Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹18.9 L+₹40,480 (2.19%)Rejected-Finance | L2 | Rejected-Finance Being Higher Bidder | |
| 3 | L3₹19.5 L+₹1.0 L (5.50%)Rejected-Finance | L3 | Rejected-Finance Being Higher Bidder | |
| 4 | L4₹23.7 L+₹5.2 L (28.2%)Rejected-Finance | L4 | Rejected-Finance Being Higher Bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
16 May 2022, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/REPLACEMENT OF DESERT COOLER, WATER COOLER, DEEP FREEZER AND REFRIGERATOR IN THE AREA OF AGE E/M EXT (WS) UNDER GE E/M LUCKNOW
2022_MES_519060_1
GE/EM/LKO/EXT(WS)/T-06 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
240 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹50,000
Yes
4 Jun 2022
20 Apr 2022
18 May 2022
20 Apr 2022
16 May 2022
4 May 2022
Amount
Taking out carefully 325 to 500/600 mm sweep desert cooler from its existing position from stand or pillar, removing the side panels, taking out cut wood pads or loose pads and disposed to a distance not exceeding 50 metres away as directed by EIC and spray painting with synthetic enamel paint of approved color (inside and outside) after preparation of old painted surfaces and reassembling and fixing in position including renewal of new wood pads complete all as specified and directed.
Repairing of leakage of tank by brazing/soldering of any size of desert cooler, testing the leakage water complete all as specified and directed.
Renewal of PVC front grill complete all as specified and directed.
Renewal of of Piano switch (5/6 Amp) suitable for desert cooler complete all as specified and directed. ( Make :- Anchor/ABB/Havelles)
Renewal of set of panels made out of PGI sheet 24 gauge thick with wood wool pads, in required quantity duly filled complete all as specified and directed.
Renewal of sprinkle pipe, PVC heavy duty 15 mm dia with tee, elbow etc. for 24"/18" sweep desert cooler complete all as specified and directed.
Renewal of PVC distributor suitable for 15 mm dia PVC Pipe, PVC elbow & connection of PVC pipe from pump to distributor suitable for 18"/24" sweep desert cooler complete all as specified and directed.
Renewal of desert cooler body, suitable for 450 mm/500 mm sweep exhaust fan, made out of 24 gauge PGI sheet with front grill and side panel with switch regulator complete all as specified and directed. Make ;- Champion/Summerking.
Renewal of Polycarbonate Plug top 3 pin16 Amp complete all as specified and directed. Make :- Anchor/ABB/Havelles/C&S .
Renewal of Polycarbonate Plug top 3 pin 5/6 Ampcomplete all as specified and directed. Make :- Anchor/ABB/Havelles/C&S complete all as specified and directed.
M&L for renewal of kit fan, motor, single phase, 230 volt AC, 1/3 HP, complete with blade arm 18" sweep size suitable for desert cooler complete all as specified and directed. (Make:- Crompton /Champion /Summer Cool/Usha)
M&L renewal of exhaust fan motor, single phase, 230 volt AC, 1/3 HP, complete with blade arm 18"/20" sweep size suitable for desert cooler complete all as specified and directed. (Make:- Champion/Crompton greaves/Khaitan/Usha)
M&L renewal of capacitor Single Phase , 230 V, AC, of following capacities 2.5 MFD complete all as specified and directed.
All as per item No 13 above but 4.0 MFD.
Taking out defective burnt exhaust fan of following sweep and of any make and transporting to contactor's workshop, opening of exhaust fan/taking out rotor and cutting out the burnt winding and cleaning the slots and rewinding of the same with the existing size of super enameled copper winding wire including insulation varnishing, greasing, reassembling testing and fixing in position 18"/24" size (exhaust fan) complete all as specified and directed.
All as per item No 15 above but 18"/20" (Kit fan)
M&L for fabrication of mild steel stand stand made stand out of MS angle iron and flat grade Fe-290-Gde E-165 of size as directed suitable for positioning the desert cooler / stablisers including painting with two coat of (black) enameled paint over a coat of red oxide primer and installed at locations complete all as specified and directed.
M&L( in repairs) for PVC connection 15 mm dia with brass ferule both and length 450 mm complete all as specified and directed.
S&F( in repairs) PTMT float valve , 15 mm dia complete all as specified and directed (Make Prayaga)
S&F (in repairs ) copper conductor twin core PVC insulated and sheathed cable size 1.50 sqmm ISI mark for pannel wring of desert cooler complete all as specified and directed.
S&F (in repairs ) copper conductor three core PVC insulated and sheathed cable size 1.50 sqmm ISI mark for pannel wring of desert cooler complete all as specified and directed.
M&L for PVC pipe heavy duty 15 mm dia for desert cooler pump to distributor complete all as specified and directed.
Supply and fixing in replacement submersible pump for desert cooler single phase, 1/40 HP, 230 volts complete all as specified and directed.
S& F in repair Exhaust fan blades 18"/20" sweep heavy duty (as per sample) complete all as specified and directed.
S&F in repair Khus pad (As per sample) suitable for desert cooler 16" / 24" sweep complete all as specified and directed.
S&F in repair wood wool (As per sample) suitable for desert cooler 24" sweep all as specified and complete all as specified and directed.
S&F (in repairs) wood wool pad (As per sample) suitable for desert cooler 325 mm to 500mm sweep complete all as specified and directed.
S&F in repairs worn out wiremesh rectangular / square fitted with all the three side panels of desert cooler of 15"/24" any make made out of 24 SWG 10mm aperture including rivetting and renewing the cut wood pads complete all as specified and directed. (Renewal of Wood pads shall be measured and paid separately).
Dismantling of defective indoor unit of 1.5 TR capacity split type AC and supply and fixing new indoor unit(Hot &Cold) of the same capacity in working condition with blower motor, front grill and all other connected items and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required the unit in wall/ceiling mounted complete all as specified and directed. (Make:-Totaline/BlueStar/LG/Voltas/Daikin/Hitachi)
Dismantling of defective outdoor unit of 1.5 TR capacity split type AC and supply and fixing new outdoor unit(Hot&Cold) of the same capacity in working condition with blower motor,fan, and condensing unit of copper, and cabinet and all other connected electricals and items for connecting with indoor unit and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with refrigerant gas as required with stand and installing the unit in wall/ceiling mounted complete all as specified and directed. (Make:-Totaline/BlueStar/LG/Voltas/Daikin/Hitachi)
Disconnecting Water Coolers,Refrigerators,Deep freezers and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user by name to concern JE complete all as specified and directed. (Spare parts shall be measured and paid separately under appropriate items)
M&L for rewal running capacitor of capacity 15 Mfd in plastic container complete all as specified and directed.
M&L for rewal running capacitor of capacity 36 Mfd in plastic container complete all as specified and directed.
Supply and replacement of push cock (BIB) 15 mm dia suitable for water coolers of any capacity complete all as specified and directed.
Supply and replacement of running capacitor of capacity 25 Mfd in plastic container complete all as specified and directed.
Dismantling of wornout base of water cooler fan blower motor of water cooler and S&F new base made out of 450mmx450mm sheet of 16 gauge including welding, rivetting and reinstalling the motor after repairs complete all as specified and directed.
Taking out compressor from water cooler of any make by cutting of suction and discharge lines for carrying out necessary repairs to the water cooler base such as renewal of MS angle iron , base plate, nuts , washers, bolts,compressor rubber grooves and refixing it including N2 flashing and charging of refrigerent with non CFC refrigerant gas matching with R-22 in required quantities and testing of 120/150 litres capacities of water coolers complete all as specified and directed.
All as per item No 37 above but for 40 / 80 Litres capacities of water coolers
Dismantling of unserviceable compressor of any make/brand from water cooler including disconnecting suction / Discharge copper tubing and Supply&fixing new compressor (sealed unit) with nuts, bolts, rubbers grommet and washer, connecting copper tubing by welding flare nuts, detecting leak and repairs if any flushing and pressure testing by nitrogen & etc. vacuumising, charging with non CFC refrigerant gas matching with R-22, of 1 TR Capacity ( Make Emmerson Model HR-13) or equivalent of other specified make & Model complete all as specified and directed.
All as per item No 39 above but No. CAJ 34 G-DE1( KCJ-444HAG-B220 of Emerson)or equivalent of other specified make & Model
Renewal of copper tubing 3/8"dia complete for fixing in water coolers complete all as specified and directed .
Renewal of copper tubing 1/2" dia in water coolers 150 litres capacity and refrigerators 165/286/300 Ltr complete all as specified and directed
Renewal of copper tubing 1/4" dia complete in water coolers 150 litres capacity and refrigerators 165/286/300 Ltr complete all as specified and directed
Renewal of CP pipe connector including flange, screw, CP nozzle of nipple, female nozzle and extention complete all as specified and directed
Taking out defective blower motor with blade and supply & fixing new blower motor with blade AC 240 volts, 50 HZ single phase, of 1/10 hp capaciites complete all as specified and directed.
All as above item No 45 above but for 1/16 HP capacity
All as above item No 45 above but for 1/8 HP capacity
Taking down and S&F aluminium fan blade of blower motor of 1/16 HP complete all as specified and directed.
Taking down and S&F PVC fan blade of blower motor of 1/8 HP complete all as specified and directed.
Taking down and S&F PVC fan blade of blower motor of 1/10 HP complete all as specified and directed.
Renewal of condensing coil for 150 litres Capacity water cooler of any make complete all as specified and directed.
Renewal of condensing coil for 60/80 litres Capacity water cooler of any make complete all as specified and directed.
Renewal of front panel of 60 / 80 litres capacity of water cooler made out of 22 gauge MS sheet of shape and size and providing two coats of spray painting with synthetic enamel paint over a coat of pink primer on all the surfaces of panel including discconeccting required parts and reconecting complete all as specified and directed.
All as above Item No 53 above but for 150 Ltrs capacity water coolers.
M&L for disconnecting of water cooler of 150 litres capacities from its position, taking out water from its water tank, cleaning of water tank by washing with washing powder and with fresh water externally and internally and spray painting with synthetic enamel paint of approved tint/colour to all painted surface of water cooler of following capacities after preparation of old painted surfaces without disturbing the components & wiring etc. complete and reconnceting complete all as specified and directed.
All as per item No 55 above but for 40 / 80 Litres capacities of water coolers
All as per item No 55 above but for 60 / 120 Litres capacities of water coolers
Checking of leakage in refrigerant system of water cooler of 150 litres capacity by putting nitrogen under pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuumising the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed.
All as per item No 58 above but for 40 / 80 and 60/120 Litres capacities of water coolers
Supply & fixing (in repairs) starting relay for 1 TR water cooler complete all as specified and directed .
Supply & fixing (in repairs) starting relay for 1/3 TR water cooler complete all as specified and directed .
Supply & fixing (in repairs) running capacitor (conforming to IS:2993 - 1975) AC 440 volts in plastic container of 10 mfd capacities complete all as specified and directed.
Supply & fixing (in repairs) running capacitor (conforming to IS:2993 - 1975) AC 440 volts in plastic container of 6 mfd capacities complete all as specified and directed.
Supply & fixing (in repairs) overload protector for 1.00 TR compressor complete all as specified and directed .
Supply & fixing (in repairs) overload protector for 1/3TR compressor complete all as specified and directed .
S & F Thermostat long tail for water cooler complete all as specified and directed.
S & F Thermostat short tail for water cooler complete all as specified and directed.
Transporting defective blower motor of 1/ 16 HP capacities from AGE E/M yard to contractor's workshop, dismantling the burnt winding & rewinding of blower motor with the existing size super enameled copper winding wire including insulation, varnishing, greasing, testing and transporting back to AGE E/M yard for refixing at the site complete all as specified and directed.
All as per item No 68 above but for capacity of 1/8 HP
S&F ( in repairs) gas filter, flare type, 3/4"x 1/2" flare, complete all as specified and directed.
S&F in repairs copper capillary of size 0.55 mm complete all as specified and directed
Taking down and S&F PVC insulated , copper conductor cable, 3 core of size 48/20 complete all as specified and directed.
Taking down unsv compressor from the regrigerator and Supply & fixing sealed unit compress or suitable for 165/190/195 litres refrigerator ( 1/8 TR) capacities , charging with gas and making connections and testing complete all as specified and directed. Make- LG/Whirlpool/Samsung/Godrej)
All as per item 73 above but for capacity of 286/300/310 ltrs (1/6 TR) refrigrators (Make-LG/Whirlpool/Samsung/Godrej)
S&F cooling coil of 165/190/195 litres capacities refrigerator after disconnecting the cooling coil from refrigerator, Nitrogen gas pressure testing and flushing out the system and charging of Non CFC gas as per required quantity and testing complete all as specified and directed.
All as per item 75 above but for capacity of 286/300/310 ltrs (1/6 TR) refrigrators
S&F condensing coil of 165/190/195 litres capacities refrigerator by disconnecting condensing coil from refrigerator, N2 pressure testing and flushing out the system and charging of Non CFC gas as per required quantity and testing complete all as specified and directed.
All as per item 77 above but for capacity of 286/300/310 ltrs (1/6 TR) refrigrators
Checking of leakage in refrigerant system of refrigerator of 165/190/195 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed.
Checking of leakage in refrigerant system of refrigerator of 286 /300/310 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed.
S&F in repairs starting relay, open type for refrigerator of capacity 165/300/310 litres complete all as specified and directed.
S & F in repairs over load protector for 1/6 HP refrigerator of capacity 165/300/310 litres complete all as specified and directed.
S & F in repairs thermostat defrost type for refrigerator complete all as specified and directed.
S & F in repairs thermostat non defrost type for refrigerator complete all as specified and directed.
S&F New PCB for 300/310 ltr refrigerators, complete all as specified and directed. (Make-Samsung/LG or others as required)
Supply and filling R-134 Gas suitable for Water Coolers,Refrigerator, Deep freezer complete all as specified and directed.
Dismantling of existing repairable deep freezers of any make and capacity from its position after disconnecting electric connections, transporting from site to Contractor's workshop for carrying out repairs and renewal/ replacements of Parts, reassembling and transporting back to the site including installation of the same on same location and making electric connection etc. complete all as specified and directed. (Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow.
Taking down and S&F starting relay for 200 Ltr. Capacity deep freezer complete all as specified and directed.
Taking down and S&F starting relay for 300 Ltr. Capacity deep freezer complete all as specified and directed.
Taking down and S&F over load protector suitable for 200/300 Ltr deep freezer complete all as specified and directed.
Taking down and S&F running capacitor for 200/300 Ltr capacity deep freezer complete all as specified and directed.
Taking down and S&F thermostate suitable for 200/300 Ltr. Capacity deep freezer complete all as specified and directed.
Taking down and S&F starting capacitor for 200/300 Ltr. Capacity deep freezer complete all as specified and directed.
Taking down defective compressor of following capacity of deep freezer of any Make and depositing same in AGE E/M EXT(WS) yard and fixing sealed unit compressor as specified here under including brazing and with necessary nuts and bolts, copper filter, capalary and supply & charging of refgn Gas Non CFC in required Qty and testing 200 Litres capacity deep freezer compressor Model No. KCN 372 of Kirloskar complete all as specified and directed.
All as per item No above 94 but 300 Litres capacity deep freezer compressor Model No. KCN 411 of Kirloskar
Checking of leakage in refrigerant system of deep freezer of 200 / 300 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed.
Renewal of Fan Motor with blade of deep freezer, 230Volts rating, AC, Single Phase, 50 Hz including disconnection and reconnecting and testing complete all as specified and directed.
M/S Asian Engineers
Avinash Enterprises
M/s Acme Engineers and Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .