Loading…
Loading…
Tender Value
₹6.0 Cr
EMD Value
₹4.5 L
Closing Date
2 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
S AND T
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or " V" whichever is less; where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully or substantially completed any of the following during last 07(seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. Similar Nature of work for this tender is -"Panel Interlocking OR Route Relay Interlocking OR Electronic Interlocking OR IBH OR Automatic Signalling OR LC gate Interlocking."
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Rehabilitation and replacement of ELB equipment at old & Overaged 65 Nos. interlocked LC Gates over HWH.
SDSTE-REP-ELB-65GATES-26
SDSTE-REP-ELB-65GATES-26
Open
Works - General
12 Months
Howrah, West Bengal
₹0
₹4.5 L
2 Mar 2026
5 Feb 2026
73 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 5,96,81,323.64 | ||
| — | — | — | Above/ 29189420.00 Below/P | ||
| "Supply of Electrically Operated Lifting Barrier complete set suitable for 24V DC, supply with hand generator back up & motorized boom locking arrangements as per RDSO Spec. SPN/208/2012 with latest amendment. One set consisting of 2 nos. of lifting barrier pedestals, each with 8 contact circuit controller with top roller type limit switches, hand crank, 2 electric motors, 24vdc of capacity suitable to operate barriers upto 32' long booms, 2 nos. of steel octagonal booms of 32 feet length with 2 nos. Stop boards, boom light boxes, MS counter weights and 2 nos. of boom support with motorised boom locking but without fringes along with control panel with buttons and indicating lamps, motor connectors and MCB and hand generator (24VDC) to operate 2 barriers of 1 set. This includes supply and installation of gate hooter - 1 no and Dual Tone Bell /Buzzer with Flasher arrangement and 20 Watt horn working on 24 V DC/ 110 V AC- 1 no with all fixing arrangements. All of the above items including supply of nuts & bolts, foundation as required & supply of cement, civil work materials and etc. Shall be done by the contractor for commissioning. Only 230VAC supply shall be arranged by the railway in nearby relay room. The complete electric lifting barrier set shall confirm to RDSO SPEC NO. RDSO/SPN/208/2012 with latest amendment. Inspection - RDSO. along with Spares & tool kit mentioned in RDSO Spec. SPN/208/2012 clause 10.1 & 10.2 as below- Following spares shall be supplied alongwith each set (02 nos.) of Electric lifting barrier as per requirement of the purchaser i) Steel boom - 1 no. complete. ii) Belt - 1 no. iii) Crank handle - 1 no. iv) Motor Contactor - 1 no. v) Motor protection MCB- 1 no. vi) Push button complete- 2 nos. vii) Limit switch - 3 nos. (1 lever type and 2 top roller type) viii) Fuses used - 2 sets Tool kit consisting of standard sizes of wrench / spanner and Allen keys should also be supplied with each set (02 nos.) of Electric Lifting barrier. Inspection: RDSO" | — | 65.00 | — | — | |
| — | — | — | Above/ 3217890.00 Below/P | ||
| Installation, testing and commissioning of electrically operated lifting barrier, complete with Casting of cement concrete foundation (including supply of sand, stone, cement, bolt, plate etc.) for pedestal and boom rest post, cabling, power supply connection & wiring with complete outdoor work as per approved drawing, wiring etc. Inspection: Consignee | — | 65.00 | — | — | |
| — | — | — | Above/ 70421.00 Below/P | ||
| Supply of Dual Tone Bell /Buzzer with Flasher arrangement and 20 Watt horn working on 24 V DC/ 110 V AC for warning road users at LC gates. Inspection: Consignee | — | 13.00 | — | — | |
| — | — | — | Above/ 222521.00 Below/P | ||
| Supply of electrical lifting barrier booms of 9.76 meter each as per DRG RDSO/S 11600 . The material will be as per RDSO Specn. No. RDSO/SPN/208/2012/Ver. 2.0 and Amendment 1 or latest. Inspection: Consignee. | — | 13.00 | — | — | |
| — | — | — | Above/ 448734.00 Below/P | ||
| Supply of Motorised boom locking set (consisting of locking arrangement for two booms) . The material will be as per RDSO Specn. No. RDSO/SPN/208/2012/Ver. 2.0 and Amendment 1 or latest. Inspection: Consignee. Supply of Motorised boom locking set (consisting of locking arrangement for two booms) . The material will be as per RDSO Specn. No. RDSO/SPN/208/2012/Ver. 2.0 and Amendment 1 or latest. Inspection: Consignee. | — | 13.00 | — | — | |
| — | — | — | Above/ 26702.00 Below/P | ||
| Supply of Power contractor/ Relay for motor 24V DC, MAKE L&T MLO/SIEMENS. The material will be as per RDSO Specn. No. RDSO/SPN/208/2012/Ver. 2.0 and Amendment 1 or latest. Inspection: Consignee. | — | 13.00 | — | — | |
| — | — | — | Above/ 173186.00 Below/P | ||
| Supply of PMDC MOTOR 24V DC, 90W/1500RPM.The material will be as per RDSO Specn. No. RDSO /SPN/208/2012/Ver.2.0 and Amendment 1 or latest. Inspection: Consignee. | — | 13.00 | — | — | |
| — | — | — | Above/ 32136.00 Below/P | ||
| Supply of boom lock PMDC motor 24V DC/40W /1500RPM.The material will be as per RDSO Specn. No. RDSO/SPN/208/2012/Ver.2.0 and Amendment 1 or latest. Inspection: Consignee. | — | 13.00 | — | — | |
| — | — | — | Above/ 13000.00 Below/P | ||
| Supply of TIMING BELT. The material will be as per RDSO RDSO/SPN/208/2012/Ver. 2.0 and Amendment 1 or latest. Inspection: Consignee. | — | 13.00 | — | — | |
| — | — | — | Specn. | ||
| — | — | — | No. | ||
| — | — | — | Above/ 80119.00 Below/P | ||
| "Supply of FRICTION CLUTCH SUB ASSEMBLY. The material will be as per RDSO Specn. No. RDSO/SPN/208/2012/Ver. 2.0 and Amendment 1 or latest. Inspection: Consignee." | — | 13.00 | — | — | |
| — | — | — | Above/ 26040.00 Below/P | ||
| Supply of Limit Switch Set for boom lock proving. The material will be as per RDSO Specn. No.RDSO/SPN /208/2012/Ver.2.0 and Amendment 1 or latest. Inspection: Consignee. | — | 20.00 | — | — | |
| — | — | — | Above/ 1423435.00 Below/P | ||
| "Supply, installation and commissioning of ELB opening ,closing and emergency key operation system as per CSTE/ ER'S Typical circuit diagram No-S.I./TYP/ 0093 & S.I./TYP/ 0094, dtd. 24.04.2025. Which requires i) Rugged 'NO' press switch(Green) - lNo ii) Rugged 'NO' press switch (Red)- lNo iii) Robust type rotary switch similar to P.I. SM'S key-1 No. iv) Veeder counter to record the count of emergency key operation- lNo v)Superior quality 24VDC pizo buzzer-1 No vi)Good quality 10 mm LED Green- lNo vii)Good quality 10mm LED Red-1 No viii)Good quality 10mm LED yellow-4 No ix)Robust Indication Board with white hylam sheet top (approx dimension 8"x12"x2")- lNo. x)good quality 6"x6" box with transparent cover with locking and sealing arrangement to accomodate emergency rotary switch and veeder counter. Note -contactor has to provide all other items require like flexible wire 16/0.2sq mm for wiring, casing, capping etc require for installation with one spare for each item from item number -i to viii).Inspection -RDSO." | — | 65.00 | — | — | |
| — | — | — | Above/ 195260.00 Below/P | ||
| Dismantling of level crossing gates with all accessories as per site engineers. | — | 65.00 | — | — | |
| — | — | — | Above/ 27900.00 Below/P | ||
| "Termination of Outdoor Cables (Main Cables /tai1 cables) at both ends in location boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued b y Engr. incharge of the work. Inspection: Consignee " | — | 3100.00 | — | — | |
| — | — | — | Above/ 35100.00 Below/P | ||
| Carrying out relay alteration to the existing relay wiring at relay rack/location box as per the approved circuit diagram. These work includes the releasing of existing unused wires and wiring the relays using 16/0.2 mm copper wire as per RDSO Spec. Wire to be procured from RDSO's approved source and inspection: by RITES [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh]. Note: - wire to be procured from RDSO's approved source only. All required material like wire, soldering material, paint etc. To be supplied by the contractor for execution of the work. | — | 130.00 | — | — | |
| — | — | — | Above/ 127075.00 Below/P | ||
| Fixing of Q series relay base plate/metal to metal relay mini group and major group base plate, laying, bunching, lacing, dressing & packeting of 60/40 core PVC indoor cable/flexible wire and termination of 60/40 core cable/flexible wire on tag block/base plate & base plates & soldering. This includes fuse wiring, bus bar looping etc. required for keeping installation ready for circuit wiring work & panel throughing work. The work shall be done as per approved plan, extant practice on ER & the instruction of Rly. Engineer at site. Inspection authority:- Consignee | — | 325.00 | — | — | |
| — | — | — | Above/ 486200.00 Below/P | ||
| Supply of earth electrode mild steel galvanized, light class, IS:1239(PART-I) - 1979.earth electrode pipe should be with 3 mm thick, 50 mm dia and perforated(staggered),5 mm dia holes, 2 nos per 305 mm length with clamp of MS FLAT(galvanised) of size 35 mm x 6 mm (SPEC. NO.226 STD). Earth pipe should include CI threaded cap. Materials to be procured and designed as per CSTE /ER'S DRG.NO.SI/TYP/0097 DTD. 25.03.25. Inspection: - BY RITES [for value of material above Rs. 5.O lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh] | — | 325.00 | — | — | |
| — | — | — | Above/ 296075.00 Below/P | ||
| Supply of MS FLAT (SPEC. NO. 226 STD or latest) of size 35 mm x 6 mm with length 5 mtr with holes of 12 mm dia at both ends as per CSTE/ER'S DRG. NO. SI/TYP/0097 DTD. 25.03.25. (or latest). Inspection : by consignee. | — | 325.00 | — | — | |
| — | — | — | Above/ 377325.00 Below/P | ||
| Fixing of earth electrode including laying and installation of MS flat of size 35 mm x 6 mm with length 5 mtr or as per extant practice of Eastern Railway. As per CSTE/ ER'S DRG. NO. SI/TYP/0097 DTD. 25.03.25. for apparatus cases, signal post & other equipment as per instruction of site engineer. Provision for fixing MS flat at apparatus cases/ signal post/other equipment should be made by the firm at site. Full threaded bolts of 10 mm dia and length 40 mm should be welded in the apparatus cases in such way that the MS flat at apparatus case end can be fixed from outside or from inside. Welding arrangement with accessories and welding materials should be arranged by the contractor for fixing of bolts at equipment end where required as per instruction of site engineer. All hardware and other miscellaneous materials required for installation to be supplied by the contractor except earth electrodes and MS flat. Note:-all materials required to be arranged by the contractor except Earth Electrode & 2 core cable will be supplied by the railway. | — | 325.00 | — | — | |
| — | — | — | Above/ 1038440.00 Below/P | ||
| Supply and installation of LED type table mounting gate control-cum-indication panel of required size as per site engineer and as per signalling plan including supply of wooden table (hard wood) of standard height for mounting of panel, cable entry in panel with 50 mm dia gallant. Note- gate panel should have button operation for gate close & open instead of switch. The switch for signal operation preferably should have 2NC/2RC contact. Make-Deltron or similar. Inspection- Consignee. | — | 65.00 | — | — | |
| — | — | — | Above/ 779232.00 Below/P | ||
| Supply of IPS DC-DC converter 24-32V DC, 10 Amp or 60-66 V DC, 5 Amp or 60-100V DC,1 Amp/ 3 Amp/S Amp as per specification No. RDSO/SPN/165/2012, version-3.0 or latest. Make: M/s. Statcon Ltd./ M/s. HBL Ltd./M/s. Amararaja Ltd. Or Other RDSO approved make, compatible for the IPS make specified by Purchaser. | — | 32.00 | — | — | |
| — | — | — | Above/ 498688.00 Below/P | ||
| Supply of Self Regulating Type Battery Charger, 230V AC/24V DC, 20 Amps as per RDSO Specn. No.IRS:5- 86/2000 (Amnd.4) or latest. Inspection: RDSO | — | 16.00 | — | — | |
| — | — | — | Above/ 1399002.00 Below/P | ||
| "Supply of pure sine wave 500 VA online inverter input voltage: 24V DC, output voltage: 110V AC as per RDSO SPEC NO. IRS: 5-82/92 (AMD.2) OR LATEST. Note- Installation should be through OEM's representative. Inspection: RDSO." | — | 33.00 | — | — | |
| — | — | — | Above/ 1508228.00 Below/P | ||
| Supply of unchanged Low Maintenance Lead Acid (LMLA) secondary cell, shelf mounting type conforming to RDSO Specn.No. IRS:5-88/2004 or latest with inter cell connectors, nuts and bolts etc. Inspection: RDSO (A) 2V, 80 AH | — | 422.00 | — | — | |
| — | — | — | Above/ 154874.00 Below/P | ||
| Charging of lead acid cell (Secondary cell) of various capacities as per Manufacturer's/Railway engineer's instruction. Acid and distilled water to be supplied by the contractor. Specific gravity acid should be approved type duly inspected by consignee. This includes installation and commissioning of battery in circuit. Battery to be kept on wooden rack. Inspection: Consignee. (A) 2V, 80AH | — | 422.00 | — | — | |
| — | — | — | Above/ 258648.00 Below/P | ||
| Supply of Single Phase Transformer, 230V AC/(110- 130)V AC, 2 KVA as per RDSO Specn. No.IRS:5-72/88 (Amnd. 2) or latest. Inspection: RDSO | — | 26.00 | — | — | |
| — | — | — | Above/ 904540.00 Below/P | ||
| Supply of full size apparatus case (GKP type) (as per DRAWING NO. SW SK NO. 4/90 & & other applicable GKP SW Drawing). This includes supply of location box (GKP type) with 'E' type lock & key, fitted on location door on both side, E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S- 11500. Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee subject to procurement from RECOMMENDED LIST OF FIRMS FOR MECHANICAL SIGNALLING ITEMS if value of whole item in work less than 5 lakhs or as per extant policy | — | 65.00 | — | — | |
| — | — | — | Above/ 229580.00 Below/P | ||
| "Casting, concreting and curing of concrete foundation ((in ratio 1:3:6), erection and installation of full size apparatus case (GKP type)/Stainless Steel (SS) Apparatus Case as per DRG.NO. S&T/C-6/98(NKG) with 'E' type lock on CC foundation. This includes cost of all materials required for fixing holding down bolts, casting, concreting. Note: - bolts, nuts and washers, bitumen compound to be supplied by contractor and bitumen compound to be used in between apparatus case and foundation as per site engineer. This also includes bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. Note: - Location boxes to painted with anti- corrosive paints as per IS:- 9862-1981, one and half feet from the bottom, on all surfaces- both inside and outside. Inspection: Consignee " | — | 65.00 | — | — | |
| — | — | — | Above/ 313950.00 Below/P | ||
| "Fixing by slotted angle, wiring of terminal strips, hylam strip, relays, fuses with base, fixing of hard wood shelves for full size apparatus case with termination & Earthing of cables and wiring with lettering as required including supply of slotted angles, wires, ferrules for marking and miscellaneous materials per location to be supplied by contractor. (all materials except relay, terminal strips, Bakelite strip, fuses with base and hard wood shelves to be supplied by the contractor). Wires to be used for this purpose should be procured from RDSO'S approved firm and to be inspected by RDSO. [Quantity of wires to be specified by contractor]. NB- power cable to be terminated with proper lugs and required buss bar and other terminals to be supplied by the contractor. Inspection: Consignee " | — | 65.00 | — | — | |
| — | — | — | Above/ 6875558.64 Below/P | ||
| Supply of Underground, Armoured, Unscreened Railway signaling cable (Heavy Duty) with high conductivity copper conductor of size 12 Core X 1.5 sq mm as per Specn. No.IRS: S- 63/2014 (Rev.4.0) with latest Amdt.if any. Inspection : RDSO | — | 24.00 | — | — | |
| — | — | — | Above/ 7891000.00 Below/P | ||
| Excavation of cable trench as per cable route plan, 1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/ 003 or latest alongside the track in hard soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc., covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. Note:-(a)for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. of cables headway is not available, 4" of 1:2:4 concreting should be done. Note:-(b-1) payment wifi be made as per actual work done on pro-rata basis, if required depth is not available at site. (b-2) if the depth of trench is not uniform in a span of 100 mtr. Or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment. | — | 13000.00 | — | — | |
| — | — | — | Above/ 120000.00 Below/P | ||
| Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each Gantry Post/hectometre post.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. | — | 24000.00 | — | — | |
| — | — | — | Above/ 140244.00 Below/P | ||
| Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor). Wherever depth of 0.5 m cable trench is not feasible, cable shall be protected as :- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench. | — | 39.00 | — | — | |
| — | — | — | Above/ 768000.00 Below/P | ||
| Supplying and placing of one layer of standard size of 'B' grade quality bricke of the local make spreading on cables laid.(minimum size of brick 200mm X l00mm X 70mm). (A) Width wise ( more than 2 cables) | — | 24000.00 | — | — | |
| — | — | — | Above/ 332800.00 Below/P | ||
| Repair of pucca roads to original state in level crossing area after cable laying. | — | 1300.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
CheckListAnnexItoVIIIUPDATED.pdf
Annexure-IX.pdf
Annexure-X.pdf
Annexure-XI.pdf
AnnexureV.pdf
Annexure_VA.pdf
Annexure-VIA.pdf
Annexure-VIB.pdf
GCCwithCorrectionSlips1to10.pdf
JPO-CABLEDIGGINGWORK-VICINITYOFUNDERGROUNDCABLE-SRDSTESRDEN-C-240124.pdf
LabourCess.pdf
TermsofPayment.July-25.pdf
Updatedtenderdocument-ELB.pdf
NewEarthElectrodeDrawing1.pdf
Foundation.pdf
ALTEREDTYP9394_2.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .