| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹10.9 L+₹72,415 (7.15%)Rejected-Finance HATIA ROAD DANGALPARA DISTT DUMKA JHARKHAND PIN 814101 | DUMKA | DUMKA | JHARKHAND | 814101 | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹11.2 L+₹1.0 L (10.2%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹11.3 L+₹1.1 L (11.2%)Rejected-Finance | L4 | Rejected-Finance HIGH RATE | |
| 5 | L5₹11.4 L+₹1.3 L (12.7%)Rejected-Finance | L5 | Rejected-Finance HIGH RATE |
Tender Value
Refer Docs
EMD Value
₹19,500
Closing Date
22 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ABHISHEK KUMAR YADAV
AGE I AF SINGARSI
Repair Maint of submain and distribution board in technical and DSC area at AF Stn Singarsi under AGE I AF Singarsi
2022_MES_533237_1
C/8553/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I AF SINGARSI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
AGE I AF SINGARSI
₹19,500
Yes
25 Aug 2022
23 Jun 2022
25 Jul 2022
24 Jun 2022
22 Jul 2022
27 Jun 2022
Amount
M&L for replacement ofsub main wiring with 2 run of 2.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable FRLS working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC casing/caping (25mm dia) including size 2.5 sqmm (nominal cross sectional area) PVC insulated un-sheathed single core multi stranded copper conductor cable as earth continuity conductor connected to main switches/DB"S or common earth dully complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface.( NOTE :- Two runs of 4 Sqmm pvc wire, one run of 2.5 Sqmm pvc wire and one run of pvc casing caping/ PVC conduit will be measured as one unit.
M&L for replacement of sub main wiring with 2 run of 4 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable FRLS working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC casing/caping (25mm dia) including size 4.0 sqmm (nominal cross sectional area) PVC insulated un-sheathed single core multi stranded copper conductor cable as earth continuity conductor connected to main switches/DB"S or common earth dully complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface.( NOTE :- Two runs of 4 Sqmm pvc wire, one run of 2.5 Sqmm pvc wire and one run of pvc casing caping/ PVC conduit will be measured as one unit.
M&L for replacement of sub main wiring with 2 run of 6 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable FRLS working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC casing/caping (25mm dia) including size 6 sqmm (nominal cross sectional area) PVC insulated un-sheathed single core multi stranded copper conductor cable as earth continuity conductor connected to main switches/DB"S or common earth dully complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface.( NOTE :- Two runs of 6 Sqmm pvc wire, one run of 10 Sqmm pvc wire and one run of pvc casing caping/ PVC conduit will be measured as one unit)
M&L for replacement of 3 phase sub main wiring with 2 run of 16 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core multi stranded copper cable FRLS working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC conduit not less then 25 mm dia ,connected to main switches/DB"S complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface. ( NOTE :- Two runs of 16 Sqmm pvc wire, and one run of 10 sq mm with PVC conduit/PVC flexible pipe will be measured as one unit)
S & F metal clad box enclosure with socket plug top and MCB SP 20 Amps flush mounting enclosure with 2 pin and earth plug socket including taking down old US DB box any size omplete all as specified and as directed. Make - Havells or Equivallent to Legrand/Schnieder/Hager
Taking down unserviceable point wiring of any size, any type and PVC conduit/ casing capping and removing materials from site and making good the disturbed surface of wall etc complete all as specified and as directed.
M&L for point wiring for one light/fan/bell with single core PVC insulated and unsheathed stranded FRLS copper conductor cable 1100 volts grade size 1.5 Sqmm (nominal area) in and including PVC casing capping 25/20 mm width with one single core PVC insulated unsheathed 1.5 Sqmm (nominal area) stranded FRLS copper conductor as earth continuity wire and connected to earth dolly including PVC/wooden switch board on existing wall surface with 3mm thick plastic hylum sheet cover fixed with MS screws and cap washers for one light/fan point /bell point controlled by one number one way switch & making good the disturbed surface to match with existing surface/wall complete all as specified and as directed.
All as per Item No 7 here-in-before but for one 5 pin socket outlet 5 Amps on independent board with 1.5 Sqmm complete all as specified and as directed.
All as per item No 7 here-in-before but for one 5 pin socket outlet 5 Amps on the same board with other switches complete all as specified and as directed.
All as per Item No 7 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with 4 Sqmm copper cable FRLS & 2.5 Sqmm FRLS copper cable for earth continuity wire complete all as specified and as directed.
S&F for switch piano flush type 5 Amp single pole one way complete all as specified and as directed.
S&F for socket flush type 5 Amp 5 Pin complete all as specified and as directed.
S&F for switch socket combination 5 Pin 5 Amp universal complete all as specified and as directed.
S&F for switch socket combination 5 Pin, 5/15 Amp universal complete all as specified and as directed.
S & F ceiling rose, 3 phase/PVC/Polycarbonate, isolated body complete all as specified and as directed.
S&F for sheet metal enclosures for DB’s single door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 2 way without bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed. (Make:Hager,Schneider or Legrands).
S&F for sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 4 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed. (Make:Havells ,Hager,Schneider or Legrands).
S&F for sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 6 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and directed by Engr-in-charge. (Make:Havells ,Hager,Schneider or Legrands).
S&F for sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 8 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed. (Make:Havells ,Hager,Schineder or Legrands).
S&F for sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 12 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour, complete all as specified and as directed. (Make:Havells ,Hager,Schineder or Legrands).
Taking down carefully DB with MCB of any description complete all as directed by Engr-in-charge.
S&F inreplacement of sheet metal enclosures for DB’s double door suitable for mounting of TPN/MCB'S/Isolators, 415 Volt, Vertical TPN DB's 8way with built in160A rated bus bar and without TPN complete including making good the distrubed surface and matching with existing colour complete all as specified and directed by Engr-in-charge. (Make Havells /Hager/Schnieder or Legrands).
S&F inreplacement of sheet metal enclosures for DB’s double door suitable for mounting of TPN/MCB'S/Isolators, 415 Volt, Vertical TPN DB's 6way with built in160A rated bus bar and without TPN complete including making good the distrubed surface and matching with existing colour complete all as specified and directed by Engr-in-charge. (Make Havells /Hager/Schnieder or Legrands).
M & L for MCB, SP, 240V, 6 to 32 Amps and ' C ' series breaking capacity 10 KA ISI marked complete, all as specified and as directed.
M & L for MCB, SP, 240V, 40 Amps and ' B ' series breaking capacity 10 KA ISI marked complete, all as specified and as directed.
M & L for MCB, SPN, 240 V, 40 Amps, and ‘C’ series breaking capacity 10 KA complete ISI marked , all as specified and as directed.
M&L for MCB, SPN, 240V, 63 Amps and ' C ' series/curve breaking capacity 10 KA complete all as specified and directed by Engr-in-charge. (Make: Legrand/ABB/L&T/Siemens).
M&L for MCB, TPN,63 Amps,240 V, and ‘C’ series breaking capacity 15 KA complete all as specified and directed by Engr-in-charge.
Supply and fix ceiling fan regulator electronic Step type, solid state, 100W, 240 volts, complete all as specified and as directed.
S & F call bell, ding dong AC 230 volts, single pole complete all as specified and directed by Engr-in-charge.
M&L for MCCB, 4P, 415V, overload adjustable 0.63 - 0.8-1 x in short circuit fixed 63 Amps breaking capacity 25KA complete all as specified and directed by Engr-in-charge. (Make:Hager,Schnieder or Legrands).
M&L for MCCB, 4P, 415V, overload adjustable 0.63 - 0.8 -1 x in short circuit fixed 100 Amps breaking capacity 25KA complete all as specified and directed by Engr-in-charge. (Make:Hager ,Schnieder or Legrands).
S&F in repair for wall mounted LED fittings 20 watt LED 6000 k extruded aluminium heat sink provided for energy efficient heat dissipation & integrated electronic with all accessories and with lamp ,internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-charge. (Make :Havells, Bajaj/Philips/Crompton)
M& L for LED bulk head fitting 10Watt LED 6000k Ip 66 energy saving new generation bulk head fitting with opal diffuser complete with electronic driver and lamp & internally prewired & including connecting up with twin core twisted flexible copper conductor cable of suitable size after taking down old light fitting any type complete all as specified and directed by Engr-in-charge (Make :Crompton/Havells/Bajaj etc
M&L for earthing complete with galvanised steel earth plate electrode 600x600x 6mm thick burried in ground (earth pit not less than 2.25 m deep below ground level0with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts, and washers of GI or steel, GI strip protected by 40 mm bore medium grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade GI, wire mesh charcoal or coke common salt laid in altrnative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC(1:3:6) type C-1, 50 mm thick pre-cast RCC(1:2:4) type B-1 normally mix cover slab reinforced with in 8 mm dia TMT bar 10 cm C/C both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft/loose/hard soil and disposal of soil to a distance n.exc 50 m and necessry testing on completion all as shown in electrical plate No 3 MES schedule part-I complete all as specified and as directed
M/S KUMAR AVINASH
M/S ASHA ENTERPRISE
LALAN SHARMA
M/S AMARNATH AGARWALLA
M/S New Builders Corporation
M/S SINGH ENTERPRISE
DANATION CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .