWG) on poles to continuous earth wire and cradle guard etc, all as specified and as directed.
Dismantling old unserviceable stay assy complete, material and labour for new stay assembly complete with 20 mm dia stay rod with accessories shown in electric plate No 01 including stay clamp, (loop insulator, stay wire, excavation and concrete measured seperately) complete all as specified and as directed.
S&F for Galvanised Stay wire of size 7/4 mm including dismantling old wire all as specified and as directed.
S & F in repairs for loop insulator Vitreous Porcelian white or brown of size 90 X 140 mm clearance hole 25.5 mm all as specified and as directed.
S & F in repairs Disc type porcelain vitreous, brown or white insulator suitable for 11 KV HT working Pressure of size 145 mm height, 255 mm dia , including one galvanized mild steel spindle, two galvanized iron washer and one GI nut complete all as specified and as directed.
S & F in repairs Pin type porcelain vitreous,brown of white insulator suitable for 11 KV HT of working pressure of size 150mm height, 150mm dia, including one galvanised mild steel spindle, two galvanished iron washer and one GI nut complete all as specified and as directed.
S & F in repairs Pin type porcelain vitreous,brown of white insulator to suit 1100 Volt working pressure of size 100 mm height, 65mm dia, including one galvanised mild steel spindle, two galvanized iron washer and one GI nut complete all as specified and as directed.
S & F in repairs shackle type porcelain vitreous brown or white 1100 Volt of size, 115 mm dia and 100mm height including GI strap of size of 31 x 5 mm insulator bolt of 14 mm dia, nuts and washers for working pressure 1100 V complete all as specified and as directed.
S & F in repairs including testing of swing out explusion fuse isolated assembly with fuse carrier out door type 11 KV supply 200 Amp ( DO Fuse ) all as specified and as directed.
S & F transmission class type droup out fuses 11000 volts rating 25-50 amps,outdoor type complete all as specified and as directed.
Supply & Replacement of switch air break gang operated outdoor type (conforming to IS specifications) 11 KV, 200 Amps capacity triple pole mechanically operated suitable for operation from ground level and for vertical mounting complete with HT insulator 12 Nos, channel, GI pipe light grade/ operating rod with pad lock arrangement and outdoor drop-out expulsion fuse assembly with fuse carrier fitting all as specified and as directed .
S & F in repairs lightning arresters expulsion type complete with all fittings transmission class, discharge capacity 65 kilo amps, suitable for 11 KV all as specified and as directed.
Supply and fix cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 sqmm all as specified and as directed.
Supply and fix cable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 sqmm all as specified and as directed.
Supply & Lay , testing and commissioning XLPE cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 95 sqmm laid in trenches / floor / duct / fixed on poles / through GI tubing in different locations / areas including taking out old HT cable complete all as specified and as directed. Note : Old retrieved unsv HT cable shall be deposited in MES Store Yard by the Contractor
S & F in repairs post insulator suitable for 11 KV HT working pressure in GOD / DO arrangements of any description all as specified and as directed.
Repairing / Servicing the Air break isolating switch HT 11 KV 200/400 Amps by replacing the defective major spares including provision of minor bolts nuts etc all as specified and as directed. Note :- Major spare shall be measured & paid seperately under relevant item of Sch'A' item No. 31
Supply only 11 KV Airbreak switch spares all as specified and as directed.
(a) Male contact/moving Contact Blade
(b) Female contact/Fix Contact Jaw
(c) Tinned copper Flexible jumper 200A/400 A
(d) MS jumper carrier
(e) Back Connector plate
(f) Petroleum Jelly
Supply only All aluminium conductor for binding purpose of not less than 0.9mm dia for tightening the conductors on poles complete all as specified and as directed.
Taking out / Draining out of any condition of insulating oil from transformers of any capacity carefully and kept fully secured in seal tight containers complete all as specified and as directed. (Existing good/old Oil shall be reused/refilling after necessary filteration & dehydration) Note : - 1. Filteration & dehydration work shall be measured and paid separately. 2. A separate container/containers will be used for store to insulating oil separately for each transformer which to be re- used.
Draining out existing transformer oil from transformer and after draining out the oil flush out the bottom of the transformer with fresh transformer oil and after flushing out of bottom supplying and filling new transformer oil EHV grade after filtration attains BDV upto 50 KV for transformer 11 KV/433 V complete all as specified and as directed.
M & L for PVC sleeves suitable for LT / HT ACSR conductor / jumper in any type in R Y B Colours superior quality inserted over the ACSR all as specified and as directed.
M & L for preparation of old cement coated surface, cleaning the surface of the RCC pole (HT) 11 m long in 1 / 2 / 4 pole structures above the ground level including coping area with 2 coats of ACC exterior Emulsion paint over a coat of cement primer after preparation of surface including 12 cm black paint around the pole numbers/letters in white columns all as specified and as directed.
S & F in replacement Breather unit with superior quality blue colour silica jel, to maintain the exact value of grade for transformer of capacity 100 KVA to 150 KVA, including taking down unserviceable complete all as specified and as directed.
All as per item No 37 here in before, but for 200 KVA to 250 KVA Transformer all as specified and as directed.
All as per item No 37 here in before, but for 315 to 400 KVA Transformer all as specified and as directed.
S & F in repairs HV insulator with studs nut & washers suitable for 11 KV/433V HV side of transformer 100 KVA to 150 KVA all as specified and as directed.
All as per item No 40 here in before, but for 200 KVA to 250 KVA Transformer all as specified and as directed.
All as per item No 40 here in before, but for 315 to 400 KVA Transformer all as specified and as directed.
S&F in repairs LV insulator with studs nut & washers suitable for11 KV/433V LV side of transformer of Capacity 100 KVA to 150 KVA all as specified and as directed.
All as per item No 43 here in before, but for 200 KVA to 250 KVA Transformer all as specified and as directed.
All as per item No 43 here in before, but for 315 to 400 KVA Transformer all as specified and as directed.
Supply and fill new silica jel, superior quality in the breather unit of transformer incl taking out the old unserviceable one all as specified and as directed.
Taking out the existing serviceable Post / disc / pin insulator of 11 KV capacity carefully and re-fixing the same in the new cross arms / structure incl replacement of new hardware such as GI spindle, nut, bolt and washers complete all as specified and as directed.
Taking out the old HT 11 KV UG serviceable cable of 3 core 95 Sq mm from trenches / floors/ walls and relaying / diversion / jointing the same in the same trenches as directed and connecting all as specified and as directed. Note: Earth work is deemed to included in quoted rates
M&L for anti-climbing device; spike type fabricated out of MS bar ( round'squar and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole HT/LT all as specified and as directed.
M&L for Danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT,25X20X20mm size all as specified and as directed.
S & F in repairs HT bushing 11 KV porcelain insulator for transformer capacity upto 100 to 150 KVA all as specified and as directed.
All as per Item No. 51 here in before, but for transformer cap 200 to 250 KVA all as specified and as directed.
All as per Item No. 51 here in before, but for transformer cap 315 to 400 KVA all as specified and as directed.
S & F in repairs LT bushing porcelain insulator in transformer 11KV/440V Cap upto 100 to 150 KVA all as specified and as directed.
All as per item No.54 here in before, but for transformer cap 200 KVA to 250 KVA all as specified and as directed.
All as per item No.54 here in before, but for transformer cap 315 KVA to 400 KVA all as specified and as directed.
S & F in repairs brass studs with nuts,washers for HT bushing for 11 KV transformer upto 100 to 250 KVA Capacity all as specified and as directed.
All as per item No.57 here in before, but for from 315 KVA to 400 KVA all as specified and as directed.
S & F in repairs brass studs with nuts,washer for LT bushing for 11KV/440 V transformer Cap upto 100 to 250 KVA all as specified and as directed.
All as per item No.59 here in before, but for transformer Capacity 315 KVA to 400 KVA all as specified and as directed.
Supply and replace in repairs of fabricated transformer box lid (Cable box) suitable for HT/LT side of transformer with necessary gasket,nut, bolts, washers etc and including painting two coats as per existing painting for transformer, capacity upto 315 KVA all as specified and as directed.
All as per item No.61 here inbefore, but for transformer Cap 250KVA to 400 KVA all as specified and as directed.
S & F repairs Explosion vent diaphram of transformer all as specified and as directed.
M&L for Minor welding work/patch work for any type and any capacity of transformer including drain out and refilling oil and painting with two coats of synthetic enamel paint to all surfaces of the transformer over a coat of primer to welding/patch work portions for transformer of capacity 100 to 400 KVA all as specified and as directed.
M & L for painting of old transformer outside of body completely, including cleaning the body scrubbing thoroughly and applying one coat of synthetic enamel existing shade of paint to transformer of capacity 100 KVA to 250 KVA all as specified and as directed.
M&L for dismantling of U/S capacitor bank any type any capacity from any site after disconnecting electric connections and depositing at MES store Yard including removal from site and making good of disturbed surface all as specified and as directed.
(a) MCCB TP 100 Amps (adjustable type), 25 KA Icu=Ics=100% 01 No (b) Power capacitor,2 X 10 KVAR ,2 X 5 KVAR, 2 X 3 KVAR ,2 X 2 KVAR 8 stage MPP type heavy duty capacitor bank consisting of suitable Number of switching sequences 3 phase 415 volts suitable for 10 % over voltage & 30 % over current having losses less than 0.5 W/KVAR with in built discharge resistors with MCB 3 pole 32 amp for each stage control (c) Contactors having current limiting resistors suitable for capacitor switching of variable KVAR correction of specification as approved by GE (d) Microprocessor based intelligent APFC relay for controlling variable correction of KVAR (e) Indication lamp RYB ( LED type) with toggle switch -03 set (f) Internal wiring of panel with stranded copper cable of suitable size. (g) Push button for manual switching of capacitor.
M & L for lugs (3 P + N) on LT cable to connecting on LT side bushing by removing old lugs fixed on LT busing complete for 300 to 400 Sqmm 3.5 core cable all as specified and as directed.
M&L for taking out old wornout earthing strip 32 X 6mm from body and neutral of transformer any capacity after disconnecting power supply from GOD. Fixing new galvanised iron earthing strip 32 x 6mm along with suitable size of nuts,bolt and washer upto test point all as specified and as directed.
Supply and fixing in repair Temp guage 0-300 degree centigrade all as specified and as directed.
M & L for graded coarse aggregate (broken stone or boulders) of size 12.5 mm in sub - station yard for laying/spreading all as directed and as specified.
Trimming and pruning of complete tree upto a safe distance from the over head line between two poles including cutting branches of size not exceeded 80mm dia complete all as specified and as directed. Notes:- (1) The necessary man power,tool & plant,cutting tools and JCB required for cutting/pruning of branches is deemed to include in the rate quoted for the job (2) Proper shut down will be taken by the authority rep only (3) One job will be considered for trimming/pruning of tree complete one span between two poles
Taking down existing old unsv LT panel and supply, fabricating, installation, commissioning, testing and electrically connected CPRI approved manufacturer LT panel out door cubical type, Double door, made of 3.15 mm thick CRCA sheet steel on angle iron frame 50mm x 50mm x 6 mm of size 1.0m x1.0 m x 0.40 m with removable hinged doors on both side, locking arrangement, vermin proof, painted with 2 coats of synthetic enamel paint over a coat of red oxide (internal& external surface) with heat shrinkable sleeves on Copper bus bar 400 Amp capacity - 04 Nos for distribution, complete wiring with thimbles and other accessories using crimping tool including foundation for fixing over PCC (1:2:4) type B-1 using 20mm graded stone aggregate foundation complete all as specified and as directed.comprising the following :-
Notes: All MCCB must have the provision of load setting. as (i) MCCB 400 Amps 36 KA, 4 pole 415 volts , 50 C/S with Link - 01 Nos Outgoing (ii) MCCB 200 Amps 25 KA, 4 pole 415 volts , 50 C/S with Link- 03 Nos (iii) MCCB 125 Amps 25 KA, 4 pole 415 volts , 50 C/S with Link - 01 Nos (iv) Indicating lamps, LED type, 230VAC - 3Nos. (v) Digital Voltmeter , 3Phase -01 Nos(vi) Digital Ammeter 3Phase - 1 Nos (vii) CT coils - 3 Nos.
Servicing and repairing /carrying out maintenance of 11 KV/ 440 V transformer including the following works for transformer upto 400 KVA capacity as details here under including the following complete all as specified and directed by Engr in Charge. (a)Removing from platform and disconnecting electrical connection from HT and LT side including transporting the transformer to workshop including loading unloading complete or to be repaired at site. (b)Dismantling the transformer, drain out transformer oil, lift the top cover by opening all nuts and bolt with the help of T&P chain pully tepoy at site or in workshop as required for carrying out the following repair replacement works :- (i) Replacing HV/LV Insulator with studs nuts & washer (Ref Item No 40 to 45) (ii)Replacing HT & LT side bushing porcelain insulator.(Ref Item No 51 to 56) (iii)Brass Studs with nuts and washer of HT bushing (Ref Item No 57 & 58) (iv)Brass Studs with nuts, washer of LT bushing (Ref Item No 59 & 60) (c) Re-assembling all dismantled parts including provision of new gasket, nuts, bolts, washers etc, refilling with transformer oil and transporting back to original location including electrical connection, testing and commissioning complete all as directed.
Notes : (i) Oil filteration, supply of new oil will be measured and paid separately. (ii) All petty parts including nuts, bolts, gasket , minor welding , oil for cleaning, greasing etc any other minor works and material(other than listed separately in tender) required for re-assembling all dismantled parts are deemed to be included in the rate quoted by the contractor. (iii) The rate for transport and lifting of transformer by craneshall be deemed to be included in quoted rates.
Prabha Electricals and Communications
MARINE ELECTRICAL AGENCIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .