Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC | L1 | Accepted-AOC Quoted rates of lowest tender found reasonable hence accepted | |
| 2 | L2₹16.5 L+₹35,979.40 (2.23%)Rejected-AOC | L2 | Rejected-AOC Quoted rates are high hence rejected | |
| 3 | L3₹16.9 L+₹82,415.54 (5.12%)Rejected-AOC | L3 | Rejected-AOC Quoted rates are high hence rejected | |
| 4 | L4₹17.4 L+₹1.3 L (7.81%)Rejected-AOC | L4 | Rejected-AOC Quoted rates are high hence rejected | |
| 5 | L5₹17.7 L+₹1.6 L (10.0%)Rejected-AOC | L5 | Rejected-AOC Quoted rates are high hence rejected |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
2 Jun 2021, 6:00 pmClosed
Shri Rohan Sonkar, IDSE GE Tawang
GE TAWANG Pin- 900198 C/o 99 APO
REPAIR/ MAINTENANCE TO GI/PPR PIPE LINE, VALVES AND WATER STORAGE TANKS, CLEANING OF TANKS AND OTHER CONNECTED WORK AT 72 MVFH, 384 SUPPLY, 106 FD WKSP, 852 AT COY, 305 FD HOSP, LHOU GOMPA, APNNB AND 40 BDE UNDER GE TAWANG
2021_MES_441610_1
8419/GE/TWG OF 21-22
Open Tender
Civil Works
Item Rate
180 days
Tawang
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE Tawang
₹30,000
6 Sept 2021
10 May 2021
10 Jun 2021
10 May 2021
2 Jun 2021
24 May 2021
10 May 2021 - 17 May 2021
Amount
Excavation in trenches not exceeding 1.5m in width and 1.5m depth for taking out and laying PPR pipes and getting out in soft/loose oil all as specified and directed.
Returning filling including spreading , leveling ,watering and well ramming in layers not exceeding 25 cm all as specified and directed.
Removing excavated surplus soil not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting points in soil all as specified and directed.
Taking up GI/ PP-R pipe of undermentioned sizes tubing with all accessoreis complete all as specified and directed :-
4(a) 25mm dia 32 mm dia
4(b) 40 mm dia to 50 mm dia
4(c) 63 mm to 75mm dia
4(d) 80 mm dia
3- layer PP-R Polypropylene random copolymer) pipes of following sizes ISI marked, IS-15801 SDR 7.4 (PN 16) UV stablised and inner antimicrobial and outer UV stabilized fusion welded having thermal stability for hot & cold water supply all PP-R plain brass threaded polypropylene random fitting laid in trenches /walls/cellings or laying in floors incl fitting and fixture complete all as specified and directed :-
9(a) 25 mm dia
9(b) 32 mm dia
9(c) 40 mm dia
9(d) 50 mm dia
9(e) 63 mm dia
9(f) 75 mm dia
Supply, laying and testing of steel water tubes medium grade galvanized ,with all fitting and laid in trenches and floor etc for following sizes complete all as specified and as directed
16(a) 50 mm bore
16(b) 80 mm bore
Material and Labour for gun metal globe or gate valves of approved make with iron wheel, complying to relevant IS with latest amendments. All complete as per Specifications (According to Total Number of Building Taping point)
19(a) 20 mm bore
19(b) 25 mm bore
19(c) 40 mm bore
19(d) 50 mm bore
S&F in replacement of PPR gate Valves (brass insert) of under mentioned sizes including cutting and inserting in existing pipe or fixing in new laid pipe with required fittings and fixtures complete all as directed
24(a) 25 mm dia
24(b) 32 mm dia
24(c) 40 mm dia
24(d) 50 mm dia
24(e) 63 mm dia
24(f) 75 mm dia
Material and labour for fixing including jointing and testing of cast iron sluice valves of size as following class PN 1.6 conforming to IS : 14846 flanged ends drilled having brass spindle with cast iron whell at top complete with nuts, bolts, washer complete all as per specified and as directed.
31(a) 80 mm dia
31(b) 100 mm dia
Material and labour for brick masonary valve chamber of the following sizes including necessary excavation, PCC foundation, brick work, plastering and MS sheet cover of 6 mm thick including locking arrangement with two coats of red oxide primer and one coat of synthetic enamel paint of approved colour all as directed of the folloiwng sizes: -
34(a) 600 x 600 x 600 MM
34(b) 900 x 900 x 900 MM
M&L for PCC 1:4:8 type D2 (using 40mm graded aggregate) as in foundation filling and mass concrete etc.
M&L for PCC 1:3:6 type C1 (20mm graded aggregate) precast cement concrete block masonary with solid blocks exc. 10cm in width and setting in CM 1:4 etc complete
Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipeand fixed. (Minimum weight 20 mm - 210 gms . / 25mm-455gms/ 40mm- 690 gms) of undermentioned sizes :-
39(a) 20 mm dia
39(b) 25 mm dia
39(c) 32 mm dia
S&F in replacement of 2000 ltr capacity rotational moulded polethelene water storage tank (cylindrical vertical with closed up) of hoisted & fioxed in position.
S&F in replacement of 1000 ltr capacity rotational moulded polethelene water storage tank (cylindrical vertical with closed up) of hoisted & fioxed in position.
S&F in replacement of 750 ltr capacity rotational moulded polethelene water storage tank (cylindrical vertical with closed up) of hoisted & fioxed in position.
S&F in replacement of 500 ltr capacity rotational moulded polethelene water storage tank (cylindrical vertical with closed up) of hoisted & fioxed in position.
Disconnecting existing over head PVC water tanks , setting aside (or lowering if required) for repairs ,including cleaning and removing all scale and dirt etc from tank and from mouth of circulating pipe etc and hoisting and refixing in position including reconnection of water tanks complete of capacity exc. 250 Litres but n.exc. 500 Litres all as directed.
Disconnecting existing over head PVC water tanks , setting aside (or lowering if required) for repairs ,including cleaning and removing all scale and dirt etc from tank and from mouth of circulating pipe etc and hoisting and refixing in position including reconnection of water tanks complete of capacity exc. 500Litres but n.exc. 1000 litres all as directed.
Disconnecting existing over head PVC water tanks , setting aside (or lowering if required) for repairs ,including cleaning and removing all scale and dirt etc from tank and from mouth of circulating pipe etc and hoisting and refixing in position including reconnection of water tanks complete of capacity exc. 1000 Litres but n.exc. 2000 Litres all as directed.
M&L for cutting existing pipe making connection of PPR distribution branch with PPR main of size 16 to 40 mm bore and inserting Tee conncetion and making fusion joint etc. complete all as directed.
M&L for cutting existing pipe making connection of PPR distribution branch with PPR main of size 50 to 75 mm bore and inserting Tee conncetion and making fusion joint etc. complete all as directed.
M & L for cleaning of under ground / above ground water sump, Sedimantation tank , Raw water tanks by scraping the internal surface with steel wire brushes, pumping out water up to bottom level complete drain out removing silt / debris descaling with solution and applying two coats of lime white wash internally as directed by the Engr - in- charge, cleaning the internal surface of the tanks to the complete satisfaction and as directed by the Engr-in -charge for the following capacity 20000 Ltr to 40000 Ltr
M & L for cleaning of under ground / above ground water sump, Sedimantation tank , Raw water tanks by scraping the internal surface with steel wire brushes, pumping out water up to bottom level complete drain out removing silt / debris descaling with solution and applying two coats of lime white wash internally as directed by the Engr - in- charge, cleaning the internal surface of the tanks to the complete satisfaction and as directed by the Engr-in -charge for the following capacity 50000 Ltr to 80000 Ltr
Supply and fix Mechanical Joint, suitable for DI / CI pipe of following Size
54(a) 80 mm dia
54(b) 100mm dia
Supply and fix 'C' Clamp including nut, bolt and gasket suitable for GI, DI and CI pipe of size 150mm dia all as per direction and sample given by Engr-in-charge.
Supply and fix 'C' Clamp including nut, bolt and gasket suitable for GI, DI and CI pipe of size 100mm dia all as per direction and sample given by Engr-in-charge.
Supply and fix 'C' Clamp including nut, bolt and gasket suitable for GI, DI and CI pipe of size 80mm dia all as per direction and sample given by Engr-in-charge.
Material and labour for cutting, welding and jointing of existing GI pipe of size 50mm, 80mm, 100mm and 150mm complete all as specified and as directed.Note:-the rate of inclusive required necessary excavation.
S&F in replacement of PPR Unions (brass insert) of under mentioned sizes including cutting and inserting in existing pipe complete all as directed
61(a) 25 mm dia
61(b) 32 mm dia
61(c) 40 mm dia
61(d) 50 mm dia
61(e) 63 mm dia
61(f) 75mm dia
Laying only and testing of old serviceable and testing of steel water tubes medium grade galvanized ,with all fitting and laid in trenches and floor etc for following sizes complete all as specified and as directed
68(a) 25 mm bore
68(b) 40 mm bore
68(c) 50 mm bore
68(d) 80 mm bore
68(e) 100 mm bore
Supply and fix PPR Sockets of under mentioned sizes including cutting and inserting in existing pipe complete all as directed
74(a) 25 mm dia
74(b) 32 mm dia
74(c) 40 mm dia
74(d) 50 mm dia
74(e) 63 mm dia
74(f) 75mm dia
Supply and fix PPR elbow of under mentioned sizes including cutting and inserting in existing pipe complete all as directed
81(a) 25 mm dia
81(b) 32 mm dia
81(c) 40 mm dia
81(d) 50 mm dia
81(e) 63 mm dia
81(f) 75mm dia
Supply and fix PPR TEE of under mentioned sizes including cutting and inserting in existing pipe complete all as directed
88(a) 25 mm dia
88(b) 32 mm dia
88(c) 40 mm dia
88(d) 50 mm dia
88(e) 63 mm dia
88(f) 75mm dia
M/S KESANG CONSTRUCTION
M/S N T BROTHERS
M/ S N T ENTERPRISES
M/S RINCHIN DORJEE CONSTRUCTION
M/S TARAYANA BUILDERS
TENZIN CONSTRUCTION
T T ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .