Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹96,902
Closing Date
24 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Nasirabad
GE Nasirabad Military Engineer Services Pin 305 601 Rajasthan
SPL REPAIR TO BLOCK NO 194/1-08 (MD ACCN) OF 173(I) FD WKSP COY (PINAKA) AT NASIRABAD MILITARY STATION
2025_MES_741961_1
8609/E8
Open Tender
Civil Works
Item Rate
180 days
GE Nasirabad
As per Tender Documents
6 documents required · 6 mandatory
₹500
Yes
GE NASIRABAD
₹96,902
Yes
28 Nov 2025
28 Nov 2025
26 Dec 2025
28 Nov 2025
24 Dec 2025
12 Dec 2025
28 Nov 2025 - 12 Dec 2025
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling floor, hearth or wall tiles, including cement mortar, removing serviceable tiles from site & rubbish off the premises complete all as specified and directed.
Taking down cement or cement lime plaster or stone / brick wall, ceiling including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Demolition of brick work or stone masonary built in cement mortar etc complete all as specified and directed.
All as per item No. 08 here in before but except stone complete all as specified and directed.
M&L for rendering in cement mortar (1:6), 15mm thick on other than fair faces of brick work / stone masonary surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L 5mm thick rendering in cement mortar in CM (1:3) on ceiling finished even and smooth without using extra cement complete all as specified and directed.
M&L 15mm thick rendering in cement mortar (1:4) mixed with water proofing compound, on other than fair faces of brick / stone masonary surfaces, finished even and smooth without using extra cement, complete all as specified and directed (WPC measured and paid separately)
M&L 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in floors complete all as specified and directed.
M&L non skid ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.18 Sqm but not exc 0.36 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bedding in cement mortar 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 7 to 8mm thick in vertcial surfaces of size exceeding 0.11 Sqm but not excceding 0.18 Sqm set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick screed plaster in cement mortar 1:4 complete all as specified and directed.
M&L RCC, type B-1 (1:2:4) using 20mm graded aggregate in, slab supported on wall, walls beams and columns in floors, roof landings complete all as specified and directed.
M&L TMT bars of 6 to 8mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9 mm dia complete all as specified and directed.
S&F Pressed steel door frame of size 105 x 60mm for doors with one or more rebates incl necessary fixing lugs hinges, lock strike plate,hold fasts etc. complete all as specified. The rates include for one shop coat of priming and filling PCC 1:3:6. complete all as specified and directed.
S&F Second class HW, plain, solid, straight chowkhats & frames, wrought, framed, rebated on the solid, rounded or chamfered, put together glue pinned at joints complete all as specified and directed.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
Taking down old unserviceable 15mm GI tubing, fittings and connections and removing from site or keeping aside for refixing complete all as specified and directed.
S&F in repair 15mm bore stop valves (concealed) fancy type, chromium plated cast copper alloy,with long shank and cap screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions fixed complete all as specified and directed
Supply only liquid water proofing compound of approved quality and make confirming to IS complete all as specified and directed.
S&F in repairs PVC (SWR) gully trap 125/110mm, including fittings and jointing to waste pipe fixed in cement concrete type (1:2:4) complete all as specified and directed.
Extra for fair finishes drain or channel 30cm and over in girth in cement concrete using extra cement including forming mounds metred /stopped ends etc complete all as specified and directed.
Per 1000 Nos
M&L for SWG drain pipe grade 'A' 150mm dia laid in trenches incl jointing in CM 1:3 complete all as specified and directed.
M&L for preparation of new or previously untreated wood and wood based surfaces of any description not otherwise descriped over 10cm width girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and apply two coats of oil bound distemper over a coat of 1mm thick wall putty complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed
M&L for newly plastered surfaces two coats of cement base paint over one coat of cement based primer on plastered/ concrete surfaces of walls including preparation of surfaces complete all as specified and directed.
S&F 1mm thick stainless steel kitchen sink with drainage board with plugs, washers and waste coupling and PVC waste pipe including fixing on half brick wall or cantilever brackets(angle iron ) and connecting union overall size 915mm x 460mm, bowl size 410mm x 330mm x 160mm, fixed in repair complete all as specified and directed
S&F stainless steel plate rack made of 0.50mm thick of over all size 920mm x 785 mm x 255 mm and weight not less than 7
.00 Kg each of approved quality complete all as specified and directed..
Fabrication & fitting of cabinet / shelves & wardrobe / cupboard made out nof 18mm thick (one side decorative lamination & other side balancing lamination ) PVC sheet with piano hinges, with handles door shutters complete all as specified and directed.
Supply only 18mm thick (one side decorative lamination & other side balancing lamination sheet) solid PVC board of make : Rajshree or equivalent all as specified and approved by Accepting Officer with cement solvent adhesive for shutter / cup boards / partition wall / wall cabinet and similar work complete all as specified and directed.
Supply and fixing in repairs PVC cabinet of size 450 mm x 600 mm with mirror of good quality with shelves in bath fixed complete to walls complete all as directed. (Make : Prayag or eqvt). (Cat No. 555)
M&L for pre-cast RCC 1:2:4 type B1 using 20mm graded stone aggregrate in cover slab for manhole or similar works set in CM 1:6 complete all as specified and directed. (Note :- reinforcement shall be measured and paid separately)
M&L for mild steel TMT bar 10 mm dia and over cut to length bent to shape required including cranking bending for hooking ends and binding with and including mild steel wire ( annealed) not less than 0.9mm dia or securing with clips conforming complete all as specified and directed.
Taking down existing tar felt or of any description including cement plaster or concrete of any thickness from the roof surfaces of building including cleaning the surfaces in all respect & preparing it for further treatment & removing rubbish from site complete all as specified and directed.
Material and labour for 40mm thick (avergae consolidated thickness) PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate laid in slope as in padding, finished even and smooth on existing slope including provision of 'V' shaped groove 6mm wide and 10mm deep at 1.20 metre interval or parts thereof, both ways on top of PCC padding and filled with mastic bitumen of (1:1) proportion complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:4 mixed with water proofing compound @ 3% by weight of cement on fair faces of RCC/stone patti roof surfaces finished even & smooth without using extra cement complete all as specified and directed (WPC will be measured and paid separately).
M&L roof treatment with APP modified polymeric water proofing membrane, 2mm thick having centre core not less than 100 mircron high molecular high density polyethylene film (HMHDPE) protected on both sides with high polymeric asphaltic mix and 20 mircron HMHDPE film weight not less than 2.60 kg/ Sqm applied with bonding material using blown type bitumen primer Grade 85/25 @ 1.20 Kg/Sqm over bitumen primer conforming to IS -3384 @ 0.40 Kg /Sqm with final coat of bonding bitumen grade 85/25 @ 1.20 Kg /Sqm over APP membrane with all overlaps complete all as specified and directed
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, ceiling roses, holders, regulators, sockets etc., removing materials from site and making good disturbed surface of walls, floors etc. complete all as specified and directed.
Disconnecting unserviceable sub main wiring/service connection of any size and including conduit of any type and accessories and removing from site and making good the disturbed surfaces. complete all as specified and directed.
Taking down MCB DB's complete with MCB's/Isolator etc removing materials from site and making good disturbed surface of walls, floors etc. complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm, PVC insulated, unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit 20mm dia or higher complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc./fittings ISI marked and sunk type pressed steel anodised terminal box 1.2 mm thick with bakelite laminated sheet top cover 3 mm thick, brass screws and cup washers including 1.5 Sqmm stranded copper conductor PVC insulated green in colour as continous earth conductor connected to common earth and earth dolly with all accessories for:-
One light point/bell point controlled by one, one way switch.
One ceiling fan/exhaust fan point controlled by one, one way switch.
One three pin 5 Amp socket on same board with other switches.
All as per item No.17.00 above but in skirting over 10mm thick screeding in cement mortar 1:4 complete all as specified and directed.
One 3 pin 5 Amp socket on independent board.
One light point controlled by two Nos two way switch.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed multistranded (FRLS) copper conductor cable of size 6.00 Sqmm LT, 1100 volts grade, drawn through and including 25 mm dia or higher PVC non metallic concealed conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 6 sqmm single core multistranded copper conductor cable green colour as earth continuity conductorcomplete all as specified and directed.
S&F switch piano flush type 5 amps, single pole one way 240 volts. complete all as specified and directed.
S&F switch piano flush type 15 amps, single pole one way 240 volts. complete all as specified and directed.
S&F switch piano flush type 5 amps, single pole two way 240 volts. complete all as specified and directed.
S&F bell push piano flush type 5 Amp. complete all as specified and directed.
S&F Socket outlet 3 Pin 5/6 Amp flush type. complete all as specified and directed.
S&F socket out let 2 in 1, multipurpose 3 pin 15/16 Amp flush type ISI marked complete all as specified and directed.
S&F ceiling fan regulator electronic flush, steped (four step) 230 Volts AC complete all as specified and directed.
S&F ceiling rose surface bakelite 3 terminals 63.5 x 17 mm. complete all as specified and directed.
S&F of door bell ding dong type electric 230 volts AC, single phase complete all as specified and directed.
S&F of lamp holder PVC/polycarbonate type with back plate complete all as specified and directed.
S&F LED tube light fitting in acrylic linear tube (1x 18 watt), 230V for single LED tube light including 1 x 18 W LED retrofit bar professional CW 6500 K cover channel, bipin holders, LED power driver, connector block, etc complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable with suitable size for connection of fitting from ceiling rose complete all as specified and directed. Make Bajaj, Havells, Crompton
S&F Wall mounted decorative luminaire fitting suitalble for LED lamp B-22 base 9 watt complete all as specified and directed.
S&F LED bulk head luminaire 1x 10 W bulk, IP 65 protection complete with all accessories and including connecting up with three core copper conductor cable complete all as specified and directed.
Use of waste form work for flat fair finished surfaces of concrete to soffits of suspended slabs such as roof slab not exceeding 200mm thick complete all as specified and directed.
S&F testing and commissioning energy saving street light luminaire 35 watt LED, pressure die cast housing with epoxy powder coated with colour finish and prismatic poly carbonate coverlic cover complete with individual LED lences and complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment coloured, reflective type of approved quality including watering including 25mm thick sand filling of below the floor in foundation and vibrated with mechanical vibrator complete all as specified and directed.
All as per item No. 114.00 but with 2.5 Sqmm, for one 5 pin 5/15 Amp socket on independent board including 2.5 Sqmm stranded copper conductor (FRLS) PVC insulated green in colour as continous earth conductor connected to common earth complete all as specified and directed.
Disconnecting and taking down existing electric meter and refixing the same after repair of electric meter, connecting, testing and sealing properly and making good disturbed surface of walls etc complete all as specified and directed.
S&F of MCB distribution board single pole & neutral with 200 Amps rated E bus bar, double door IP-42 DB's, made out of sheet steel enclosure, recessed type, factory made powder coated 8 way, 240 volts suitable for housing MCB's complete all as specified and directed. Note: MCB DB and MCB SP/SPN will be of same make.
S&F of MCB distribution board TPN 4 way, 415 volts, double door, with 200 Amps rated bus bar, neutral bar with shrouds, earth bar, IP-43 made out of sheet steel enclosure, recessed type, factory made powder coated suitable for housing MCBs as incomer and outgoing complete all as specified and directed. Note: MCB DB and MCB SP/SPN will be of same make.
Supply and fixing street light bracket made of 32 mm Gl pipe, 1.2 mtr length fixed with two Nos of clamp, nut and bolts complete all as specified and directed.
Taking down existing ceiling fan, dismantling blades and refixing after cleaning incl conecting up with three core flexible cable from ceiling rose to fan complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode Ea 60cmx60cmx6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and other end of earth wire connected to main switch board and protected by galvanised iron pipe light grade 15mm bore and water p
ipe 20 mm bore Gl med grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover with handle all as specified and shown in elect plate No 3 of SSR Part-I of 2009 incl dismantling of old unsv existing earthing complete all as specified and directed.
S&F storage type water heater (Geyser) electrical operated 230 volts including connecting inlet/outlet/vent pipes, electric/earth connections, mounting bolts, nuts and carrying out testing for proper functioning for geyser of capacity 25 Itrs complete all as specified and directed.
S&F exhaust Fans AC single phase 230/240 volts of size 300 mm sweep with louver including making space/holes in wall/window for installation of exhaust fan connecting with three core flexible copper wire from ceiling rose to connector of fan complete all as specified and directed.
Supply and fix vantilation fan, steel body AC single phase, 230V of size 250 mm sweep with louver including making space/holes in wall/window for installation of exhaust fan connecting with three core flexible copper wire from ceiling rose to connector of fan complete all as specified and directed.
Supply & fixing ceiling fan 1200 mm sweep, 230 Volts, AC, 50 Hz. copper winded motor, BEE 5 star rated white colour complete with motor, blade set of three nos, down rod, canopy, shackle assy complete all as specified and directed.
Supply and laying including jointing, testing or fixing or passing through pipe, trench or duct commissioning and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volt grade size 25 sqmm, 4 core complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and directed.
S & F of MCB SP, 240 volt, 6 Amp to 30 Amp capacity, 10 KA, 'C' curve complete all as specified and directed.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
GeneralPages8609.pdf
Tender Documents • 0.98 MB
BOQ_830826.xls
BOQ • 1.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .