Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAccepted-AOC OFFICE 4 9 SWARG ASHRAM NANAK RAM COLONY PARMANAND CHOWK DELHI 110009 | DELHI | DELHI | DELHI | 110009 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹40.9 L+₹1.4 L (3.52%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹40.9 L+₹1.4 L (3.54%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹41.0 L+₹1.5 L (3.74%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹45.2 L+₹5.7 L (14.3%)Rejected-Finance SHOP NO 2 JANKI PLAZA BHAGWAN MAHAVIR PATH KOPARGAON AHMEDNAGAR MAHARASHTRA 423 601 | KOPARGAON | AHMEDNAGAR | MAHARASHTRA | 423601 | L5 | Rejected-Finance Being L5 |
Tender Value
₹48.8 L
EMD Value
₹97,600
Closing Date
5 Oct 2024, 6:00 pmClosed
GARRISON ENGINEER (MIS) MHOW
Garrison Engineer (Maint) Infantry School , Mhow -453441
SPECIAL REPAIR TO BUILDING NO CB 350 SINGLE OFFRS ACCN CB 351 SERVANT QTRS IN DEMO BN AND PROVN OF RECORD ROOM NEAR BUILDING NO SM 131 GE OFFICE UNDER GE MIS MHOW
2024_MES_673140_1
8699/GE (MIS)/Mhow
Open Tender
Civil Works - Others
Item Rate
150 days
GARRISON ENGINEER (MIS)
All as per Tender document
7 documents required · 7 mandatory
₹500
GE (MIS) Mhow
₹97,600
Yes
30 Oct 2024
7 Sept 2024
7 Oct 2024
7 Sept 2024
5 Oct 2024
21 Sept 2024
Amount
M&L for taking down/dismantling of existing roof treatment of any description such as old APP membrane roof treatment etc terracing including screed bed/plastering of any thickness and removing the debris outside MD land etc. and carrying out the following roof treatment complete all as specified and as per Manufacturer's instructions:- (a) Cleaning the existing roof surface and brushing with neat cement slurry @3 Kg per Sqm area complete. (b) Rendering average15mm thick in cement mortar 1:4 mixed with integral water proofing compound and finish the surface even and smooth without using extra cement complete. (c) Preparation of surfaces and applying bituminous primer (conforming to IS-3384-1965) @ 0.40 Kg/Sqm complete. (d) Cutting out cracks to V- section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed. (e) Applying two coats of tack coat of Industrial bitumen grade of 85/25 at the rate of 1.20 Kg per sqm including cleaning surfaces (1st coat as a bonding material below membrane and 2nd coat on top of membrane (f) APP based polymeric membrane minimum weighing 3kg/sqm and reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and as per Manufacturer's instructions complete. (9)Applying two coats of bitumen based aluminium paint @ 0.15 Kg/Sqm for each coat over APP membrane including preparation of surface complete all as specified and directed.
M&L for cement concrete 25mm thick type B-1, 1:2:4 (12.5mm graded stone aggregate) as in roof top without using extra cement etc complete all as specified and directed by Engr-in-Charge.
Roughening surfaces old concrete floor by picking,sweeping clean and washing down with water to remove dust ect complete all as specified and directed
M&L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matched over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed by Engr-in-Charge.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in above for work on vertical surfaces such as skirting dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matched over and including 10mm thick back coat plastering in cement mortar 1:4 complete all as specified and as directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished and exposed visible edge moulding/rounding ) in steps, jambs, pillars, window cills, cooking platforms and like over and including 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M&L for 20mm thick Granite (of any type)tiles mechine cut,in skitrting/dado laid over cement screed and jointed with gray cement slurry,and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over and including 10mm thick back coat plastering of cement mortar 1:3 complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles from site
M&L for taking down/dismantling of existing sunken floor of any description, removing the debris outside MD land etc and M&L for water proofing treatment to sunken floor surfaces of RCC slab by the following specifications as specified and directed:- (a) Demolition of old sunken surfaces complete and cleaning of all loose particles and applying cement slurry @3.00 kg / sqm on old surfaces by brushing. (b) M&L for PCC 1: 1.5:3 type A with using 12.5mm graded stone aggregate in slope of average thickness 50mm on sunken floor slab mixed with and including integral water proofing compound manufactured by Dr FIXIT or equivalent as approved, finish the surface even & smooth without using extra cement. (c) M&L for rendering 15mm thick in cement mortar 1:3 mixed with & including integral water proofing compound on sunken floor and sides of (Vertical surface) sunken portion. (d) M&L for bituminous primer (conforming to IS-3384-1965) @0.40 Kg/Sqm complete. On complete sunken surfaces of floor & wall and provide necessary connections to soil/waste pipe from WC/ nahani trap etc including demolition of old sunken complete all as specified and as directed. (e) After laying of all sewage/plumbing pipes with fixtures in position, apply two coats of polymeric based chemical as per manufactures instructions over bottom and sudes of sunken portion upto 600 mm height. (f) M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with plyester non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed. (g) M&L for filling the sunken floor with PCC 1:5:10 type E-2 using brick aggregate. (h) S&F 50 mm dia CPVC pipe projecting 450 mm clear of face outer wall shall be provided to drain out seepage water if any. (j) Testing of sunken as per specification mentioned in SSR part-I/ P.S. (NOTE : Floor Area shall be measured for payment).
M&L for Non skid ceramic tiles coloured, 7 to 8 mm thick (Square / rectangular ) area of each tile exceeding 0.06 Sqm but n. exc 0.11 Sqm, over & including 15mm thick screed bed in cement mortar (1:4) in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles as directed and specified.
M&L for glazed ceramic coloured tiles of size not less than 350x 250/ 450X 350 / 450x300 and 7 to 8mm thick as on vertical surfaces such as wall, dado, skirting etc set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10 mm thick backing coat on fair faces of brick work in cement mortar (1:4) complete all as specified and as directed.
Taking down cement plaster from brick or concrete surface incl racking out joints hacking for key and scrubbing down with water complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:4 mixed with integral water proofing compound while concrete surface is green and finish the surface even and smooth without using extra cement complete all as specified and as directed. Note:WPC shall be measured and paid separately.
M&L for rendering 10mm thick in cement mortar 1:6 on brick surface of walls finishing even & smooth without using extra cement complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and as directed.
Complete removal of existing treatment on wall/roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc by skilled labour complete all as specified and directed.
M&L for providing and applying minimum 1mm thick wall care putty over prepared surface to achive the surface even and smooth for painting. Note: Putty to be carried out through air less spray machin (Mechanical means)
M&L for two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali and fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) 1.43 litre/10sqm over and including priming coat of exterior primer applied @ 0.90 litre /10sqm over new surface including preparation of new surfaces complete all as specified and as directed.
M&L for preparation of surfaces and applying two coat of oil bound distemper with roller on old treated surface of wall etc complete all as specified and directed.
M&L for preparation of old treated surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
M&L for preparation of old steel surfaces of any description exceeding 10cm width or girth and applying one coat of synthectic enamelled paint complete all as specified and directed.
M&L for preparation of old treated wood or wood based surface of any description exceeding 10cm width or girth and applying one coat of synthectic enamel paint complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store, complete all as specified and as directed.
S&F 16mm outer dia 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
Taking up or down 25mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
S&F 25mm outer dia 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
S&F in repair PVC(SWR) Gully trap 125/110mm,setting and jointing with solvent cement complete all as specified and directed.
Dismantling of cast iron pipes jointed in cement mortar 100 / 75 mm bore complete all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trench complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) bend with access door complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) bend complete all as specified and directed.
S&F in repair 110 mm dia bore PVC (SWR) branch piece single (single Y) equal or unequal with rubber ring joints, fixed complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trench complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR) bend with access door complete all as specified and directed.
Dismantling water tanks and removing to store Capacity of tank exc 500 and nexc 1000 litres complete all as specified and directed.
S&F rotational moulded polythylene water storage tanks(double layer), 1000 Ltrs capacity, (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including providing and fixing PTMT ball valve high pressure with polythene float and fly nut, 20mm bore complete all as specified and directed.
Dismantling water tanks and removing to store Capacity of tank exc. 250 and n exc. 500 litres complete all as specified and directed.
S&F rotational moulded polythylene 500 Ltr capacity water storage tank (double layer)(cylindrical/vertical with closte top) hoisted and fixed in position all as specified in SSR Part-I including providing and fixing PTMT ball valve high pressure with polythene float and fly nut, 20mm bore complete all as specified and directed.
S&F in repair wash hand basins, vitreous china,of size 550x400mm (flat back, or angle back type) including cutting for and pinning in ends of brackets or erecting stand exclusive of fixing of supply and waste pipe etc complete all as specified and directed.
S&F in repair padestal pattern Vitreous china wash down water closet pan white colour, with 110mm PVC(SWR) 'P' Trap including joint run and lead front or back inlet,connection to drain (or out going pipe),flusing pipe etc including S&F flushing pipe antisyphone pipe, plastic water closet seat cover white closed pattern with flat bottom complete as specified and directed.
S&F in repair CP brass fancy type 15mm bore bib taps, screwed down , and screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair 15mm bore pillar taps, cast copper alloy with capstan heads, chromium plated,fancy type screwed down high pressure with or without lettered “HOT” or “COLD” with long screwed shanks and fly nuts complete all as specified and directed.
S&F in repair 15mm bore, 450mm long, PVC connections with brass unions internally threaded both ends complete fixed to iron pipe at both ends complete all as specified and directed.
S&F in repair of CP fancy type Stop Valve ( Concealed type),cast copper alloy, screwed both ends for iron pipe or for union of 15mm bore complete all as specified and directed.
S&F in repair of CP Brass Fancy type shower rose 15mm dia with 125mm long CP Nipple of approved quality complete all as specified and directed.
S&F in repair towel rail 600mm long 20mm dia brass chromium plated fixed with wooden guilties embedded in cement mortar (1:3) with MS screws etc complete all as specified and directed.
S&F in repair PVC valveless, syphonic action type flushing cistern,low/high level white with inlet ball valve float and handle including brackets complete fixrd capacity of flush 10 ltrs complete all as specified and directed.
S&F in repair of sheet glass shelf assembly, approved make, consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F PVC (SWR) multi floor trap 75mm dia meter of out let ,plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair PVC body bathroom cabinet with mirror fancy type made out of 5.5mm thick mirror of size 550 x 450mm complete, Model No 555 of PRAYAG or equivalent make as approved complete all as specified and directed.
Taking down door shutter with frame n exc. 1.5 Sqm each without taking of shutter from the frame complete all as specified and directed.
S&F PVC door frames of sizes 50 x 47 mm made out of 5 mm prelam PVC sheet reinforced with MS Square tube in opening of suitable size complete all as specified and directed.
S&F butt hinges 100mm extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type B-21 complete all as specified and directed.
S&F for 150 mm long Aluminium anodizes barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm size aluminium anodized handle complete all as specified and directed.
S&F Factory made (Prelam on both sides) solid panel PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall covered with heat moulded prelam PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for styles and prelam PVC sheets for top rail, lock rail and bottom rail in either side and as gap insert for top rail and bottom rail pannelling of prelam PVC sheet to be filled in the MS welded/sealed to the styles and rails with suitable PVC sheet beading and jointed together wiht solvent and fixing in the frame at site as per specification and drawing complete all as specified and directed.
M&L for providing and fixing pre painted steel sliding window/ventilator 3-Track, 2 glass panel and 1 mesh panel sliding window fabricated from Roll formed sections made of galvanized Steel colour coated/powder coated (Base Steel as per IS 513 ‘D’ quality, galvanized as per IS 277 with zinc of 120 GM/Sq.mtr) with total coated thickness of 0.58mm. Primer coat with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with Alkyd backer of 5-7 microns or powder coated with pure polyester powder up to 50-60 microns thick. Section for external frame should be of 107x44mm, Section for shutter should be of 35x49mm. Section of mesh should be of 35 x 49 mm.The windows should be paneled with 5mm thick plain clear glass. Corner bracket for internal and external frame made of glass filled nylon. Gaskets are to be made of Ethyl Propylene Diamine Monomer (EPDM).The sections are to be cut to length, joined and assembled by means of corner bracket. The above frames should be fixed to the concrete/masonry walls by means of self expanding screws complete all as specified and directed. .
S&F mild steel framed work such as grills , gratings, etc., with ends of bars shouldered and/ or riveted, or forged in to spikes; framed guard bars ; barred iron doors; ladders; framed balusters ; walk ways ; railings; frame work of water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Taking down shutters of any descrption N.exc 1 Sqm and 2 Sqm each complete all as specified and directed.
Taking down shutters and refixing in same opening any descrption of but Exc 1.00 Sqm and N.exc 2.00 Sqm each complete all as specified and directed.
S&F 35mm thick 2nd class HW glazed skeleton shutters open rebated and prepared to receive glass, gauze etc dcomplete all as specified and directed.ivided into squares. with sash bars (any numbers )edge of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass or gauge wire.
S&F second class HardWood shutters 35mm thick, plain framed panelled shutter factory made (two panel) with lock rail & panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS:1003 complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire stapples complete all as specified and directed.
S&F in repair galvanised MS wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanized wire staples including takingout old wire mesh from steel window and fixing old steel flats and nut complete all as specified and directed.
S&F 100mm long butt hinges medium weight cold rolled mild steel complete all as specified
S&F for 200 mm long Aluminium anodizes barrel tower bolts of extruded section complete all as specified and directed.
S&F mild steel ordinary rat tail rod pattern spring 300mm size including roller & roller plate complete all as specified and as directed
S&F aluminium floor door stoppers double legged length 140mm with hard drawn steel spring fitted in floor complete all as specified and directed.
S&F 300mm size Aluminium alloy aniodised sliding door bolt with hesp staple( bolt type) and fixing clips of sheetcast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium ally and fixed complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide & not exceeding 1.5 m in depth for foundation ,manhole,laying of cable or pipe ( where provide for protection of cable or fixing poles and stay and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and directed.
S&F mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St. 240 as in frame work for sun shade, roof projection and vertical section etc. complete all as specified and directed.
M&L for preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for PCC 1:3:6, type C1 (using 20mm graded stone aggregate) as in sub base of floor complete all as specified and directed
S&F pre-painted galvalum aluminium zinc coating steel based corrugated steel sheet 0.50mm thick (total coated thickness) in roof having of any colour having tensile strength of 550 Mpa minimum, yeild strength, it shall be coated with hot dip alloy of 55% aluminimum, 43.5% zinc,1.5% Silicon and finished with resin coat on both surface @ 150 gm/ sqm of coating as specified and shall be fixed with hot dip galvanised, self drilling and self tapping screws neoprened and EDPM washers as in roof covering all as directed at site all as specified and dircted.
S&F pre-painted galvalum aluminium zinc coating steel based Plain steel sheet 0.50mm thick (total coated thickness) of any colour having tensile strength of 550 Mpa minimum, yeild strength, it shall be coated with hot dip alloy of 55% aluminimum, 43.5% zinc,1.5% Silicon and finished with resin coat on both surface @ 150 gm/ sqm of coating as specified and shall be fixed with hot dip galvanised, self drilling and self tapping screws neoprened and EDPM washers as in roof covering all as directed at site complete all as specified and directed.
Demolition of stone slabs, paving stones and tiles of any description and thickness in floors, aprons, laid, bedded and pointed in any mortar complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M&L for 80mm thick coloured precast concrete interlocking paver block (glossy finished) any shape and size confirming to IS 15658-2006 , M-35 Grade, laid over compacted dry sand and jointed with coloured cement slurry and pigment complete all as specified and directed. Note: Stone dust cushioning shall be measured and paid separately.
M&L for 50mm thick stone dust filling under floors including watering and consolidation all as specified and directed.
S&F 150mm Reinforced concrete pipes class NP-2 laid and jointed complete with collars complete all as specified and directed.
M&L of concrete bed of PCC 1:4:8 type D2 using 40 mm graded stone aggregate for 150mm dia drain pipes bedding & hunching against the sides complete after pipes are laid, jointed and tested complete all as specified and directed.
Returning, filling in trenches in soft/loose soil in layers n.exc. 25 cm after laying of cables including spreading, levelling, and well ramming complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by the Engineer -in-charge.
Cutting/filling into existing manholes for connecting new sewage line 150 mm bore (internal dia of pipe ) incl making good to disturbed benching and haunching, plaster etc and forming new branch channel ( ½ round of ¾ section) if required in cement concrete 1:2:4 type B1 and smooth finished , reforming benching as required and as directed for internal dia for the following pipe. (Each Manhole shall be measured under this item )
Demolition of brick work built in cement mortar in any position including all quoins, arches & pillars etc. complete all as directed and specified.
M&L for brick work with fly ash brick with using modular size brick, straight or cured on plan exc 6m mean radiuos built cement mortar 1:6 complete as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in coping for manhole including slightly rounded or chamfered angles roof padding/staging of water tank etc and including necessary form work finishing exposed surface complete all as specified and directed.
M&L for precast RCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in cover slab for manhole etc with plane faces and set in position complete all as specified and directed by Engineer-in-Charge.
M&L for TMT bars 6mm to 8 mm dia cut to length bent to shape required including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C-2 (using 20mm graded stone aggregate) as in plinth protection Finishing surfaces of concrete topping even and fair (without using extra cement) including making joint at every 3 m interval and at corner and filled with mixture of bitumen and sand and finished even and fair and laid in alternate bays complete all as specified and directed.
Surface dressing n exc. 15 cm deep in soft/loose soil complete all as specified and directed.
Excavation in trenches n exc. 1.50 m wide and n exc. 1.50m in depth for foundations soft well as its manhols, pier hales etc n exc. 10 Sqm on plan and n exc. 1.50m in depth and getting out soft/disintegrated rocks complete all as specified and directed.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering as required complete all as specified and directed.
M&L for Hardcore of gauge n exc. 63 mm,with broken stone and boulder, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surfaces complete all as specified and directed.
M&L for 100mm thick PCC 1:4:8 type D-2 (40mm graded aggregate) as in sub base of PCC floor complete all as specified and directed.
M&L for 40mm thick cement concrete type B-1, 1:2:4 (20mm graged aggregate) finished cement concrete surface even & smooth without using extra cement complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm excavated soft/disintegrated rock complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point of excavated soft/disintegrated rock complete all as specified and directed.
M&L for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete and sub base of floor complete all as specified and directed.
M&L for RCC Design mix (M-25) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and the like complete all as specified and directed.
M&L for RCC Design mix Design mix (M-25) as in Columns, footing, pillars, piers, posts and struts complete all as specified and directed.
M&L for RCC Design mix Design mix (M-25) as in roof beam, plinth beam,roof beam, lintel beams and Columns complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, footing, roof beam, plinth beam, slab,chajjas and similar work hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No 106.00 above but 5 mm dia and over up to and including 10 mm dia as in stirrups complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc. complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions etc complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc. 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10cm but n exc. 20cm wide complete all as specified and directed.
M&L for brick work with fly ash brick with using modular size brick, straight or cured on plan exc. 6m mean radius built cement mortar 1:4 complete as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:6 on brick work or concrete surfaces of walls, finished surfaces even & smooth without using extra cement after preperation of surfaces complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on brick work or concrete surfaces of walls, finished surfaces even & smooth without using extra cement after preperation of surfaces complete all as specified and directed.
M&L for 5 mm thick rendering in cement 1:3 on brick work or concrete surfaces, finished surfaces even and smooth without using extra cement after preperation of surfaces complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of first quality exterior weatherproof water base emulsion paint over a coat of primer of same make on wall as specified and directed, pillasters, cornices etc (upto G+3 storied building), scrapping down brooming down or steel wire brushing, and washing with water after completion of precoat treatment applying two coats of Anti fungal Weather coat paint (Exterior emulsion) white or tinted over a coat of primer (X2) complete all as specified and directed. Note :- (a) Each stage i.e preparation of surfaces, application of primer, application of first coat. application of second coat will be got passed from Engr-in-Charge/GE. (b) Written Warranty for four years or as per manufacturer's instructions, whichever is more is required to be furnished by contractor for this item.
M&L for preparation of surfaces of wall and applying two coats of oil bound distemper on wall surfaces over a coat of alkali resistance primer complete all as specified and directed.
M&L for preparation of new plastered surface of ceiling surfaces and applying three coats of white wash complete all as specified and directed.
M&L for machine cut Kota stone slab flooring 20 mm thick (+ 2mm) thick of with 58cm x 58cm in size (or nearest size as available in the market) laid over and including 25 mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) over and including 15mm thick screed bed in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab, incl rubbing and polishing to mirror finish, complete all as specified and directed.
S&F powder coated aluminium ventilator cross section conforming to IS 63.5x38.10x1.5mm consisting of two partions upper portion shall have louvers with 3mm thick pin headed glass and aluminium wire cloth 0.30mm nominal dia of wire and average width of aperture 1.56m fixed with aluminium beads and securing on outer face of frame and lower portion of ventilation shall be fixed with 3mm thick pin headed glass with IDPE rubber gasket including aluminium beads, including preparation of jombs all around in cement mortar 1:3 finishing even and smooth complete all as specified and directed.
S&F pressed steel frames 105 mmx60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed.
M&L for painting with two coats of synthetic enamel paint to wooden surfaces of any description over 10cm width or girth on untreated steel surfaces over a coat of pink primer after preparation of surfaces complete all as specified and directed.
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fittings complete etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc. complete all as specified and as directed.
Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M complete all as specified and as directed.
Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including taking down old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface all as specified and directed at site.
Taking down existing single phase electric energy meter of any capacity after disconnecting all necessary electrical connections and deposit to MES store yard of AGE E/M and refixed in position as directed by Engr-in-Charge complete all as specified and as directed.
M&L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC FRLS concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches and blank plates, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :-
(a) One light point controlled by one, one way switch 5 Amps
(b) One fan /Exhaust Fan Point controlled by one, one way switch 5 Amps
(c) One bell point controlled by one, bell switch 5 Amps
(d) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
(e) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board.
(f) One light point controlled by two way switch 5/6 Amps
All as per item No.128.00 above but using 2.5 sq. mm single core copper conductor cable of multistranded FRLSH PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 2.5 sq. mm copper conductor FRLSH PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
All as per item No.128.00 above but using 4.0 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for geyser point/AC point connecting to metal plug and socket DB incl necessary running of 4.0 sq mm copper conductor FRLSH PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. (for AC point)
S&F Modular Switch , single pole, one way, and 5/6 Amp single module complete all as specified.
S&F Modular Switch , single pole, two way, and 5/6 Amp single module complete all as specified.
S&F Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module complete all as specified.
S&F Modular Switch , single pole, one way, and 15/16 Amp single module complete all as specified.
S&F Modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module complete all as specified.
S&F Bell push modular 6 Amps single module complete all as specified.
S&F Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed
S&F modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
S&F Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified
S&F in repair integrated LED tube light fitting 1x18/20 Watt, 6000K complete fitting with all accessories duly connection with three core flexible copper cable duly fixed on two nos of PVC square boxes complete all as specified and directed. Make:- Havells Cat No. LHEXBLP7PN1W018 , Bajaj cat Pt No. BCLSB 18WH or equivalent in Wipro as epproved by GE.
S&F integrated LED tube light fitting 1x18/20 Watt, 6000K complete fitting with all accessories duly connection with three core flexible copper cable duly fixed on two nos of PVC square boxes complete all as specified and directed. Make:- Havells Cat No. LHEXBLP7PN1W018 , Bajaj cat Pt No. BCLSB 18WH or equivalent in Wipro as epproved by GE.
S&F in reapis LED light fitting 2 feet 10 watts, 6500K batten aluminium extruded with end caps complete all as specified and as directed. Make: Cat No LHEXACP7IN1W010 of Havells/equivalent make in / Wipro/Philips as approved by GE.
S&F in repair Decorative wall mounted luminaire brushed nickel finish fixture with opal glass diffuser made out of polycarbonate with unbreakable globe suitable for LED bulb and provosion of LED bulb 9W watts with base B22 complete all as specified and as directed. Make: Cat No LHFOAJE1TZ11060 of Havells or equivalent make in Philips/Crompton/Wipro as approved by GE.
S&F in repair Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe 40 mm dia medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Make:- Cat No ENXT P 36L WH CR PC SD of Bajaj or equivalent make in Philips/Wipro/Havells as approved by GE.
S&F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe 40 mm dia medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Make:- Cat No ENXT P 36L WH CR PC SD of Bajaj or equivalent make in Philips/Wipro/Havells as approved by GE.
M&L for sub main wiring with 02 runs of 6 sqmm main wire along with 01 run of 06 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC concealed / surface conduit (medium grade) wherever necessary with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same & taking down complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length. Make of cable - Havells / Finolex / RR Kabel Ltd. / L&T Make of PVC Conduit( FRLS) - Presto Plast / Finolex / Jindal / Asian / AKG
S&F flush mounting factory made Vertical TPN DB, IP-43 Protection -IK 08, with metal double door with 200 Amps rated copper busbar with 2 neutral bar, earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing with provision of sapce for TP/FP 100-125 amps G Frame MCCB as incomer and SP/TP MCBs as out going 8 way complete all as specified and directed by Engr-in-Charge.
S&F double door SPN DBs 08 way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral complete all as specified and directed by Engr-in-Charge.
S&F in repair MCCB 4 pole, 415 volts, in the existing panel / location and connection with using aluminum lugs complete all as specified and directed for 125 Amps Adjustable type with breaking capacity 16 KA complete all as specified and directed by Engr-in-Charge.
S&F MCB SPN 6 to 32 amps 10 KA, 'B' series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-in-Charge.
S&F MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'B' series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-in-Charge.
S&F metal clad box suitable for 230 volt 50 Hz for AC connection three pin and socket with MCB SP 20/32 Amps including removal of old unserviceable one complete all as specified and as directed complete all as specified and as directed
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250 mm including cutting of wall and duly connection with copper wire from ceiling rose etc complete all as specified and directed.
Labour only for refixing the celing fan/ Wall fan/ Exhaust fan obtained from item No 2 above with replacement of unsv 3 core PVC insulated PVC sheated 3 core multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal including over hauling the fan, painting of ceiling fans complete with two coats synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc. complete all as specified and as directed.
S&F in replacement of water heater storage type of 5 Star rating, capacity 25 liters with , glass coated heating element to protect the heating element from oxidation and carbonization. The geyser should be tough enough to withstand pressure upto 8 bars . The inner tank should have a minimum 7 years warranty . The geyser should have company fitted and warrented ELCB or shock safe plug including PTMT connections 15 mm size with nuts and length of 450 mm with all accessories such as safety valve, thermostate incl fixing arrangements. complete all as specified and as directed.
Taking down existing old existing unserviceable LT UG/ service cable of any description and size complete all as specified and directed.
M&L for clean and dry sand (un-washed) in trenches incl spreading and levelling for cushioning of UG cable complete all specified and directed. Note: Punned thickness shall be measured.
M&L for bricks slightly over burnt (kiln burnt) , modular bricks , best quality, locally available , laid flat, dry, laid in trenches along the length of cable transvarsally with width equal to length of brick for cable protection all as specified and as directed.
Supply, laying and jointing GI pipe 'light grade' 50 mm bore in trenches/under floors or roads/ along poles/ on wall incl clamps for protection of cables including fittings complete all as specified and directed.
Supply and laying & testing and commisioning LT underground cable 1100 volts grade, XLPE insulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches/ducts, on poles etc of size 3.5 core x 35 Sqmm complete all as specified and directed
M&L for Earthing complete (in replacement) with galvanized steel earth plate electrode 60cm x 60cmx 6.3 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.3 of MES SSR parts-I and including excavation & earth work in any type of soil , disposal of soil , providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix 1:3:6 type c-1 with 40 mm thick RCC 1:2:4 type B-J cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion, complete all as specified and directed including testing on completion.. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.
M&L for Point wiring using approved colour coding as as per IS in repairs with FR LS PVC insulated PVC unsheathed electric cable 1100V grade ISI 694 marked down through single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area drawn in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good and matching disturbed surface of wall with existing surface of wall (cutting except on ceiling for fan point only, on ceiling instead of PVC conduit surface casing caping will be used) & 1.5 sqmm green FR LS PVC insulated unsheathed copper conductor as earth wire connected to earth dolly by providing lugs including galvanised boxes and bakelite sheet for mounting switches, sockets, fan regulators etc for the following . Make of PVC conduit/Casing Caping:- Plaza/Finolex/Polycab/Kalinga/Jindal/Asian & Make of wire - Havells,Finolex,HPL
(a) One light point/fan point controlled by one switch
(b) One 5amps socket out let point controlled by one switch on same board with other switches.
(c) One 5amps socket out let point on independent board controlled by one switch.
S&F switch piano flush button single pole one way 6Amp 240 volt complete all as specified and directed.
S&F socket outlet flush type 5 pin, 6 amps, 230 volts complete all as specified and directed.
S&F LED luminaire 600 mm x 600 mm square LED panel 35/36 watts, 220 volts, lumen efficacy of 120 lumens/watt, AC Surface/recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling, including connecting up with driver three core flexible copper conductor cases of suitable size complete all as directed by Engineer- in-charge.
S&F LED Bulk Head luminaire 10W, 6000K pressure die cast housing with IP65 protection complete with electric connection all as specified and directed by Engr-in-Charge. Make:- Havells Cat No. HEXAFT10LED857SSYMBOPC, Crompton Cat No. LBH-10-CDL, Bajaj Cat No. BIBWP 10W LED as approved by GE.
S&F MCB TPN 40 to 100 amps 10 KA, c-series including connection with suitable size aluminium/copper lugs complete all as specified and directed by Engr-in-Charge.
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cmx 6.3 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.3 of MES SSR parts-I and including excavation & earth work in any type of soil , disposal of soil , providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix 1:3:6 type c-1 with 40 mm thick RCC 1:2:4 type B-J cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion, complete all as specified and directed including testing on completion.. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.50m from earth plate is deemed to be included in rate quoted.
Supply, laying & testing and commisioning LT underground cable 1100 volts grade, XLPE insulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches/ducts, on poles etc of size 4 core x 16 Sqmm complete all as specified and directed.
Supply laying and jointing GI pipe 'light grade' 40 mm bore in trenches/under floors or roads/ along poles/ on wall incl clamps for protection of cables incl fittings complete all as specified and directed.
PARIDHI CONSTRUCTION (BID ID -3128972)
M/S Sunshine Construction (BID ID -3129299)
J B CONSTRUCTION AND DEVLOPERS (BID ID -3129473)
sunway associates (BID ID -3119591)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .